Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹11.9 L+₹9,130 (0.77%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹12.4 L+₹53,120 (4.49%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹14.5 L+₹2.6 L (22.3%)Rejected-Finance 73 5 NANAK NAGAR JAMMU 180004 J K | JAMMU | JAMMU | J K | 180004 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹18.3 L+₹6.4 L (54.5%)Rejected-Finance 424 A B GANDHI NAGAR JAMMU AND KASHMIR 180004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Pyramid constructions L1 | Allied Technologies L4 | M/S GRD ENGINEERS L6 | M/S INOVISION ENTERPRISES L5 | M/S VIDYA ENTERPRISES L2 | M/s J.S Enterprises L7 | M/S ROMESH KUMAR SHAN L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for servicing/cleaning of complete indoor and out door unit of Split Type Air conditioner / window type AC and Inverter type Split AC of capacity 2.0 TR by means of adding cleaning solution with water. The cleaning of the condensor and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition and specified and as directed by Engineer-in-Charge. | 60 | Each | 500 ₹30,000 | 150 ₹9,000 Lowest | 490 ₹29,400 | 183 ₹10,980 | 200 ₹12,000 | 500 ₹30,000 | 220 ₹13,200 |
| 2.00 | M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron 4mm dia wire by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009.
Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. | 7 | Each | 5,000 ₹35,000 | 3,500 ₹24,500 | 4,500 ₹31,500 | 4,587 ₹32,109 | 3,000 ₹21,000 Lowest | 6,688.4 ₹46,818.8 | 3,150 ₹22,050 |
| 3.00 | S&F in replacement MCCB 4 pole of capacity 125 Amps AC 415 Volts Confirms to IS/IEC 60947-2, Breaking capacity 16 KA, positive isolation, thermal magnetic release, adjustable overload 70-100%, adjustable short circuit 5-10 In Make : as per existing panel or its equivalent in Siemens/Legrand/ Schineder/ Hegar/ ABB all as specified and directed. | 4 | Each | 3,200 ₹12,800 Lowest | 4,000 ₹16,000 | 5,000 ₹20,000 | 4,128 ₹16,512 | 4,000 ₹16,000 | 5,000 ₹20,000 | 4,050 ₹16,200 |
| 4.00 | Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 40 to 100 Amp of 4 poles and current carrying capacity in the DB complete with connection testing and commissioning. | 6 | Each | 700 ₹4,200 Lowest | 1,850 ₹11,100 | 2,000 ₹12,000 | 1,101 ₹6,606 | 2,000 ₹12,000 | 2,360.74 ₹14,164.44 | 2,200 ₹13,200 |
| 5.00 | Supply only copper wire 1.5 Sqmm FRLS green/red colour single core complete all as specified and directed. Make- Anchor/Havells/Polycab | 270 | RM | 25 ₹6,750 | 20 ₹5,400 | 20 ₹5,400 | 26 ₹7,020 | 25 ₹6,750 | 15 ₹4,050 Lowest | 20 ₹5,400 |
| 6.00 | Supply and only copper wire 2.5 Sqmm FRLS green/red/black colour single core complete all as specified and directed. Anchor/Havells/Polycab | 360 | RM | 42 ₹15,120 | 32 ₹11,520 | 20 ₹7,200 Lowest | 46 ₹16,560 | 35 ₹12,600 | 20 ₹7,200 Lowest | 30 ₹10,800 |
| 7.00 | Supply & Fixing PVC insulated sheathed service wire twin core 10 Sqmm aluminium stranded conductor 1100 volts grade including taking down old unserviceable one. | 540 | RM | 20 ₹10,800 | 15 ₹8,100 Lowest | 45 ₹24,300 | 98 ₹52,920 | 15 ₹8,100 Lowest | 51.1 ₹27,594 | 20 ₹10,800 |
| 8.00 | M&L for Shifting of Split type AC/ Window type AC capacity upto 2 Ton , including submain all electrical items and drilling, making good on surface of PCC concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 Wing area and 256 SU Kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by Engineer-in-Charge. | 75 | Each Job | 500 ₹37,500 | 200 ₹15,000 Lowest | 655 ₹49,125 | 1,101 ₹82,575 | 500 ₹37,500 | 650 ₹48,750 | 550 ₹41,250 |
| 9.00 | Supply of Labour only for attending and rectification of complaints for maintenance for Split AC/Window AC /hot & cold air conditioner/Dual inverter Air conditioners of any capacity and make installed in various locations of 23 wing AF Jammu and 256 SU Kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by Engineer In Charge.
Note: (a) Contractor has to employ highly skilld Refrigerator Mechanic with helper and necessary T&P for attending complaints of Ref and AC failing which recovery shall be made at two times of quoted rate.
(b) Rate quoted shall be inclusive of transport from AF Station to work shop & back shifting within permises.
( c) Any parts shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule. | 200 | Each job | 200 ₹40,000 | 50 ₹10,000 Lowest | 350 ₹70,000 | 183 ₹36,600 | 200 ₹40,000 | 400 ₹80,000 | 250 ₹50,000 |
| 10.00 | Supply only blower motor complete suitable for window /split type AC upto 2.0 Ton as on site all as specified and directed by Engr-in-Charge. | 25 | Each | 500 ₹12,500 Lowest | 1,650 ₹41,250 | 1,390 ₹34,750 | 1,468 ₹36,700 | 1,000 ₹25,000 | 1,400 ₹35,000 | 1,200 ₹30,000 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
7 Mar 2026, 6:00 pmClosed
GE AF JAMMU
GE AF JAMMU
REPAIR REPLACEMENT TO CERTAIN AIR CONDITIONING and MISC E M WORK IN OTM and TECH AREA UNDER GE AF JAMMU
2026_MES_752633_1
GEAFJ-85/2025-26
Open Tender
Civil Works
Item Rate
180 days
Jammu
Please refer tender doc
8 documents required · 8 mandatory
₹500
GE AF JAMMU
₹40,000
Yes
14 May 2026
13 Feb 2026
13 Mar 2026
13 Feb 2026
7 Mar 2026
28 Feb 2026
Material and labour for servicing/cleaning of complete indoor and out door unit of Split Type Air conditioner / window type AC and Inverter type Split AC of capacity 2.0 TR by means of adding cleaning solution with water. The cleaning of the condensor and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition and specified and as directed by Engineer-in-Charge.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron 4mm dia wire by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
S&F in replacement MCCB 4 pole of capacity 125 Amps AC 415 Volts Confirms to IS/IEC 60947-2, Breaking capacity 16 KA, positive isolation, thermal magnetic release, adjustable overload 70-100%, adjustable short circuit 5-10 In Make : as per existing panel or its equivalent in Siemens/Legrand/ Schineder/ Hegar/ ABB all as specified and directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 40 to 100 Amp of 4 poles and current carrying capacity in the DB complete with connection testing and commissioning.
Supply only copper wire 1.5 Sqmm FRLS green/red colour single core complete all as specified and directed. Make- Anchor/Havells/Polycab
Supply and only copper wire 2.5 Sqmm FRLS green/red/black colour single core complete all as specified and directed. Anchor/Havells/Polycab
Supply & Fixing PVC insulated sheathed service wire twin core 10 Sqmm aluminium stranded conductor 1100 volts grade including taking down old unserviceable one.
M&L for Shifting of Split type AC/ Window type AC capacity upto 2 Ton , including submain all electrical items and drilling, making good on surface of PCC concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 Wing area and 256 SU Kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by Engineer-in-Charge.
Supply of Labour only for attending and rectification of complaints for maintenance for Split AC/Window AC /hot & cold air conditioner/Dual inverter Air conditioners of any capacity and make installed in various locations of 23 wing AF Jammu and 256 SU Kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by Engineer In Charge. Note: (a) Contractor has to employ highly skilld Refrigerator Mechanic with helper and necessary T&P for attending complaints of Ref and AC failing which recovery shall be made at two times of quoted rate. (b) Rate quoted shall be inclusive of transport from AF Station to work shop & back shifting within permises. ( c) Any parts shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule.
Supply only blower motor complete suitable for window /split type AC upto 2.0 Ton as on site all as specified and directed by Engr-in-Charge.
Supply only outer unit condenser fan motor with fan suitable for window type AC up to 2 Ton as on site.
Supply only plastic air filter suitable for Split AC Indoor unit AC upto 2 TR as on site.
Supply only wiring kit suitable for split AC and window Type AC upto 2 Ton.
Supply only condenser fan motor complete with fan suitable for out door unit of split type Air conditioner upto 2 Ton as on site.
Supply only blower for indoor unit of Split AC upto 2 Ton AC as on site.
Supply and fix Power control Board ( PCB ) for window type /Split type AC up to 2 Ton . Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply and fix Power control Board ( PCB ) for split AC indoor unit dual inverter/Hot and cold AC up to 2 Ton . Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply and fix Power control Board ( PCB ) for split AC out door unit dual inverter/Hot and cold AC up to 2 Ton . Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Relay/Contractor suitable for Split Type AC upto 2 Ton.
Supply only foaming insulator for AC suction/ cooling line,7/8" ( Approx - length 5.9 ft).
Suppy and fixing suction and dischagre valve suitable for split Type Air conditioner out door unit as per sample.
Supply and fixing as in replacement ( hermetically ) uncut sealed compressor unit rotatry type for Split Type Air conditioner for the following capacity including gas charging: -
Capacity 2 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Capacity 1.5 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to Split Type air Conditioners for the following capacity. Note-(i)Gas charging at one location will be counted and paid as one job inspite of charging it number of times at same location.(ii) Necessary T & P for gas charging of appliances for mechanic shall be arranged by the contractor at his end without any extra cost to the department.
Capacity 2 TR.
Capacity 1.5 TR.
Supply and fixing as in replacement ( hermetically ) uncut sealed compressor unit reciprocating type for window Type Air conditioner for the following capacity including gas charging: -
Capacity 2 TR. Make- Kirloskar, Tecumseh, As on site.
Capacity 1.5 TR. Make- Kirloskar, Tecumseh, As on site.
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to Window Type air Conditioners for the following capacity. Note-(i)Gas charging at one location will be counted and paid as one job inspite of charging it number of times at same location. (ii) Necessary T & P for gas charging of appliances for mechanic shall be arranged by the contractor at his end without any extra cost to the department.
Capacity 2 TR.
Capacity 1.5 TR.
Repair to Power control Board (PCB) of inverter type/hot and cold Split type AC/Window AC for the following capacity: -
Capacity 2 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Capacity 1.5 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
S & F By Flushing to walls MCB distribution board double door 240 volts 2 way making good to disturbed surfaces of floors walls including taking down the old DBs etc. Make- Legrand/Havells/L&T/Indoasian
S&F MCB SPN upto 32 Amps, 240 Volts complete including taking down old unserviceable .Make-Legrand/Havells/Indoasian
Supply for industrial type metal socket enclosure with 240 volt MCB 20 Amps, with metal plug top complete all as specified . Make ABB/Legrand/ L&T/Havells
Supply & Fixing PVC insulated sheathed service wire twin core 06 Sqmm aluminium stranded conductor 1100 volts grade incl taking down old unserviceable one.
S&F copper pipe 5/8" and removing old u/s copper pipe complete all as specified and directed by Engineer-in-charge.
S&F copper pipe 1/4" and removing old u/s copper pipe complete all as specified and directed by Engineer-in-charge.
Supply only the following capacitors to incorporate against repairable summer appliances Window / Split Type AC's : -
Running capacitor 45 MFD. Make- Epcos.
Running capacitor 50 MFD. Make- Epcos.
Running capacitor 4 MFD. Make- Epcos , Havells.
Running capacitor 6 MFD. Make- Epcos , Havells.
Running capacitor 10 /15 MFD. Make- Epcos , Havells.
Starting capacitor 100 / 120 MFD capacity Make- Tesla, Chezco slvika, Epcos.
M&L for sub main wiring with two run of 6.00 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLS cable in and including electrical grade PVC conduits of desired colour not less than 1.2 mm thick and of 25 mm dia & 6.00 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one. (Note : Two runs of copper cable, one run of earth wire, one run of PVC conduit shall be measured as one unit.) Make of wire-- Finolex/Havells/Plaza.
M&L for sub main wiring with two run of 4.00 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLS cable in and including including PVC cassing capping with fitting and accessories & 4.00 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one. (Note : Two runs of copper cable, one run of earth wire, one run of PVC casing caping shall be measured as one unit.) Make of wire-- Finolex/Havells/Plaza.
Supply and fixing Switch socket combination two in one multipurpose suitable for 3 pin 5 amp and 16 amp flush type universal, fixed in repairs, complete all as specified.
Supply and fixing Plug top 15 Amps capacity, fixed in repairs complete all as specified and as directed.
Supply and fixing Plug top 5 Amps capacity fixed in repairs complete all as specified and as directed.
Rewinding transformer of voltage stabalizer of capacity 03 KVA with existing guage copper winding of capacity range 90 to 280 Volts complete all as specified and as directed.
Rewinding transformer of voltage stabalizer of capacity 05 KVA with existing guage copper winding of capacity range 90 to 280 Volts complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to refrigerator of following capacities: - Note :- Refrigerant gas for charging of equipment compressor shall be provided by the firm and cost thereof shall deemed to be included in the unit rate quoted against this Item.
Capacity 170 Ltrs.
Capacity 285 to 310 Ltrs.
Supply and fixing as in replacement hermetically sealed compressor unit for refrigerator: -
Capacity 170 Ltrs. Make- Godrej/GMCC/Blue star.
Capacity 280/310 Ltrs. Make- Godrej/GMCC/Blue star.
Supply and fix wall mounted stand for mounting of outer unit of split ac made of heavy duty GI Steel of size upto 2.0 Ton with angle height 450 mm and bracket length 485 mm complete all as specified and directed.
Supply and fix 5 metre transparent drain pipe for split ac and window ac leak resistant all as specified and directed.
Supply & fixing in replacement of indoor type unit split Air conditioner electric driven single phase 220 volts of cap upto 2.0 TR Cold type complete with all accessories as per existing make and model.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
TENDER85.pdf
Tender Documents • 1.50 MB
BOQ_843001.xls
BOQ • 1.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .