Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.6 LAccepted-AOC | L1 | Accepted-AOC The lowest and negotiated tenderer | |
| 2 | Rejected-Technical COIMBATORE 641015 | - | Rejected-Technical Unsuccessful tenderer | |
| 3 | Rejected-Technical | - | Rejected-Technical Unsuccessful tenderer |
Tender Value
Refer Docs
EMD Value
₹36,300
Closing Date
20 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER, NORTH CIRCLE, TNPHC LTD.,
The Superintending Engineer/North Circle No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem - 636 006.
Providing Additional works for conversion of existing Sub Jail into District Jail at Tiruppur in Tiruppur District
2021_TNPHC_190909_1
SE/NC/DB/1239/2020
Open Tender
Civil Works
Lump-sum
240 days
Tiruppur in Tiruppur District
Refer the tender documents
6 documents required · 6 mandatory
₹0
₹36,300
20 Feb 2021
11 Jan 2021
22 Jan 2021
11 Jan 2021
20 Jan 2021
11 Jan 2021
90 days
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
1.3 : Earth work excavation in soft disintegrated (including refilling) a. 0 to 2 mt.
2.6: Supply and Filling of 40mm HBSJ
2.7: Supply and Filling of 20mm HBSJ
30 : Ellispattern
37.1 : White washing 3 coats (slaked)
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
Electrical arrangements 73.1 : 6 way - D.B
74 : Charges for fixing of "Fan"
81: Supplying and fixing of best country wood meter cupboard
112 : S & F of Exhaust Fan 300 mm dia
ANNEXURE 2.1.3 : Filling crushed stone sand
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.2.1 : P.C.C. 1:2:4 for Foundation & Basement and other similar works (using crushed stone sand)
6.2.1 : Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand)
8.1.1.1 : Standardised concrete Mix M20 Grade concrete. (using crushed stone sand) a) In Foundation and Basement
b) In Ground Floor
d) In Second Floor.
9.2.1 : Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand) a. In Ground Floor
10.2.1 : Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.) (using crushed stone sand) b. In Ground Floor
d. In Second Floor
11.2.1 : Brick Partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 75 mm tk (B.P.) (using crushed stone sand) a. In Ground floor
14.1.1.I : Precast Cupboard slab 20 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Ground floor
14.1.1.II : Precast cupboard slab 40 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Foundation & basement
b. In Ground floor
18.1 : Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam,Raftbeam,Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
21.6.1 : R.C.C.Door frames of size 100 x 75mm with one edge grooves size 't' x 20 mm using standardised concrete mix M20 grade. (using crushed stone sand) b. 1000 x 2100mm
22.3.3 : TW frame & TW styles & rails with BWR double leaf shutters for cup board/ wardrobes including one coat primer & two coats enamel paint.
23.1.1 : TW styles & rails with 9mm thick BWR single leaf shutters with brass screws following size b) 1000 x 2100 mm
23.5 : Supply & Fixing of MS door a. 1000 x 2100 mm
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand)
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 : Floor ceramic tiles (antiskid) using Grout (Tile Joint Filler) (using crushed stone sand)
31.2.1 : Finshing the top of Terrace floor with one course of solar reflective Ceramic tiles without base concrete
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand)
34.1 : Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand)
35.1.1 : Plastering 1:3, 12mm with WPC (using crushed stone sand)
35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand)
38.6 : One coat white cement for new walls and other similar works.
38.7 : Plastic Emulsion PAINT including primer for outer walls
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
52.4 : 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.3.2: S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - In G.F.(using crushed stone sand)
57.1.1 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" Trap
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.5 : PVC (SWR) pipe with ISI mark - type 'A' for Ventilating shaft with cowl
60.1 : PVC Nahani trap (4way/2way)
61.2 : Supplying and laying and loose jointing the following dia stone ware pipes with ISI mark Superior variety a. 100 mm dia S.W. pipe
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 160 mm UPVC Non Pressure pipe
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
65.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
75.1.2 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
105.1 : 4 x 4 Sq mm copper PVC insulated unsheathed single core cable for 3 phase EB service connection
361 : Concrete Designer Tiles flooring (using crushed stone sand)
361.5.1: Vitrified Tiles flooring (ivory) (using crushed stone sand)
799 : Two coat of OBD over one coat white cement for inner walls
ANNEXURE II A1) Supply and delivery, fixing of 0.47mm Colour bhare Galvanium sheet roof of approved quality
A2) Supplying and fixing of 'I' section beam 150 x 80mm and 'L' angle size of 75 x 60 x 6 mm & 16mm dia rod 12" distance for alround the weld mesh area. a) 'I' Section (150 x 80mm)
b) 'L' angle alround (75 x 50 x 6mm)
c) 16mm dia MS Square rod
A3) Supplying, fabricating and placing in position of Mild steel weld mesh of size 7.5 x 2.5 cm in 10 gauge steels for reinforcement for all floors.
A4) Supplying and fixing in position of UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) for all sizes
A5) Painting old walls with one coat of ready mixed Plastic Emulsion paint
A6) Painting old walls with two coats of Oil Bound Distemper of approved brand
A7) Through scrapping the old plastered surface
A8) Supplying and fixing of precast reinforced cement concrete rings of 50mm thickness 1200mm dia and 300mm depth
A9) Supplying and fixing of precast reinforced cement concrete slab of 40mm thickness 1500mm dia top cover slab
A10) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (open wiring) a. Light point with ceiling rose
b. Light point without ceiling rose (open wiring)
A11) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.(open wiring)
A12) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.(open wiring) For Admin block & Community centre
A13) Supplying and fixing of Bulk head fittings suitable for 12W bulb.
A14) Supplying and fixing of 12 Watts LED bulbs
A15) Supplying and fixing of 4' long 18 Watts LED tube light with fittings
A16) Supplying and fixing of 9 Watts LED bulbs
A17) Supplying and fixing of 72 Watts LED street light with fittings
A18) Supply, delivery and laying of following dia GI pipe "B" class in Below GL a) 100mm dia GI pipe
A19) Dismantling the damaged brick works of cement mortar in all floors without affecting the adjacent structures including the cost of required tools and plants a) Under 3m height
A20) Dismantling the existing damaged Reiforced cement concrete with out affecting the adjacent structures, including the hire charges of tools and plants etc.
A21) Dismantling the existing Floor finishing and dadooing walls in cement mortar with mosaic tiles/glazed tiles/cuddapah slabs etc.
THIRUCHENDUR MURUGAN BUILDERS
M/s.V.S.D CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_227921.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .