Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.3 CrAdmitted-Finance 2 CORRIGENDUM ADDENDUM 01 DATED 11 01 2024 3 YOUR TENDER SUBMITTED ON 15 01 2024 ON E TENDER WEBSITE 4 CORRIGENDUM ADDENDUM 02 DATED 06 02 2024 5 YOUR PRICE BID OPENED ON 06 02 2024 ON E TENDER WEBSITE | -1.51% | ₹4.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.8 Cr+₹1.5 Cr (33.4%)Admitted-Finance U 110 FIRST FLOOR SAPNA ARORA U 110 1ST FLOOR SURYA ARCADE MAIN VIKAS MARG DELHI 110092 SHAKARPUR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | +31.42% | ₹5.8 Cr+₹1.5 Cr (33.4%) | L2 | Admitted-Finance |
| 3 | L3₹6.0 Cr+₹1.7 Cr (39.1%)Admitted-Finance | +37.00% | ₹6.0 Cr+₹1.7 Cr (39.1%) | L3 | Admitted-Finance |
| 4 | L4₹6.0 Cr+₹1.7 Cr (39.3%)Admitted-Finance | +37.17% | ₹6.0 Cr+₹1.7 Cr (39.3%) | L4 | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Others-The EMD of agency not as per DNIT Clause No. 9-10 |
Tender Value
₹4.4 Cr
EMD Value
₹8.8 L
Closing Date
8 Jul 2026, 11:00 amClosed
Hospital Engineer (Electrical)
Electrical Division, First floor, School of Public Health,Sector 12, PGIMER, Chandigarh.
Upgradation New hybrid Passive Active Power Factor correction for 10 nos. 11 kV Substations, PGIMER, Chandigarh
2026_PGIME_909430_1
PGI/Engg./Elect./2026-27/07
Open Tender
Electrical Works
Percentage
180 days
Electrical Division, First floor, SPH, PGI, CHd
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹8.8 L
Yes
SPH Building, PGI, Chandigarh
13 Aug 2026
20 May 2026
9 Jul 2026
20 May 2026
8 Jul 2026
20 May 2026
28 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Hybrid Power Factor Correction Panel | |||||
| 2Design, Supply, Installation, Testing & commissioning of cubicle type Semi compartmentalized floor mounted free-standing type with separation system Hybrid APFC panel. Hybrid panel should have, 433V, 50HZ, 3 phase 4 wire/3 Wire supply. Active part should be modular and have modules of 50/100 A or mentioned in specs, AHF must be intrinsic design of voltage sourced IGBT based intelligent 3-Level topology with 12 IGBT's with Programmable Microprocessor Controller to maintain Power Factor, Harmonics & Unbalancing. The passive part must be as per IS: 16636:2017 or IEC 61921 & 61439 Part -I & II (OEM Factory made) with valid temperature rise test from CPRI/ASTA-ERDA. The passive part must be as per the duly housed in epoxy powder coated 2mm thick CRCA steel sheet semi compartmentalized enclosure free standing type with all supports, accessories, switch gears, capacitors, control gears, protections, wiring, interconnections, control MCBs, controllers, reactors, etc. | |||||
| 2.1 | All Major components like Capacitor, Reactors, Controller, Capacitor Duty Contactor and AHF module should be of single manufacturer for better operation and maintenance practice. All capacitors should be ISI/BIS Marked with valid CML Number on each name plate. All detuned reactors shall be with CE marking and ROHS compatible, IEC-60529, Electromagnetic standard FCC 15J,Class-A IEC61000-4, ANSI IEEE Standard 519-2014 (Harmonics LIMITS) items like capacitors should have valid CPRI type tested as per the relevant IS. Hybrid Panel should be IP-42 and duly housed in epoxy powder coated 2mm thick CRCA sheet steel semi compartmentalized enclosure free standing type with all supports, accessories, switch gears, control gears, protections, wiring, interconnections, control MCBs and maintain PF,I-THD,V-THD as per IEEE 519-92 etc. as required. Also complete in all respects & having its main components as bellow along with all other standard components ,circuitry & specifications as required: | - | - | - | - |
| 2.3 | Hybrid Power Factor Correction Panel AHF(300 Amp) + (APFC) 450 KVAR | - | - | - | - |
| 3INCOMMER | |||||
| 3.1 | S.I.T.C of 1 No.of 1250 A 4P Electrically Operated Drawout (EDO) type ACB with Ics=Icu=Icw=50 KA having Microprocessor based releases for overload, S/C, O/C and earth fault protection. | - | - | - | - |
| 3.2 | 1 No. of Display meter with compatible RS 485 ports. | - | - | - | - |
| 3.3 | 3 No.of Phase Indicating & ON-OFF LED Lights 230 V. | - | - | - | - |
| 3.4 | 1 Set. of Ammeter - digital 3 Phase. | - | - | - | - |
| 3.5 | 6 No. of MCB 6A-SP-10kA-C-Curve. | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.86 MB
BOQ_955824.xls
BOQ • 0.57 MB
noticeextend.pdf
PDF • 0.33 MB
prebidnotice.pdf
PDF • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .