| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹26.9 L+₹58,400 (2.22%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹27.6 L+₹1.3 L (4.81%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹39.3 L+₹13.0 L (49.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/S SHRINATH CONTRACTION L3 | Shiva Enterprises L2 | M/S DEVENDRA KUMAR GUPTA L4 | BUILDTECH ASSOCIATES L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Checking of LT Panel/Motor/Pump set for detecting any kind of fault and attending the fault immediately at any time round the clock and carry out certain repairs required as per site requirement and replacing of worn out parts by expert engineer complete all as direced.
Note :- Unit rate includes detecting of any kind of fault in LT Panel/Motor/Pump set only and cost of replacement of worn out parts shall be measured and paid separately under respective items of BOQ. | 25 | Each Job | 500 ₹12,500 Lowest | 500 ₹12,500 Lowest | 790 ₹19,750 | 1,300 ₹32,500 |
| 2.00 | Supply and fix in replacement starter for 2 HP to 3 HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54, 230 Volt, Single Phase, with inbuilt amp & voltage meter, Rugged MU-2P contactor with wide band voltage, MU-2P Relay for reliable overload protection, heavy duty START & RUN condensers with FRLS internal wiring, and class H insulation complete all as specified and directed by engr-in-charge. | 10 | Each | 3,000 ₹30,000 | 2,500 ₹25,000 Lowest | 4,590 ₹45,900 | 3,500 ₹35,000 |
| 3.00 | Supply and fix in replacement Direct online starter for 5HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54,415 Volt, extended wide band coil with FRLS internal wiring, star type-Air break and class H insulation complete all as specified and directed by engr-in-charge. | 2 | Each | 5,000 ₹10,000 | 3,500 ₹7,000 Lowest | 7,590 ₹15,180 | 7,000 ₹14,000 |
| 4.00 | Supply and fix in replacement fully automatic star delta starter for 10 HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54,3 phase, 415 Volt, 50 Hz, relay range 6-10 amps type MK1, with FRLS internal wiring and class H insulation complete all as specified and directed by engr-in-charge. | 4 | Each | 8,500 ₹34,000 | 8,000 ₹32,000 | 14,990 ₹59,960 | 6,500 ₹26,000 Lowest |
| 5.00 | All as per item No 4 above but 12.5 HP | 4 | Each | 10,500 ₹42,000 | 12,000 ₹48,000 | 16,990 ₹67,960 | 6,500 ₹26,000 Lowest |
| 6.00 | All as per item No 4 above but 15 HP | 4 | Each | 12,500 ₹50,000 | 14,000 ₹56,000 | 17,990 ₹71,960 | 6,500 ₹26,000 Lowest |
| 7.00 | All as per item No 4 above but 20 HP | 5 | Each | 15,000 ₹75,000 | 16,000 ₹80,000 | 19,990 ₹99,950 | 9,000 ₹45,000 Lowest |
| 8.00 | All as per item No 4 above but 25 HP | 2 | Each | 15,000 ₹30,000 | 18,000 ₹36,000 | 21,990 ₹43,980 | 10,000 ₹20,000 Lowest |
| 9.00 | Supply and fix in replacement 3 Pole Power contactors type MNX with AC coil, rating 32 Amps, conforming IS/ IEC 60947-4-1, IP-20,415 Volt, snap fit construction, nut retaining washer for quick termination and class H insulation complete all as specified and directed by engr-in-charge. | 7 | Each | 1,000 ₹7,000 Lowest | 1,600 ₹11,200 | 3,290 ₹23,030 | 1,500 ₹10,500 |
| 10.00 | All as per item No 9 above but 95 Amp | 4 | Each | 4,500 ₹18,000 | 4,000 ₹16,000 | 16,590 ₹66,360 | 1,800 ₹7,200 Lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
11 May 2026, 6:00 pmClosed
Maj Dinoop Kumar
GE (W) Agra
REPAIR/REPLACEMENT OF PUMPS, MOTORS, SUBMERSIBLE PUMP SETS ALONGWITH ALLIED WORKS TO WATER/SEWAGE SUPPLY INSTALLATION UNDER AGE E/M (WEST) OF GE (WEST) AGRA
2026_MES_761145_1
8012/1165/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Agra
Please refer tender document
9 documents required · 9 mandatory
₹500
GE (West) Agra
₹60,000
11 Jul 2026
21 Apr 2026
18 May 2026
21 Apr 2026
11 May 2026
5 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Checking of LT Panel/Motor/Pump set for detecting any kind of fault and attending the fault immediately at any time round the clock and carry out certain repairs required as per site requirement and replacing of worn out parts by expert engineer complete all as direced.
Note :- Unit rate includes detecting of any kind of fault in LT Panel/Motor/Pump set only and cost of replacement of worn out parts shall be measured and paid separately under respective items of BOQ. | 25 | Each Job | - | - |
| - | Supply and fix in replacement starter for 2 HP to 3 HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54, 230 Volt, Single Phase, with inbuilt amp & voltage meter, Rugged MU-2P contactor with wide band voltage, MU-2P Relay for reliable overload protection, heavy duty START & RUN condensers with FRLS internal wiring, and class H insulation complete all as specified and directed by engr-in-charge. | 10 | Each | - | - |
| - | Supply and fix in replacement Direct online starter for 5HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54,415 Volt, extended wide band coil with FRLS internal wiring, star type-Air break and class H insulation complete all as specified and directed by engr-in-charge. | 2 | Each | - | - |
| - | Supply and fix in replacement fully automatic star delta starter for 10 HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54,3 phase, 415 Volt, 50 Hz, relay range 6-10 amps type MK1, with FRLS internal wiring and class H insulation complete all as specified and directed by engr-in-charge. | 4 | Each | - | - |
| - | All as per item No 4 above but 12.5 HP | 4 | Each | - | - |
| - | All as per item No 4 above but 15 HP | 4 | Each | - | - |
| - | All as per item No 4 above but 20 HP | 5 | Each | - | - |
| - | All as per item No 4 above but 25 HP | 2 | Each | - | - |
| - | Supply and fix in replacement 3 Pole Power contactors type MNX with AC coil, rating 32 Amps, conforming IS/ IEC 60947-4-1, IP-20,415 Volt, snap fit construction, nut retaining washer for quick termination and class H insulation complete all as specified and directed by engr-in-charge. | 7 | Each | - | - |
| - | All as per item No 9 above but 95 Amp | 4 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
Tender.pdf
Tender Documents • 0.56 MB
BOQ_852585.xls
BOQ • 2.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .