Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.1 L+₹1.6 L (11.1%)Rejected-Finance | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹17.9 L+₹3.4 L (23.6%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Tender fee and EMD is not paid by the bidder. MSME Udyog Aadhar Registration Certificate submitted for exemption is found invalid. | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Meeting NIT Eligibility Criteria |
Tender Value
₹19.6 L
EMD Value
₹39,124
Closing Date
3 Aug 2022, 2:30 pmClosed
Asstt.General Manager (E-E)
Airports Authority of India, Engineering Electrical Wing, Room No.202/16, ATS Complex, Sutar Pakhadi Road, Andheri (East), Mumbai
A.C.M.C. of Airconditioning (15 TR and 11.0 TR package units, 8.0 TR Ductable, 3.0 TR,2.0 TR and 1.5 TR Split ACs) at various locations in the Operational Area of C.S.M.I.Airport, Mumbai during 2022-23 to 2023-24.
2022_AAI_122950_1
MUM/ATS/ENGG-E/eNIT-06/2022-23
Open Tender
Electrical Works
Item Rate
731 days
Operational Area at CSMI Airport, Mumbai
As per NIT Criteria.
5 documents required · 5 mandatory
₹1,120
Yes
₹39,124
Yes
6 Sept 2022
20 Jul 2022
4 Aug 2022
21 Jul 2022
3 Aug 2022
21 Jul 2022
21 Jul 2022 - 3 Aug 2022
Amount
Annual comprehensive maintenance of 15 TR air cooled package precession AC units at (ELDIS-II RADAR Model No.PDX0062, Make: Emerson) including replacement of faulty compressor and providing all necessary consumables and spares parts like PCB card, bearings, belts, and also includes replacement of damage insulation, ducting, taping, etc., carrying out monthly servicing, painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions ( Annexure - 2 ) complete, etc. as required. The ACMC also includes Quarterly maintenance / health checkup by O.E.M. M/s.Emerson Precision Air Conditioners (Vertiv). a) First Year
Annual comprehensive maintenance of 15 TR air cooled package precession AC units at (ELDIS-II RADAR Model No.PDX0062, Make: Emerson) including replacement of faulty compressor and providing all necessary consumables and spares parts like PCB card, bearings, belts, and also includes replacement of damage insulation, ducting, taping, etc., carrying out monthly servicing, painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions ( Annexure - 2 ) complete, etc. as required. The ACMC also includes Quarterly maintenance / health checkup by O.E.M. M/s.Emerson Precision Air Conditioners (Vertiv). b) Second Year
Annual Comprehensive Maintenance of 11 TR Ductable package Air-conditioners of M/s. Blue Star make, located at new ASR/MSSR, Kalina including replacement of faulty compressor and providing all necessary consumables and spares parts like PCB card, bearings, belts and also includes replacement of damage insulation, ducting, taping, etc., carrying out monthly servicing, painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions ( Annexure - 2 ) complete, etc. as required. a) First Year
Annual Comprehensive Maintenance of 11 TR Ductable package Air-conditioners of M/s. Blue Star make, located at new ASR/MSSR, Kalina including replacement of faulty compressor and providing all necessary consumables and spares parts like PCB card, bearings, belts and also includes replacement of damage insulation, ducting, taping, etc., carrying out monthly servicing, painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions ( Annexure - 2 ) complete, etc. as required. b) Second Year
Annual Comprehensive Maintenance of 8.0 TR Ductable package inverter type Air-conditioners of M/s. Blue Star make, located at ELDIS - II RADAR including replacement of faulty compressor and providing all necessary consumables and spares parts like PCB card, bearings, belts and also includes replacement of damage insulation, ducting, taping, etc., carrying out monthly servicing, painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions ( Annexure - 2 ) complete, etc. as required. a) First Year
Annual Comprehensive Maintenance of 8.0 TR Ductable package inverter type Air-conditioners of M/s. Blue Star make, located at ELDIS - II RADAR including replacement of faulty compressor and providing all necessary consumables and spares parts like PCB card, bearings, belts and also includes replacement of damage insulation, ducting, taping, etc., carrying out monthly servicing, painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions ( Annexure - 2 ) complete, etc. as required. b) Second Year
Annual comprehensive maintenance of 3.0 TR Mega split/High wall airconditioners of M/s. Blue Star make located at Operational area including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out monthly servicing and also includes replacement of damage insulation, taping, etc., painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions ( Annexure - 2 ) complete, etc. as required. a) First Year
Annual comprehensive maintenance of 3.0 TR Mega split/High wall airconditioners of M/s. Blue Star make located at Operational area including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out monthly servicing and also includes replacement of damage insulation, taping, etc., painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions ( Annexure - 2 ) complete, etc. as required. b) Second Year
Annual comprehensive maintenance of 1.5 TR and 2.0 TR split airconditioners ( Inverter and Non Inverter Type) of Voltas/Carrier/Blue star make at different locations ( Annexure - 1 ) including replacement of faulty compressor and providing all necessary consumables and spares parts and also includes replacement of damage insulation, taping etc.carrying out monthly servicing, painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions ( Annexure - 2 ) complete, etc. as required. a) First Year
Annual comprehensive maintenance of 1.5 TR and 2.0 TR split airconditioners ( Inverter and Non Inverter Type) of Voltas/Carrier/Blue star make at different locations ( Annexure - 1 ) including replacement of faulty compressor and providing all necessary consumables and spares parts and also includes replacement of damage insulation, taping etc.carrying out monthly servicing, painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions ( Annexure - 2 ) complete, etc. as required. b) Second Year
Shifting and Re-Installation of Split type Airconditioners of capacity of 1.5 TR / 2.0 TR including Gas changing, Pressure Testing and Commissioning, etc. complete as required.
Shifting and Re-Installation of Split type Airconditioners of capacity of 3.0 TR including Gas changing, Pressure Testing and Commissioning, etc. complete as required.
Supply and fixing 20mm dia rigid PVC pipes along with necessary accessories & insulation on surface / recess for drain water outlets of AC units, etc. complete as required
Supply and fixing of copper refrigerant piping of size 1/2" and 1/4" comprising suction and discharge pipes complete with nitrile rubber insulation sleeves, brazing including providing of clamps, etc. complete as required.
Supply and fixing of copper refrigerant piping of size 5/8" and 3/8" comprising suction and discharge pipes complete with nitrile rubber insulation sleeves, brazing including providing of clamps, etc. complete as required.
Dismantling of existing 3.0/2.0/1.5 TR Split AC Units with acceerious including loading and un loading complete, etc. as required upto AAI store.
CHAITANYA SERVICES
Manish Electricals
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .