Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.6 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹73.3 L+₹1.2 L (1.64%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹80.5 L+₹8.4 L (11.7%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance Being not lowest tenderer | |
| 4 | L4₹84.1 L+₹12.0 L (16.6%)Rejected-Finance | L4 | Rejected-Finance Being not lowest tenderer | |
| 5 | L5₹85.0 L+₹12.9 L (17.9%)Rejected-Finance 13 29 304 3RD FLOOR EAST PATEL NAGAR OPP SIDDHARTHA HOTEL NEW DELHI 08 | NEW DELHI | NEW DELHI | DELHI | 110008 | L5 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
25 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Tughlakabad
HQ CWE (AF) Tughlakabad, New Delhi-110080
CONVERSION OF OH CABLES TO UG CABLES WITH ASSOCIATES WORKS AT AF STN GURGAON UNDER GE (AF) GURGAON NO.1
2023_MES_616210_1
CA NO. CWE/TKD/GUR/TOKEN-37 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Gurgaon No.1
As per NIT condistion
8 documents required · 8 mandatory
₹1,000
GE (AF) Gurgaon No.1
₹1.8 L
Yes
12 Dec 2023
29 Aug 2023
27 Sept 2023
29 Aug 2023
25 Sept 2023
18 Sept 2023
29 Aug 2023 - 11 Sept 2023
Amount
Supply ,fixing, erection and Instalation of hot dipped GI Octagonal pole of 9.00Mtr height with minimum dimension of Top section – 70mm dia, Bottom section– 150mm dia and 3mm thickness sheet, including Base plate, foundation bolts (4 nos with 3 nos of nuts and washers in each), single arm bracket for mounting the light fittings, bakelite sheet with one 6-32A SP 10KA, 240 V, 'B' curve MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection, Common templates minimum 1 for each 15 poles and with including following specifications complete all as specified and directed:- a) The pole shaft shall be made from sheet of High Tension Steel Conforming to grade S355JO. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The top loading i.e. area and the weight of fixtures are to be considered to calculate maximum deflection of the pole and the same shall meet the requirement of BS: 5649 Part VI 1982. b) The poles shall be hot dip galvanized as per relevant Indian standards with average coating thickness of minimum 70 micron. The galvanizing shall be done in single dipping. c) Design & casting of RCC Foundation incl TMT bars and formworks suitable for erection of poles as per manufacturers recommendation considering safe soil bearing capacity including supplying & casting foundation anchor plate and templates, foundation bolts manufactured from special steel along with nuts, washers etc as reqd incl necessary earthwork. The quoted rate shall be inclusive of the same. The Minimum requirement for Civil Foundations for the Lighting Pole are as follows:- (i) Depth of Foundation shall be minimum 1.2m. Mim 450mm shall be projected above ground level. (ii) Plan dimensions of footing considered is 900mm x 900mm having depth D=200 mm Minimum. (iii) Steel in foundation base in both directions in two layers considered is T 10 @ 150 mm c/c (iv) Grade of concrete to be used considered is M20 (1:1.5:3) and grade of reinforcement steel considered is Fe 500D and above. (v) Main vertical reinforcement in 450 mm x 450 mm size pedestal are considered with 6 nos. bars of 12mm dia bars (L-shaped-length of L-shall not be less than 300 mm) and shear reinforcement (stirrups) shall be 8mm dia bars at 150 mm c/c. (vi) 20NB Flexible HDPE Pipe of 1m length shall be embedded to draw the cable.
Contd from Item no. 1.... d) All octagonal pole shafts shall be provided with the rigid flange base plate of minimum dimension 250mm X 250mm X 16 mm (as per IS 2062) with provision for fixing 4 foundation bolts. The foundation bolts shall have grading of EN-8 grade with minimum size of M24 x750 mm long ‘J’ type or as per manufactures instructions. e) The single arm brackets shall be made of 40NB G.I heavy duty pipe with minimum 1000 mm long, bent at an angle of 120 degree, with necessary holding brackets, hold fasts and suitable to mount on pole having top dimension 70 mm. f) The door opening if available in the octagonal Poles will have of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. The pole shall be adequately strengthened at the location of the door to compensate for the loss in section. NOTE:- (i) The quoted rate shall be inclusive of above all aspects and provisions. (ii) The contractor shall submit purchse voucher of all the Poles. The Engr-in-Charge shall verify the same and fwd the defaced voucher for claimaing payment. Non-Submission may lead to non-payment. (iii) The Engr-in Charge shall keep the photographic evidence of all the foundational Plan duly numbered with Synthetic enamel Paint of size 10 cm in height.
Supply and fixing energy saving LED street light 70/72 Watt 230/240 Volt AC outdoor type new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with toughned glass and luminaire efficiancy of >110 lm/W and fitted with potted driver. The LED light should have minimum CCT(K) 5500 having bottom opening seperate driver compartment with IP 66 protection, impact resistance of IK07, PF more than 0.95,. The THD shall not be more than 10% alongwith all the necessary fittings and fixtures complete all as specified and directed. NOTE:- (i) The Contractor shall submit purchase voucher in original for claiming payment in RAR/Bill. (ii) The Contractor shall submit company warranty certificate of each light at site and GE shall ensure that these certificate is kept on record and will be forwarded to office of Accepting Officer at the time of Final Bill. Non- complinace of this note shall render non-payment against this item. (iii) The 1% of quoted amount of this item shall be kept reserved upto the defect liablity period. (iv) The quoted rate shall be inclusive of dismantling of existing street lights which shall be issued to contractor on Sch of Credit.
Dismantling of ACSR or AAC conductors complete all as specified and directed.
Dismantling of unserviceable concrete poles any size transporting to E/M store and stackingcomplete all as specified and directed.
Dismantling insulators any type and any size complete all as specified and directed.
M&L complete for drilling hole of dia 100 mm under hard standing /road in different location as per site requirement (between 03 mtr to 20mtr maximum) for laying of pipe for protection of cable etc by boring tool and without disturbing the top surface and making good the disturbed surface complete all as specified and directed.
Supply & laying of ISI marked GI pipe light grade 40 mm dia including fittings for cable protection complete all as specified and directed.
Supply and fixing PVC Insulated and PVC Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 1100 Volts conforming to IS: 694:2010 of size 1.5 sq mm 3 core 1100 Volts grade complete all as specified and directed. NOTE: - (i) The contractor shall submit Purchse Voucher for the Cable. The Engr-in-Charge shall allow payment only after verification of voucher and De-facing of the orginal voucher.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed.
NOTE for Item no. 10 to 16 (i) The cable shall be directly purchased from the Approved Cable Manufature or from his authorised dealer. The Make shall be approved by GE on recommendation of Engr-in-Charge. The Authorised dealer of Manufature shall got verified by Engr-in-charge before placing the bulk order. (ii) The contractor shall submit Purchase Voucher of each type of Cable. The Engr-in-Charge shall allow payment only after verification of voucher and De-facing of the orginal voucher. Non-submission may lead to non-payment. (iii) All the cable shall got indepent testing at site in presence of Engr-in-Charge, rep of contrator as per IS code. The report shall be made and signed by all the parties. The copy of report shall be fwd to office of Accepting Officer before laying of cable. (iv) The contractor shall submit Manufature Test Certificate during sample approval.
Excavating in trenches n exc. 1.5 m wide and n. exc 1.5 m in depth, foundation etc for shafts, well, cesspits , manholes, pier holes, Laying of cable etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft soil complete all as specified and directed.
Material and labour for Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing excavated material n.exc 50 M and depositing where directed at a level n.exc 1.5 M above starting point complete all as specified and directed.
M&L for sand cushioning in trenches for protection of LT under ground cable including punning and consolidation complete as sepecified and directed. Note:- Punned thickness of 18 CM shall measured only for payment.
Supply and laying well burnt sub class ‘B’ bricks size(230 x 115 x 75mm), locally available in trenches for protection of underground cable complete as sepecified and directed.
Supplying & fixing 8 Way Double door, SPN, sheet metal enclosures, MCB DB, 240V, on surface/recess. Complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing as required complete all as specified and directed
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 16-32 Amp current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of SPN 05-32Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
M& L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground(earthpit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead with 4mm dia with protection pipe 15mm GI Light grade PIpe by means of bolts, nuts and check nuts and washers of GI or steel all as shown in Electrical plate No 3 including earth work funnel with watering arrangement, wire mesh, GI pipe 20mm internal dia light grade buried directly vertical and adjacent to the electrode for watering , PCC pit 1:3:6 type C1 and RCC chamber cover in 1:2:4 type B1 of size 550 x 550mm with 8 mm dia TMT bar of 100mm C/C both ways wih MS Hooks of 10mm MS Bar including of returning, filling in and removal of surplus soil to a distance not exc 50 m as specified and directed including testing on completion. Note: The strip/wire upto 7.5mtr included in the quoted rate.
M& L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground(earthpit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip of 32 x 6 mm with GI Pipe 40mm Light grade for protection by means of bolts, nuts and check nuts and washers of GI or steel all as shown in Electrical plate No 3 including earth work funnel with watering arrangement, wire mesh, GI pipe 20mm internal dia light grade buried directly vertical and adjacent to the electrode for watering , PCC pit 1:3:6 type C1 and RCC chamber cover in 1:2:4 type B1 of size 550 x 550mm with 8 mm dia TMT bar of 100mm C/C both ways wih MS Hooks of 10mm MS Bar including of returning, filling in and removal of surplus soil to a distance not exc 50 m as specified and directed by Engr-in-charge including testing on completion complete all as specified and directed.. Note: The strip/wire upto 7.5mtr included in the quoted rate.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm, Outdoor type complete all as specified and directed. Note:- The contractor shall submit Purchase Voucher of the same and Engr-in-charge shall allow the payment after defacing the voucher duly verified.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm, Outdoor type complete all as specified and directed. Note:- The contractor shall submit Purchase Voucher of the same and Engr-in-charge shall allow the payment after defacing the voucher duly verified.
M&L Plain cement concrete (1:2:4), type C-2 using 40mm graded stone aggregate for pole coping of size (60x60x30)cm complete all as specified.and directed by Engr-in-charge complete all as specified and directed.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Schedule of Credit
Ridhi engineers and builders
M P TYAGI ENGINEERS AND CONTRACTORS
M/s GANJOO AND CO
Leo Air and Power Solution pvt Ltd.
M/S SURINDER KUMAR MAHAJAN
M/S Parshant Associates
M/S MG GROUP
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .