Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹41.3 LAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹48.3 L+₹5.4 L (12.6%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L-2 | Rejected-AOC L-2 | |
| 3 | Rejected-Technical A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | - | Rejected-Technical No, Not enlisted in eligible category. |
Tender Value
Refer Docs
EMD Value
₹98,500
Closing Date
6 Apr 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINT OF FIRE FIGHTING SYSTEM, STREET/SECURITY LIGHT AND OTHER CONNECTED WORKS AT JCB LAB METCALFE HOUSE AND KWC AREA UNDER GE I RND DELHI
2023_MES_575717_2
GE/RND-103/DLI/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, Cat-b(i),c(vi)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹98,500
Yes
27 Apr 2023
18 Mar 2023
8 Apr 2023
18 Mar 2023
6 Apr 2023
25 Mar 2023
Amount
M&L in replacement of MS ERW pipe of bore 150 mm confirming to IS-1239 PART-1, medium grade complete all as specified and directed.
M&L in replacement of MS ERW pipe of bore 100 mm confirming to IS-1239 PART-1, medium grade complete all as specified and directed.
M&L in replacement of MS ERW pipe of bore 80 mm confirming to IS-1239 PART-1, medium grade complete all as specified and directed.
M&L in replacement of MS ERW pipe of bore 50 mm confirming to IS-1239 PART-1, medium grade complete all as specified and directed.
M&L in replacement of MS ERW pipe of bore 25 mm confirming to IS-1239 PART-1, medium grade complete all as specified and directed.
S&F in replacement of SS (Stainless Steel) Single head landing valve with 80 mm nominal bore flanged inlet, SS spindle (IS : 6603) controlled 63 mm dia instantaneous female outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290 including fixing with anchor fastener and flanged tapping from wet riser complete all as specified and directed.
S&F in replacement of SS (Stainless Steel) double head landing valve with 80 mm nominal bore flanged inlet, SS spindle (IS : 6603) controlled 63 mm dia instantaneous female outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290 including fixing with anchor fastener and flanged tapping from wet riser complete all as specified and directed.
M&L for Hose box made of 18 gauge MS Sheet of size 800mm X 600mm X 250mm with double door with 4 mm thick plain glasses and door frame made of 16 gauge MS sheet duly painted fire red out side and brilliant white inside yard including taking out old unserviceable box complete all as specified and directed.
S&F in replacement of 63 mm dia instantaneous pattern SS (Stainless Steel) Short branch pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete all as specified and directed.
S&F in replacement of Non-percolating rubber reinforced lined fire hose pipe (as per IS : 636) Type-A of 63 mm dia and length as described below. The hose shall be rated for burst pressure of 35.7 Kg/Sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound & riveted to hose pipe with aluminum rivets & 1.5 mm GI wire. (For Internal Hydrant & External Hydrant) complete all as specified & directed.
S&F in replacement of Cast Iron Air Valves with single air Outlets, conforming to IS - 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia complete all as specified and directed.
M&L in replacement of Non Return Sluice Valve of dia 100 mm confirming to IS-5312 PART-2, complete all as specified and directed.
M&L in replacement of Non Return Sluice Valve of dia 150 mm confirming to IS-5312 PART-2, complete all as specified and directed.
S&F sluice valve 80 mm bore class-1 ISI marked confirming to IS-14846 flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheet at top complete with nuts, bolts, washers and rubber gasket including jointing and testing including taking out old unserviceable sluice valve complete all as specified and directed.
S&F sluice valve 100 mm bore class-1 ISI marked confirming to IS-14846 flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheet at top complete with nuts, bolts, washers and rubber gasket including jointing and testing including taking out old unserviceable sluice valve complete all as specified and directed.
S&F sluice valve 150 mm bore class-1 ISI marked confirming to IS-14846 flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheet at top complete with nuts, bolts, washers and rubber gasket including jointing and testing including taking out old unserviceable sluice valve complete all as specified and directed.
S&F sluice valve 200 mm bore class-1 ISI marked confirming to IS-14846 flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheet at top complete with nuts, bolts, washers and rubber gasket including jointing and testing including taking out old unserviceable sluice valve complete all as specified and directed.
S&F in replacement of swinging type First Aid hose reel in red color drum with 30 mtr long and 20 mm dia heavy duty rubber water hose, 20 mm dia gate gun metal valve stop cock, (IS:778, class - II) terminating with SS coupling & nozzle of 6 mm outlet with shut off valve confirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastener, bolts & nuts complete all as specified and directed.
S&F in replacement Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of two way 63 mm dia instantaneous type male coupling with built in check valve and 150 mm dia , flanged out let complete with all accessories complete all as specified and directed.
M&L in replacement addressable manual call point resettable type complete all as specified and directed.
S&F in replacement signage shop glow in dark FIRE EXIT sign board with man running arrow symbol and stair of dimension 12" x 6" X 8 mm decorative transparent acralic, including fixing arrangement complete all as specified and directed.
M&L in replacement of Pressure gauge 4"dial 0-14 kgs rating complete all as specified and directed.
S&F in replacement air cushioning tank 250mm dia x 1000 mm high with dished top, made of minimum 6mm thick MS pipe/plate complete with 20mm dia. Brass air valve (ball type), 20 mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accesories complete all as specified and directed.
S&F in replacement MS branch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090 complete all as specified and directed.
M&L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L provision of fire point with shade and accessories like as bucket, fire bitter, fire hook, digging tool with supporting angle 2.0 RM each of size 75mmx75mmx6mm thick, 1.5 RM -02 Nos horizontal bracing of size 75mmx75mmx6mm and both side 0.5 meter covered with MS sheet of minimum thickness 3mm & minimum covered area 1.5 Sqm of sheet with support of angle iron 50x50x5mm thick of 1.0 RM -02 Nos (one at each end) and providing of hooks 200 mm length of round bar minimum size 20mm-05 Nos including earth work, PCC and 02 coats of red paint on all surface & equipment as directed with 3 buckets of 10 ltrs MS sheet of minimum thickness 3mm and carrying handle 10mm dia and two Nos fire bitter and one No fire hook as directed including gaity (digging tool) with handle and base complete all as specified and directed.
M&L for laying of twisted 2 core 1.5 Sqmm shielded PVC insulated FPLR cable ISI Marked unsheathed cable copper conductor including taking out old unserviceable cable complete all as specified and directed.
S&F Rigid steel conduit, welded of 20mm diameter concealed/surface in wall/Ceiling /above false ceiling and all fixing accessories/ materials including taking out old unserviceable conduit complete all as specified and directed.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 0.4 mpa working pressure for 150 mm dia MS pipe complete all as specified and directed.
S&F Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and directed.
M&L for Yard hydrant Post / Stand Post 80mm Dia MS both flanged class of pipe type 1.5m Height as per IS complete all as specified & directed. Note:- Earth work and PCC required will be measured and paid separately under respective items.
Excavation in trenches in soft/loose not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out complete all as specified and directed.
All as per item Ser No. 32.00 above but in hard/dense soil.
Returning, filling and including spreading, leveling and watering and well ramming in layers not exceeding 25 cm to achieve desired compactness complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded machine crushed stone aggregate and finished the surface even and smooth without using extra cement as on brick pillars complete all as specified and directed.
Disconnection of existing HFC-227 ea (ISO Name) gas cylinder, transport upto the wokshop to carried out hydro test as per BS Norms after drain out of existing cylinder and refixing the same after hydro test on existing location complete all as specified and directed. Note:- Contractor shall be produced the authentic test certificates as directed & filling of gas shall be measured & paid under respective item of BOQ.
S&F in replacement of Hydro valve as suitable for HFC-227ea panel line complete all as specified and directed.
Supply & filling of HFC-227 ea gas complete all as specified and directed.
S&F in replacement of NOVEC-1230 gas flooding panel with auto & mannual interaction as per existing panel complete all as specified and directed.
M&l for repair to HFC-227ea gas flooding panel including programming complete all as specified and directed.
Checking and testing of the detector including cleaning and checking the functionality of detector complete all as specified and directed.
S&F detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed.
S&F in replacement of Response Indicator complete all as specified and directed.
S&F LED street light 90 watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 with all accessories including taking out old unserviceable street light complete all as specified and directed.
S&F Cable Junction outdoor type "SMC KIOSK box IP 66/67 " weather proof, of size 300x450x170 mm incl fixing of 05 Nos terminal connection 100Amp 4 Pole, and MCB 6-32Amps suitable for in and out connection of 4 core XLPE cable 16 -50 Sqmm fixed on pole including all accesories like GI clamps, 25x25mm, nut bolts, washer etc including taking out old unserviceable junction box complete all as specified and directed.
Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor with pump of capacity upto 7.5 HP from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair and back, re-installed after repair and replacement of all unserviceable parts including testing complete all as specified and directed.
Opening the electric induction motor of capacity upto 7.5 HP including taking down/out old burnt winding wire , cleaning the slots, rewinding the motor with super enamelled copper winding wire of existing gauge & weight etc. including all other insulating material to make it functional complete all as specified and directed .
S&F in repair DOL starter for 7.5 HP motor complete all as specified and directed
S&F in replacement of Detectors Complying with and type certified to EN-45 Addressable type smoke detector Photoelectric / Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed.
M&L for Repair/Servicing to Centrifugal motor and pump set 50 HP with greasing and replacement of elctrical terminal including painting complete all as specified and directed. (Main Fire fighting pump).
M&L for Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor of capacity 50 HP from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair Opening the electric induction motor including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc. including servicing to pump and all other insulating material to make it functional and back, re-installed after repair including testing complete all as specified and directed.
S&F in replacement of 150 mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set as per IS-13095 complete all as specified and directed.
S&F in replacement of 100 mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set as per IS-13095 complete all as specified and directed.
S&F in replacement of 50mm bore hand operated butterfly valve complete set.as per IS-13095 complete all as specified and directed.
S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
S&F in replacement steel waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, re-easing of fan kit, motor, water pump and connected accessories complete all as specified and directed.
M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint including preparation of surface complete all as specified and directed. Note : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.
S&F in replacement of desert cooler sub mersible water pump with electric motor single phase 230 volts 50Hz including lead, connecting & testing complete all as specified and directed.
S&F in replacement desert cooler fan motor,copper wound suitable for upto 450mm sweep including metal fan blades SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified and directed.
S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed.
S&F in replacement of body side panels made out of galvanised iron sheets of of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide primer & two coat of synthetic enamel paint complete with fixing of all spare complete all as specified and directed.
S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare complete all as specified and directed.
S&F in replacement of PTMT float valve assembly 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as specified and directed.
S&F new wood wool pad,(Khus Khas) set of three covered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specified and directed.
M&L for B check general servicing by authorised representative of manufacturer of DG set of capacity 750 KVA, replacement of oil filter, fuel filter, air filter, by pass filter cleaning of radiator with chemical after draining out engine/ lubrication oil, coolant flushing and cleaning of oil chamber after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment refixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof sollution, oil pan/ chamber gasket at the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer complete all as specified and directed.
M&L for repair of self starter 24 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 750 KVA complete all as specified and directed.
S&F in replacement of automatic battery charger with auto cut off suitable for charging of 2X12V 180AH batteries with all required necessary wiring complete all as specified and directed.
M&L in replacement for wiring complete to AMF panel for capacity upto 750 KVA of DG set including interlock system of AMF panel with existing size of copper wiring including proper connection and testing of DG Set complete all as specified and directed.
S&F in replacement of self starter 24 volts suitable for upto 750 KVA DG sets complete all as specified and directed.
Taking down the old unserviceable actuator from its position and S&F new actuator for 750 KVA DG Set complete all as specified and directed.
Opening the DG set of 750 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing all flexible/steel wire mesh type hose pipes including fuel pipe line , belts & Bearings including re-assembling the complete Parts and Testing complete all as specified and directed. Note :- Spare parts required for replacement shall be measured & paid under following item.
Supply only Piston ring and liner for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Head valve, Head Guide, Head sheet & Head seal for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Injector sleeves & Head gasket for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Packing Kit for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
M&L for repair of Head and fuel injector assembly complete for 750 KVA complete all as specified and directed.
M& L for repair of Turbo assembly complete for 750 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 750 KVA complete all as specified and directed.
Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold for DG sets 750 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
S&F in replacement fly wheel ring of DG Set of capacity 750 KVA complete all as specified and directed
M&L in repair radiator of 750 KVA DG set ,arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed.
Taking Down the AVR system and supply and fix new AVR system for DG set of capacity 750 KVA complete all as specified and directed
M&L in replacement of turbo chargers repairs kit suitable for DG set 100 KVA. to 180KVA complete all as specified and directed
Supply only Engine oil 20W/40 for DG Set complete all as specified and directed.
Supply only Coolant for DG Set complete all as specified and directed.
Supply only Cotton Cloth for cleaning of DG Set complete all as specified and directed.
M&L for Servicing to AMF panel of any size/make check all loose connection of end terminal, screw, Nut Bolts, thimble. Clean all electric / electronic parts by using CRC spray, checked contactor connections and its serviciebility , check all realy setting of AMF Panel and check all internal connections of AMF Panel including hinges and locking devices complete all as specified and directed.
S&F in replacement old unserviceable Battery Cells of 12 Volt 180 AH for 750 KVA DG set complete all as specified and directed.
S&F ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including taking out old unserviceable fan complete all as specified and directed Note: Old fan shall be deposted to E/M store yard.
S&F exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers including taking down old unserviceable exhaust fan complete all as specified and directed. Note: Old Exhaust fan shall be deposited to E/M store yard.
M&L for removing burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishing complete all as specified and directed. Note : Taking down for rewinding and refixing the fan after rewinding shall demmed to be included in quoted rates.
S&F in replacement of unseviceable LED surface mounting panel 2'×2' fitting 36W and making all electric connections and including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose complete all as specified and directed. Note : PLUTOSURFA CE2X2PLS42WLED857S of Havells or equivalent in Wipro/Phillips as approved by GE.
S&F in replacement of SPN DB 12 ways with 200 Amps rated busbar 240 volt double door complete all as specified and directed.
S&F in replacement of SPN DB 8 ways with 200 Amps rated busbar 240 volt double door complete all as specified and directed.
S&F in replacement of SPN DB 4 ways with 200 Amps rated busbar 240 volt double door complete all as specified and directed.
S&F in replacement of TPN DB 6 ways with 200 Amps rated busbar 415 volt double door complete all as specified and directed.
S&F in replacement of TPN DB 8 ways with 200 Amps rated busbar 415 volt double door complete all as specified and directed.
S&F in replacement of TPN DB 12 ways with 200 Amps rated busbar 415 volt double door complete all as specified and directed.
S&F in replacement of of sheet metal enclosure, SPN type with two pin & earth plug and socket Industrial type DB with and including one MCB SP, C Curve type of capacity 32 Amp, 10 KA complete all as specified and directed.
Supply and fix in replacement of 3 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
Supply and fix in replacement of 3 Pole MCCB, 125 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
Supply and fix in replacement of 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
Supply and fix in replacement of 4 Pole MCCB, 200 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
M&L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- (i) Any unserviceable items need to be replaced/gas charging etc shall be replaced & paid seperately under respective items. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to other location where directed for proper washing and servicing and refixing the same shall be deemed to be included in item rate quoted.
All as per item Ser No. 107.00 above but for split type AC/Inverter type AC 1.5/2.0 ton.
All as per item Ser No. 107.00 above but for split type AC/Inverter type AC 3.0 ton.
M&L for Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC including taking out the unserviceable Fan Motor from the AC, complete all as specified and directed.
All as per Item Ser No. 110.00 above but AC (Window/Split Type). 2.0 TR Capacity.
All as per Item Ser No. 110.00 above but AC (Window/Split Type). 3.0 TR Capacity.
M&L for rewinding Fan Motor of AC 1.5/2.0/3.0 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt winding, complete all as specified and directed.
M&L Air circular Blower Fan Motor of AC (Split Type), 1.5 /2.0/3.0TR Capacity including taking out unser-viceable Air circular Blower Fan Motor complete all as specified and directed.
M&L Air Filter suitable of AC (Window type) 1.5 /2.0/3.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and directed. Make :- USHA/UNIVERSAL
M&L Air Filter suitable of AC (Split type) 1.5 /2.0/3.0 TR Capacity including taking out unserviceable Air Filter complete all as specified and directed. Make :- USHA/UNIVERSAL
M&L Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and directed.
M&L Capacitor Starting 80 mfd – 120 mfd suitable for old ones AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and directed.
M&L Fan Motor Capacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0/3.0 TR capacity including taking our unserviceable Fan motor capacitor from AC complete all as specified and directed.
M&L Fan Motor Blades AC (Window/Split type) 1.5/2.0/3.0 TR capacity including taking out unserviceable Blades of Fan Motor from AC complete all as specified and directed.
M&L Front Plastic Grill (as per Sample) of AC (Window type) 1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing and complete all as specified and directed.
M&L Front Plastic Grill for inner unit (as per Sample) of AC (Split type) 1.5/2.0/3.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing complete all as specified and directed.
M&L Runner for air blower motor of AC (split type) AC 1.5/2.0/3.0 TR capacity (As per sample or as per site requirement) including Runner of Air Blower Motor from AC all as per existing complete all as specified and directed.
M&L Starting Relay of AC (Window/Split Type) 1.5 TR/2.0/3.00TR Capacity including taking out unserviceable Starting Relay from AC complete all as specified and directed.
M&L Strainer with Capillary Tube of AC Window/ Split Type) 1.5 /2.0/3.0TR Capacity (including taking out unserviceable Strainer with Capillary Tube from AC complete all as specified and directed.
M&L Thermostat Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Thermostat Switch from AC complete all as specified and directed.
S&F cooling coil suitable for window type room AC 1.5/2.0 TR including taking out unserviceable cooling coil as per sample complete all as specified and directed.
S&F Condensing coil suitable for window type AC 1.5/ 2.0 ton including taking out unserviceable Condensing coil complete all as specified and directed.
S&F Condensing coil suitable for split type AC upto 3 ton capacity including taking out unserviceable Condensing coil complete all as specified and directed.
S&F cooling coil suitable for split type AC including taking out unserviceable cooling coil complete all as specified and directed.
S&F Indoor unit suitable for 1.5 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed complete all as specified and directed.
S&F outdoor unit suitable for 1.5 TR split type AC without compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F Indoor unit suitable for up to 2 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.
S&F outdoor unit suitable for up to 2 TR split type AC without compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F in replacement of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton complete all as specified and directed.
All as per item Ser No. 137.00 above but of split/ window type AC capacity 2.0 Ton.
All as per item Ser No 137.00 above but of split/ window type AC capacity 3.0 Ton.
M&L PCB with remote for window type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L PCB with remote for Split type AC 2/3(1.5x2) Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L PCB & motherboard with remote complete set for Inverter Split type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .
S&F wiring kit suitable for 1.5/2.0/3.0 ton capacity AC complete including taking out unserviceable wiring kit complete all as specified and directed.
S&F gas charging pin valve complete including taking out unserviceable pin valve complete all as specified and directed.
Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 3 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.
All as per item Ser No. 145.00 above but R- 410 for split type AC up to 3 TR capacity.
All as per item Ser No 145.00 above but R-32 Refg upto 03 Ton AC.
S&F casing of window type AC including complany fitted condensing & cooling coil complete including PCB except compressor complete all as specified and directed.
M&L split valve ¼” for split AC up to 3.0 ton capacity complete all as specified and directed.
All as per item Ser No. 149.00 above but 1/2".
S&F in replacement compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement compressor shut off valve 5/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
All as per item Ser No. 153.00 above but size 1/2".
All as per item Ser No. 153.00 above but size 3/8".
All as per item Ser No. 153.00 above but size 5/8".
S&F in replacement PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F digital 3 level % indicator display in digits to detect & display the water level ultrasonic type in an underground /overhead tank complete all as specified and directed. Note : Make shall be got approved by GE.
S&F in repair street light dual automation system (SLDAS) to switches ON the street light on sun set when the light level dips to 40 Lux and switches Off the same on day break when light level reaches 80 Lux complete all as specified and directed.
Taking proper shutdown & Isolate the HT electric supply and taking out the trolley of VCB HT 11KV 630 Amps and servicing of all minor/major parts of the VCB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber, spout, gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire trolley, inserting the trolley, testing the complete HT electric supply and puting on supply on load complete all as specified and directed. Note:- (i) All cleaning /testing equipment/material shall be provided by the contractor and rate for the same are deemed to be included in quoted rates. (ii) The complete test report shall be submitted by the contractor to GE(I)/Engineer-in-Charge.
Taking shut down from main substation and drain out the transformer oil and to be collected in barrel by opening the transformer cover of capacity 1250 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking the any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required inculding providing & fixing monoplast putty at HT/LT cable connection of transformer complete for entire satisfaction of Engineer- in-charge.
Dehydration and filtration of transformer oil with proper dehydration machine to achieve dielectric strength between 45 to 60 KV including testing/recording of dielectric strength result before and after of dehydration complete all as specified and directed. Note:- Test report shall be submitted by the contractor to the Engineer-in-Charge.
Supply and topping up transformer oil having dielectric strength not less than 45 KV - 60 KV complete all as specified and directed.
Taking shut down from main substation and M&L for painting to Transformer 1250 KVA with spray gun with two coats of synthetic enamel heat resistant grey paint over a coat of red oxide primer including preparation of old painted surfaces/removing old faded/rust/ cemented material of surface of transformer including base frame, connected LT panels, duct covers of including writing MES/SM No of existing size/surface complete all as specified and directed.
S&F ACP retro sign board of size 1.5 x 1.1 Mtr using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the HT/LT subtation Details, and Single line Schematic diagram of substation. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on Wall including fixing of fastners , nuts, bolts, washer etc complete all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
Supply and Fix in replacement of Dehydrating breather assembly complete with silica gel grains in the breather assembly suitable for transformers 1250 KVA complete as per matching to existing complete all as specified and directed.
Sumit Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .