Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC KUMARDIHI PANDEESHWAR BARDDHAMAN BARDDHAMAN 713363 WEST BENGAL INDIA | BARDDHAMAN | BARDDHAMAN | WEST BENGAL | 713363 | L1 | Accepted-AOC TC recommendation | |
| 2 | L2₹16.0 L+₹49,536.34 (3.19%)Rejected-Finance KUMARDIHI PANDERSWAR BARDHAMAN BARDHAMAN WEST BENGAL 713363 | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713363 | L2 | Rejected-Finance TC recommendation |
Tender Value
₹15.5 L
EMD Value
₹19,400
Closing Date
20 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
General Manager Bankola Area
Office of The General Manager Bankola Area, PIN-713363
Installation of Power setup behind load centre in Panel P3, P4, P5, P6 T1 behind load centre of SHCM package in RVI seam of CM Project at Nakrakonda Kumardihi B Colliery under Bankola Area.
2023_ECL_288205_1
ECL/GM/BA/E TENDER/23-24/EnM/70 Dt. 05.09.2023
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Nakrakonda Kumardihi B Colliery
Please refer to NIT document
4 documents required · 4 mandatory
₹19,400
30 Dec 2023
6 Sept 2023
22 Sept 2023
6 Sept 2023
20 Sept 2023
6 Sept 2023
6 Sept 2023 - 11 Sept 2023
Amount
Item Description/ Heading
Manual Transportation from CM store to Incline Mouth, unreeling, transportation to u/g substation, laying and hanging 150 sq.mm. 500m PVCDWA cable upto load centre.(in panel 4 and Panel 5)
Dismantling of Existing installed PVCDWA 150sqmm, appx. Length 1000mtr. Power cable laid from substation no.1 to Panel.No.T2 upto load centre of RVI seam for marching of load centre and hanging the same.
Manual transportation of Existing installed PVCDWA 150sqmm, appx. Length 900mtr. Power cable laid from "substation no.1 to Panel.No.T2" upto load centre to "Panel no.3" of RVI seam for marching of load centre to Entry of Panel 3 and hanging the same.
Handling of Existing installed and hanging on side/roof support PVCDWA 150sqmm, appx. Length 900mtr. as per Panel development process of panel no.3 from (-7L/-3D to -7L/-16D) behind load centre.
Rerouting of Existing installed PVCDWA 150sqmm, appx. Length 900mtr. Power cable laid from substation no.1 to Panel.No.P3 (-7L/-16D)upto load centre to Entry of Panel no.4 of RVI seam for marching of load centre to Entry of Panel 4 and hanging the same.
Handling of Existing installed and hanging on side/roof support PVCDWA 150sqmm, appx. Length 500mtr. as per Panel development process of panel no.3 from (-3L/-3D to -3L/-12D) behind load centre.
Manual transportation of PVCDWA 150sqmm, appx. Length 500mtr. Power cable stacked at substation no.1 to -3L/-12D in panel no.4 for adding the same behind load centre.
Handling of additional installed and hanging on side/roof support PVCDWA 150sqmm, appx. Length 500mtr. as per Panel development process of panel no.3 from (-3L/-12D to -3L/-20D) behind load centre.
Rerouting of Existing installed PVCDWA 150sqmm, appx. Length 500mtr. Power cable laid from "substation no.1 to Panel.No.P4(-3L/-12D)" upto load centre to "+2L/-3D of Panel no.T1" of RVI seam for marching of load centre to Entry of Panel 5(to develop panel for belt installation) and hanging the same.
Rerouting back Existing installed PVCDWA 150sqmm, appx. Length 500mtr. Power cable laid from "substation no.1 to +2L/-3D of Panel no.T1" upto load centre to "-3L/-13D of Panel no.P4" of RVI seam for further development of Panel 4 and hanging the same.
Rerouting of Existing installed PVCDWA 150sqmm, appx. Length 1100mtr. Power cable laid from "substation no.1 to Panel.No.P4(-3L/-20D)" upto load centre to "+4L/-5D of Panel no.P5" of RVI seam for marching of load centre to Entry of Panel 5(for panel development) and hanging the same.
Handling of Existing installed and hanging on side/roof support PVCDWA 150sqmm, appx. Length 900mtr. as per Panel development process of panel no.5 from (+4L/-3D to +4L/-23D) behind load centre.
Manual Transportation from CM store to Incline Mouth, unreeling, transportation to u/g substation, laying and hanging 150 sq.mm. 250m PVCDWA cable upto load centre.(in Panel.no.6)
Rerouting of Existing installed PVCDWA 150sqmm, appx. Length 1100mtr. Power cable laid from "substation no.1 to Panel.No.P5(+4L/-23D)" upto load centre to "+8L/-4D of Panel no.P6" of RVI seam for marching of load centre to Entry of Panel 6(for panel development) and hanging the same.
Addition of 250m cable and Handling of Existing installed and hanging on side/roof support PVCDWA 150sqmm, appx. Length 1100mtr. as per Panel development process of panel no.6 from (+8L/-3D to +8L/-25D) behind load centre.
6 times shifting of 3.3kV FLP VCB installed in RVI seam as controlling of load centre (as per load centre shifting)
Total impact of GST for the purpose of CTC
MUKHERJEE ENTERPRISE
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .