Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAdmitted-Finance | ₹2.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.2 Cr+₹6.0 L (2.75%)Admitted-Finance | ₹2.2 Cr+₹6.0 L (2.75%) | L2 | Admitted-Finance |
| 3 | L3₹2.4 Cr+₹19.4 L (8.90%)Admitted-Finance | ₹2.4 Cr+₹19.4 L (8.90%) | L3 | Admitted-Finance |
| 4 | L4₹2.6 Cr+₹43.8 L (20.1%)Admitted-Finance L8 LAXMI INDUSTRIAL ESTATE NEW LINK ROAD ANDHERI WEST MUMBAI MUMBAI MAHARASHTRA 400053 | MUMBAI SUBURBAN | MAHARASHTRA | 400053 | ₹2.6 Cr+₹43.8 L (20.1%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical L 4 235 COMPETENT MEDICAL SYSTEM INDIA PRIVATE LIMITED VINAY KHAND GOMTI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | UTTAR PRADESH | 226010 | - | - | Rejected-Technical Technically Disqualified |
| Sl No | Description | Qty | Unit | ASB System L1 | SHIV SHAKTI GASES L3 | gmb biomed llp L2 | Hansraj Nayyar Medical India Pvt. Ltd. L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | CIVIL WORKS:
Providing and Fixing Ceiling Paneling System (SS) with anti bacterial paint
The prefabricated ceiling plates /cassettes should be made up of SS 304 panels with sheet thickness of at least 0.8 mm sandwich (both side 0.8mm sheet) panel of PUF with minimum density 40kg/m3 with matte finish and should be coated with antibacterial paint. It should be from the same manufacturer of wall panel. Total thickness should be 30-40mm.
Support elements: Suspension bracket with tension spring/ threaded rod
Material: High quality galvanized or powder coated steel.
Room lighting, air supply inlet, ceiling service units, return air outlets, etc should be integrated with ceiling system.
The individual panels except those at the edges should be removable individually.
Third party test certificate for SS Panels from material testing lab. (Govt. authorized) - to be provided at the time of pre dispatch inspection/supply.
Colour should be uniform pleasant and matching with ambience and as approved by Engineer In-charge.
Anti bacterial paint of reputed make should be coated on the ceiling panels. Test report of anti bacterial paint should be submitted. Bidder should maintain anti-bacterial paint during warranty and CMC period | 250 | Sqm | 6,500 ₹16,25,000 | 6,100 ₹15,25,000 | 10,000 ₹25,00,000 | 4,720 ₹11,80,000 Lowest |
| 2.00 | Providing and fixing antimicrobial cladding with Silver Ion technology of minimum 2.5 mm thickness for walls, ceilings and other surfaces by preparing the surfaces as per manufacturer specifications, fixing the cladding with silicon 789 of Dow Corning and VHB 3M silicon tape & Arobond or equivalent approved adhesive, the antimicrobial cladding material shall inhibits growth of wide range of microbes including MRSA , E Coil, moulds, fungi etc, should be water resistant , high fire rated , high compact strength, work including PVC welding rod of approved quality & matching colour, approved glue/bonding agent, etc complete, including making cut out for electrical fittings/fixtures, molding of PVC panel, cutting, jointing, grooving etc. complete. Guarantee: 10 years for sticking / pilling off the PVC sheets & antimicrobial property.
Antimicrobial cladding on ceiling shall be white. The Antimicrobial Silver Ion technology should be present through the thicknes of the sheet. Weight of antimicrobial cladding shall be approx. 3.5kg per m2
Make: BIOCLAD, PALCLAD or equivalent approved by Engineer-in-charge. | 525 | Sqm | 7,200 ₹37,80,000 | 6,100 ₹32,02,500 | 8,500 ₹44,62,500 | 5,192 ₹27,25,800 Lowest |
| 3.00 | Extra for digital printing on Anitimicrobial Cladding detailed in Item No- 1 | 40 | Sqm | 7,200 ₹2,88,000 | 3,000 ₹1,20,000 | 9,000 ₹3,60,000 | 2,348.2 ₹93,928 Lowest |
| 4.00 | Providing and fixing Permanently Static Dissipative pressed homogeneous vinyl flooring (EN 649) with self leveling compound ,anti static, wear layer thickness is 2mm (EN428), PVC Vinyl flooring having Carbon backing a with total weight 3060 g/m2 (EN 430), XR PUR (polyurethane reinforced), Abrasion group P:≤4,0mm, residual indentation approx. 0,02 mm, castor wheel test qualified, dimensional stability ≤0.40%, good resistance of scratch, slip, chemical and fire, doesn’t favor in growth of fungi. Electric resistance is as per EN 1081 and ESD approved. Restorable properties. Available in rolls. 100% recyclable. Low VOC emission after 28days of installation (lower than ≤100μg/m3). Non Directional in Design.
Floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided.
Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour The sheets should be highly durable with resistance to shock and indentation. It should be scratchproof also. The conductive material should be uniformly impregnated as grains.
It should be inert to body fluids, chemicals and disinfectants.Also, it Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV Flooring should be done by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10^4 to 5x10^6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx.25mm and sealed perfectly and uniformly. Self leveling compounds of appropriate thickness for leveling of concrete/tile surface should be used (No Extra Payment for Self -leveling compound to be done seperately). The conductive copper grid laid underneath the PVC sheet should be supported by liquid epoxy compounds allowed to set as a uniform and level surface. The copper strips to be made visible by grinding and no copper strip should project more than 0.5mm above level surface to avoid damage to the PVC sheet. One earthing lead should be brought out from every 150sq.ft area and attaching it to the main earthing strip/ground.
Copper grounding strips (0.05 mm thick, 50 mm width) should be laid flat on the floor in the conductive adhesive and connected to copper strip of grounding. The connection from copper grid should be brought out uniformly at places to form equipotential grid. Flooring should be mechanically shock proof, scratch proof, flame retardant and anti microbial
Corners should be uniformly curved Final surface should be non corrosive to biological fluids and detergents.
Colour should be uniform pleasant and matching with ambience and as approved by Engineer In-charge
Suitable self-leveling should be done before PVC flooring to avoid undulation within the OT. | 384 | Sqm | 3,000 ₹11,52,000 Lowest | 4,000 ₹15,36,000 | 3,675 ₹14,11,200 | 3,599 ₹13,82,016 |
| 5.00Providing and Fixing Hermetically Sealed single sliding door of 2.4 (H)X 1.5 m(W). The controller should be capable of being operated by elbow switches/foot switches as well as touch less sensor. The track should be of stainless steel/Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement. The door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the stainless steel/Aluminium track to enable smooth and noiseless movement. Opening and closing of the door should be microprocessor controlled electromechanical movement. The door material should be of SMS/ HPL Color should match the interior and care should be taken to make the leaf strong and light weight. One should be able to open and close the door effortlessly incase of failure of automatic mechanism.Door opening handle should be strong and sturdy. Material should be of SS (matte finish). Should be provided with high quality cylindrical/ ESPg lock. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential). Air tightness 99.99% at a pressure of minimum 75Pa.The finished floor on either side of the door should be perfectly level (maximum permissible difference +1mm). The overall thickness of the finished door should be 30-60mm. The inner part of the door should be filled with CFC free polyurethane foam thickness of 48mm or nearby. (Sealed airtight to prevent further ingress of any microbial organism). The door and controls should comply with IEE regulation. All motors used should be DC brushless/PMDC motors with essential isolation from mains. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed. Door movement should have minimum noise. The starting time after receiving the signal should be adjustable between 0.5 to 20 seconds.The door controller should be CE marked/BIS certified/IEC 60601 certified.Test certificate for hermetically sealed door frame (factory test certificate) should be enclosed with the pre dispatch documents. | |||||||
| 5.10 | A) HERMETICALLY SEALED DOORS Size 2.4mx1.5 m (As per AERB Norms) | 4 | Nos | 6,00,000 ₹24,00,000 | 3,45,937.5 ₹13,83,750 Lowest | 3,50,000 ₹14,00,000 | 3,83,500 ₹15,34,000 |
| 5.20 | B) HERMETICALLY SEALED DOORS Size 2.4mx1.8 m (As per AERB Norms) | 2 | Nos | 6,35,000 ₹12,70,000 | 4,00,000 ₹8,00,000 | 3,50,000 ₹7,00,000 Lowest | 4,13,000 ₹8,26,000 |
| 6.00 | Providing and fixing in position 38 mm thick flush door including cladding on all sides with anitmicrobial PVC sheet of min.2.5 mm thick, heavy duty gaskets for air tightness, two hours fire retardant, vision panel of approx 300mm X 450mm using 8 mm thick plain glass with one inch beveling on both side & teak wood lipping patti all around including approved colour 18/19 mm thick granite frame with moulding/chamfering of all exposed edges, heavy duty lock, SS handles (600 mm), SS tower bolt (400 mm), floor spring, etc fittings & fixtures of dorma, hafle or equivalent approved make, adequate size wooden cleat for pivots, etc complete as per the instruction of EIC. (size of door is 1800mm X 2400mm - height is from FFL) | 2 | Nos | 70,000 ₹1,40,000 Lowest | 2,00,000 ₹4,00,000 | 1,50,000 ₹3,00,000 | 1,47,500 ₹2,95,000 |
| 7.00 | Providing & fixing riser return air grills to A C duct, it shall be made up of stainless steel 304 grade and shall be as per the size, shape & instruction of EIC (make: Airtech or equivalent) | 24 | Nos | 6,500 ₹1,56,000 | 5,000 ₹1,20,000 | 5,500 ₹1,32,000 | 2,950 ₹70,800 Lowest |
| 8.00 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 350 | Sqm | 269 ₹94,150 | 100 ₹35,000 Lowest | 185 ₹64,750 | 177 ₹61,950 |
Tender Value
Refer Docs
EMD Value
₹5.3 L
Closing Date
31 Mar 2025, 3:00 pmClosed
Director MPMMCC
MPMMCC, BHU Campus, Sunderbagiya, Varanasi 221005
Interior work for Operation Theatres 4 Nos. Major and 2 Nos. Minor OTs at HBCH and RC Muzaffarpur Bihar 842004
2025_TMC_851492_1
HBCHRC/INTERIOR/OT/25/NIT/09
Open Tender
Civil Works - Others
Item Rate
180 days
Muzaffarpur
As per Tender Document
2 documents required · 2 mandatory
₹0
₹5.3 L
Yes
HBCHRC Muzaffarpur
10 May 2025
3 Mar 2025
1 Apr 2025
3 Mar 2025
31 Mar 2025
16 Mar 2025
8 Mar 2025 - 13 Mar 2025
15 Mar 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | CIVIL WORKS:
Providing and Fixing Ceiling Paneling System (SS) with anti bacterial paint
The prefabricated ceiling plates /cassettes should be made up of SS 304 panels with sheet thickness of at least 0.8 mm sandwich (both side 0.8mm sheet) panel of PUF with minimum density 40kg/m3 with matte finish and should be coated with antibacterial paint. It should be from the same manufacturer of wall panel. Total thickness should be 30-40mm.
Support elements: Suspension bracket with tension spring/ threaded rod
Material: High quality galvanized or powder coated steel.
Room lighting, air supply inlet, ceiling service units, return air outlets, etc should be integrated with ceiling system.
The individual panels except those at the edges should be removable individually.
Third party test certificate for SS Panels from material testing lab. (Govt. authorized) - to be provided at the time of pre dispatch inspection/supply.
Colour should be uniform pleasant and matching with ambience and as approved by Engineer In-charge.
Anti bacterial paint of reputed make should be coated on the ceiling panels. Test report of anti bacterial paint should be submitted. Bidder should maintain anti-bacterial paint during warranty and CMC period | 250 | Sqm | - | - |
| 2 | Providing and fixing antimicrobial cladding with Silver Ion technology of minimum 2.5 mm thickness for walls, ceilings and other surfaces by preparing the surfaces as per manufacturer specifications, fixing the cladding with silicon 789 of Dow Corning and VHB 3M silicon tape & Arobond or equivalent approved adhesive, the antimicrobial cladding material shall inhibits growth of wide range of microbes including MRSA , E Coil, moulds, fungi etc, should be water resistant , high fire rated , high compact strength, work including PVC welding rod of approved quality & matching colour, approved glue/bonding agent, etc complete, including making cut out for electrical fittings/fixtures, molding of PVC panel, cutting, jointing, grooving etc. complete. Guarantee: 10 years for sticking / pilling off the PVC sheets & antimicrobial property.
Antimicrobial cladding on ceiling shall be white. The Antimicrobial Silver Ion technology should be present through the thicknes of the sheet. Weight of antimicrobial cladding shall be approx. 3.5kg per m2
Make: BIOCLAD, PALCLAD or equivalent approved by Engineer-in-charge. | 525 | Sqm | - | - |
| 3 | Extra for digital printing on Anitimicrobial Cladding detailed in Item No- 1 | 40 | Sqm | - | - |
| 4 | Providing and fixing Permanently Static Dissipative pressed homogeneous vinyl flooring (EN 649) with self leveling compound ,anti static, wear layer thickness is 2mm (EN428), PVC Vinyl flooring having Carbon backing a with total weight 3060 g/m2 (EN 430), XR PUR (polyurethane reinforced), Abrasion group P:≤4,0mm, residual indentation approx. 0,02 mm, castor wheel test qualified, dimensional stability ≤0.40%, good resistance of scratch, slip, chemical and fire, doesn’t favor in growth of fungi. Electric resistance is as per EN 1081 and ESD approved. Restorable properties. Available in rolls. 100% recyclable. Low VOC emission after 28days of installation (lower than ≤100μg/m3). Non Directional in Design.
Floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided.
Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour The sheets should be highly durable with resistance to shock and indentation. It should be scratchproof also. The conductive material should be uniformly impregnated as grains.
It should be inert to body fluids, chemicals and disinfectants.Also, it Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV Flooring should be done by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10^4 to 5x10^6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx.25mm and sealed perfectly and uniformly. Self leveling compounds of appropriate thickness for leveling of concrete/tile surface should be used (No Extra Payment for Self -leveling compound to be done seperately). The conductive copper grid laid underneath the PVC sheet should be supported by liquid epoxy compounds allowed to set as a uniform and level surface. The copper strips to be made visible by grinding and no copper strip should project more than 0.5mm above level surface to avoid damage to the PVC sheet. One earthing lead should be brought out from every 150sq.ft area and attaching it to the main earthing strip/ground.
Copper grounding strips (0.05 mm thick, 50 mm width) should be laid flat on the floor in the conductive adhesive and connected to copper strip of grounding. The connection from copper grid should be brought out uniformly at places to form equipotential grid. Flooring should be mechanically shock proof, scratch proof, flame retardant and anti microbial
Corners should be uniformly curved Final surface should be non corrosive to biological fluids and detergents.
Colour should be uniform pleasant and matching with ambience and as approved by Engineer In-charge
Suitable self-leveling should be done before PVC flooring to avoid undulation within the OT. | 384 | Sqm | - | - |
| 5Providing and Fixing Hermetically Sealed single sliding door of 2.4 (H)X 1.5 m(W). The controller should be capable of being operated by elbow switches/foot switches as well as touch less sensor. The track should be of stainless steel/Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement. The door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the stainless steel/Aluminium track to enable smooth and noiseless movement. Opening and closing of the door should be microprocessor controlled electromechanical movement. The door material should be of SMS/ HPL Color should match the interior and care should be taken to make the leaf strong and light weight. One should be able to open and close the door effortlessly incase of failure of automatic mechanism.Door opening handle should be strong and sturdy. Material should be of SS (matte finish). Should be provided with high quality cylindrical/ ESPg lock. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential). Air tightness 99.99% at a pressure of minimum 75Pa.The finished floor on either side of the door should be perfectly level (maximum permissible difference +1mm). The overall thickness of the finished door should be 30-60mm. The inner part of the door should be filled with CFC free polyurethane foam thickness of 48mm or nearby. (Sealed airtight to prevent further ingress of any microbial organism). The door and controls should comply with IEE regulation. All motors used should be DC brushless/PMDC motors with essential isolation from mains. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed. Door movement should have minimum noise. The starting time after receiving the signal should be adjustable between 0.5 to 20 seconds.The door controller should be CE marked/BIS certified/IEC 60601 certified.Test certificate for hermetically sealed door frame (factory test certificate) should be enclosed with the pre dispatch documents. | |||||
| 5.1 | A) HERMETICALLY SEALED DOORS Size 2.4mx1.5 m (As per AERB Norms) | 4 | Nos | - | - |
| 5.2 | B) HERMETICALLY SEALED DOORS Size 2.4mx1.8 m (As per AERB Norms) | 2 | Nos | - | - |
| 6 | Providing and fixing in position 38 mm thick flush door including cladding on all sides with anitmicrobial PVC sheet of min.2.5 mm thick, heavy duty gaskets for air tightness, two hours fire retardant, vision panel of approx 300mm X 450mm using 8 mm thick plain glass with one inch beveling on both side & teak wood lipping patti all around including approved colour 18/19 mm thick granite frame with moulding/chamfering of all exposed edges, heavy duty lock, SS handles (600 mm), SS tower bolt (400 mm), floor spring, etc fittings & fixtures of dorma, hafle or equivalent approved make, adequate size wooden cleat for pivots, etc complete as per the instruction of EIC. (size of door is 1800mm X 2400mm - height is from FFL) | 2 | Nos | - | - |
| 7 | Providing & fixing riser return air grills to A C duct, it shall be made up of stainless steel 304 grade and shall be as per the size, shape & instruction of EIC (make: Airtech or equivalent) | 24 | Nos | - | - |
| 8 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 350 | Sqm | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.pdf
Tender Documents • 2.28 MB
Tenderdocument_2.pdf
Tender Documents • 1.75 MB
Tenderdocument_3.pdf
Tender Documents • 0.37 MB
BOQ.xls
BOQ • 0.35 MB
Tenderdocument_4.pdf
Tender Documents • 4.15 MB
Tenderdocument_5.pdf
Tender Documents • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .