RequiredExperience with Government
RequiredAnnual Turnover
RequiredOEM Authorization Certificate Bid to RA enabled No FRP Urinal Cabin ( 20 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Cofiguration Urinals without washbasin Urinals without washbasin Design & Function of the urinal Half stall urinal - supported by flange. Half stall urinal - supported by flange. Mode of Supply Assembled Ready To Use Assembled Ready To Use Number of urinal Cabins 1 no. 1 no.
Required2 nos.
Required3 nos.
Required4 nos.
Required5 nos. Number of Urinals 1 no. 1 no.
Required2 nos. 1/10 Water facility By mean of overhead tank(Capacity 200Ltrs) By mean of overhead tank(Capacity 200Ltrs) Sewage facility Sludge tank(Capacity 200 Ltrs) with 75mm outlet facility through butterfly valve and hosepipe(for 1-seater and 2-seater) Sludge tank(Capacity 200 Ltrs) with 75mm outlet facility through butterfly valve and hosepipe(for 1-seater and 2-seater) Ventilation One No. One No.
RequiredTwo No.
RequiredFull size ventilation above door plus half size ventilation on other side for cross ventilation
RequiredAll 4 - sides
RequiredNo ventilation
RequiredExhaust fan facility Lifting hook No lifting hook One number heavy lifting hook provided
RequiredTwo number heavy lifting hook provided
RequiredFour number heavy lifting hook provided
RequiredNo lifting hook Roof shape Dome type * Projection of Roof No projection 50mm projection on all the four sides
Required100mm projection from front and 50mm projection on other sides
Required50mm projection from front and 25mm projection on other sides
RequiredNo projection Installation and commissioning To be done by Consignee himself To be done by seller
RequiredTo be done by Consignee himself Plumbing and Sanitary fitting connection To be done by Consignee himself To be done by seller
RequiredTo be done by Consignee himself Electrical connection To be done by Consignee himself To be done by seller
RequiredTo be done by Consignee himself Waste extraction fittings To be done by Consignee himself To be done by seller
RequiredTo be done by Consignee himself Civil foundation Required - To be done by consignee himself No foundation required
RequiredRequired - To be done by seller
RequiredRequired - To be done by consignee himself Transpotations/Freight Offer Prices are on Free * 2/10 charges Delivery at Consignee site basis. Shape of cabin Square * Materials used to produce urinals for Men's FRP Ceramic
RequiredSteel
RequiredFRP Materials used to produce urinals for Women's FRP integrated with floor FRP integrated with floor Number of cabins having urinals without washbasin N.A 1 no.
Required2 no.
Required3 no.
Required4 no.
Required5 no.
RequiredN.A Number of urinal cabins having one number inside washbasin N.A 1 no.
Required2 no.
Required3 no.
Required4 no.
Required5 no.
RequiredN.A Number of urinal cabins having two numbers inside washbasin N.A 1 no.
Required2 no.
Required3 no.
Required4 no.
Required5 no.
RequiredN.A Number of urinal cabins having one number outside washbasin N.A 1 no.
Required2 no.
Required3 no.
Required4 no.
Required5 no.
RequiredN.A Number of urinal cabins having two numbers outside washbasin N.A 1 no.
Required2 no.
Required3 no.
Required4 no.
Required5 no.
RequiredN.A Water spreader facility Water spreader available ( For Gent's urinal ) Water spreader available ( For Gent's urinal )
RequiredOne push cock water tap available ( For Ladie's urinal ) Partition for Gent's urinal No Yes
RequiredNo Type of mounting Floor mount - Supported and fixed in floor. Floor mount - Supported and fixed in floor.
RequiredWall mount - Fixed in a wall Unit type Portable Portable Sensor urinal - Automatic water flushing urinal No * FRAME MATERIAL Bottom frame material 35mm X 35mm X 5mm(thick) MS angle for 1 no. urinal 35mm X 35mm X 5mm(thick) MS angle for 1 no. urinal
Required75mm X 37.5mm C-channel MS(for 2 nos. urinal & 3 nos. urinal)
Required35mm X 35mm X 5mm(thick) SS 3/10 angle for 1 no. urinal
Required75mm X 37.5mm C- channel SS(for 2 nos. urinal & 3 nos. urinal)
Required25mm X 25mm X 16 gauge MS Sq. pipe and MS angle
RequiredNo bottom frame structure Bottom frame support material 25mm X 25mm X 3mm(thick) MS angle (for 1 no. urinal
Required2 nos. urinal & 3 nos. urinal) 25mm X 25mm X 3mm(thick) MS angle (for 1 no. urinal
Required2 nos. urinal & 3 nos. urinal)
Required25mm X 25mm X 3mm(thick) SS angle
RequiredNo support structure Side panel frame material 25 mm x 25 mm x 2 mm (thick) MS pipe as per IS 4923/latest 35mm X 35mm X 5mm(thick) MS angle
Required35mm X 35mm X 5mm(thick) SS angle
Required25 mm x 25 mm x 2 mm (thick) MS pipe as per IS 4923/latest
Required38 mm x 38 mm x 2 mm (thick) MS pipe as per IS 4923/latest
RequiredNo side frame structure Top(roof) frame material 25 mm x 25 mm x 2 mm (thick) MS pipe as per IS 4923/latest 35mm X 35mm X 5mm(thick) MS angle
Required35mm X 35mm X 5mm(thick) SS angle
Required25 mm x 25 mm x 2 mm (thick) MS pipe as per IS 4923/latest
Required38 mm x 38 mm x 2 mm (thick) MS pipe as per IS 4923/latest
RequiredNo roof frame structure Top(roof) support frame structure 25 mm x 25 mm x 2 mm (thick) MS pipe as per IS 4923/latest 25mm X 25mm X 3mm(thick) MS angle
Required25mm X 25mm X 3mm(thick) SS angle
Required25 mm x 25 mm x 2 mm (thick) MS pipe as per IS 4923/latest
Required38 mm x 38 mm x 2 mm (thick) MS pipe as per IS 4923/latest
RequiredNo support structure Partition frame material No partition frame structure 35mm X 35mm X 5mm(thick) MS angle
Required35mm X 35mm X 5mm(thick) SS angle
Required25 mm x 25 mm x 2 mm (thick) MS pipe as per IS 4923/latest
Required38 4/10 mm x 38 mm x 2 mm (thick) MS pipe as per IS 4923/latest
RequiredNo partition frame structure Ventilation frame material 25mm X 25mm X 3mm(thick) flat MS 25mm X 25mm X 3mm(thick) flat MS
Required25mm X 25mm X 3mm(thick) flat SS
Required25 mm x 25 mm x 2 mm (thick) MS Flat
RequiredNo ventilation frame material Door frame material No door frame material 50mm X 25mm of 14-16gauge rectangular MS hollow pipe
Required50mm X 25mm of 14-16gauge rectangular SS hollow pipe
Required35 mm x 35 mm x 5 mm (thick) MS ANGLE
RequiredNo door frame material Support material for Door panel fixing No support material Aluminium U-channel of 18gauge
RequiredSS U- channel of 18gauge
RequiredNo support material Door hinges(two numbers) 75mm size with 1.2-1.5mm thickness MS 75mm size with 1.2-1.5mm thickness MS
Required75mm size with 0.6-0.8mm thickness SS
Required75mm size with 1.2-1.5mm thickness Chrome plated Tank holder frame material No Support 25mm X 3mm(thick) MS flat
Required25mm X 3mm(thick) SS flat
Required1125mm X 820mm outer ring(tubular structure)-MS
RequiredNo Support Unit understructure Supported by 4-legs of size 35mm X 35mm X 5mm MS angle with corner support of 25mm x 25mm X 3mm MS angle for 1 no. urinal Supported by 4-legs of size 35mm X 35mm X 5mm MS angle with corner support of 25mm x 25mm X 3mm MS angle for 1 no. urinal
RequiredSupported by 4-legs of size 35mm X 35mm X 5mm SS angle with corner support of 25mm x 25mm X 3mm SS angle for 1 no. urinal
RequiredSupported by 5/10 4-legs of size 75mm X 37mm C-channel MS angle
RequiredSupported by 4-legs of size 75mm X 37mm C-channel SS angle
RequiredPedestal base having 890mm X 1065mm X 300mm(height) FRP molded
RequiredSupported by 4-legs of size 25 mm x 25 mm x 2 mm (thick) MS pipe with corner support of 25 mm x 25 mm x 2 mm MS pipe as per IS 4923/latest for 1 no. urinal
RequiredSupported by 4-legs of size 25 mm x 25 mm x 2 mm (thick) MS pipe with central support of 38 mm x 38 mm x 2 mm MS pipe as per IS 4923 latest for 2 nos. urinal
RequiredWithout understructure Stairs frame material No stairs 25mm x 25mm X 3mm MS angle
Required25mm x 25mm X 3mm SS angle
RequiredNo stairs Stairs material No stair material 25mm X 3mm MS flat
Required25mm X 3mm SS flat
RequiredNo stair material Door Tee material No door Tee material 40mm X 40mm x40mm X 5mm(thick) MS Tee
Required40mm X 40mm x40mm X 5mm(thick) SS Tee
RequiredNo door Tee material PANEL MATERIAL Side panel material 5mm thick ply core sandwich with 1mm thick FRP from both sides(5+1+1mm) 5mm thick ply core sandwich with 1mm thick FRP from both sides(5+1+1mm)
RequiredSingle layer 3mm thick FRP Top(Roof) panel material 5mm thick ply core sandwich with 1mm thick FRP from both sides(5+1+1mm) 5mm thick ply core sandwich with 1mm thick FRP from both sides(5+1+1mm)
RequiredSingle layer 3mm thick FRP
Required4mm poly carbonate sheet fitted on top Door panel material 5mm thick ply core sandwich with 1mm thick FRP from both 5mm thick ply core sandwich with 1mm thick FRP from both 6/10 sides(5+1+1mm) sides(5+1+1mm)
RequiredSingle layer 3mm thick FRP Partition panel material No partition 5mm thick ply core sandwich with 1mm thick FRP from both sides(5+1+1mm)
RequiredSingle layer 3mm thick FRP
RequiredBaked enamel
RequiredPlastic laminate
RequiredSolid phenolic
RequiredSolid plastic
RequiredStainless steel
RequiredNo partition Floor material 5mm thick FRP material 5mm thick FRP material
Required2-3mm thick SS material
RequiredFitted with plastic light weight LLDPE roto molded
RequiredAnti skid tile finish floor inside toilet
RequiredThe double wall constructed ready-made base shall be made out with Plastics material by roto-molded process - PUF to be filled in cavity between two walls for extra load bearing - single piece molded with required outlets - special handle to be provided on two side of toilet block for easily shifting the whole Block
Required1.6 mm thick SS 304
Required2 mm thick SS 304 DIMENSION Cabin size for Gent's urinal (LXWXH) ± 25mm 840 mm X 890 mm X 1980 mm (for 1 no. urinal) 840 mm X 890 mm X 1980 mm (for 1 no. urinal)
Required1700 mm X 1220 mm X 1980 mm (for 2 nos. urinal)
Required2055 mm X 1220 mm X 1980 mm (for 3 nos. urinal)
Required2745 mm X 1220 mm X 1980 mm (for 4 nos. urinal)
Required3430 mm X 1220 mm X 1980 mm (for 5 nos. urinal)
RequiredNo urinals for Gents Door size(WxH) ± 20mm 585 mm x 1830 mm 585 mm x 1830 mm
Required655 mm X 1790 mm (Steel sheet thickness - 0.6mm 275MPA) 7/10 Ventilation size (WXH) ± 10mm 838 mm X 150 mm(above door) plus 838mm X 75mm(opposite side) 838 mm X 150 mm(above door) plus 838mm X 75mm(opposite side)
Required650 mm X 40 mm
RequiredNo ventilation Partition height for cabin ± 20mm No partition 1830 mm
RequiredNo partition Gent's urinal pot size ± 10mm 700 mm 455 mm
Required610 mm
Required700 mm Stairs size ± 10mm No stairs 610mm X 230mm having 1-step
Required610mm X 230mm having 2-step
Required610mm X 230mm having 3-step
RequiredNo stairs Leg height ±10mm 455 mm 455 mm
RequiredNo legs Partition size for Gent's urinal 455 mm X 762 mm X 7 mm 455 mm X 762 mm X 7 mm
RequiredN.A Cabin size for Ladies urinal (LXWXH) ± 25mm 840 mm X 890 mm X 1980 mm(for 1 no. urinal) 840 mm X 890 mm X 1980 mm(for 1 no. urinal)
Required1700 mm X 890 mm X 1980 mm (for 2 nos. urinal)
Required2520 mm X 890 mm X 1980 mm (for 3 nos. urinal)
Required3360 mm X 890 mm X 1980 mm (for 4 nos. urinal)
Required4200 mm X 890 mm X 1980 mm (for 5 nos. urinal)
RequiredNo urinal for ladies MISC Door locking bolts Size 100 mm of MS Size 100 mm of MS
RequiredSize 100 mm SS Towerbolt locking Towerbolt of MS size 75mm Towerbolt of MS size 75mm
RequiredTowerbolt of SS size 75mm
RequiredTowerbolt of Aluminium size 75mm Overhead tank material No tank made of double layer HDPE sheet
Requiredmade of three layer HDPE sheet
RequiredMade of PVC
RequiredNo tank
RequiredLoft type single layer HDPE Wash basin material Made of FRP (fiber reinforced plastic) Made of FRP (fiber reinforced plastic)
RequiredMade of Ceramic
RequiredMade of SS 304
RequiredNo wash basin Dia of lifting hook NO lifting hook 20 mm
Required25 mm
Required30 8/10 mm
Required40 mm
RequiredNO lifting hook Electric provision No electric provision By mean solar energy
RequiredBY mean of battery
RequiredBy mean of connection from main line
RequiredNo electric provision Sewage provision Provided Provided
RequiredNot provided Level indicator provision N.A To be provided in every sewer/sludge tank to know the level of sludge and plan to get it evacuated
RequiredN.A Water supply connection UPVC pipe connection with all toilet interconnecting * Soap stand Plastic made Plastic made
RequiredSS 304 made
RequiredAluminium made
RequiredNo soap stand Tap No tap HDPE push cock
RequiredPVC push cock
RequiredChrome plated
RequiredPTMT tap
RequiredNo tap COLOUR & FINISH Colour of cabin As per buyer's choice * CERTIFICATION Test reports to be furnished to buyer's on demand NO YES
RequiredNO OEM of offered product is ISO 9001:2015 certified YES YES
RequiredNO WARRANTY Warranty period 1 - year 1 - year
Required2 - year
Required3 - year * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.