| 1 | L1₹1.3 CrAccepted-AOC 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC Being Lowest tender |
| 2 | L2₹1.5 Cr+₹14.8 L (10.9%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹1.5 Cr+₹14.8 L (10.9%) | L2 | Rejected-Finance Higher than lowest tender |
| 3 | L3₹1.7 Cr+₹38.1 L (28.0%)Rejected-Finance | ₹1.7 Cr+₹38.1 L (28.0%) | L3 | Rejected-Finance Higher than lowest tender |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
27 Jul 2020, 6:00 pmClosed
CE KOLKATA ZONE
HQ CHIEF ENGINEER KOLKATA ZONE, MILITARY ENGINEER SERVICES, BALLYGUNGE MAIDAN CAMP, GURUSADAY ROAD, KOLKATA-700019
PROVN OF ONE DU FOR MAJ GEN AT KOLKATA MIL STATION UNDER MAP PH-II AT KOLKATA
2020_MES_343565_1
89012/E8
Open Tender
Civil Works
Works
550 days
KOLKATA
AS PER TENDER DOCUS
8 documents required · 8 mandatory
₹1,000
GE (I) (P) KOLKATA
₹2.0 L
Yes
6 Oct 2020
9 May 2020
28 Jul 2020
9 May 2020
27 Jul 2020
6 Jul 2020
Amount
Lumpsum price worked out by the tenderer/ bidder for BUILDING WORKS as listed in Schedule ‘A’ Part-I.
Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATION as listed in Schedule ‘A’ Part-II.
Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III.
Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV.
Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/CULVERT as listed in Schedule ‘A’ Part-V.
Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI.
Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII.
Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VIII.
Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-IX.
Lumpsum price worked out by the tenderer/ bidder for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-X.
Lumpsum price worked out by the tenderer/ bidder for COMPOUND WALL/GATE as listed in Schedule ‘A’ Part-XI.
Lumpsum price worked out by the tenderer/ bidder for DEMOLITION OF BUILDING AND FENCING as listed in Schedule ‘A’ Part-XII.
Schedule ‘A’ Part-XIII (MISCELLANEOUS ITEMS) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
(INTERNAL ELECTRIFICATION) Material and labour for point wiring for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multi stranded conductor 1100 volts grade controlled by one number one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multi strand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including concealed PVC conduit complete all suitable for modular electrical accessories all as specified and as directed by the Engineer-in-Charge. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. All modular accessories to be measured and paid for separately (Light/fan/call bell) and power circuit and 5A socket circuit, DBs should be separate) (Necessary wiring for cupboard lighting should be made as directed)
All as per item No 1 here-in-before but one light point controlled two way switch with 1.5 sqmm cable complete as specified and directed
All as per item No 1 here-in-before but one call bell point controlled by one way switch with 1.5 sqmm cable complete as specified and directed. (Note: - all call bell point wiring should be terminated to servant Qtr/ kitchen/ ADC room as required by the user with necessary indication board and reset switch/push button).
All as per item No 1 here-in-before but for 5 pin 6 Amps socket outlet on the independent board with 1.5 sqmm cable complete as specified and directed.
All as per item No 1 here-in-before but for one 5 pin 6/16 Amps socket outlet on independent board with 4 Sqmm PVC insulated unsheathed copper cable multi stranded conductor 1100 volts grade and 2.5 sqmm copper conductor cable as earth continuity conductor complete as directed.
M&L for MCB SPN 40A, 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for MCB SPN 6-32Amps, 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for MCB SPN 63Amps, 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for MCB SP 6-32 Amps 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for MCB SP 40Amps, 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for MCB SP 63Amps, 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for blank plate.
M&L for MCB 4 pole 63Amps, 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for GI box, 8 module suitable for modular switch
Supply and fix sub-main wiring with PVC insulated & unsheathed (2X2.5 Sqmm and 1X2.5 Sqmm) single core multi stranded 1100 Volt grade PVC insulated & unsheathed copper conductor cable (FRLS), drawn through an including PVC concealed conduit all as specified and as directed by the Engineer-in-Charge. Note : 2 runs of 2.5 Sqmm and one run of 2.5 Sqmm earth cable and one run conduit shall measured as one length.
Supply and fix sub-main wiring with PVC insulated & unsheathed (2X4 Sqmm and 1X4 Sqmm) single core multi stranded 1100 Volt grade PVC insulated & unsheathed copper conductor cable (FRLS), drawn through an including PVC concealed conduit all as specified and as directed by the Engineer-in-Charge. Note : 2 runs of 4 Sqmm and one run of 4 Sqmm earth cable and one run conduit shall measured as one length.
Supply and fix sub-main wiring with PVC insulated & unsheathed (2X6 Sqmm and 1X6 Sqmm) single core multi stranded 1100 Volt grade PVC insulated & unsheathed copper conductor cable (FRLS), drawn through an including PVC concealed conduit all as specified and as directed by the Engineer-in-Charge. Note : 2 runs of 6 Sqmm and one run of 6 Sqmm earth cable and one run conduit shall measured as one length.
Supply and fix sub-main wiring with PVC insulated & unsheathed (2X10 Sqmm and 1X10 Sqmm) single core multi stranded 1100 Volt grade PVC insulated & unsheathed copper conductor cable (FRLS), drawn through an including PVC concealed conduit all as specified and as directed by the Engineer-in-Charge. Note : 2 runs of 10 Sqmm and one run of 10 Sqmm earth cable and one run conduit shall measured as one length (for AC plug and socket)
Supply and fixing of LED tube light fittings 16 W, 4 feet length with all necessary connection and fixing arrangements with the following specifications: - (i) System Watts/lumens: - Max 16 W/Total system lumen not less than 2240 Lm.(ii) Housing: - Extruded polycarbonate. (iii) IP rating: - IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt. (ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV. (xv) Heat sink: - As per OEM's design. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be struct structured in the same sequence.
Supply and fix surface & wall mounted LED batten 2 feet with 1x8 w indoor decorative luminaries with and including Electronic driver and 1 x8 Watt LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 8 W/Total system lumen not less than 1200 Lm.(ii) Housing: - Extruded polycarbonate. (iii) IP rating: - IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt. (ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV. (xv) Heat sink: - As per OEM's design. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structed in the same sequence
Supply and fix surface mounted LED wall bracket fittings with 6 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (Switch of this type of one lamp shall be provided beside of Bed at each bedroom which will work as night lamp) (wall brackets are for bedroom/dining/living/ office only) (i) System Watts/lumens: - Max 06 W/Total system lumen not less than 840 Lm. (ii) Housing: - Extruded olycarbonate. (iii) IP rating: - IP 20. (iv) Front/top cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt.(ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life:- Not less than 25000 hrs of operation.(xii) Optics:- Designed for optimum light distribution. (xiii) Control gear:- Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating vlotage 180-270V Ac, 50 Hz (xiv) Surage protection:- Inbuilt surage protection minimum 2KV (xv) Heat sink:- As per OEM's design Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structed in the same sequence
Supply and fix wall mounted adjustable angle LED focus/spot light 10 watt indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (for focusing on the portait/photos) (i) System Watts/lumens: - Max 10 W/Total system lumen not less than 1260 Lm.(ii) Housing: - Extruded polycarbonate. (iii) IP rating: - IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt. (ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV. (xv) Heat sink: - As per OEM's design. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structed in the same sequence.
Supply and fix surface mounted LED mirror light 10 watt indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 10 W/Total system lumen not less than 1400 Lm.(ii) Housing: - Extruded polycarbonate. (iii) IP rating: - IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt. (ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV. (xv) Heat sink: - As per OEM's design. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structed in the same sequence.
Supply and fixing of LED panel on ceiling surface mounted 2'X2' 36/40W, complete with inbuilt driver all connection and all fixing arrangements as specified below: - (i) System Watts/lumens: - Max 40W/Total system lumen not less than 5600 Lm.(ii) Housing: - Extruded polycarbonate. (iii) IP rating: - IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt. (ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV. (xv) Heat sink: - As per OEM's design. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be struct in the same sequence.
Supply and fixing of LED Surface mounted down light of 6W complete with connection and fixing arrangements. (This light is for cupboard self for warm-up/illumination and dehumidification of cupboard)
M&L for Brush less DC (BLDC) ceiling fan with the following specifications:- ((i) Motor: - Brushless DC 32 W, with operating voltage 140V-240V AC, 50 Hz. (ii) Max RPM: - 360 RPM. (iii) Sweep: - 1200mm. (iv) Colour:- White. (v) Remote control operated. (vi) 5 STAR energy saving rating
M&L for exhaust fan 250mm sweep with metalic blades flush mounting, Square type body case, operated on 230V, single phase Ac, 50 Hz complete with connection
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Meter deep below normal ground level) with top edge of plate not less than 1.5 Meter below normal ground level connected to GI wire 4mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earthwork, supplying and laying charcoal dust, common salt PCC 1:2:4 type CI chamber and MS angle iron frame 40x40x3mm RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia CI funnel and wire mesh, 20 mm dia GI pipe light graded for watering all as shown in drawing and connected to earth test point including testing complete all as specified and directed .
M&L for PVC Concealed conduit only with necessary junctionbox and accessories 20mm for TV and telephone cable with all cutting and finishing work.
S&F exhaust fan 250mm sweep, PVC, square type body case operated on AC 230V Single phase 50 Hz, 1350 RPM complete all as specified and directed..
S&F TV jack suitable for co-axial cable.
S&F Telephone jack RJ-11 for telephone and intercon connection.
S&F AC single phase 230 V KWH meter 5-30 Amps with enclusure complete.
S&F MCB producted power unit 25Amps for AC make C&S, Siemens, L&T and Legrand
S&F wall mounted fans 300mm sweep AC 230V, 50Hz with speed control complete with flexible copper conductor 23/0.076 for connecting complete
INTERNAL WATER SUPPLY S&F 15mm bore dia brass chromium plated fancy type Long body bib taps, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.( The fitting shall be continental model of Jaquar /Floral model of Cera /Essco model of Marc as approved)
S&F 15mm bore dia brass chromium plated bib taps, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.
S&F 15mm bore dia brass chromium plated two way bib taps, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. (The fitting shall be continental model of Jaquar /Floral model of Cera /Essco model of Marc as approved)
S&F 15mm bore dia brass chromium plated wall mixer screwed for iron pipe or for brass ferrule and fixed.( The fitting shall be continental model of Jaquar /Floral model of Cera /Essco model of Marc as approved)
S&F 15mm bore dia brass chromium plated basin mixer for mixing hot & cold water screwed down for iron pipe and fixed.( The fitting shall be continental model of Jaquar /Floral model of Cera /Essco model of Marc as approved)
S&F 15mm bore dia brass chromium plated fancy type angle stop valves screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.( The fitting shall be continental model of Jaquar /Floral model of Cera /Essco model of Marc as approved)
S&F Brass chromium plated shower roses 125mm size with or without swivel joints, including fixing to steel pipe or union. The fitting shall be OHS 1789 model of Jaquar /Floral model of Cera /Essco model of Marc as approved
S&F 15mm bore dia brass chromium plated concealed stop valves with long shank and cup, screwed both ends for iron pipe or for unions and fixed.
S&F 15mm bore dia brass chromium plated pillar taps with capstan heads, screwed down high pressure, screwed for iron pipe and fixed.
S&F 15mm bore CP Health faucet ABS body with wall hook and 1 metre CP PVC hose pipe. Make Jaquar/Cera/Marc.
S& F Jet spray with connector pipe fixed with EWC seat cover as specified. Make Jaquar/Cera/Marc.
M&L pre polished UV resistance coloured Machine pressed precast cement concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thick M-40 grade complete all as specified.
M&L pre polished UV resistance coloured Machine pressed precast cement concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thick M-35 grade complete all as specified.
Supply, Install, Testing and commissioning of Solar Water Heating System with heat exchanger for cold and warm regions respectively with solar flat plate collector confirming tof IS: 12933 (Part1) with amdt. No 1 and IS: 12933 (Part 2/2003 suitable for inlet water with chlorine and flourine content up to 100 ppm and supply water at the out of 100 Ltrs capacity with out electrical back up meeting specifications as under and comprising of followings:- Supply and fixing rotational moulded polyethylene water storage tank (cylindrical vertical with closed lockable top with lid and locking arrangements) hoisted and fixed in position all as specified in SSR Part-1 of capacity 100 Ltrs complete for storage of cold water feeding to solar water heater, including 3 meter staging made out of MS angel iron 50 x 50 x 6 mm all as specified and directed at site by Engr-in-Charge.
Material: 1. Solar water heating system: Comprising of solar flat plate collector, collectors stand assembly, stainless steel indulated hot water storage tank with heat exchanger and various other components. Solar flat plate collectore components shall have:- * Solar flat plate collector cover plate made of toughened glass * Sheet for absorber made of copper * Absorber made of copper sheet and copper tube. Solar Flat plate Collector: Solar flat plate collector shall confirming to IS: 12933 (Part 1) with amdt, no. 1 and IS:12933 (Part 2)/2003 and various components shall be as under:Cover plate: Cover plate shall be toughened glass and thickness of 4.0 mm (min.) conforming to section-1 of IS:12933 (Part-2)/2003. The solar transmittance of the cover plate shall be minimum 82 percent at near normal incidence. Collector Box: Collector box shall be made of Alumminium sections only. Type, grade, size, workmanship and finish of the material used shall be as per section-2 of IS: 12933 (pt2/20003). The minimum thickness of Aluminium shall be as under:- (a) Channel section for sides 1.6 mm (b) Sheet for bottom 0.7mm (c) Support for glass retaining 1.2mm (d) Sheet for entire body 1.0m
Absorber:- Absorber shall consist of riser, header, and sheet for absorber. The Diameter of header shall be 25.4+/-0.5 mm and thickness 0.71 mm. The Diameter of riser shall be 12.7+/-0.5 mm and thickness 0.56 mm and made of copper only. The distance between the risers from centre to centre shall be 120mm. Type grade, size, workmanship and finish of the material used shall be as per section-3 of IS:12933 (Part 2)/2003. Riser and header assembly designed for working pressure up to 24.5 K Pa(2.5 kg/cm2) shall be tested for leakage at a minimum hydraulic pressure of 490 K pa (5 Kg/cm2). Sheet for Absorber:- Sheet for absorber shall be made of copper only. Type, grade, size, workmanship and finis of the material used shall be as per section-3 of IS: 12933 (Pt 2)/2003. A sample piece of the absorber for having minimum area of 400 square cm. shall be heated in an oven at temperature of 175 degree C for 2 hours. After heating, the sample shall be taken out from the oven and cooled at room temperature. The cooled sample, shall be inspected visually for damages, if any. There shall not be any appearance of blistering/rupture/peeling off of the coated/painted surface and of weaking of the bonding between absorber sheet and risers/headers.
Collector box insulation:- Insulation shall be provided at back and sides. Thermal Resistance of insulation material shall be minimum 0.96m square degree C/W for back insulation and minimum 0.48 m square degree C/W for side insulation. This shall be derived after determining thermal conductivity (K) value at 100 degree C mean temperature in accordance with IS:3346. Collector box insulation shall conform to sec.4 of IS: 12933 (part-2)/2003. Gaskets and Gromments:- Gaskets and Gromments shall conform to sec.5 of IS: 12933 (part-2)/2003. Insulated hot water storage tank:- The thickness of the water storage tank shall be uniform. Material: Insulated hot water storage tank shall be non-pressure type and made of stainless steel grade (X04Cr19Ni9 or X07Cr18Ni9 of IS:1570 (part5) / 1985, TIG welded. Insulation: Solar water heating system (SWHS) up to and including 100 LPD shall be insulated with 40mm thermal grade PUF insulation of 32 Kg/meter cube or higher density. PUF insulation could be pre extruded type fitted with FRP exterior cladding or alternatively injection moilded in twin walled steel tank and PPE end cap. Other systems shall be insulated with 100 mm thick Rock wool of 48 Kg/m3 density with 22swg aluminium cladding. Systems upto 100 LPD may also alternatively be installed with 100mm thick rock wool of same specification with aluminium of GI powder coated cladding. Tank stand; tank stand assembly shall be made of MS angle of size(min) 38 x 38 x 4mm duly pre-treated and stove enamelled with black colour paint. Alternatively tubular structure with powder coating could also be provided.
Heat Exchanger:- Heat Exchanger shall be cage type and made of copper/ stainless steel tubes of grade X04Cr19Ni9 or X07Cr18Ni9 of IS:1570(Part 5)/1985. Heat exchangers shall have a minimum of 0.24 sq m heat transfer area per 100 LPD capacities. System inter connecting piping:- ISI marked GI pipes, medium class of IS:1239 duly insulated with 50mm thick rock wool of 48 Kg/m3 density and 26 swg AI cladding. EPDM hose pipes can also be used for systems up to and including 500 LPD. Collector stand:- Collector stand assembly shall be made of MS angle of size 38 X 38 X 4 mm duly pre -treated and stove enamelled with black colour paint. Alternatively tubular structure with powder coating could also be provided. Make up water tank:- The capacity of make up tank shall be up to 250 LPD. (Considered separately). Temprature Gauge:- Dial type, duly calibrated and suitable for temperature range from 0 degree C to 120 degree C and shall be provided. Valves:- 3 valves, one for inlet, outlet, and make up tank each. The conctor shall submit schematic arrangements of all components of SWH and get it approved from GE. The exact location of SWH on roof top of the building shall be decided by the GE.
S & F rotational moulded polyethylene water storage tanks 250 Ltrs Capacity (cylindrical vertical with closed top) mounted on angle iron base frame of 3 Mtr height on roof top for solar water heater including mounting structure as per trade practice or as recommended by manufacturer of solar water heating plant.
(EXTERNAL WATER SUPPLY) Cutting the existing pipe of dia upto 100mm and making new connection including provision of TEE suitable size with all necessary connected works. Note :- Excavation and earthwork shall be measure and paid separately.
(EXTERNAL ELECTRIC SUPPLY) M&L for bricks with fly ash bricks laid dry in trenches or cable protection complete all as specified & directed..
Supply and fixing of all in one integrated solar hybrid street light, with solar PV modules, Lithium lon maintenance free batteries and LED light all in one unit with occupancy sensor feature complete with the following specification all as specified and as directed:- (i) System Watts/lumens:- Max 12W/Total system lumen not less than 2000 Lumens. (ii) Housing:- Extruded high grade aluminium die cast (iii) IP rating:- IP 65 (iv) Front cover:- Acrylic/ polycarbonate cover (v) Mounting:- Suitable for bracket mounting and flexibility of angle adjustment (vi) Finish:- Smooth finish (vii) Lamp:- High bright LED (viii) System Efficacy (Im/Watt):- Not less than 175 lumens/Watt (ix) Colour temperature:- Not less than 5700 K (x) Colour rendering index (CRI):- Not less than 80 (xi) Guaranteed Life:- Not less than 50000 hrs of operation (xii) Optics:- Designed for optimum light distribution (xiii) Control gear:- Inbuilt electronic driver with factory configured for LED load and PIR sensor with dimming profile, smart self diagnosis feature with LED indicator, along with battery charging and deep discharging indicator, intrigated microcontroller based MPPT charger and driver for main supply and solar charging, motion sensor, PRI sensor, switch On/OFF indicator, with the standard operating voltage 180-270V Ac, 50Hz (xiv) Surge protection:- Inbuilt surge protection minimum 2KV. (xv) Heat sink:- As per OEM's design (xvi) Battery:- Lithium Ferro Phosphate battery (LIFePO4) with minimum 256Wh capacity, 12V DC (xvii) Solar Module shall be 12V, 35Wp, mono crystalline, with min 17% efficiency.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Meter deep below normal ground level) with tip edge of plate not less than 1.5 Meter below normal ground level connected to galvanized iron earth wire 6 mm as earthing lead by means of bolts, nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earthwork, supplying and laying charcoal dust, common salt PCC (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia CI funnel and wire mesh, 20mm dia GI pipe light graded for watering all as shown in drawing and connected to earth test point including testing complete all as specified and directed
Supply and Fixing LED Bollard for landscape lighting 9/10W, IP 65, AC 230V, 50 Hz, complete with housing, fixing arrangement on PCC base, electrical connection all as directed.
Supply & fixing street light junction box made up of PVC material with UV treated of size not less than 25cm x 20cm x 10cm with locking arrangement inclusive of 20 x 3mm thick aluminium bus bar (for 3 phase and neutral) of suitable length incl MCB SP 5 amp - 01 No, fixed in and including insulators for mounting bus bar (with provision of cable entry and exit conduit), fixed with necessary flat iron clamp of size 25mm x3 mm 2 Nos (length as reqd to fix in pole), bent to required shape including painting, at bottom portion of the pole (above coping), fixed with GI bolts, nuts and washers (of suitable size), complete all as specified and as directed by the engineer-in-charge (make: Sintex / Havels / Hansel or equivalent as approved by accepting officer)
Supply & fixing bracket / arm suitable for street light fittings, made out of 40 mm bore (light grade) GI pipe length not exceeding 1.5 mtr long, fixed with 02 sets of flat iron clamp of size 25mm x 5mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by the engineer-in-charge
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Meter deep below normal ground level) with top edge of plate not less than 1.5 Meter below normal ground level connected to GI strip 25mmx4mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel all as shown electrical plate No 3 of SSR Part-I and including excavation and earthwork, supplying and laying charcoal dust, common salt PCC 1:3:6 type CI chamber and MS angle iron frame 40x40x3mm RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia CI funnel and wire mesh, 20 mm dia GI pipe light graded for watering all as shown in drawing and connected to earth test point including testing complete all as specified and directed .
Design, Supply, Installation, testing and commissioning of Wind and Solar Hybrid Energy System, based on modular, scalable, distributed renewable energy system designed and optimized for ON Grid installations, utilizing low profile vertical axis wind turbines (VAWT) mounted on a single base and solar panel and inverter complete with the following specifications: - Performance advantages: - (i) Roof Top wind and solar Hybrid Energy System (ii) Stable 24 hrs power generation capability (iii) Mechanical breaking of high speed winds beyond 18.5 meters per second (iv) Appropriate for On Grid application (v) Online tool for power generation monitoring (vi) Power generation starting at 2m/Sec wind speed. Technical Features: - (i) Low profile vertical axis sabonius wind turbines, cut-in speed 2m/Sec and Cut-out wind speed 18.5m/Sec (ii) Scalable to user defined KW need (iii) Integrated Maximum Power Point Tracking (MPPT) (iv) (MPPT) with smart bus logic control technology- 48V DC (v) Easy assembly and maintenance (vi) Temperature sensing electronics for thermal protection (vii) Able to withstand temp ranges from -30°C to 50° C (viii) Easy to mount on an stricture (ix) Ballasted or roof penetration stricturesTechnical Details & specifications (i) Dimensions: - Approximately- Length- 3100mm, width- 2555mm, height- 1900mm (dimension should be within the range of ± 10% of the indicated dimension) (ii) Weight: - Approximately 250-300 Kgs (iii) Cover materials: - UV Resistant HDPE (iv) Frame: - Galvanized G-90 Steel or aluminium (v) Electronics enclosure rating: - IP 53 (vi) Electrical connection: - On Board Batter Charge controller with Grid tied Inverter (vii) Wind generator type: - Permanent magnet axial Gap or equivalent (viii) Guaranteed life: - 25 Years (ix) Wind component Max power output: - 1000W@ 16-18m/Sec (x) Max DC voltage: - As per system design (xi) Max Solar Power out put: - 1500W (xii) Max solar panel voltage: - as per system design (xiii) Grid synchronisation voltage: - 415V, AC, 50 Hz, 3 Phase. (xiv) Solar Panels: - As per MNRE approved and guidelines (xv) Note: - All electrical connection required for parallel operation of two independent units and evacuation of power from proposed location at roof top of the building to main distribution of the building shall be deemed to be inclusive in the unit rate quoted. Make: -"Wind Stream technology, Model- Solar Mill SM2-6P or equivalent an other make.
(HOT WATER SUPPLY) Supply, Install, Testing and Commissioning of storage water heater/Geyser 15 litres with all standard accessories complete with 2 Nos. inlet and outlet pipes for hot and cold water as standard fittings and complying the followings specifications:- (i) type:- Vertical (ii) Capacity of inner tank: 15 Litres (iii) Colour: White (iv) Temperature sensitive LED indicators (v) Feather touch digital temperature control (vi) Shock proof 3 pin plug (vii) Up to 8 bar pressure resistant inner tank (viii) Multifunctional safety valve (ix) IPX4 technology to protect electrical parts from water splash (x) Earth Leakage current breaker to cut off power immediately in case of current leakage and protect user from electric shock (xi) Built in Thermostat (xii) built in thermal cut-off (xiii) Tank: Made with ultra thick super cold steel plates dry powder coating finish and energy saving high density PUF insulation (xiv) Heating element-Glass coated heating element with resistant to oxidation and carbonation at high temperature of 2000W capacity. (xv) Heavy duty magnesium anode rod with steel core to protect anamelled tank from rust and corrosion (xvi) 230V, single phase, 50 Hz AC Power supply operated. (xvii) 5 STAR energy saving rating with BEE Label. (xviii) make:- Havells, model-Adonia
Supply & fixing LED post top latern LED 40W made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection complete and as the direction by Engineer-in-Charge
Supply and fixing street light junction box made up of PVC material with UV treated of size not less than 139mm x 119mm x 70mm with locking arrangement inlcusive of 20 x 3 mm thick aluminium bus bar (for 3 phase and neutral), fixed in and including insulators for mounting bus bar (with provision of cable entry and exit conduit), fixed with necessary flat iron clamp of size 25mm x 3mm - 02 Nos (length as reqd to fix in pole) bent to required shape including painting, at bottom portion of the pole (above coping), fixed with GI Bolts, nuts and washers (of sutiable size), complete all as specified and as directed by Engr-in-Charge.
S&F LED street light 25 W with pressure die-cast housing alongwith prismatic polycarbonate diffuser and LEDs with secondary optics and IP 65 protction as specified and directed by the Engr-in-Charge
M&L cutting or drilling of existing pipe line any size and any type upto 200mm dia for making new connection by way of inserting of suitable size of Tee or ferrule including necessary connected works including Tee or ferrule etc complete all as directed.
Prasur Electricals & Engineering Co.
MS SHRI B.C. DAS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .