Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹60,578
Closing Date
30 Sept 2026, 5:00 pm3d left
smtgcunnao
transgangacityunnao
Providing and fixing of Gantry Sign boards, Road direction boards for I.A. Unnao, Site-1, Site-2 and I.A. Banther, Distt-Unnao
2026_SIDC_1183892_1
cd_tgc_253_dt_14072025
Open Tender
Civil Works
Percentage
120 days
unnao
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,717
upsida
₹60,578
9 Sept 2026
9 Sept 2026
1 Oct 2026
9 Sept 2026
30 Sept 2026
9 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work in excavation for structure as per drawing and technical specification clause 305.1 including setting out, construction of shoring and bracing removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. | 7.78 | Cum | 135 | ₹1,050.3 |
| 2 | Providing and laying cement concrete 1:2:4 (1 cement, 2 coarse sand, 4 graded stone ballast 20 mm nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation & floors. | 9.72 | CUM | 7,185 | ₹69,838.2 |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for - Foundations, footings, bases of columns, etc. for mass concrete | 64.8 | SQM | 169 | ₹10,951.2 |
| 4 | Mild steel or iron work in heavy sizes such as trusses builts up gates, door frames, reocrd racks, roof work, gates etc, wrought to required form including drilling holes, rivetting or welding where necessry and also including supply of steel, bolts, nuts etc & their fixing required for proper completion of the work. | 17.54 | Qtl. | 7,995 | ₹1,40,232.3 |
| 5 | 12 m-15 m Span Over Head Structure with 300 dia M S two vertical post
Supply, fixing & eraction of built up Overhead Structure of 12M-15M span comprising of two vertical posts of 6.00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10 mm MS plate at top & 12 mm M S plate at bottom. The horizontal Truss shall comprise of 50 mm dia heavy class M.S. pipe and 40 mm dia heavy M. S pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant. The work includes construction of RCC Foundation of size 0.90x0.90x1.50 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1:3:6 (cement coarse sand and 40 mm gauge stone ballast and RCC M-25 cement concrete including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete. Installation work shall be as per relevant clauses of MORT&H specification section 800 and IRC 67 2012 complete in all respect. The Rates shall include cost of design, fabrication, supply, transportations, Local shifting Erection of Signage structure using crane, inclusive of all taxes etc. all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in-charge. | 6 | No. | 2,32,222 | ₹13,93,332 |
| 6 | Retro-Reflective Sheeting type-XI with 4 mm thick ACM Single Side
Providing & fixing of reflective signs with a corrosion resistant 4 mm thick with 0.4 to 0.5 mm both side aluminium skin aluminium composite panel face to be fully covered with High Intensity prismatic sheeting type IV as per IRC-67:2012 retro reflective sheeting with back frame MS angle of 35x35x5 mm. Legends, letters, numerals and borders etc should be as per MoRTH specification No-801.3.7 The sheeting shall have a pressure - sensitive adhesive of the aggressive tack type requiring no heat. solvent other preparation for adhesion to a smooth clean surface, in a manner recommended by the sheeting manufacturer. The ACM (Aluminium Composite Materials) shall be fixed on the Back frame MS Angle with riveting. Micro prismatic type IV Retro reflective sheeting confirming to ASTM D4956-09 shall be Pressure fixed. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from International condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & Proof of the same Report shall be uploaded which quoting tender. The rate shall include all materials, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge | 143.44 | Sqm | 6,633 | ₹9,51,437.52 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
etenderdocument.pdf
Tender Documents • 0.95 MB
Specialcondition.pdf
Tender Documents • 1.20 MB
feeformatn.xls
Tender Documents • 0.02 MB
BOQ_2226801.xls
BOQ • 4.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .