Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹46.5 L+₹6.0 L (14.9%)Rejected-Finance | L2 | Rejected-Finance As per PQ |
| Sl No | Description | Qty | Unit | Unique Facade Solution L2 | STALWART ARCHITECTURAL SOLUTIONS L1 |
|---|---|---|---|---|---|
| 1.00Replacement of Multiwall Polycarbonate and Galvanized Iron Sheet at Atrium Roof in TIDEL Premises. | |||||
| 1.10 | Removing of Existing Polycarbonate sheet and strengthening for Aluminium/Steel section. Safely, removing work, engaging skilled labour, and use of tools, equipment, and machinery, including scaffolding and transport charges. Debris moving away from the site. (Including labour and transport charges) | 3,600 | sqft | 130 ₹5,52,240 | 100 ₹4,24,800 Lowest |
| 1.20 | Supply and fixing Multiwall polycarbonate sheet - 16mm thick, UV protected on both sides. Solar ice white - Accessories: Panel, Polycarbonate joiner - 12m, Endcap for polycarbonate joiner, Aluminium joiner C 6m Anodized finish, End cap for Al. joiner C Mill finish (natural), Al. Sealing strip - 6m Anodized, Polycarbonate U- Profile - 6m clear, T-Fastener, T-Stopper, Aluminium Span-Bar, Al. F-Profile , Metal Screw, Weeld Screw, Aluminium U-Profile - 6m (Aluminium Anodized). installation would require skilled labours and Interlocking panels and Observations - suits well for high rise atriums & air conditioned spaces. Including special scaffolding and use of fall protection construction safety net and Lifting and Labour charges and all fittings accessories etc.,( Octagonal shape Atrium area ) | 3,600 | sqft | 525 ₹22,30,200 Lowest | 560 ₹23,78,880 |
| 1.30 | Removing of Existing Galvanized Iron sheet and strengthening for Aluminium/Steel section. Safely, removing work, engaging skilled labour, and use of tools, equipment, and machinery for safety. Including special scaffolding and use of fall protection construction safety net and Lifting and Labour charges | 4,800 | sqft | 130 ₹7,36,320 | 100 ₹5,66,400 Lowest |
| 1.40 | Supply and fixing of Precoated Galvanized Iron Atrium Roofing Sheet 0.55mm thick using self drilling/ self tapping screws complete: Welding/ cutting work including scaffolding, lifting of GI Roof sheet to Terrace Area. (Brand – TATA / JSW) | 4,800 | sqft | 200 ₹11,32,800 | 120 ₹6,79,680 Lowest |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
10 Jul 2025, 3:00 pmClosed
Managing Director
No.4, Rajiv Gandhi Salai Taramani, Chennai - 600113.
E-TENDER FOR REPLACEMENT OF POLYCARBONATE AND GI SHEET AT ATRIUM ROOF IN TIDEL PREMISES
2025_TIDEC_572566_1
TIDEL/2025-26/06
Open Tender
Civil Works
Supply
60 days
M/s Tidel Park Ltd
As per Tender
2 documents required · 2 mandatory
₹0
₹54,000
M/s Tidel Park Ltd
10 Oct 2025
23 Jun 2025
11 Jul 2025
23 Jun 2025
10 Jul 2025
2 Jul 2025
23 Jun 2025 - 27 Jun 2025
27 Jun 2025
Amount
Replacement of Multiwall Polycarbonate and Galvanized Iron Sheet at Atrium Roof in TIDEL Premises.
Removing of Existing Polycarbonate sheet and strengthening for Aluminium/Steel section. Safely, removing work, engaging skilled labour, and use of tools, equipment, and machinery, including scaffolding and transport charges. Debris moving away from the site. (Including labour and transport charges)
Supply and fixing Multiwall polycarbonate sheet - 16mm thick, UV protected on both sides. Solar ice white - Accessories: Panel, Polycarbonate joiner - 12m, Endcap for polycarbonate joiner, Aluminium joiner C 6m Anodized finish, End cap for Al. joiner C Mill finish (natural), Al. Sealing strip - 6m Anodized, Polycarbonate U- Profile - 6m clear, T-Fastener, T-Stopper, Aluminium Span-Bar, Al. F-Profile , Metal Screw, Weeld Screw, Aluminium U-Profile - 6m (Aluminium Anodized). installation would require skilled labours and Interlocking panels and Observations - suits well for high rise atriums & air conditioned spaces. Including special scaffolding and use of fall protection construction safety net and Lifting and Labour charges and all fittings accessories etc.,( Octagonal shape Atrium area )
Removing of Existing Galvanized Iron sheet and strengthening for Aluminium/Steel section. Safely, removing work, engaging skilled labour, and use of tools, equipment, and machinery for safety. Including special scaffolding and use of fall protection construction safety net and Lifting and Labour charges
Supply and fixing of Precoated Galvanized Iron Atrium Roofing Sheet 0.55mm thick using self drilling/ self tapping screws complete: Welding/ cutting work including scaffolding, lifting of GI Roof sheet to Terrace Area. (Brand – TATA / JSW)
Unique Facade Solution (BID ID -1397388)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .