Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC | L1 | Accepted-AOC Being Rate Reasonable | |
| 2 | L2₹20.6 L+₹73,367 (3.70%)Rejected-Finance 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹20.9 L+₹1.1 L (5.58%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹22.6 L+₹2.8 L (14.1%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹24.6 L+₹4.8 L (24.1%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
6 Sept 2021, 6:00 pmClosed
GE (C) KIRKEE
GE (C) KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
REPAIR MAINTENANCE RELACEMENT OF FLAME PROOF LIGHTS AC WATER COOLERS AND VARIOUS APPLIANCES AT VARIOUS LOCATIONS UNDER AGE EM II IN GE C KIRKEE
2021_MES_468517_1
8498/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (C) KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE (C) KIRKEE
₹60,000
Yes
7 Oct 2021
16 Aug 2021
7 Sept 2021
16 Aug 2021
6 Sept 2021
31 Aug 2021
16 Aug 2021 - 30 Aug 2021
Amount
Disconnecting split/window type AC (Out door+Indoor unit) 1.5/2 TR electrically/mechanically and lowering to the ground fixed in any position for servicing/repairing/overhauling/cleaning, and cleaning filters, checking of electrical wiring, cleaning of dust by blower and washing with washing soda including replacement of unserviceable, burnt out spare parts to make it fully functional, after repair and re-installation and testing on full load completion to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site. Note :- Item replaced shall be measured and paid separately under relevant item of BOQ.
Disconnecting Water cooler of 60/40/80/100/120 Ltr electrically/mechanically for repairing/overhauling/cleaning, checking of electrical wiring, cleaning of dust by blower including replacement of unserviceable, burnt out spare parts such as relays thermostates etc to make it fully functional, after repair and re-installation and testing on completion to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site.Note :- Item replaced shall be measured and paid separately under relevant item of BOQ.
Supply and fix micro processor printed circuit board complete suitable for split type AC of 1.5/2 TR as suitable for existing make/model and capacity 1.5/2 Ton complete all as specified and as directed by Engineer in Charge.
Disconnecting and taking out old defective Hermatically sealed compressor unit as required for AC and S&F for fixing new compressor (new sealed unit only) with nut bolt, washer antivibrating bush , brazing work, pressure testing for leakage, vaccumnsing and gas charging etc of capacity 1.5 TR for window/Split AC of the existing makes:-Voltas/Hitachi/Emersion/ Carrier /Shriram(Techmesh) complete all as specified and as directed by Engineer in charge.
All as per item no 4 above but of capacity 2 TR for window/split AC
All as per item no 4 above but suitable for Water cooler of capacity 40ltrs.
All as per item no 4 above but suitable for Water cooler of capacity 60ltrs.
All as per item no 4 above but suitable for Water cooler of capacity 80ltrs.
All as per item no 4 above but suitable for Water cooler of capacity 100/120ltrs.
S & F in replacement thermostate suitable for water cooler/ refrigerator/ AC of any type and any model complete all as specified and as directed by Engineer in Charge.
M&L for replacement of overload protection relay for window AC, water cooler and refrigaretor of make and model as per existing model complete all as specified and as directed by Engineer in Charge.
M&L for replacement of starting relay for window A/C water cooler & refrigaretor of make and model as per existing model complete all as specified and as directed by Engineer in Charge.
S & F in replacement of running capacitor 10 MFD complete all as specified and as directed by Engineer in Charge.
S & F in replacement of running capacitor 25 MFD complete all as specified and as directed by Engineer in Charge.
S & F in replacement of running capacitor 36 MFD complete all as specified and as directed by Engineer in Charge.
S & F in replacement of running capacitor 40/45 MFD complete all as specified and as directed by Engineer in Charge.
S & F in replacement of starting capacitor 60 MFD complete all as specified and as directed by Engineer in Charge.
S & F in replacement of starting capacitor 80/100 MFD complete all as specified and as directed by Engineer in Charge.
S & F in replacement of starting capacitor 120 MFD complete all as specified and as directed by Engineer in Charge.
S & F in replacement of PVC float valve for water cooler of size 15mm dia complete all as specified and as directed by Engineer in Charge.
S & F in replacement of drier filtter for AC/water cooler/refrigaretor complete all as specified and as directed by Engineer in Charge.
S & F in replacement of capillary tubing of any size not less than 0.5 mtr for AC/Water cooler/refrigerator complete all as specified and as directed by Engineer in Charge.
S & F for PVC drain pipe suitable for water cooler out let of any capacity complete all as specified and as directed by Engineer in Charge.
S & F in replacement 3 pin plug top of capacity 15 amp complete all as specified and as directed by Engineer in Charge.
S & F of Copper Condenser unit assembly for window AC with all accessories complete of capacity 1.5/2 ton complete all as specified and as directed by Engineer in Charge.
S & F in replacment of suction valve for split AC of any capacity complete all as specified and as directed by Engineer in Charge.
S & F for PVC drain pipe suitable for split AC out let of 1.5T/2.T capacity complete all as specified and as directed by Engineer in Charge.
S & F in replacment of discharge valve for split AC of any capacity complete all as specified and as directed by Engineer in Charge.
Replacement of rubber gasket for lid top of any size for water coolers complete all as specified and as directed by Engineer in Charge.
Supply and fix hermatically sealed unit new Compressor by dismantling burnt out unserviceable Compressor suitable for refrigirators with and including bushes, sleeves, washers nut and bolt for Compressor foundation legs, relay terminal cover clips and including cutting, brazing, leak detection, charging refrigerent and commissioning testing for 165 - 200 ltr capacity complete all as specified and as directed by Engineer in Charge.
Disconnecting Electric conection, removing/transporting the unserviceable water cooler of capacity 40 ltrs to 120 Ltrs to workshop for painting work which includes removing the existing deteriorated/rusted body for paint by scrapping and filling of cavaties with filler spray, denting/ welding, patch work with existing size of MS sheet and painting the body with synthetic enamel paint two coats over a coat of red oxide primer and marking the SM/MES No (of reqd size and shape) with black paint complete all as specified and as directed by Engr-in-Charge.
M & L for cleaning gas system of split AC/Window type AC with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas (Refrigerant R-22) including brazing/testing and commissioning complete of size 1.5/2 Ton capacity complete all as specified and as directed by Engineer in Charge.
M & L for cleaning gas system of split AC/Window type AC with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas (Refrigerant R-32) including brazing/testing and commissioning complete of size 1.5/2 Ton capacity complete all as specified and as directed by Engineer in Charge.
M & L for cleaning of gas system of the water cooler/ refrigerator with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas ( R-134) including brazing/testing and commissioning complete of capacity 40/80/100/120 ltrs complete all as specified and as directed by Engineer in Charge.
M&L for replacement of unserviceble & damaged burnt blower motor/fan motor Window/Split AC of capacity 1/6 HP complete all as specified and as directed by Engineer in Charge.
--- ditto ---- but of size 1/4 HP
M&L for replacement of unserviceble & damaged burnt blower motor/fan motor of Water cooler of capacity 1/8 HP complete all as specified and as directed by Engineer in Charge.
--- ditto --- but of capacity 1/3 HP
--- ditto --- but of capacity 1/2 HP
M & L for dismantling of existing unservicebale voltage stablizer for repairs with replacement of relays electronic voltage sensor circut and meter, micro switch, indication light RC filters and other connected items for making functional and rewinding of unserviceable transformer with super enameled copper wire of appropriate size, varnishing assembling and testing complete of capacity 2 KVA to 5 KVA upto satisfactory function of any capacity complete all as specified and as directed by Engr- in-Charge.
S&F of Heavy duty air conditioner outdoor unit stand/ brackets with complete accessorise for windos/split AC of capacity of 1.5/2 Ton complete with grouting nut bolts complete all as specified and as directed by Engr-in-charge.
S & F in replacment of Copper Condenser unit assembly for Outdoor Unit with all accessories suitable for split AC of capacity 1.5/2 ton complete all as specified and as directed by Engineer in Charge.
Dismantling of old split type air conditioner indoor unit and Supply , installation and testing Indoor unit of split type air conditioner complete with cordless remote control and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 Ton with wall mounted fixing plate suitable size incl breezing work for fixing existing site complete all as specified and as directed by Engineer in Charge.
Disconnecting and taking down unserviceable/damage outdoor unit cover of split air conditioner of capacity 1.5 Ton and dismantaling of compressor ,condenser unit,wiring,fan motor from outdoor cover and supply and fixing new outdoor cover with replacement of unserviceable spare parts such as capacitor ,control wiring and refixing compressor ,condenser unit,wiring,fan motor to make it fully functional, after repair and re-installation as per existing and testing on completion to the entire satisfaction of Engr-in-Charge. Note :- Items as declared unservicable by Engineer in charge shall be replaced by the contractor. Such items shall be measured and paid separately under relevant item of this BOQ.
Supply and fixing sub main wiring of two single core FRLS-H PVC insulated unsheathed stranded copper conductor cables of size 4 Sqmm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit of 1.2 mm wall thickness including all fixing accessories, and 4 sqmm PVC insulated stranded copper conductor cable as earth wire connected to earth dolly complete all as specified and directed by Engineer in Charge. Note:- Two lengths of running cables and one length of earth wire including one length of pvc conduit pipe shall be measured & paid for as single length.
Supply and fixing sub main wiring of two single core FRLS-H PVC insulated unsheathed stranded copper conductor cables of size 6 Sqmm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit of 1.2 mm wall thickness including all fixing accessories, and 6 sqmm PVC insulated stranded copperconductor cable as earth wire connected to earth dolly complete all as specified and directed by Engineer in Charge. Note:- Two lengths of running cables and one length of earth wire including one length of pvc conduit pipe shall be measured & paid for as single length.
Supply & fixing of MCB's 240V confirming to IS of rating 6A to 32A SP, ' C' Series, 10 KA breaking capacity complete all as directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin and earth plug and socket complete with one no MCB SP , 20 Amps , 230 volts complete all as specified and as directed by Engineer in Charge.
S & F of Flexible multi stranded PVC insulated and sheathed copper cable of size 2.5 sqmm 3 core cable complete all as specified and as directed by Engineer in Charge.
Dismantling and Taking down unserviceable existing light fittings 1X 40 Watt / 2X 40 Watt /flame proof fittings of any size and capacity from any location/height after disconnecting of electrical connection including all connected accessories completre all as specified and as directed by Engr-in-Charge.
Supply and fix Flame proof - weather proof flood light fitting 60 watt LED with LED flameproof wellglass in die cast aluminium housing having with heat resistance toughened glass IP 65 protection, 100/lum W (5700 ICT), PF>0.90, THD 10% complete all as specified and as directed by Engineer in Charge. Make crompton Cat No FWL1315-60CDL or equivalent from list of make as approved by GE.
Material and Labour for for Copper piping 5/8" (18/20 gauges) with necessary fitting such as elbow bends sockets and tee's, clamps and supports on wall and grounds complete all as specified and as directed by Engineer in Charge.
Material and Labour for for Copper piping 1/2" with necessary fitting such as elbow bends sockets and tee's, clamps and supports on wall and grounds or frame etc. complete all as specified and as directed by Engineer in Charge.
Material and Labour for for Copper piping 1/4" with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds complete all as specified and as directed by Engineer in Charge.
Supply and fix linear susended light fitting 30 W LED with aluminium extruded owder coated white housing in built up electronice LED driver having heat resistance IP 20 protection.fixing arrangements for light fitting to steel trusses / false ceiling/ ceiling suspended by 2 nos. Ø19/20 mm rigid stove enamelled black steel conduit with bell mouth threaded sockets or with chains complete including dismantling of old fittings all as specified & directed with complete assesories all as specified and directed by Engr In charge.Cat no:- LM31-401-XXX57WG1 of Make wipro or equivalent from list of make as approvd by GE. Note- -1. Stove enamelled black steel conduit or cahin only will be measured and paid under relevant items of this schedule. 2 ; Quoted rate is deemed to be inclusive of conduit fittings and bell mouthed threaded sockets.complete all as specified & directed. 3 ; Quoted rate is deemed to be inclusive any misc materials required for fixing new luminaries.
Dheer Engineering
Om Construction
M/S. Niksun Electro-Infra Private Limited
M/S - FRONTLINE ELECTRO SYNDICATE
Mahindra Electric Stores
K.K.Enterprises
GRACE CONSTRUCTIONS
M/S - KRUPA ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .