Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹39.8 L+₹1.6 L (4.30%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Approved for opening of financial bid as documentation incomplete as the firm has not been submitted the reply of e-mail |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
17 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR PIN-273008
PROVISION OF CERTAIN SANCTIONED WORKS AT GRD KUNRAGHAT UNDER GE (AF) GORKHPUR
2022_MES_501950_1
8774/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE(AF) GORAKHPUR
₹78,000
Yes
9 May 2022
17 Jan 2022
19 Feb 2022
17 Jan 2022
17 Feb 2022
5 Feb 2022
60 days
Amount
Dismantling brick or brick tiles laid bedded and pointed in any type of mortar as on roof etc complete all as specified and directed.
Dismantling/ Demolition /striping out of existing roof treatment (tarfelt & roof plaster etc) including PCC padding of any description, and any thickness including backing, and remove the debris complete all as specified and directed.
Roughening surfaces of old concrete floor by sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified & directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof padding to maintain proper slope mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag, complete all as specified and directed. Note:-WPC will be measured & paid separately)
M&L for 10 mm thick rendering on fair faces of brick work or on concrete surface in CM 1:3 finished surface even and smooth without using extra cement mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag complete all as specified and directed. Note: WPC will be measured and paid separately.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in roof kerb or mud stops, rounded or chamfered on edges surface finished even and smooth without using extra cement, mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag complete all as specified and directed. Note: WPC will be measured and paid separately.
M&L for providing roof treatment as per latest zonal specification specified:- (a) Applying a coat of bitumen primer @ 0.25 ltrs/sqmts and allow to dry. (b) Applying one coat of hot blown bitumen grade 85/25 @ 1.20 Kg/sqmts. (c) Applying 3mm thick APP modified polymeric water proofing membrane of weight not less than 3.0Kg/Sqm laid and bonded to the sub strata by heat process, over laps of 100mm shall be sealed/fused by flame torch application as per manufacturer instructions.
M&L for applying a tack coat of hot blown bitumen grade 85/25 @ 0.20 kg/sqmts and blinding with coarse sand dry @ 0.50 to 1.00 Kg/sqmts dusted over bitumen and aluminium paint @ 0.20 Kg/Sqm in two coats over APP membrane complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Demolition of reinforced concrete of any description & in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Taking up or down steel tubing and connections 20mm bore complete all as specified and directed.
S&F 20mm bore steel water tubes "medium grade" galvanized with all fittings such as bends, elbows tee etc and fixed to walls and ceiling in floor complete all as specified and directed.
All as per item No. 12 above but 40mm bore.
Dismantling water tanks of capacity exc 250 ltrs but upto 500 ltrs complete all as specified and directed.
Dismantling water tanks of capacity exc 500 ltrs but upto 1000 ltr complete all as specified and directed.
Disconnecting existing tank of capacity 250 ltrs but upto 500 ltrs setting aside for repair cleaning and removing all scale and dirt etc from tank and refixing in position complete all as specified and directed.
All as per item No. 16 above but capacity exc 500 ltrs & n exc. 1000 ltrs.
S&F rotational moulded polythylene water storage tanks 500 ltrs capacity triple layered ISI marked white colour (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
All as per item No. 18 above but 1000 ltrs capacity.
S&F in repair ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe or brass ferrule and fixed of 20mm bore (Minimum weight 210 gms) complete all as specified and directed.
S&F in repairs gun metal gate valves 20mm bore with iron wheel head screwed both ends for iron pipe and fixed to complete all as specified and directed.
Taking down rain water/vent pipe of any description including fittings etc complete all as specified and directed.
S&F mild steel for bands, straps, supports or stays for rainwater, ventilating pipes, caging for PVC water tanks and any type of mild steel work etc. complete all as specified and as directed.
S&F 110mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls or laid in trench complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and pre-cast articles complete all as specified and directed.
M&L for brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Excavation in trenches in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and complete all as specified and directed.
All as per item No. 29 above but for each additional 1.5m or part thereof in depth beyond the first 1.5 m.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exec 25 cm thick complete all as specified and directed.
Removing surplus excavated material exc. 50 mtrs but n.exc 250 mtrs and depositing where directed at a level not exec 1.5 mar above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling or mass concrete complete all as specified and directed.
S&F reinforced cement concrete pipes, class NP-2, laid and jointed complete with collars of 200mm dia complete all as specified and directed.
M&L for 100mm thick concrete bed to drain pipe for 200mm dia incl packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 using 40mm graded mechanically crushed stone aggregate complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in copings, bed plate, roof kerbs or mud stops including weathering, slightly rounded or chamfered angles and throating with necessary form work complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces of wall, finished surface even and smooth without using extra cement complete all as specified as directed.
M&L for pre cast cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
M&L for mild steel TMT bars 8 to 10mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, ends and binding with & including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Cutting into existing manholes for connecting new drains for 200mm bore pipe, good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed.
M/S B.P. CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .