| 1 | L1₹22.8 LAccepted-AOC SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹25.5 L+₹2.0 L (8.34%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹27.3 L+₹3.8 L (16.0%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹28.2 L+₹4.7 L (19.8%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹30.6 L+₹7.1 L (30.2%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹29.4 L
EMD Value
₹58,780
Closing Date
5 Dec 2019, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR REPLACEMENT MAINT OF LT OH LINE UG CABLE SWITCHGEAR INTERNAL ELECTRICAL FITTING FIXTURE REPLACEMENT OF CONVENTIONAL FITTINGS INTO EEL FITTINGS REPAIR TO FAN AND METER AT TB I DEPOT BN BEG CENTRE UNDER AGE EM I C KIRKEE
2019_MES_295950_1
8312/E8 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹58,780
Yes
30 Jan 2020
8 Nov 2019
9 Dec 2019
8 Nov 2019
5 Dec 2019
21 Nov 2019
8 Nov 2019 - 20 Nov 2019
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in soft loose soil.
All as per item No. 1 above but depth exceeding 1.5 m and not exceeding 3 m complete all as specified
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
M&L for sand for cousioning of UG cable/at cable trenches inside substation building.
M&L for brick protection with sub class 'B' brick for UG cable.
Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core with required aluminium cable lugs, heat shrink joints, Colour code heat shrink sleeves at both cable ends all as specified and directed. Note: (i) Heat shrink joint 2 core/4 core will be measured and paid separately under appropriate item of this Schedule. (ii) Serviceable GI tubing obtained from item No-9 here-in-before for cable protection will be refixed/relaid, No extra measurement/payment will be made. (iii) GI tubing required new will be measured and paid separately under respective item of this schedule. (iv) Heat shrink sleeve of 25mm long on HS joint for colour indication will deemed to be included on the quoted rate, (v) Addl aluminium cable lugs require for jointing cable termination will deemed to be included in the quoted rate and no extra measurement/payment will be made.
All as per item No. 10 here-in-before but 10sqmm 2 core complete all as specified
All as per item No. 10 here-in-before but 16sqmm 2 core complete all as specified
All as per item No. 10 here-in-before but 10sqmm 4 core complete all as specified
All as per item No. 10 here-in-before but 16sqmm 4 core complete all as specified
All as per item No. 10 here-in-before but 25sqmm 3,5 core complete all as specified
All as per item No. 10 here-in-before but 50sqmm 3.5 core complete all as specified
All as per item No. 10here-in-before but 70sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 95sqmm 3.5 core complete all as specified
All as per item No. 10here-in-before but 120sqmm 3.5 core complete all as specified
Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board at existing places or carrying to other location, 1100 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 25 sqmm 4 core obtained from item no-09 here-in-before with required aluminium cable lugs, heat shrink joints, Colour code heat shrink sleeves at cable ends all as specified and directed. Note: . (i) Heat shrink joint 2 core/4 core will be measured and paid under appropriate item of this Sch as supply only. (ii) Serviceable GI tubing obtained from item No-9 here-in-before for cable protection will be refixed/relaid, No extra measurement/payment will be made. (iii) GI tubing required new will be measured and paid separately as supply only
All as per item No. 20 here-in-before but 35 sqmm 3.5 core to 120 sqmm, 3.5 core complete all as specified and directed
All as per item No. 20 here-in-before but 150 sqmm 3.5 core to 400 sqmm, 3.5 core complete all as specified and directed
Dismentling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and kepping aside for refixing or carrying to store for credit
M&L for steel tubular swaged pole complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long).
Dismantling and taking down old/unsv cross arms, bracing, supports etc complete for reuse at site or carrying to store for sch of credit all as specified and directed.
M&L cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
Dismantling and taking down old/unsv ACSR conductor any size complete for reuse at site or carrying to store for Sch of Credit all as specified and directed
S/F ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection all as dercted
Dismantling and taking down old/unsv insulator of any type any size from pole/stay for reuse at site or carrying to store for sch of credit complete all as specified and directed.
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and directed..
S&F shackle type,porcelain vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed.
S&F Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm all as specified and directed.
M/L for Stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismentling unsv one all as specified and directed. (Clamps, loop insulator, earth work, PCC measured separately)
S/F for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismentling taking down unserviceable one all as specified and directed
S&F cradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole incl dismentling taking out unsv cradle guard
S&F earth continuity wire using GI wire not less than 4mm dia on pole incl dismentling taking out unsv GI wire
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 25x4 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI strip 25x4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
M&L for restraining of overhead ACSR conductor of any size of 4 wire 35-45 mtr span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and directed.
M&L for restraining of ACSR conductor of any size of 2 wire 35-45 mtr span on pole after disconnecting all jumpering connections & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and directed.
M&L for restraining of GI Cradle guard hexagonal/rectangular of any size 35-45 mtr span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed.
M&L for restraining of GI wire of any size 35-45 mtr span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed.
Cutting/Trimming of tree branches arround 3.00 meter distance from conductors of 9.00m height over head line of span up to 50 meters including removing of creepers etc from poles.
Cutting/Trimming of tree branches arround 3.00 met distance from conductors of 7.5m height over head line of span up to 40 meters including removing of creepers/vegitation etc from poles
Painting of steel pole any type up to 7.5 meter height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation all as directed by Engr-In-Charge
Painting of steel pole any type up to 9.5 meter height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation all as directed by Engr-In-Charge
Numbering of HT/LT poles serially with letter/number size width and height up to 40 mm in situ with black paint on white back ground.
Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 10-16 sqmm, 4 core , make-Raychem, Cat No-EPKT0003 or equivelent of M-Seal/MS Seal/3M
Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 25-50 sqmm, 4 core, make-Raychem, Cat No-EPKT0019 or equivelent of M-Seal/MS Seal/3Maychem/M-Seal/MS Seal/3M
Supply and fixHeat shrink joint indoor/outdoor LT 1100 volts grade 70-150 sqmm, 4 core, make-Raychem, Cat No-EPKT0035 or equivelent of M-Seal/MS Seal/3M
Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 185-300 sqmm, 4 core, make-Raychem, Cat No-EPKT0051 or equivelent of M-Seal/MS Seal/3M
Supply and fix Heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 4 core, make-Raychem, Cat No-EPKJ0123 or equivelent of M-Seal/MS Seal/3M
Supply and fix Heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4 core, make-Raychem, Cat No-EPKJ0130 or equivelent of M-Seal/MS Seal/3M
Supply and fix Heat shrink straight through joint LT 1100 volts grade 70-150 sqmm, 4 core, make-Raychem, Cat No-EPKJ0137 or equivelent of M-Seal/MS Seal/3M
Supply and fix Heat shrink straight through joint LT 1100 volts grade 185-300 sqmm, 4 core, make-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/MS Seal/3M
S&F street light control gear , incl dismentling taking down unsv one, Make- Legrand, Model-Maxi-rex-4QT-6499 15 or equivelent model of ABB/Schneider/Merlin Gerin
S&F 3 pole power contactor, 415Volts, 40 amps, , incl dismentling taking down unsv one, Make-L&T, Type-ML-3, Cat No-SS90721 or equivelent model of ABB/Schneider
Supply and fix GI tubing light grade 40mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection
Supply only GI tubing light grade 50mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection, ISI marked, for cable protection
Supply only GI tubing light grade 80mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection ISI marked, for cable protection
Supply and fixing PVC insulated, PVC sheathed flat twin core 1100 volts grade, 2.5 sqmm aluminium stranded conductor from OH conductor or from junnction box to street/security/post luminaries all as specified and directed.
Supply and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire from OH conductor to building incl dismentling taking down unserviceable one all as specified and directed.
Supply & fixing 4mm dia Hot Dipped Galvanized Chain Link Fencing with Zinc Coating, including line wires, any type of standards, rails, straining bolts, etc. including provission of binding wire incl dismentling taking down unserviceable one (2.8 Kg per sqm with 2"x2" mess of 3 mm wire)
M&L for mild steel work of angle fixed independently for fencing post and others confirming to Gde Fe 410-A incl cutting to dead end length where required, notching, drilling, fitting and/or welding or connecting with bolts and nuts incl dismentling taking down unsv one complete all as specified and directed.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends or as in horizontal bar for fixing in fencing and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securingwith clips complete for support of chain link fencing incl dismentling taking down unsv one all as specified and directed.
Supply and fix jumper connections of length up to 1.50 met with existing size and guage of ACSR, binding with existing conductors for LT OH lines complete as directed by the Engr-In-Charge.
M & L for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 1100 volts, 25 x 20 cm size
M & L for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 11000 volts, 25 x 20 cm size
Supply and errect Cast Iron HT/LT cable route indicator round shaped 120 mm dia 8 mm thick duly embossed with MES HT/LT Cable fixed on flat iron 25X3 mm thick 300 mm long and grouted in PCC (PCC measured separately)
M & L for street light bracket, made out of 40 mm dia GI pipe, (medium grade) 1.2 meter long bend to shape as required and welded and fixing in position incl dismentling taking down unsv complete all as specified and directed.
M & L for street light bracket, made out of 25 mm dia GI pipe, (medium grade) 0.8 metre long bend to shape as required and welded and fixing in position incl dismentling taking down unsv complete all as specified and directed.
Taking down defective HP SV/HP MV/MH/LED street light fittings any type,any capacity from 7.5 to 9 met height poles and bringing down to ground,carry out necessary repair work including replacement of defective spares required, testing on ground and refixing in its original position to the entire satisfaction of Engr-In-Charge.Note : I ) spares required for the repairs will be measured and paid seperately under relevant items of this schedule. II )small items such as clamps,nut,bolts and washers are inclusive of quoted rates.
Supply and fixing in repair of ballast-70 watts suitable for HPsv lamps.Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of ballast-150 watts suitable for HPsv lamps .Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of ballast-250 watts suitable for HPsv lamps .Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of Porcelain Holder screw type suitable for HP sv lamp 70 watts .Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of Porcelain Holder screw type suitable for HP sv lamp 150 watts .Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of Porcelain Holder screw type suitable for HP sv lamp 250 watts .Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of Ignitor suitable for HP sv lamp 70 watts .Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of Ignitor suitable for HP sv lamp 150 watts..Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of Ignitor suitable for HP sv lamp 250 watts..Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of High pressure sodium vapour lamp 70 Watts..Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of High pressure sodium vapour lamp 150 Watts..Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of High pressure sodium vapour lamp 250 Watts..Make: Bajaj/Crompton/HPL/Philips.
Supply and fixing in repair of PVC flexible cable 1.5 sqmm stranded copper conductor.
Supply and fixing in repair of capacitor 20 MFD, 415 V or 150 watt HPSV/MH luminaries Make, Bajaj/CG/Philips/Havells
Supply and fixing in repair of capacitor 10MFD, 415 V or 70 watt HPSV/MH luminaries Make, Bajaj/CG/Philips/Havells
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one two way light point controlled by two, two way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket all as specified and directed.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
S&F 5 Amp switch piano type single pole one way incl dismentling taking down unsv one all as specified and as directed.
S&F 5 Amp switch piano type single pole two way incl dismentling taking down unsv one all as specified and as directed
S&F bell push piano type one way 240 volt incl dismentling taking down unsv one . all as specified and as directed
S&F socket flush type 6 amps, 5 pin, 230v incl dismentling taking down unsv one all as specified and as directed
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed
S&F lamp Holder insulated body with back plate for batten fitting incl dismentling taking down unsv one all as specified and as directed
S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips
S&F LED lamp 3 watt, CDL, E-14 cap, (Small thread type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips
S&F ceiling rose surface Bakelite three terminal incl taking down unsv one all as specified and as directed.
S&F call bell electric, ding dong, AC 240 volt, 50 HZ. incl taking down unsv one all as specified and as directed.
S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz incl dismentling taking down unsv one all as specified and as directed.
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4085-87 to 4085-95 of Legrand or equivalent of Schneider/ABB.
S&F MCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4086-28 to 4086-36 of Legrand or equivalent of Schneider/ABB
S&F MCB, SPN , 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4086-09 to 4086-17of Legrand or equivalent of Schneider/ABB
S&F MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4087-00 to 4087-02 of Legrand or equivalent of Schneider/ABB
S&F Sheet metal enclosure two way, IP-30 incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No-5077 91 to -5077 93 of Legrand or equivalent of Schneider/ABB.
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 10 of Legrand or equivalent of Schneider/ABB
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 11 of Legrand or equivalent of Schneider/ABB
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts,12 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 12 of Legrand or equivalent of Schneider/ABB
S&F MCB distribution board, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076-70 of Legrand or equivalent of Schneider/ABB
S&F Vertical MCB distribution board, as MCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5077-25 of Legrand or equivalent of Schneider/ABB
S&F Vertical MCB distribution board, as MCCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No-507745 of Legrand or equivalent of Schneider/ABB
S&F Metal plug and socket board with MCB SP 20 amp, 16 KA incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5078 11 of Legrand or equivalent of Schneider/ABB
S&F PVC rectangular switch board of size 300mmx 250mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F PVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F PVC rectangular switch board of size 175mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F PVC rectangular switch board of size 100mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F Hylam Sheet 3mm thick on existing concealled MS/CI ractangular or Squar or round box with 04 nos cadmium coated screws and cup washer incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc incl dismentling taking down unsv one.
S&F Round shaped recess mounted LED Flat panel down lighter, 12 watt (8"dia), suitable for POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-Havells , Cat Part No LHEAABP7L1W012or equivalent in Bajaj/Philips/HPL/Havells
S&F Square shaped recess mounted LED slim Flat panel suitable for fixing in aluminium framed ceilling, 36 watt, 2'x2'size, complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LCPL-36-CDL (2x2) (Aura) or equivalent in Bajaj/Philips/HPL/Havells
S&F LED tube 20 watt to existing fluorescent FTL (T-8) fitting surface mounted after taking downelectronic ballast, internal wiring and complete rewiring with 0.5 sqmm copper flexible conductor from connector block to one end of Bipi holder and including connecting up to ceiling rose with 0.5 sqmm two core flexible copper conductor cable all as specified and directed. Make-Cat Part No HLPLEDT8PCP20CW HPL or equivalemt in Bajaj/Philips/Crompton Greaves /Havells
S&F industrial box type LED Batten with CRCA body, pre coated with white and prewired suitable for LED tube 1x18/20 watt 4'long incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL, Cat Part No-HLPLEDT801WT or equivelent of Bajaj/Philips/CG/Havells
S&F LED batten type tube light, 20 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL, Cat Part No HPLLEDT5PC20W or equivalemt in Bajaj/Philips/CG/Havells
S&F LED batten type tube light, 2'long, 09 watt, 230 Volts , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL Cat Part No-Neptune Gold, HLPT51509PCGCW or equivalemt in Bajaj/Philips/CG/Havells
S&F LED building security light 15 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LSTS-15-CDL or equivalent in Bajaj/Philips/HPL/Havells
REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :- M&L for Rewinding of Ceiling fan 1400 mm sweep after dismenting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Contractor will collect fans from the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Spares require for replacement such as bearing, Bushing, capacitor shall be measured and paid separately as supply & Fixing only. 3. Cost of Connector block and capacitor holder shall be inclusive of the quoted rate.
All as per item No- 132 here-in-above but for Ceiling fan 1200 mm sweep
All as per item No- 132 here-in-above but for Exhaust fan 450 mm sweep industrial type.
All as per item No- 132 here-in-above but for Exhaust fan 300/380 mm sweep industrial type.
All as per item No- 132 here-in-above but for Exhaust fan 225/250/300 mm sweep domestic type.
S&F ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC.
S&F G.M. Bush bearing for ceiling fan as per existing pattern.
S&F capacitor AC for 230 volts 50 Hz of capacity 2.0/2.25/2.5 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 3.15 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 4.0 Mfd.
Painting of ceiling fan 1200/1400 mm including scrapping, cleaning & revmoving dust from the blade and body and applying two coat of enamel paint over, one coat of primer all as directed and specified.
Painting of exhaust fan 450 mm sweep industrial type including scrapping , cleaning & revmoving dust from the blade and body and applying two coat of enamel paint over, one coat of primer all as directed and specified.
Painting of exhaust fan 300 mm sweep ndustrial type including scrapping , cleaning & revmoving dust from the blade and body and applying two coat of enamel paint over, one coat of primer all as directed and specified.
S&F PVC insulated PVC sheathed copper flexible wire multistranded 4sqmm 3 core, ISI marked
S&F in repair thermostat suitable for geysers 25 Ltrs to 50 Ltrs Capacity. Make- Bajaj/Venus/Recold all as specified and directed.
S&F in repair fusible plug suitable for 25 and 50 ltrs capacity Geysers all as specified and directed.
S&F in repair heating element round/triangular bas, push type or thread type including rubber washers for 1.5/2.0 KW all as specified and directed.
S&F in repair inner water container made of SS, vertical or horizontal type for 25/50 ltr capacity geyser all as specified and directed.
S&F in repair of apparatus plate suitable for vertical/horizontal type Geyser 25 or 50 ltr capacity all as specified and directed.
S&F in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450mm long for hot /cold water all as specified and directed.
M&L for testing of earth resistance value of building earth for electrical purpose, using analog/digital earth resistance tester by suitably inserting spikes as per norms and recording earth resistance value of building in presence of MES Rep and User rep and submission of recorded value in form of hard copy duly signed all as specified and directed.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
MANGAL ELECTRICAL STORES
metro electrical services
M/S. OM ENTERPRISES
PAMS ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .