Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹37.9 L+₹1.5 L (4.09%)Rejected-Finance 1ST SHAKUNTALA SADAN 04 RAMPURA BASTI LALGARH BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance DUE TO NOT LOWEST | |
| 3 | L3₹39.5 L+₹3.1 L (8.54%)Rejected-Finance | L3 | Rejected-Finance DUE TO NOT LOWEST | |
| 4 | L4₹43.4 L+₹6.9 L (19.0%)Rejected-Finance | L4 | Rejected-Finance DUE TO NOT LOWEST | |
| 5 | L5₹44.0 L+₹7.6 L (20.7%)Rejected-Finance | L5 | Rejected-Finance DUE TO NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Oct 2022, 6:00 pmClosed
GE North Bikaner
GE North Bikaner
REPAIR REPLACEMENT OF CERTAIN EM WORKS OF INTERNAL WIRING AND CONNECTING WORKS AT AGE MFFR AND REPAIR MAINT OF EXTERNAL ELECTRIC WORKS STEET LIGHTS AND LT UG CABLES AT NORTH CAMP EAST CAMP AND MAHAJAN LUNKARANSAR ASCON NODES AT AGE MFFR UNDER
2022_MES_552732_1
GE (N) BKN TOKEN NO 53 /2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
Mahajan MFFR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE North Bikaner
₹90,000
Yes
14 Dec 2022
19 Sept 2022
24 Oct 2022
19 Sept 2022
17 Oct 2022
3 Oct 2022
Amount
Taking down carefully existing unserviceable Copper/aluminum batten/surface conduit/concealed conduit point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc (including old MS sunken boxes) and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and as directed by the Engr-in-Charge.
Taking down of unserviceable DBs/switch fuses/changeover in sheet steel enclosure complete with MCBs/Fuse/grips any capacity and removing from site and making good disturbed surface of wall, floor etc. Taking after disconnecting all cable complete all as specified and as directed by the Engr-in-Charge.
M&L Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including surface PVC conduit/casing capping/concealed conduit Medium class 20mm dia ISI marked with all fittings such as tees, bends etc terminating in MS sunken box/wooden box/PVC box ( As site requirement) covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’ for one fan or light or 5Amps socket or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, single core as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 3 here-in-before but socket point on the independent board with other switches complete as specifed as directed by Engineer - In - Charge
All as per item No 3 here-in-before but socket point on the same board with other switches complete as specifed as directed by Engineer - In - Charge
All as per item No 3 here-in-before but cable of 2.5 Sq mm for 15 Amp switch socket outlet on independent board including provision of 2.5 Sqmm PVC insulated unshethed multistranded copper conductor as earth wire
All as per item No 3 here-in-before but for one light point control by two way switch complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement LED T5 Batten lightening fixture, energy efficent 18/20 Watt ( 4 feet) complete all as specified and directed by engineer-in-charge
S&F in replacement Decorative ultra slim linear LED T5 Batten lightening fixture, Eco friendly energy efficent 10/12Watt (2 Feet) complete all as specified and directed by engineer-in-charge
Supply & fix in replacement LED bulk head ,09W / 10 W, IP65 diacast aluminium housing powder coating finished complete all as specified and directed by Engineer-in-charge.
S&F in replacement lamp holder PVC/Poly carbonate body with back plate complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Switch piano Single pole 5 Amps, two way, complete all as specified and as directed by Engineer-in-Charge
S&F in replacement switch piano flush type, Single pole 5 Amps, one way, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of socket outlet flush type, 3 pin, 5 Amps, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of switch piano flush type, Single pole 15 Amps, one way, complete all as specified and as directed by Engineer-in-Charge
S&F in replacement of socket outlet flush type, 3/5 pin, 5/15 Amps, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of ceiling fan regulator electronic type, 230 Volt, 150 Watt with 5 step of control including making holes in laminated bakelite sheet cover and connection complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of ceiling rose PVC/poly carbonate insulated body three terminal ISI marked, complete all as specified and as directed by Engineer-in-Charge
S&F in replacement Recessed mounting LED 2x2 luminaire type :- make: CG / Phillips / GE / Wipro / Havell's/Bajaj
Supply and Fixing in replacement MCB single pole, 240 volts of rating 6-32 Amps of C curve breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply C Curve single pole and neutral(SPN) with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in replacement MCB 63 Amps, 440 Volt AC supply Triple pole with neutral(TPN) C curve with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Bell Ding dong AC single pole 230volts
S&F in replacement Bell push button Piano flush type single pole 5Amps.
S&F in replacement sub main wiring in PVC conduit/casing-capping with 2 single core 6 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 6 sqmm copper conductor cable connected to common earth and earth dolly complete and including PVC Cassing and Capping all as specified and as directed by Engineer-in-Charge.(Note two run of 6 sqmm and one run of 6 sqmm will be measured as 1 RM.
All as per item No 32 above but of size 4 sqmm and earth wire of 4 sqmm
All as per item No 32 above but of size 2.5 sqmm and earth wire of 1.5 sqmm
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,SPN 12 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall,and blanking plate as reuired complete all as specified and as directed by Engineer-in-Charge. Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
Ditto item -38 but for 8 way SPN
Ditto item -38 but for 4 way SPN
S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB 20Amps capacity complete all as specified and directed by Engr-in-charge
S&F in replacement Decorative wall / surface light fixture made up of Polycarbonate, suitable for retrofit 9/11 W LED lamp Complete all as specified and directed by Engr-in-charge. Sample as approved by Engr-in-charge
Supply in replacement of LED bulb of capacity 9 watt complete all as specified and directed. Make Havells/Philips/polycab.
Taking down switch boards / fitting / fixture , identify and rectify the complaints pertains to internal electrification of any type and nature of temp/permt OTM Accns such as rectification of faulty electric circuit , tightening of loose wiring/ conduits replacement of defective accessories such as any type switch, socket, ceiling rose, Pvc Board and conduit, lights , MCB any type , holders, wire etc. shall be measured and paid separately. Cost of minor stores , such as screws, clamps, washers, insulation tapes, nut , bolts etc. shall be deemed including in the quoted rate. ( Note . If the contractor fail to rectify the defects mentioned in the complaint slip on within 48 hrs,. he will be charged Rs. 100/- per complaints/ per day and same will be recovered from his RAR . Note for Serial Items No:- :- 34 to 65 ( Fixing in this Job only) The contractor / his rep will collect the complaint from complaint cell ( Concerned JE E/M) every day at 9.00 AM and rectify the complaints 48 hrs and deposit the complaint slip ( duly signed by the users ) to concerned JE E/M.
Supply in replacement LED T5 Batten lightening fixture, energy efficent 18/20 Watt ( 4 feet) complete all as specified and directed by engineer-in-charge
Supply in replacement LED bulk head ,09W / 10 W, IP65 diacast aluminium housing powder coating finished complete all as specified and directed by Engineer-in-charge.
Supply in replacement lamp holder PVC/Poly carbonate body with back plate complete all as specified and as directed by Engineer-in-Charge.
Supply in replacement switch piano flush type, Single pole 5 Amps, one way, complete all as specified and as directed by Engineer-in-Charge.
Supply in replacement of socket outlet flush type, 3 pin, 5 Amps, complete all as specified and as directed by Engineer-in-Charge.
Supply in replacement of switch piano flush type, Single pole 15 Amps, one way, complete all as specified and as directed by Engineer-in-Charge
Supply in replacement of socket outlet flush type, 3/5 pin, 5/15 Amps, complete all as specified and as directed by Engineer-in-Charge.
Supply in replacement of ceiling fan regulator electronic type, 230 Volt, 150 Watt with 5 step of control including making holes in laminated bakelite sheet cover and connection complete all as specified and as directed by Engineer-in-Charge.
Supply in replacement of ceiling rose PVC/poly carbonate insulated body three terminal ISI marked, complete all as specified and as directed by Engineer-in-Charge
Supply in replacement PVC Copper conductor cable 2.5 Sqmm x 02 core for suitable service coonection complete all as specified and as directed by Engineer-in-Charge.
Supply in replacement PVC Copper conductor cable 4.0 Sqmm x 03 core for suitable service coonection complete all as specified and as directed by Engineer-in-Charge.
Supply in replacement Rigid non-metallic PVC conduit of size 20/25 mm dia ( as per site requirement) inclusive of all tees, bends,elbows,juction box, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. all as specified and as directed by Engineer-in-Charge
Supply in replacement PVC casing caping 20/25 mm dia ( as per site requirement) inclusive of all tees, bends,elbows and fixing accessories such as couplers, lock nails, etc. all as specified and as directed by Engineer-in-Charge
Supply in replacement PVC box/ wooden box with sunken box of any size and make as per site requirement " includng 3 mm thick new bakelite laminated sheet top cover ‘Hylam’ suitable for one switch and socket of capacity 5/15Amps all as specified and as directed by Engineer-in-Charge
Supply in replacement PVC flexible pipe of size 20/25 mm dia ( as per site requirement) including PVC clamp etc. complete all as specified and as directed by Engineer-in- Charge.
Supply in replacement Switch socket combination 2 in 1, 5 A flush type complete all as specified and as directed by Engineer-in- Charge.
Supply in replacement Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed by Engineer-in- Charge.
Supply in replacement MCB single pole, 240 volts of rating 6-32 Amps of C curve breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply C Curve single pole and neutral(SPN) with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply only PVC insulation tape for day by day complaint /maintenance all as specified and as directed by Engineer-in- Charge.
S&F in replacement Modular switch 1 way 6A, 1 modul complete all as specified and as directed by Engineer-in-Charge
S&F in replacement Modular switch 1 way 16A, 1 modul complete all as specified and as directed by Engineer-in-Charge
S&F in replacement Socket, 6A - 2/3 pin combined 2 modul complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Socket, 16A - 2/3 pin combined 2 modul complete all as specified and as directed by Engineer-in-Charge
S&F in replacement Fan step regulator, 120W - 2 module complete all as specified and as directed by Engineer-in-Charge
S&F in replacement White cover plate with frame, 1 modul complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement White cover plate with frame, 2 modul complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement White cover plate with frame, 3 modul complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement White cover plate with frame, 4 modul complete all as specified and as directed by Engineer-in-Charge
S&F in replacement White cover plate with frame, 6 modul complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement White cover plate with frame, 8 modul complete all as specified and as directed by Engineer-in-Charge.
REPAIR TO GEYSER Taking down and opening of the geysers 25/35/50 ltrs capacity any make complete for inspection descaling by chemical treatment of internal parts such as steel inner tank, siphon assembly, heating element, etc re-assembling and refixing the same to its original position after testing on pressure complete all as directed by the Engineer-in-charge. Note :- Items such as glass wool, steel inner tank, siphon assembly etc if found unserviceable under above item will be measured and paid for separately under its relevant item .Note for Serial Items No:- :- 73 to 82 The contractor / his rep will collect the complaint from complaint cell ( Concerned JE E/M) every day at 9.00 AM and rectify the complaints 48 hrs and deposit the complaint slip ( duly signed by the users ) to concerned JE E/M. Note :-If the contractor fail to rectify the defects mentioned in the complaint slip on within 48 hrs,. he will be charged Rs. 100/- per complaints/ per day and same will be recovered from his RAR
Supply and fixing in replacement steel inner tank/glass lined tank ( as site requirement) for capacity of geyser 25 ltrs as per existing size and shape.
Supply and fixing in replacement siphon assembly suitable for 25 ltrs Geysers, with rubber washer of suitable size.Make : Marc/Bajaj/Polar or equivalent
Supply and fixing in replacement glass wool insulation material
S&F in repair hot water pipe 15 mm bore 60 cm long with brass unions one(Chromium plated) one on each side. Pipe shall be as per I.S for 15 mm bore of pipe for 25/35/ 50 ltrs capacity Geysers.
Supply and fixing in replacement steel inner tank for capacity of geyser 35/50 ltrs as per existing size and shape.
Supply and fixing in replacement siphon assembly suitable for 35/50 ltrs Geysers, with rubber washer of suitable size.
S&F in repair Thermostat switch I.S.I marked, to Geysers 25/35/50 ltrs of any make / size and shape as per site requirement
S&F Low density polythene pipe (LDPE) connection arrangement with pipe of pressure rating 2.5 kgf/cm2 , 15 mm bore 30 cm to 45 cm long with brass unions one(Chromium plated) one on each side in repair to Geysers 25/50 ltrs. Pipe shall be as per I.S.I
Supply and fix in replacement heating element of rating 1.5 KW capacity including washers for 25/35 ltrs capacity Geysers.Make :- “Marc/THETA/ ALERT”
Supply and fix in replacement heating element of rating 2.0 KW capacity including washers for 50 ltrs capacity Geysers.Make :- “Marc/THETA/ ALERT”
Supply and fix in replacement Indicator lamps as per existing type having red or green coloured reflector all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement flexible, 3 core PVC insulated copper conductor cable of size 40/0.0076 with over all PVC insulation ISI marked.
Supply and fixing in replacement plug top, 3 pin 15 Amps, including making necessary connections .
Supply and fixing in replacement pressure release valve suitable for 15 mm bore of pipe for 25/ 35/50 ltrs capacity Geysers.
Supply & fixing in replacement bib cock cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified.
Supply and fixing in replacement stop cock cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified.
Supply only multistranded copper conductor of size 1.5 Sqmm single complete all as specified and as directed by eng-in-charge Make :- Polycab/Havells/Finolex
Supply only multistranded copper conductor of size 2.5 Sqmm single complete all as specified and as directed by eng-in-charge Make :- Polycab/Havells/Finolex
Supply only multistranded copper conductor of size 4 Sqmm single complete all as specified and as directed by eng-in-charge Make :- Polycab/Havells/Finolex
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I.
Notes for Sl Item No.87 to 143:- 1. Contracotor must attend the complaint within 24 Hours and resolve within 48 hours if failed to attend, peanlaty of Rs 1000 per day will be deducted b) Contractor must deploy a dedicated faullt investigation and rectifying team for this work or as specified by Enginneer in charge.Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge.
All as per Srl item No. 87 here in before but exc 1.5m and not exceeding 3.0 in depth complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by the Engineer-in-Charge.
Protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ burnt-clay bricks having compressing strength not less than 75 kg/Square cm complete all as specified and as directed by the Engineer-in-Charge.
Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations of poles above ground level including finishing to exposed concrete surfaces even and fair and provision of form work for rough finished surface complete all as specified and as directed by Engineer-in-charge.
Plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations for stays and coping complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking down old damaged/broken pre-stressed concrete/steel LT electric poles of any type inclding breaking down existing pcc foundation and removing from site complete all as specified and as directed by the Engineer-in-Charge.
Taking out old U/S panel any type any description and size carefully by disconecting LT cables carefully after ensuring proper shut down incl breaking up old pcc complete all as specified and as directed by the Engineer-in-Charge.
Taking out old U/S street light or street light fittings with brackets from poles, wall etc any type and description complete all as specified and as directed by the Engineer-in-Charge.
Taking out old US/faulty PVC armoured/un-armoured LT under ground cable of size 10 Sqmm to 120 sqmm 2/3 1/2 4 core complete all as specified and as directed by the Engineer-in-Charge.
Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts LT grade of cross-sectional area 06 Sqmm 2 core laid in trenches/through pipe in road crossings/paths/drains/ducts/floors/along poles/walls/ceilings/equipments etc supplied and fixed including commissioning and testing complete all as specified and as directed by the Engineer-in-Charge. Note : (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (ii) Road/boring roads manualy cutting/floor cutting/cutting holes etc in wall required for laying fising of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same.
Ditto All as per srl item No. 99 here in above but aluminium conductor 100 Volts LT of size 10 Sqmm 2 core
Ditto All as per srl item No. 99 here in above but aluminium conductor 1100 Volts LT of size 16 Sqmm 2 core
Ditto All as per srl item No. 99 here in above but aluminium conductor 1100 Volts LT of size 25 Sqmm 4 core
Ditto All as per srl item No. 99 here in above but aluminium conductor 1100 Volts LT of size 35 Sqmm 3.5 core
Ditto All as per srl item No. 99 here in above but aluminium conductor 1100 Volts LT of size 50 Sqmm 3.5 core
Ditto All as per srl item No. 99 here in above but aluminium conductor 1100 Volts LT of size 70 Sqmm 3.5 core
Ditto All as per srl item No. 99 here in above but aluminium conductor 1100 Volts LT of size 95 Sqmm 3.5 core
Ditto All as per srl item No. 99 here in above but aluminium conductor 1100 Volts LT of size 120 Sqmm 3.5 core
Boring of holes under road, pavement, hard standing by manually without damaging of road, material & labour including pipe 80/100 mm dia suitable complete all as specified and as directed by the Engineer-in-Charge. Note; lenth of pipe to be measured and paid seperately under relavant item
Supply and fixing in replacement of LED based street lights, housing made of pressure die cast aluminium alloy with effective thermal management sturdiness. The fixture should have a minimum system efficacy of more than 80 lumen/Watt and a minimum system lumen output of not less than 3600 lumens and maximum system wattage 45 watts. The fuxture shall have a color temperature of minimum 5000k at a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, lngress protection of IP66 (lamps and gear compartment and Mechanical Impact) Resistance Rating of IK>= 05. The fixture should comply with the parameters as per IEC 60598 and IS 10322, and LED drive should apply to IEC 61000-3-2 ed 3.2. per haronics IEC 61347-2-13, 2006 in confirmation with IEC 61347-1 ed, 2.0, 2007 for electrical safety, LM 79 and LM 80 test report needs to be sumitted above parameters. The fixture driver should have an operating voltage range of 140-300V, frequency 50-60 Hz, surge protection not less than 4KV, PF>0.95 and THD<15%. The driver should have double phase protection. LED lights fitting should be suitable for ambient temperature from (-) 10 digree C to (+) 50 digree C, including street light GI bracket 40mm dia bent to shape 1200 and down 15mm Bore GI pipe with GI clamps with junction box for fixing LED light required, with suitable size clamp, nut bolts and washers as per site requirement complete all as specified as directed by Engineer-in-charge. (Note-The manufacture of LED fitting shall give Guarantee for 5 years from the date of installation and complete fixed with suitable bracket & Accessories) Make-Phillips, CG, Bajaj, Wipro, C&S and surya.
Supply and fixing in replacement for two core PVC insulated weather proof cable with aluminum conductor size 4 sqmm (nominal area), & drawing into hollow street light pole from fitting to juntion box or fitting to over head line complete all as specified and as directed by the Engineer-in-Charge.
M&L Pre-stressed concrete poles 9 meter long, 102mm x 172 mm at top and 102 mm x 279 mm at bottom, class 10, complying with requirements of IS-1678, including painting with two coats of synthetic enamel paint (in alternate black & white/yellow strips of 30 cm height) upto 1.5 meter height from top of PCC coping and also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint incl required iron channels/clamps/GI pipe for the protection of flexible cable connecter box with bus bars, bolts & nuts complete all as specified and as directed by the Engineer-in-Charge.
S&F in replacement GI pipe light grade 50 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/Ceiling/along walls/path/drain/floors with and including all necessary clamps, nuts, bolts washers etc all fittings as required complete all as specified and as directed by the Engineer-in-Charge. (Note: - excavation, earth work and same work shall be measured and pain for separately.)
Ditto All as per srl item No 112 here in above but dia of pipe 40 mm.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre depth below normal ground level) with top edge of plate at a depth not less than 1.5 mtr below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 04 mm dia with and including bolts, nuts, check nuts and washers of galvanised iron or steel and riveted to earth plate and one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 15 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and including flatiron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 03 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including neessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed by Engineer-in-Charge. (Notes 1. The rate quoted shall be deemed to include for all the above provisions. 2. PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting maner) .
Cable jointing kit for LT 1100 V cable for straight through end termination (Epoxy), hot shrinkable type joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm 3.5/4 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-charge.make: m seal/dension.
Ditto all as per srl item No. 115 here in above but 70 to 95 Sqmm
Ditto all as per srl item No. 115 here in above but 120 to 150 Sqmm
S&F inreplacement of change over switch 200 Amps, four pole, 415 Volt, cubical type and including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge Make-C&S, Cat part-CSSDF200B4CO or equivalent cat part in make Crompton Greaves/L&T/Siemens/Alstom.
Repair the following work to existing bus bar chamber(pillar box) outdoor cubical type factory made vermin protected dust proof, water proof made out of MS sheet 1.6 mm thick and 50 cm x50 cm x6mm thick angle iron base frame having insulated bus bar aluminum 200amps cap 3 phase with neutral bus bar including fixing in PCC bed block complete all as reqd at site and as directed by Engineer in Charge with following item no 119 -120 welding of brocken/cracked joints of the feeder pillar box
Replacing to locking arrangement of the feeder pillar box as per sample existing.
Painting with one coat of synthatic enamel paint after applying one coat of red oxide as a primer complete all as specified
S&F in replacement of US Feeder pillar box outdoor cubical type factory made vermin protected dust proof with canopy, water proof made out of MS sheet 1.6 mm thick and 50 cm x50 cm x1.6mm thick angle iron base frame having insulated bus bar aluminum 200amps cap 3 phase with neutral bus bar including fixing in PCC bed block complete all as reqd at site of all four camps and DBS as directed by Engineer in Charge.
M&L for Aluminium conductor, steel reinforced (ACSR) of size 3/6x2.59 mm/make including jionting for over head line on pole including binding wire 14 SWG, jumpers line tapes etc complete all as specified and as directed. ( for measurement and payment purpose of ACSR the weight of winding wire shall not be considered.)
M & L for repairing of broken ACSR vessal/ squarel /ferrot/ mink conductor after proper shutdown of electric supply and jumpring / cut points changing the damaged/burned conductor, cable endes, change over MCCBs condutor broken due to wind/storm and binding with the aluminium wire etc and changing the damaged pin/disc insulators and replace the broken conductor, repairing the faults in the 11/0.44 KV outdoor/ indoor electric panels at sub stations complete all as specified and directed by engineer-in-charge.( Note :- cost of fues wire minor spares, aluminium binding wire shall be deemed included in the above quoted item.,(ii) Cost of items that is pin insulator,disc insulator etc. shall be measured and paid seprately under respective items.(iii)contrator take complaints from complaints cell(JE E/M)and rectify the same day and duely signed by the users and deposited the same.one down breakdown/coplaint by attended shall be the each job.
Supplied and fixed in repair Disc type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 145 mm height, 255 mm dia. for working pressure 11000 volts grade, complete all as specified and as directed by Engineer-in-Charge.
Supplied and fixed in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia. for working pressure 11000 volts grade, complete all as specified and as directed by Engineer-in-Charge.
Cable indoor / outdoor end terminals jointing kit for LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material and accessories, thimbles etc suitable for 16 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-Charge.
Ditto All as per Srl item No . 128 here in above but 70 Sqmm to 120 sqmm 3.5 Core
Ditto All as per Srl item No . 128 here in above but 150 Sqmm to 185 sqmm 3.5 Core
M&L for repair in replacement and fixing of Maintenance free battery capacity 80 AH, 12 Volt with proper copper wire complete all as specified & directed.
M&L for repair in replacement and fixing with suitable clamp of LED solar light of capacity 15 watt complete all as specified & directed.
M&L for repair in replacement charger control/circuit for solar battery 12 volt including connecting to existing wiring circuit or complete all as specified or directed by engineer in charge
M&L for repair in replacement of solar plate /Solar Cell Module of capacity 12 Volt 3.25 watt complete all as specified & directed.
. S&F in replcement of MCCB 4 pole 200 Amp, adjustable type 36 KA, 415 Volt including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge. Make- havells/HPL/Legrand
. S&F in replcement of MCCB 4 pole 125 Amp, fixed type 25 KA, 415 Volt including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge. Make- havells/HPL/Legrand
. S&F in replcement of MCCB 4 pole 100 Amp, fixed type 16 KA, 415 Volt including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge. Make- havells/HPL/Legrand
. S&F in replcement of MCCB 4 pole 160 Amp, Adjustable type 16 KA, 415 Volt including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge. Make- havells/HPL/Legrand
Taking down carefully the defective street light fittings 36/45/72 Watt from the poles/walls and refixing the same on poles/walls after repair complete all as directed by Engineer in Charge.( Note: A Team of workers for emergency are avlaible inside the camp for 24 Hours) 1. T&P i.e, ladder and vehicle will provided by the contractor.
Supply and fixing in replacement Driver unit with surge protection suitable for LED street light ftg of capacity 36 to 45 watt. Make – Bajaj/Philips/Crompton Greaves
Supply and fixing in replacement Driver unit surge protection suitable for LED street light ftg of capacity 72 to 80 watt. Make – Bajaj/Philips/Crompton Greaves
90 Degree LED Module 3030SMD 150-160LM/W LED with Array Lens coomplete For Watts 36 to 45 watt.
91 Degree LED Module 3030SMD 150-160LM/W LED with Array Lens coomplete For Watts 72 to 90 watt.
J.D INFRA ENGINEERING
singh enterprises
J.M.D. CONSTRUCTION CO.
ALPHA ENGINEERING COMPANY
DASHMESH ENTERPRISES
Gill Construction Co
M/S Shree Ram Enterprises
VYAS CONSTRUCTION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .