| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹30.7 L+₹5.4 L (21.3%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹30.7 L+₹5.5 L (21.6%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L3 | Rejected-Finance Higher bid value |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
18 Jan 2020, 6:00 pmClosed
CWE AF KALAIKUNDA
CWE AF KALAIKUNDA, KALAIKUNDA AIR FIELD POST, DIST WEST MEDINIPORE,721303
REPAIR AND MAINTENANCEOF AC PLANTS,AHU AND OTHER ALLIED WORKS
2019_MES_308282_1
8338/KKD/30/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AT AF STN KALAIKUNDA
Class D, Category C(I)
2 documents required · 2 mandatory
₹500
Yes
GE AF KALAIKUNDA
₹74,000
Yes
18 Feb 2020
21 Dec 2019
23 Jan 2020
21 Dec 2019
18 Jan 2020
6 Jan 2020
22 Dec 2019 - 28 Dec 2019
Amount
Taking down Central AC plant compressor SMC-6-65 20 TR capacity at I Level lab of 20 TR capacity from the condensing unit base by removing V belt, nut bolt, dismantling of suction, discharge and oil equalizer pit line connection from the AC plant, transporting worn out compressor from the site to the workshop with the help of Hydra crane and returning back after Cleaning and washing the compressor block with CCL solution and drying the the same, spray painting, repair/ replacement of the following unserviceable parts mentioned below :- (a) New piston assembly of standard size-06 Nos (b) Piston ring set of standard size-06 Nos (c) Piston liner of standard size-06 Nos (d) Main crank shaft with bearing set-01 No (e) Connecting rod & bearing set-06 Nos (f) Gudgeon pin with bush -06 Nos (g) Valve plate assembly with suction & discharge reed-06 Nos (h) Gasket set complete -01 No (i) Oil pump complete-01 No (j) Loader assembly-01 No (k) Main shaft carbon seal assembly complete-01 No (l) Supply and charging dehydrated wax free freesol 68 servo lubricating oil- 15 Litres Note: (i)The quoted rate shall deemed to include for the cost of minor parts required for making the compressor fully functional. (ii) Old unserviceable parts obtained shall be deposited in the MES store .
S&F in repair expansion valve required for AC plant of capacity 5.5 TR complete all as specified & directed by the Engr-in-charge.
Ditto all as above item No 2 above but for AC plant of capacity 8.5 TR complete all as specified & directed by the Engr-in-charge.
Ditto all as above item No 2 but for AC plant of capacity 11/14 TR complete all as specified & directed by the Engr-in-charge.
Ditto all as above item No 2 but for AC plant of capacity 28 TR complete all as specified & directed by the Engr-in-charge.
Supply and charging R-22 gas complete all as specified & directed by the Engr-in-charge.
Supply and charging R-407C gas complete all as specified & directed by the Engr-in-charge.
M&L for descaling of shell & tube type condensers of central AC plant of capacity14TR with the help of descaling chemicals and nylon wire brush complete all as specified & as directed by Engineer-in-Charge.
Ditto all as above item No 8 but for central AC plant of capacity 28TR complete all as specified & as directed by Engineer-in-Charge.
Ditto all as above item No 8 but for central AC plant of capacity 20 TR complete all as specified & as directed by Engineer-in-Charge.
Ditto all as above item No 8 but for central AC plant of capacity 8.5TR complete all as specified & as directed by Engineer-in-Charge.
M&L for descaling air cooled type condensers of central AC plant of capacity 5.5TR with cleaning acid by forced feed method to remove the dust particles formed on the coil and fins complete all as specified & as directed by Engineer-in-Charge.
M&L for descaling air cooled type condensers of central AC plant of capacity 8.5TR with cleaning acid by forced feed method to remove the dust particles formed on the coil and fins complete all as specified & as directed by Engineer-in-Charge.
M&L for descaling of shell & tube type chiller of central AC plant of capacity 28TR with the help of descaling chemicals and nylon wire brush complete all as specified & as directed by Engineer-in-Charge.
M&L for Cleaning of evaporator coil of central AC plant of capacity 5.5TR with dilute HCL by forced feed method to remove the dust particles formed on the coil and fins ,cleaning of liquid lines, strainer, expansion valve complete all as directed by Engineer-in-Charge.
Ditto as item No 15 here in before but for central AC plant of capacity 8.5TR complete all as directed by Engineer-in-Charge.
Ditto as item No 15 here in before but for central AC plant of capacity 11TR complete all as directed by Engineer-in-Charge.
Ditto as item No 15 here in before but for central AC plant of capacity 14TR complete all as directed by Engineer-in-Charge.
Ditto as item No 15 here in before but for central AC plant of capacity 20TR complete all as directed by Engineer-in-Charge.
Ditto as item No 15 here in before but for central AC plant of capacity 28TR complete all as directed by Engineer-in-Charge.
M&L for detaching compressors, condensers, cooling coil,refrigerant lines of central AC plant of capacity 5.5TR & Leak testing with nitrogen (N2) pressure gas after evacuating of the existing gas from the system into empty cylinder, rectifying leakages including cutting welding brazing etc , refixing all detached parts with necessary O rings, washers, gaskets etc as required, flushing out the Nitrogen gas , vaccumising & recharging the taken out refrigerant gas complete all as directed by Engr-in Charge. Note: The quoted rate shall deemed to include for the cost of nitrogen (N2) pressure gas required for testing the leakage.
Ditto all as above item No 21 but for central AC plant of capacity 8.5TR complete all as directed by Engr-in Charge.
Ditto all as above item No 21 but for central AC plant of capacity 11TR complete all as directed by Engr-in Charge.
Ditto all as above item No 21 but for central AC plant of capacity14TR complete all as directed by Engr-in Charge.
Ditto all as item No 21 here in before but for central AC plant of capacity 20TR complete all as directed by Engr-in Charge.
Ditto all as item No 21 here in before but for central AC plant of capacity 28TR complete all as directed by Engr-in Charge.
M&L for taking out burned winding of 1HP blower motor out door and rewinding with new winding as per existing specification complete all as specified & directed by the Engr-in-charge.
Ditto all as above item No 27 but for 2HP blower motor complete all as specified & directed by the Engr-in-charge.
Ditto all as above item No 27 but for 3HP blower motor complete all as specified & directed by the Engr-in-charge.
Ditto all as above item No 27 but for 5HP blower motor complete all as specified & directed by the Engr-in-charge.
Ditto all as above item No 27 but for 10HP blower motor complete all as specified & directed by the Engr-in-charge.
Ditto all as item No 27 here in before but for 25HP blower motor complete all as specified & directed by the Engr-in-charge.
S&F V belt of size A-28 complete all as specified & directed by the Engr-in-charge. Make
S&F V belt of size B-63 complete all as specified & directed by the Engr-in-charge.
S&F V belt of size B-65 complete all as specified & directed by the Engr-in-charge.
S&F V belt of size B-79 complete all as specified & directed by the Engr-in-charge
S&F in repair Micro filter for AC plant of capacity 5.5TR to 28TR complete all as specified & directed by the Engr-in-charge.
S&F in repair Air filter for AC plant of capacity 5.5TR to 28TR complete all as specified & directed by the Engr-in-charge.
S&F in repair High pressure gauge 0-300 Psi complete all as specified & directed by the Engr-in-charge.
S&F in repair Low pressure gauge 0-150 Psi complete all as specified & directed by the Engr-in-charge.
S&F in repair Pressure gauge 0-100 kg/cm2 suitable for condenser water pipe line complete all as specified & directed by the Engr-in-charge.
S&F canvas cloth in between AHU and cold air duct of AC plant after removing the unserviceable cloth complete all as specified and as directed by Engineer-in-Charge.
Taking out defective high pressure/low pressure and oil pressure control switches including wiring, copper tubing complete and fixing of new high pressure/low pressure and oil pressure control switches including wiring,copper tubing of the existing length complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Solenoid valve assembly operating on 230 volts AC supply with & including replacing defective wiring,connected minor items complete all as specified and as directed by Engineer-in-Charge.
S&F in repair CI/GM suction service valve of any size and shape of reciprocating compressor and providing gasket, bolts, nuts of required size complete all as specified and as directed by Engr-in-Charge.
S&F in repair liquid line strainer of brass wire mesh suitable for Voltas/Bluestar AC with & including necessary sealing gasket/neoprene gasket/ring complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Liquid line Drier suitable for Voltas/Bluestar AC with & including necessary sealing gasket/neoprene gasket/ring complete all as specified and as directed by Engineer-in-Charge.
Supply and Charging Lubricating Oil for scroll type compressor with refrigerant R407 Mineral oil 160P complete all as specified and as directed by Engineer-in-Charge.
Supply and Charging Lubricating Oil for scroll type compressor with refrigerant R22 Mineral oil 160P complete all as specified and as directed by Engineer-in-Charge.
Supply and Charging Lubricating Oil for bearing, blower motor and outdoor motor complete all as specified and as directed by Engineer-in-Charge.
Supply and Charging dehydrated and wax free freesol-68 Servo lubricating oil in the sealed barrel complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Microprocessor with & including display,relay circuit, sensors & display cable for Package units of capacity 5.5 TR to 11 TR complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Microprocessor with & including display,relay circuit, sensors & display cable for central plants of capacity 14 TR to 28 TR complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 25 A capacity contactor 230 V complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 32 A capacity contactor 230 V complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 40 A capacity contactor 230 V complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 50 A capacity contactor 230 V complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 60 A capacity contactor 415 V complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 80 A capacity contactor 230 V complete all as specified and as directed by Engineer-in-Charge.
Taking out the blower motor shaft from the AC plant of capacity 5.5 TR to 28 TR , welding and grinding on Lathe to make suitable alignment with bearing and refixing complete all as directed by Engineer-in-Charge.
S&F in repair Runner of Blower drum for package unit of AC plant of capacity 5.5 TR to 11TR complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Fan blade suitable for air cooled condensor of AC plant of capacity 5.5 TR complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Fan blade suitable for air cooled condensor of AC plant of capacity 8.5 TR complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Timer of AC plant of capacity 5.5 TR to 28 TR complete all as specified and as directed by Engineer-in-Charge.
S&F Bearing of blower motor suitable for package units of AC plant of capacity 5.5 TR to 28 TR complete all as specified and as directed by Engineer-in-Charge.
S&F Connector 36 to 40 A, 440 Volt TP & TPN complete all as specified and as directed by Engineer-in-Charge.
S&F in repair MCB TP 6-32 Amps, 415 Volts, 10KA, ‘C’ series complete all as specified & as directed.
S&F in repair MCB TP 40 Amps, 415 Volts, 10KA, ‘C’ series complete all as specified & as directed.
S&F in repair MCB TP 63 Amps, 240 Volts, 10KA, ‘C’ series complete all as specified & as directed.
S&F in repair MCCB TP 25 - 100 Amps, 240 Volts, 16KA, ‘C’ series complete all as specified & as directed.
S&F in repair up to 160 Amps MCCB adjustable type, 4 Pole of breaking capacity 36KA complete all as specified and directed by Engr-in-Charge.
S&F in repair 200Amps MCCB adjustable type, 4 Pole of breaking capacity 36KA complete all as specified and directed by Engr-in-Charge.
S&F in repair 350Amps MCCB adjustable type, 4 Pole of breaking capacity 36KA complete all as specified and directed by Engr-in-Charge.
S&F in repair SMPS of central AC plant of capacity 14 TR to 28 TR complete all as specified and directed by Engr-in-Charge.
M &L for taking out the damaged insulation portion of existing outside duct, cleaning the duct, applying two coats of CPRX compound to cleaned portion of duct, applying one coat of bitumen paint, fixing of 50 mm thick glass wool of density 48 Kg and sealing it with hassion cloth. Providing 15 mm thick chicken wire mesh over the hassion cloth, rendering 15 mm thick in CM 1:4 ,applying two coats of cement base paint of existing colour over a coat of white wash and making good the disturbed portions complete all as specified and directed by the Eng-in-charge.
Repairing of all parts of AC Plants of any capacity,rectifying oil leakages ,water leakages, gas leakages ,valve blockages including replacement of unserviceable parts complete all as directed by Engineer -in-Charge. Note: -(i) The quoted rate shall be deemed to include for the cost of minor parts such as wiring,nut, bolts & washers required. (ii) Unserviceable parts shall be measured and paid seperately under relevant items mentioned in the Schedule.
S&F in repair Voltmeters digital type 0 to 500 Volt AC +/- 0.1 accuracy ,3 phase, 415 V complete all as specified and as directed.
S&F in repair Ammeters digital type 500A, +1.0 accuracy, 3 phase, 415 V direct type complete all as specified and as directed.
S&F in repair condensor motor suitable upto 0.5 HP 3 phase 415 V complete all as specified and as directed.
S&F in repair condensor motor suitable upto 1 HP 3 phase 415 V complete all as specified and as directed.
S&F in repair condensor motor suitable upto 2 HP 3 phase 415 V complete all as specified and as directed.
M&L wiring single core FR PVC insulated unsheathed cable, 1100 volts, grade having stranded copper conductor of 10 sqmm nominal cross sectional area after taking out old unserviceable wiring complete all as specified and as directed. Note: - The quoted rate shall be deemed to include for the cost of epoxy/PVC connection and copper terminal lugs as required.
Supply and fix stop valves 20 mm cost copper alloy, screwed down high pressure with crunch or butterfly handle screwed both ends for iron pipe or for unions and fixed including removal of old one.
S/F ball brass valves high pressure, with polythelne float and fly nut complete screwed for iron pipe of size 20 mm complete all as specified and as directed
S&F Copper refrigerent piping size 5/8" suitable for cooling appliances complete all as specified and as directed .
S&F Copper refrigerent piping size 3/8" suitable for cooling appliances complete all as specified and as directed.
M&L for matfinish 2 coated synthetic enamal Asian/Burger paint anti rust /anti crossive for suction / discharge pipe of AC plant and panel board etc in red / yellow/ blue /half white complete all as specified and dierectedby the Engineer -in-charge.
Supply & installation in repair of 14 TR ( combination of 2 Nos of compressor) scroll danfoss compressor and replacement of the same (Model:- SM185, Make: Voltas) by brazing activity, pressure testing and vaccumising. Charging the system with fresh refrigerent R-22 and recommissioning of the same all as specified and directed by Engineer-in-charge. Note:- The refrigerant gas R-22 shall be measured under the item supply & Charging.
Supply & installation in repair of 14 TR Shell & Tube type condensor suitable for Voltas Centralised AC plant (suitable for compressor model:- SM185, Make: Danfoss/Emersion by brazing activity, pressure testing and vaccumising. Charging the system with fresh refrigerent R-22 and recommissioning of the same all as specified and directed by Engineer-in-charge. Note:- The refrigerant gas R-22 shall be measured under the item supply & Charging.
M&L for Return air duct one number rectangular type from main rectangular type from main rectangular air duct up to the level of new ceiling board, appriximately 100 cm x 75 cm x 150 cm long (Approx PGI Sheet 5 Sqmtr) including necessary fabrication jointing, hanging, fixing and making leak proof. Approximate requirement of PGI sheet 0.71 mm thick all as specified and directed by Engineer-in-charge.
Supply & installation in repair of 5.5 TR ( combination of 2 Nos of compressor) scroll danfoss compressor and replacement of the same Make: Danfoss/Emersions) by brazing activity, pressure testing and vaccumising. Charging the system with fresh refrigerent R-407 and recommissioning of the same all as specified and directed by Engineer-in-charge.
Supply & installation in repair of 8.5 TR ( combination of 2 Nos of compressor) scroll danfoss compressor and replacement of the same , Make: Danfoss/Emersion) by brazing activity, pressure testing and vaccumising. Charging the system with fresh refrigerent R-22 and recommissioning of the same all as specified and directed by Engineer-in-charge. Note:- The refrigerant gas R-22 shall be measured under the item supply & Charging.
S&F blower motor runner shaft from the AC plant of capacity 5.5 TR to 14 TR complete all as directed by Engineer-in-Charge.
M&L for cleaning of cooling tower of central type AC plant of cap 8.5 TR to 28 TR, removal of water tray, pipe line and cleaning of cooling tower fins by using brush.omplete all as directed by Engineer-in-Charge.
Repair/Servicing of AC control Panel of capacity 5.5 TR to 28 TR and rewiring of the defected wiring of panel by proper connection using thimble, connector and replacement of unserviceable accessories refixing the all items complete all as directed by Engineer-in-Charge. (Note :- (i) The quoted rate shall be deemed to include for the cost of minor parts required for making the panel fully functional.
S&F for high/low pressure valve of size 3/8,5/8. complete all as directed by Engineer-in-Charge.
S&F CI/GI water line inlet/outlet valve of size up to 80mm.complete all as directed by Engineer-in-Charge.
S&F Thermal relay 15 Amp to 32 Amps as per sample complete all as directed by Engineer-in-Charge.
M&L for taking down Condensor pump of size 2 HP to 10 HP for repairing at civil work shop and checking of pump,bearing ,shaft, discharge nozzle, impeller oiling/greasing and testing of pump fully serviceable.complete all as directed by Engineer-in-Charge.
S&F LP/HP Switch for compressor for 5.5 TR to 28 TR AC plants complete all as directed by Engineer-in-Charge.
S&F Nitrile Rubber for insulation of copper pipe of size 1/3/8 complete all as directed by Engineer-in-Charge.
S&F Nitrile Rubber for insulation of copper pipe of size 5/8 complete all as directed by Engineer-in-Charge.
S&F Copper pipe of size1/3/8 with elbow and sockets.complete all as directed by Engineer-in-Charge.
S&F Copper pipe of size 5/8 with elbow and sockets. complete all as directed by Engineer-in-Charge.
M&L for modification/alteration of Evaporator coil by new design of AHU coil, cutting, welding, jointing work, fixing separate expansion valve for each compressor and separate copper pipe line for each compressor to evaporator coil including all connected accessories at Avonic lab AC plant” complete all as directed by Engineer-in-Charge.
SENCO
Neha Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .