Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹101.8 Cr |
Tender Value
₹102.8 Cr
EMD Value
₹1.1 Cr
Closing Date
1 Jun 2026, 5:00 pmClosed
Vipul Kumar Nandan
EE PURNEA
NEAR FOARD COMPANY CHOWK, NEAR PANTI TANKI , PURNEA
DAYASHANKAR PRASAD
CHIEF ENGINEER (DESIGN)
Part I: Fixed Operation of ward level piped water supply schemes (Quality affected/NQ affected) by deploying pump operators and payment of electricity charges and Part II: Variable Comprehensive maintenance of Ward level water supply schemes (Quality affected/NQ affected), i/c the cost of chemicals, overhauling of filter media and related apputenances, cleaning of ESR and campus, maintenance viz. cleaning painting of pump house, boundary wall, repair of leakages in districbuition line, repair and provision of new FHTCs, repair amd maintenance of pumps and other electromechanical components etc. all complete as per the directions of Engineer-in-charge. in Blocks: Purnea East, Kasba, Jalalgarh Srinagar, Dagarua Baisi, Amour and Baisa No. of schemes: PWS:-4 WLS(Quality):-951
130342
NIT No-02/O&M-PWS-WLS-PUR-PHED-2026-27 GR No-01
Open Tender
CIVIL
Purnia
• Contractor registered in appropriate class with Central Government/ State Government or their undertakings, any PSU in requisite class, or an agency of international or national repute may participate in the tender but registration with the Public Health Engineering Department, Bihar in requisite class will be essential after issue of LOA and before signing the agreement
• PAN Card
• Name of Bidder.
• Email ID and Mobile no. for communication.
• BID SECURITY
• LAST 5 YEARS ANNUAL TURN OVER
• EXPERIENCE Of SIMILAR NATURE Of W0RKS
• QUANTITY OF WORK OF SIMILAR NATURE EXECUTED DURING LAST 5 YEARS)
• BALANCE VALUE OF ON GOING WORKS
• EXISTING COMMITMENTS
• BANKER'S CERTIFICATE FOR ACCESS OF FINACIAL RESOURCES
• AFFIDAVIT
• LITIGATION HISTORY
• PLANT and MACHINARIES
• KEY PERSONNEL
• Power of Attoney
• All Terms and Conditions as per NIT-10-PUR/O&M-PHED-2025-26
• All Terms and Conditions as per Bid Document
• Bidder should not have pending electricity dues.
• Documents in original duly Signed as in section 3, 5, 6.
• Technical details such as treatment technology, operation & maintenance, life of plant, consumables if required, performance certificate etc.
CIVIL
PERCENTAGE
L1
1
25 documents required · 25 mandatory
₹10,000
Processing Fee: 5900
₹1.1 Cr
Office of Executive Engineer of P.H Division Purnea Near Ford Company Chowk Panitanki Purnea
19 Sept 2026
1 May 2026
1 Jun 2026
1 May 2026
1 Jun 2026
1 May 2026
4 May 2026
TECHNICAL BID SHEET
TENDER NIT No –02/O&M-PWS-WLS-PUR-PHED-2026-27
Name of Work Name of Work- Comprehensive operation and maintenance, routine repairs and Special repairs of Rural Piped Water Supply Scheme (PWS),Ward level Piped Water Supply Schemes in quality affected wards (WLS_Quality)Ward level Piped Water Supply Schemes in quality affected wards based on item rates; constructed by the Public Health Engineering Department including payment to the pump operators, electricity bill for five years BLOCKS: Purnea East, Kasba, Jalalgarh Srinagar, Dagarua Baisi, Amour and Baisa OF Purnea DISTRICT Under P.H.Division Purnea Cost of Work as per BOQ(Rs in Lakhs) 0.80000 Time of Completion in months 60 ALL COLOURED CELL TO BE FILLED ACCORDINGLY
Sactioned Amount As per Technical Approval Date of Tender 27.04.2026
Sl No. Items Requirement Requirement Cl. No.
Name of the Contractor
Address of the Contractor
1 Bid Validity Bids shall remain valid for a period not less than 180 days after the deadline date. A Bid valid for a shorter period shall be rejected by the Employer as non-responsive 180 Days 15.1 Page/21 Bid validity periods In days
2 Bid Security (A) Indian post office term deposit 1 year/2year/3year; National saving Certificate; Kishan Vikash Patra duly endorsed by the Competent Postal authority in Bihar. 16.1 Page-21 Amount To be entered (Rs in Lakhs)
(B) Fixed deposit receipt of a Schedule bank, Fixed deposit receipt should be Valid for six months after last date of receipt of tender and shall be pledged in favour of the department Amount To be entered (Rs in Lakhs)
(C ) 5 year National Development bond/State development loan certificate. Amount To be entered (Rs in Lakhs)
(D) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given (If issued from any bank outside state will be converted to any bank within the state before executing the agreement. Amount To be entered (Rs in Lakhs)
Bid Security Amount - (Rs. In Lakhs) 113 Bid Security Amount - Rs.
3 (i) Legal Status of Bidder. 4.3(a) Page-11
(ii) Place of Registration.
(iii) Principal place of Business
(iv) Power of attorney of signatory Bid Attached or Not 4.2(iv) Page-11
4 Total value of civil engineering construction work performed in last five years. 1. Annual Financial Turn Over in any one year during the the last five years to be not less than 50% of the estimated cost of works under the contract (Rs in Lakhs) 4.5A (a) Page-29
2020-21 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.47
2021-22 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.36
2022-23 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.26
2023-2024 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.17
2024-2025 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.08
5A Work Experience of Similar nature Satisfactorily completed as a prime contractor (or as a nominated sub contractor, where the sub contract involved the execution of all main items of the work described in the bid document, provided further that all other qualification criteria are satisfied) at least one similar work of value not less than the amount specified in the Appendix ( Not less than 10% (Ten percent) of the estimated value of contract. 4.5A (b) Page -29 Amount To be entered (Rs in Lakhs)
5B Work Experience of Similar nature Satisfactorily completed water supply schemes (Pipe water Supply scheme) at least one work of value not less than 10% (Ten percent) of the estimated cost of work for which the bid has been invited. 4.5A (b) Page -29 Amount To be entered (Rs in Lakhs)
5C Work Experience of any Civil work any one year during last five years Satisfactorily completed any type of Civil Engineering works of value not less than 25% (Twenty Five Percent) of the estimated cost of at least one work for which the bid has been invited during last five years. 4.5A (b) Page -29 Amount To be entered (Rs in Lakhs)
6 Executed the minimum quantities of work as indicated
Items Unit Quantity 4.5A(c) Page-16
Maintenance of water supply schemes in water quality affected areas. 5 YEARS 2.5YEARS 0.5 Value to be entered in unit nos
Value to be entered in unit nos
Value to be entered in unit meter
Value to be entered in unit nos
Value to be entered in unit nos
Value to be entered in unit nos
PSC/ RCC cum 0 Value to be entered in unit cum
Bidding Capacity: More than the total Bid value of present work = A*N*3-B=Rs. ____.Where A = Maxm. Value of work executed in any one yr during last 5 yrs. N= Nos of years for completion of works. B=Value of existing commitments & ongoing works to be completed in period 4.7 Page- 17
7 (a) Existing commitments and ongoing works 1.4 A Page - 35 Amount To be entered (Rs in Lakhs)
(b) Work for which Bid already submitted 1.4 BPage - 35 Amount To be entered (Rs in Lakhs)
8 Availability of key items of Contractor's Equipment Type of Equipment/Maximum age No. Required Nos. Max. Age 4.5(B) (a) Page- 31 Nos./ Max. Age
Concrete Mixer 3 5
Rotary Drilling/ Reverse Rotary/ DTH Rig Machine 2 10
Truck / Tractor with trailer 2 5
Hydraulic Excavator 2 5
9 Key Personnel Personnel/Qualification/Contract Package Size (work upto Rs. 30 Crore) 4.5(B) (b) Page-31 Name of the Personnel and Experince in years
Project Manager/ B.E. Civil + 10 Years Experience (5 years of PHE Works) 1
Site Engineer / B.E. Civil + 7 Years Experience (3 years of PHE works) 3
Site superviser / B.E. Civil or Mech. + 05 yrs experiance or Diploma in Civil + 07 Years Experience 12
Surveyor / B.E. Civil + 03 Years Exp. Or Dip. Civil + 05 years Exp. 1
10 Evidence of accesses to Financial Resources Evidence of access to or availability of creadit facilities (10% of estimated cost), certified by bankers (Not more than 3 months old). (Rs in Lakhs). 4.2 (i) page 14 & 39 Amount To be entered (Rs in Lakhs)
11 Proposed methodology and programme of construction. Justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion as per milestones. (Attached or not) page 37
12 Litigation History Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) page 38
13 Affidavit Regarding statements made in the required attachments are true and correct. page 40
14 Undertaking Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract. page 41
17 Character Certificate
18 Time of Completion 60 MONTHS To be entered in months
Check List for Submission Of Tender
Evaluation will be done as per the information provided in the document attached with tender. Bidder may disqualified, if documents are not attached properly.
Name of the Bidder
Sl. No. Checklist Items (Attach Documents in Edit Attachment Folder) Document attached
1 Bid Security in the form specified
2 Registration Certificate of Firm
5 Constitution or legal status of Bidder
6 Power of attorney of signatory of Bid, if applicable
7 Annual Turnover in last Five year, as per Cl. 4.5A(a)
8 Work Experience of Similar Nature, as per Cl. 4.5A(b)
9 Quantities of Work executed, as per Cl. 4.5A(c)
10 Bid Capacity as on the date of this bid
11 Existing commitments and ongoing works
12 Work for which Bid already submitted
13 Availability of key Equipment
14 Availability of key Personnel
15 Availability of Credit Facility
16 Undertaking regarding Minimum investment capacity
17 Proposed work method and schedule
18 Litigation history
19 Affidavit regarding Debar/Blacklisting & Statements
20 Undertaking regarding Bid validity
21 Character Certificate
22 Filled Technical Bid Sheet
23 Any other Documents required as per NIT/ Standard Bidding Documents Required
IF YOU HAVE NOT BEEN DEBARED WRITE "NOT APPLICABLE" IN YOUR LETTER HEAD SCAN AND UPLOAD IN THE IN NOC FOR DEBAR LINK
Note:-Attachment should be self attested and should be attached as per above instruction, otherwise it may be rejected.
I, the undersigned, do hereby certify that all the statements made in the required attachments are true and correct.
Signature & Seal of the Bidder
TECHNICAL BID SHEET
TENDER NIT No –02/O&M-PWS-WLS-PUR-PHED-2026-27
Name of Work Name of Work- Comprehensive operation and maintenance, routine repairs and Special repairs of Rural Piped Water Supply Scheme (PWS),Ward level Piped Water Supply Schemes in quality affected wards (WLS_Quality)Ward level Piped Water Supply Schemes in quality affected wards based on item rates; constructed by the Public Health Engineering Department including payment to the pump operators, electricity bill for five years BLOCKS: Purnea East, Kasba, Jalalgarh Srinagar, Dagarua Baisi, Amour and Baisa OF Purnea DISTRICT Under P.H.Division Purnea Cost of Work as per BOQ(Rs in Lakhs) 0.80000 Time of Completion in months 60 ALL COLOURED CELL TO BE FILLED ACCORDINGLY
Sactioned Amount As per Technical Approval Date of Tender 27.04.2026
Sl No. Items Requirement Requirement Cl. No.
Name of the Contractor
Address of the Contractor
1 Bid Validity Bids shall remain valid for a period not less than 180 days after the deadline date. A Bid valid for a shorter period shall be rejected by the Employer as non-responsive 180 Days 15.1 Page/21 Bid validity periods In days
2 Bid Security (A) Indian post office term deposit 1 year/2year/3year; National saving Certificate; Kishan Vikash Patra duly endorsed by the Competent Postal authority in Bihar. 16.1 Page-21 Amount To be entered (Rs in Lakhs)
(B) Fixed deposit receipt of a Schedule bank, Fixed deposit receipt should be Valid for six months after last date of receipt of tender and shall be pledged in favour of the department Amount To be entered (Rs in Lakhs)
(C ) 5 year National Development bond/State development loan certificate. Amount To be entered (Rs in Lakhs)
(D) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given (If issued from any bank outside state will be converted to any bank within the state before executing the agreement. Amount To be entered (Rs in Lakhs)
Bid Security Amount - (Rs. In Lakhs) 113 Bid Security Amount - Rs.
3 (i) Legal Status of Bidder. 4.3(a) Page-11
(ii) Place of Registration.
(iii) Principal place of Business
(iv) Power of attorney of signatory Bid Attached or Not 4.2(iv) Page-11
4 Total value of civil engineering construction work performed in last five years. 1. Annual Financial Turn Over in any one year during the the last five years to be not less than 50% of the estimated cost of works under the contract (Rs in Lakhs) 4.5A (a) Page-29
2020-21 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.47
2021-22 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.36
2022-23 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.26
2023-2024 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.17
2024-2025 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.08
5A Work Experience of Similar nature Satisfactorily completed as a prime contractor (or as a nominated sub contractor, where the sub contract involved the execution of all main items of the work described in the bid document, provided further that all other qualification criteria are satisfied) at least one similar work of value not less than the amount specified in the Appendix ( Not less than 10% (Ten percent) of the estimated value of contract. 4.5A (b) Page -29 Amount To be entered (Rs in Lakhs)
5B Work Experience of Similar nature Satisfactorily completed water supply schemes (Pipe water Supply scheme) at least one work of value not less than 10% (Ten percent) of the estimated cost of work for which the bid has been invited. 4.5A (b) Page -29 Amount To be entered (Rs in Lakhs)
5C Work Experience of any Civil work any one year during last five years Satisfactorily completed any type of Civil Engineering works of value not less than 25% (Twenty Five Percent) of the estimated cost of at least one work for which the bid has been invited during last five years. 4.5A (b) Page -29 Amount To be entered (Rs in Lakhs)
6 Executed the minimum quantities of work as indicated
Items Unit Quantity 4.5A(c) Page-16
Maintenance of water supply schemes in water quality affected areas. 5 YEARS 2.5YEARS 0.5 Value to be entered in unit nos
Value to be entered in unit nos
Value to be entered in unit meter
Value to be entered in unit nos
Value to be entered in unit nos
Value to be entered in unit nos
PSC/ RCC cum 0 Value to be entered in unit cum
Bidding Capacity: More than the total Bid value of present work = A*N*3-B=Rs. ____.Where A = Maxm. Value of work executed in any one yr during last 5 yrs. N= Nos of years for completion of works. B=Value of existing commitments & ongoing works to be completed in period 4.7 Page- 17
7 (a) Existing commitments and ongoing works 1.4 A Page - 35 Amount To be entered (Rs in Lakhs)
(b) Work for which Bid already submitted 1.4 BPage - 35 Amount To be entered (Rs in Lakhs)
8 Availability of key items of Contractor's Equipment Type of Equipment/Maximum age No. Required Nos. Max. Age 4.5(B) (a) Page- 31 Nos./ Max. Age
Concrete Mixer 3 5
Rotary Drilling/ Reverse Rotary/ DTH Rig Machine 2 10
Truck / Tractor with trailer 2 5
Hydraulic Excavator 2 5
9 Key Personnel Personnel/Qualification/Contract Package Size (work upto Rs. 30 Crore) 4.5(B) (b) Page-31 Name of the Personnel and Experince in years
Project Manager/ B.E. Civil + 10 Years Experience (5 years of PHE Works) 1
Site Engineer / B.E. Civil + 7 Years Experience (3 years of PHE works) 3
Site superviser / B.E. Civil or Mech. + 05 yrs experiance or Diploma in Civil + 07 Years Experience 12
Surveyor / B.E. Civil + 03 Years Exp. Or Dip. Civil + 05 years Exp. 1
10 Evidence of accesses to Financial Resources Evidence of access to or availability of creadit facilities (10% of estimated cost), certified by bankers (Not more than 3 months old). (Rs in Lakhs). 4.2 (i) page 14 & 39 Amount To be entered (Rs in Lakhs)
11 Proposed methodology and programme of construction. Justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion as per milestones. (Attached or not) page 37
12 Litigation History Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) page 38
13 Affidavit Regarding statements made in the required attachments are true and correct. page 40
14 Undertaking Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract. page 41
17 Character Certificate
18 Time of Completion 60 MONTHS To be entered in months
Check List for Submission Of Tender
Evaluation will be done as per the information provided in the document attached with tender. Bidder may disqualified, if documents are not attached properly.
Name of the Bidder
Sl. No. Checklist Items (Attach Documents in Edit Attachment Folder) Document attached
1 Bid Security in the form specified
2 Registration Certificate of Firm
5 Constitution or legal status of Bidder
6 Power of attorney of signatory of Bid, if applicable
7 Annual Turnover in last Five year, as per Cl. 4.5A(a)
8 Work Experience of Similar Nature, as per Cl. 4.5A(b)
9 Quantities of Work executed, as per Cl. 4.5A(c)
10 Bid Capacity as on the date of this bid
11 Existing commitments and ongoing works
12 Work for which Bid already submitted
13 Availability of key Equipment
14 Availability of key Personnel
15 Availability of Credit Facility
16 Undertaking regarding Minimum investment capacity
17 Proposed work method and schedule
18 Litigation history
19 Affidavit regarding Debar/Blacklisting & Statements
20 Undertaking regarding Bid validity
21 Character Certificate
22 Filled Technical Bid Sheet
23 Any other Documents required as per NIT/ Standard Bidding Documents Required
IF YOU HAVE NOT BEEN DEBARED WRITE "NOT APPLICABLE" IN YOUR LETTER HEAD SCAN AND UPLOAD IN THE IN NOC FOR DEBAR LINK
Note:-Attachment should be self attested and should be attached as per above instruction, otherwise it may be rejected.
I, the undersigned, do hereby certify that all the statements made in the required attachments are true and correct.
Signature & Seal of the Bidder
P. H. DIVISION, PURNEA
FINANCIAL BID SHEET
NIT No –02/O&M-PWS-WLS-PUR-PHED-2026-27
Name of Work-Comprehensive operation and maintenance routine repairs and Special repair of i) Rural Piped Water Supply Scheme (PWS). ii) Ward Level Piped Water Supply Schemes in quality affected wards (WLS-Quality) based on item rates: Constructed by the Public Health Engineering Department including payment to the pump operators, electricity bills for five Years. Water Supply Schemes under P.H.Division Purnea Part I: Fixed Operation of ward level piped water supply schemes (Quality affected/NQ affected) by deploying pump operators and payment of electricity charges and Part II: Variable Comprehensive maintenance of Ward level water supply schemes (Quality affected/NQ affected), i/c the cost of chemicals, overhauling of filter media and related apputenances, cleaning of ESR and campus, maintenance viz. cleaning painting of pump house, boundary wall, repair of leakages in districbuition line, repair and provision of new FHTCs, repair amd maintenance of pumps and other electromechanical components etc. all complete as per the directions of Engineer-in-charge. in Blocks: Purnea East, Kasba, Jalalgarh Srinagar, Dagarua Baisi, Amour and Baisa No. of schemes: PWS:-4 WLS(Quality):-951
Date of Tender :- 27.-.4-2026
Estimated Cost :- 10283.03950 lakh
Earnest Money :- 113.00 lakh
Duration of Maintenance Period 60 Months
Cost of BOQ :- 10000.00
SI NO. PARTICULARS No. of Scheme AMOUNT
1 Part I: Fixed Operation of ward level piped water supply schemes (Quality affected/NQ affected) by deploying pump operators and payment of electricity charges and Part II: Variable Comprehensive maintenance of Ward level water supply schemes (Quality affected/NQ affected), i/c the cost of chemicals, overhauling of filter media and related apputenances, cleaning of ESR and campus, maintenance viz. cleaning painting of pump house, boundary wall, repair of leakages in districbuition line, repair and provision of new FHTCs, repair amd maintenance of pumps and other electromechanical components etc. all complete as per the directions of Engineer-in-charge. in Blocks: Purnea East, Kasba, Jalalgarh Srinagar, Dagarua Baisi, Amour and Baisa No. of schemes: PWS:-4 WLS(Quality):-951 PWS:-04 WLS(Quality): 951 No. 1028303950.00
Total Amount 1028303950.000
(Rupees One Hundred Eight Crore Fourty Five Lakh Sixty Nine Thousand Three Hundred Sixty Only )
1 Estimated cost Rs. 1028303950.000 (A)
2 Cost of Govt. Material :- NIL NIL (B)
3 Name of the Contractor :-
4 Address of the Contractor :-
5 I/we offer in Figures……. in words………………… % (Percentage) High on the rate for the fixed cost (Part I) for operation of the schemes. IN FIG.
6 I/we offer in Figures……. in words………………… % (Percentage) High / Less on the rate for the variable cost (Part-II) for maintenance of the schemes. IN FIG.
7 Average rate quoted by the bidder 0.00
Note :- 1.) Bidders has to quote rate in Percentage High/Less only.
Note :- 2.) Items/ Quantity of Work will be decided by the department on day to day / priority basis during period of maintenance.
Note :- 3.) The quoted rate for the operation part I (fixed cost) i.e. the payment to the operators and the electricity bills, the quote shall not be negative.
Note :- 4.) The electricity bills shall be paid as per actual.
Note :- 5.) The entry in row 7 shall be considered for decision of financially lowest bid.
Executive Engineer, P.H.Division, Purnea
P. H. DIVISION, Purnea
List of Schemes for
Name of Work-Comprehensive operation and maintenance routine repairs and Special repair of i) Rural Piped Water Supply Scheme (PWS). ii) Ward Level Piped Water Supply Schemes in quality affected wards (WLS-Quality) based on item rates: Constructed by the Public Health Engineering Department including payment to the pump operators, electricity bills for five Years. Water Supply Schemes under P.H.Division Purnea
NIT No –02/O&M-PWS-WLS-PUR-PHED-2026-27
Sl. No. Division Scheme Name (WLS (Q)/PWS Block Panchayat Ward No.
1 Purnea (WLS (Q) Srinagar Khokha South 5A
2 Purnea (WLS (Q) Srinagar Khokha South 05B
3 Purnea (WLS (Q) Srinagar Khokha South 06
4 Purnea (WLS (Q) Srinagar Khokha South 07
5 Purnea (WLS (Q) Srinagar Khokha South 8A
6 Purnea (WLS (Q) Srinagar Khokha South 8B
7 Purnea (WLS (Q) Srinagar Khokha South 9
8 Purnea (WLS (Q) Srinagar Khokha South 10
9 Purnea (WLS (Q) Srinagar Khokha South 11
10 Purnea (WLS (Q) Srinagar Khokha South 1
11 Purnea (WLS (Q) Srinagar Khokha South 2
12 Purnea (WLS (Q) Srinagar Khokha South 3A
13 Purnea (WLS (Q) Srinagar Khokha South 3B
14 Purnea (WLS (Q) Srinagar Khokha South 4A
15 Purnea (WLS (Q) Srinagar Khokha South 4B
16 Purnea (WLS (Q) Srinagar Khokha South 12
17 Purnea (WLS (Q) Srinagar Khokha South 13
18 Purnea (WLS (Q) Srinagar Khokha South 14
19 Purnea (WLS (Q) Srinagar Khuti Dhunali 11
20 Purnea (WLS (Q) Srinagar Khuti Dhunali 12
21 Purnea (WLS (Q) Srinagar Khuti Dhunali 13
22 Purnea (WLS (Q) Srinagar Khuti Dhunali 1A
23 Purnea (WLS (Q) Srinagar Khuti Dhunali 1B
24 Purnea (WLS (Q) Srinagar Khuti Dhunali 1C
25 Purnea (WLS (Q) Srinagar Khuti Dhunali 2
26 Purnea (WLS (Q) Srinagar Khuti Dhunali 3
27 Purnea (WLS (Q) Srinagar Khuti Dhunali 4
28 Purnea (WLS (Q) Srinagar Khuti Dhunali 5A
29 Purnea (WLS (Q) Srinagar Khuti Dhunali 5B
30 Purnea (WLS (Q) Srinagar Khuti Dhunali 6
31 Purnea (WLS (Q) Srinagar Khuti Dhunali 7
32 Purnea (WLS (Q) Srinagar Khuti Dhunali 8A
33 Purnea (WLS (Q) Srinagar Khuti Dhunali 8B
34 Purnea (WLS (Q) Srinagar Chanka 1
35 Purnea (WLS (Q) Srinagar Chanka 2
36 Purnea (WLS (Q) Srinagar Chanka 3
37 Purnea (WLS (Q) Srinagar Chanka 4
38 Purnea (WLS (Q) Srinagar Chanka 5
39 Purnea (WLS (Q) Srinagar Chanka 6
40 Purnea (WLS (Q) Srinagar Chanka 7A
41 Purnea (WLS (Q) Srinagar Chanka 7B
42 Purnea (WLS (Q) Srinagar Chanka 8
43 Purnea (WLS (Q) Srinagar Chanka 9
44 Purnea (WLS (Q) Srinagar Chanka 10
45 Purnea (WLS (Q) Srinagar Chanka 11
46 Purnea (WLS (Q) Srinagar Chanka 12
47 Purnea (WLS (Q) Srinagar Chanka 13
48 Purnea (WLS (Q) Srinagar Jhunnikala 1
49 Purnea (WLS (Q) Srinagar Jhunnikala 2
50 Purnea (WLS (Q) Srinagar Jhunnikala 3
51 Purnea (WLS (Q) Srinagar Jhunnikala 4
52 Purnea (WLS (Q) Srinagar Jhunnikala 5
53 Purnea (WLS (Q) Srinagar Jhunnikala 6
54 Purnea (WLS (Q) Srinagar Jhunnikala 7
55 Purnea (WLS (Q) Srinagar Jhunnikala 8
56 Purnea (WLS (Q) Srinagar Jhunnikala 9
57 Purnea (WLS (Q) Srinagar Jhunnikala 10
58 Purnea (WLS (Q) Srinagar Jhunnikala 11
59 Purnea (WLS (Q) Srinagar Jhunnikala 12
60 Purnea (WLS (Q) Srinagar Jhunnikala 13
61 Purnea (WLS (Q) Srinagar Jhunnikala 14
62 Purnea (WLS (Q) Srinagar Jagaili 1A
63 Purnea (WLS (Q) Srinagar Jagaili 1B
64 Purnea (WLS (Q) Srinagar Jagaili 1C
65 Purnea (WLS (Q) Srinagar Jagaili 2A
66 Purnea (WLS (Q) Srinagar Jagaili 2A
67 Purnea (WLS (Q) Srinagar Jagaili 3
68 Purnea (WLS (Q) Srinagar Jagaili 4A
69 Purnea (WLS (Q) Srinagar Jagaili 4B
70 Purnea (WLS (Q) Srinagar Jagaili 5
71 Purnea (WLS (Q) Srinagar Jagaili 6A
72 Purnea (WLS (Q) Srinagar Jagaili 6B
73 Purnea (WLS (Q) Srinagar Jagaili 11B
74 Purnea (WLS (Q) Srinagar Jagaili 12A
75 Purnea (WLS (Q) Srinagar Jagaili 12B
76 Purnea (WLS (Q) Srinagar Khutti Hasaili 1
77 Purnea (WLS (Q) Srinagar Khutti Hasaili 2
78 Purnea (WLS (Q) Srinagar Khutti Hasaili 12
79 Purnea (WLS (Q) Srinagar Khutti Hasaili 3A
80 Purnea (WLS (Q) Srinagar Khutti Hasaili 3B
81 Purnea (WLS (Q) Srinagar Khutti Hasaili 10A
82 Purnea (WLS (Q) Srinagar Khutti Hasaili 10B
83 Purnea (WLS (Q) Srinagar Khutti Hasaili 4A
84 Purnea (WLS (Q) Srinagar Khutti Hasaili 4B
85 Purnea (WLS (Q) Srinagar Khutti Hasaili 5A
86 Purnea (WLS (Q) Srinagar Khutti Hasaili 5B
87 Purnea (WLS (Q) Srinagar Khutti Hasaili 6A
88 Purnea (WLS (Q) Srinagar Khutti Hasaili 6B
89 Purnea (WLS (Q) Srinagar Khutti Hasaili 7A
90 Purnea (WLS (Q) Srinagar Khutti Hasaili 7B
91 Purnea (WLS (Q) Srinagar Khutti Hasaili 8A
92 Purnea (WLS (Q) Srinagar Khutti Hasaili 8B
93 Purnea (WLS (Q) Srinagar Khutti Hasaili 9A
94 Purnea (WLS (Q) Srinagar Khutti Hasaili 9B
95 Purnea (WLS (Q) Srinagar Khutti Hasaili 11A
96 Purnea (WLS (Q) Srinagar Khutti Hasaili 11B
97 Purnea (WLS (Q) Srinagar Khutti Hasaili 13A
98 Purnea (WLS (Q) Srinagar Khutti Hasaili 13B
99 Purnea (WLS (Q) Srinagar Khutti Hasaili 14A
100 Purnea (WLS (Q) Srinagar Khutti Hasaili 14B
101 Purnea (WLS (Q) Srinagar Garhiya Balwa 4
102 Purnea (WLS (Q) Srinagar Garhiya Balwa 5
103 Purnea (WLS (Q) Srinagar Garhiya Balwa 6
104 Purnea (WLS (Q) Srinagar Garhiya Balwa 9
105 Purnea (WLS (Q) Srinagar Garhiya Balwa 11
106 Purnea (WLS (Q) Srinagar Garhiya Balwa 13
107 Purnea (WLS (Q) Srinagar Garhiya Balwa 7A
108 Purnea (WLS (Q) Srinagar Garhiya Balwa 7B
109 Purnea (WLS (Q) Srinagar Garhiya Balwa 8A
110 Purnea (WLS (Q) Srinagar Garhiya Balwa 8B
111 Purnea (WLS (Q) Kasba Baneli 3
112 Purnea (WLS (Q) Kasba Baneli 4
113 Purnea (WLS (Q) Kasba Baneli 5
114 Purnea (WLS (Q) Kasba Baneli 9
115 Purnea (WLS (Q) Kasba Baneli 10
116 Purnea (WLS (Q) Kasba Baneli 11
117 Purnea (WLS (Q) Kasba Baneli 12
118 Purnea (WLS (Q) Kasba Baneli 1A
119 Purnea (WLS (Q) Kasba Baneli 1B
120 Purnea (WLS (Q) Kasba Baneli 2
121 Purnea (WLS (Q) Kasba Baneli 6
122 Purnea (WLS (Q) Kasba Baneli 7
123 Purnea (WLS (Q) Kasba Baneli 8
124 Purnea (WLS (Q) Kasba Bhamra Lagan 7
125 Purnea (WLS (Q) Kasba Bhamra Lagan 8
126 Purnea (WLS (Q) Kasba Bhamra Lagan 9
127 Purnea (WLS (Q) Kasba Bhamra Lagan 10
128 Purnea (WLS (Q) Kasba Bhamra Lagan 11
129 Purnea (WLS (Q) Kasba Bhamra Lagan 1
130 Purnea (WLS (Q) Kasba Bhamra Lagan 2
131 Purnea (WLS (Q) Kasba Bhamra Lagan 3
132 Purnea (WLS (Q) Kasba Bhamra Lagan 4
133 Purnea (WLS (Q) Kasba Bhamra Lagan 5
134 Purnea (WLS (Q) Kasba Bhamra Lagan 6
135 Purnea (WLS (Q) Kasba Bochgoan 1
136 Purnea (WLS (Q) Kasba Bochgoan 2
137 Purnea (WLS (Q) Kasba Bochgoan 3
138 Purnea (WLS (Q) Kasba Bochgoan 4
139 Purnea (WLS (Q) Kasba Bochgoan 5
140 Purnea (WLS (Q) Kasba Bochgoan 6
141 Purnea (WLS (Q) Kasba Bochgoan 7A
142 Purnea (WLS (Q) Kasba Bochgoan 7B
143 Purnea (WLS (Q) Kasba Bochgoan 8A
144 Purnea (WLS (Q) Kasba Bochgoan 8B
145 Purnea (WLS (Q) Kasba Bochgoan 9
146 Purnea (WLS (Q) Kasba Bochgoan 11
147 Purnea (WLS (Q) Kasba Bochgoan 10A
148 Purnea (WLS (Q) Kasba Bochgoan 10B
149 Purnea (WLS (Q) Kasba Bochgoan 12A
150 Purnea (WLS (Q) Kasba Bochgoan 12B
151 Purnea (WLS (Q) Kasba Bochgoan 13
152 Purnea (WLS (Q) Kasba Bochgoan 14A
153 Purnea (WLS (Q) Kasba Bochgoan 14B
154 Purnea (WLS (Q) Kasba Ghordour 1
155 Purnea (WLS (Q) Kasba Ghordour 2
156 Purnea (WLS (Q) Kasba Ghordour 3
157 Purnea (WLS (Q) Kasba Ghordour 4A
158 Purnea (WLS (Q) Kasba Ghordour 4B
159 Purnea (WLS (Q) Kasba Ghordour 6
160 Purnea (WLS (Q) Kasba Ghordour 7
161 Purnea (WLS (Q) Kasba Ghordour 8
162 Purnea (WLS (Q) Kasba Ghordour 9
163 Purnea (WLS (Q) Kasba Ghordour 10
164 Purnea (WLS (Q) Kasba Ghordour 11
165 Purnea (WLS (Q) Kasba Ghordour 12
166 Purnea (WLS (Q) Kasba Kullakhas 1
167 Purnea (WLS (Q) Kasba Kullakhas 2A
168 Purnea (WLS (Q) Kasba Kullakhas 2B
169 Purnea (WLS (Q) Kasba Kullakhas 3A
170 Purnea (WLS (Q) Kasba Kullakhas 4A
171 Purnea (WLS (Q) Kasba Kullakhas 5
172 Purnea (WLS (Q) Kasba Kullakhas 6
173 Purnea (WLS (Q) Kasba Kullakhas 7
174 Purnea (WLS (Q) Kasba Kullakhas 8
175 Purnea (WLS (Q) Kasba Kullakhas 9
176 Purnea (WLS (Q) Kasba Kullakhas 10A
177 Purnea (WLS (Q) Kasba Kullakhas 10B
178 Purnea (WLS (Q) Kasba Kullakhas 11
179 Purnea (WLS (Q) Kasba Ghordour 5
180 Purnea (WLS (Q) Kasba Lakhana 1
181 Purnea (WLS (Q) Kasba Lakhana 2
182 Purnea (WLS (Q) Kasba Lakhana 3A
183 Purnea (WLS (Q) Kasba Lakhana 3B
184 Purnea (WLS (Q) Kasba Lakhana 4
185 Purnea (WLS (Q) Kasba Lakhana 5
186 Purnea (WLS (Q) Kasba Lakhana 6
187 Purnea (WLS (Q) Kasba Lakhana 11
188 Purnea (WLS (Q) Kasba Lakhana 12
189 Purnea (WLS (Q) Kasba Lakhana 13
190 Purnea (WLS (Q) Kasba Lakhana 14
191 Purnea (WLS (Q) Kasba Lakhana 15
192 Purnea (WLS (Q) Kasba Lakhana 7
193 Purnea (WLS (Q) Kasba Lakhana 8
194 Purnea (WLS (Q) Kasba Lakhana 9A
195 Purnea (WLS (Q) Kasba Lakhana 9B
196 Purnea (WLS (Q) Kasba Lakhana 10A
197 Purnea (WLS (Q) Kasba Lakhana 10B
198 Purnea (WLS (Q) Kasba Malhariya 1
199 Purnea (WLS (Q) Kasba Malhariya 2
200 Purnea (WLS (Q) Kasba Malhariya 3
201 Purnea (WLS (Q) Kasba Malhariya 4
202 Purnea (WLS (Q) Kasba Malhariya 5A
203 Purnea (WLS (Q) Kasba Malhariya 5B
204 Purnea (WLS (Q) Kasba Malhariya 6
205 Purnea (WLS (Q) Kasba Malhariya 7
206 Purnea (WLS (Q) Kasba Malhariya 8
207 Purnea (WLS (Q) Kasba Malhariya 9
208 Purnea (WLS (Q) Kasba Malhariya 10A
209 Purnea (WLS (Q) Kasba Malhariya 10B
210 Purnea (WLS (Q) Kasba Malhariya 11
211 Purnea (WLS (Q) Kasba Mohani 1A
212 Purnea (WLS (Q) Kasba Mohani 1B
213 Purnea (WLS (Q) Kasba Mohani 2A
214 Purnea (WLS (Q) Kasba Mohani 2B
215 Purnea (WLS (Q) Kasba Mohani 3A
216 Purnea (WLS (Q) Kasba Mohani 3B
217 Purnea (WLS (Q) Kasba Mohani 4A
218 Purnea (WLS (Q) Kasba Mohani 4B
219 Purnea (WLS (Q) Kasba Mohani 5
220 Purnea (WLS (Q) Kasba Mohani 6
221 Purnea (WLS (Q) Kasba Mohani 7
222 Purnea (WLS (Q) Kasba Mohani 8
223 Purnea (WLS (Q) Kasba Mohani 10B
224 Purnea (WLS (Q) Kasba Mohani 11A
225 Purnea (WLS (Q) Kasba Mohani 11B
226 Purnea (WLS (Q) Kasba Mohani 12
227 Purnea (WLS (Q) Kasba Mohani 13
228 Purnea (WLS (Q) Kasba Mohani 14A
229 Purnea (WLS (Q) Kasba Mohani 14B
230 Purnea (WLS (Q) Kasba Sadhubeli 6
231 Purnea (WLS (Q) Kasba Sadhubeli 7
232 Purnea (WLS (Q) Kasba Sadhubeli 8
233 Purnea (WLS (Q) Kasba Sadhubeli 9
234 Purnea (WLS (Q) Kasba Sadhubeli 1
235 Purnea (WLS (Q) Kasba Sadhubeli 3
236 Purnea (WLS (Q) Kasba Sadhubeli 4
237 Purnea (WLS (Q) Kasba Sadhubeli 5
238 Purnea (WLS (Q) Kasba Sanjheli 1
239 Purnea (WLS (Q) Kasba Sanjheli 2
240 Purnea (WLS (Q) Kasba Sanjheli 3
241 Purnea (WLS (Q) Kasba Sanjheli 4
242 Purnea (WLS (Q) Kasba Sanjheli 5
243 Purnea (WLS (Q) Kasba Sanjheli 6
244 Purnea (WLS (Q) Kasba Sanjheli 7
245 Purnea (WLS (Q) Kasba Sanjheli 8
246 Purnea (WLS (Q) Kasba Sanjheli 9
247 Purnea (WLS (Q) Kasba Sanjheli 10
248 Purnea (WLS (Q) Kasba Sanjheli 11A
249 Purnea (WLS (Q) Kasba Sanjheli 11B
250 Purnea (WLS (Q) Kasba Sanjheli 12
251 Purnea (WLS (Q) Kasba Sanjheli 13
252 Purnea (WLS (Q) Kasba Sanjheli 14
253 Purnea (WLS (Q) Kasba Sanjheli 15
254 Purnea (WLS (Q) Kasba Sanjheli 16
255 Purnea (WLS (Q) Kasba Shabdalpur 9
256 Purnea (WLS (Q) Kasba Shabdalpur 10
257 Purnea (WLS (Q) Kasba Shabdalpur 11
258 Purnea (WLS (Q) Kasba Shabdalpur 1
259 Purnea (WLS (Q) Kasba Shabdalpur 2
260 Purnea (WLS (Q) Kasba Shabdalpur 3
261 Purnea (WLS (Q) Kasba Shabdalpur 4
262 Purnea (WLS (Q) Kasba Shabdalpur 5
263 Purnea (WLS (Q) Jalalgarh Chak 10A
264 Purnea (WLS (Q) Jalalgarh Chak 10B
265 Purnea (WLS (Q) Jalalgarh Chak 12A
266 Purnea (WLS (Q) Jalalgarh Chak 12B
267 Purnea (WLS (Q) Jalalgarh Dansar 9
268 Purnea (WLS (Q) Jalalgarh Dimiya 1
269 Purnea (WLS (Q) Jalalgarh Dimiya 2
270 Purnea (WLS (Q) Jalalgarh Dimiya 3
271 Purnea (WLS (Q) Jalalgarh Dimiya 4
272 Purnea (WLS (Q) Jalalgarh Dimiya 5
273 Purnea (WLS (Q) Jalalgarh Dimiya 6
274 Purnea (WLS (Q) Jalalgarh Dimiya 7
275 Purnea (WLS (Q) Jalalgarh Dimiya 8
276 Purnea (WLS (Q) Jalalgarh Dimiya 9
277 Purnea (WLS (Q) Jalalgarh Dimiya 10
278 Purnea (WLS (Q) Jalalgarh Dimiya 11
279 Purnea (WLS (Q) Jalalgarh Dimiya 12
280 Purnea (WLS (Q) Jalalgarh Dimiya 13
281 Purnea (WLS (Q) Jalalgarh Dimiya 14
282 Purnea (WLS (Q) Jalalgarh Dimiya 15
283 Purnea (WLS (Q) Jalalgarh Dimiya 17
284 Purnea (WLS (Q) Jalalgarh Ekamba 2
285 Purnea (WLS (Q) Jalalgarh Hasibegampur 1
286 Purnea (WLS (Q) Jalalgarh Hasibegampur 2
287 Purnea (WLS (Q) Jalalgarh Hasibegampur 3
288 Purnea (WLS (Q) Jalalgarh Hasibegampur 4
289 Purnea (WLS (Q) Jalalgarh Hasibegampur 5
290 Purnea (WLS (Q) Jalalgarh Hasibegampur 6A
291 Purnea (WLS (Q) Jalalgarh Hasibegampur 6B
292 Purnea (WLS (Q) Jalalgarh Hasibegampur 7
293 Purnea (WLS (Q) Jalalgarh Hasibegampur 8
294 Purnea (WLS (Q) Jalalgarh Hasibegampur 9
295 Purnea (WLS (Q) Jalalgarh Hasibegampur 10
296 Purnea (WLS (Q) Jalalgarh Hasibegampur 11
297 Purnea (WLS (Q) Jalalgarh Hasibegampur 12
298 Purnea (WLS (Q) Jalalgarh Hasibegampur 13
299 Purnea (WLS (Q) Jalalgarh Hasibegampur 14
300 Purnea (WLS (Q) Jalalgarh Jalalgarh 1A
301 Purnea (WLS (Q) Jalalgarh Jalalgarh 1B
302 Purnea (WLS (Q) Jalalgarh Jalalgarh 2
303 Purnea (WLS (Q) Jalalgarh Jalalgarh 3A
304 Purnea (WLS (Q) Jalalgarh Jalalgarh 4A
305 Purnea (WLS (Q) Jalalgarh Jalalgarh 4B
306 Purnea (WLS (Q) Jalalgarh Jalalgarh 5
307 Purnea (WLS (Q) Jalalgarh Jalalgarh 6
308 Purnea (WLS (Q) Jalalgarh Jalalgarh 9A
309 Purnea (WLS (Q) Jalalgarh Jalalgarh 9B
310 Purnea (WLS (Q) Jalalgarh Jalalgarh 9C
311 Purnea (WLS (Q) Jalalgarh Jalalgarh 10
312 Purnea (WLS (Q) Jalalgarh Jalalgarh 11A
313 Purnea (WLS (Q) Jalalgarh Jalalgarh 11B
314 Purnea (WLS (Q) Jalalgarh Jalalgarh 12
315 Purnea (WLS (Q) Jalalgarh Jalalgarh 13
316 Purnea (WLS (Q) Jalalgarh Jalalgarh 14A
317 Purnea (WLS (Q) Jalalgarh Jalalgarh 14B
318 Purnea (WLS (Q) Jalalgarh Jalalgarh 15A
319 Purnea (WLS (Q) Jalalgarh Jalalgarh 15B
320 Purnea (WLS (Q) Jalalgarh Nizgehuwan 1
321 Purnea (WLS (Q) Jalalgarh Nizgehuwan 2
322 Purnea (WLS (Q) Jalalgarh Nizgehuwan 4
323 Purnea (WLS (Q) Jalalgarh Nizgehuwan 5
324 Purnea (WLS (Q) Jalalgarh Nizgehuwan 6
325 Purnea (WLS (Q) Jalalgarh Sarsauni 9
326 Purnea (WLS (Q) Jalalgarh Sarsauni 10
327 Purnea (WLS (Q) Jalalgarh Sarsauni 11
328 Purnea (WLS (Q) Jalalgarh Sarsauni 12
329 Purnea (WLS (Q) Jalalgarh Southa 5
330 Purnea (WLS (Q) Jalalgarh Southa 6
331 Purnea (WLS (Q) Jalalgarh Southa 7
332 Purnea (WLS (Q) Jalalgarh Southa 1
333 Purnea (WLS (Q) Jalalgarh Southa 2
334 Purnea (WLS (Q) Jalalgarh Southa 3
335 Purnea (WLS (Q) Jalalgarh Southa 4
336 Purnea (WLS (Q) Purnea East Bhoga Kariyat 1
337 Purnea (WLS (Q) Purnea East Bhoga Kariyat 2
338 Purnea (WLS (Q) Purnea East Bhoga Kariyat 3
339 Purnea (WLS (Q) Purnea East Bhoga Kariyat 4
340 Purnea (WLS (Q) Purnea East Bhoga Kariyat 5
341 Purnea (WLS (Q) Purnea East Bhoga Kariyat 6
342 Purnea (WLS (Q) Purnea East Bhoga Kariyat 7
343 Purnea (WLS (Q) Purnea East Bhoga Kariyat 8
344 Purnea (WLS (Q) Purnea East Bhoga Kariyat 9
345 Purnea (WLS (Q) Purnea East Bhoga Kariyat 10
346 Purnea (WLS (Q) Purnea East Bhoga Kariyat 11
347 Purnea (WLS (Q) Purnea East Bhoga Kariyat 12
348 Purnea (WLS (Q) Purnea East Birpur 6
349 Purnea (WLS (Q) Purnea East Birpur 7
350 Purnea (WLS (Q) Purnea East Birpur 8
351 Purnea (WLS (Q) Purnea East Birpur 9
352 Purnea (WLS (Q) Purnea East Birpur 14
353 Purnea (WLS (Q) Purnea East Birpur 5A
354 Purnea (WLS (Q) Purnea East Birpur 5B
355 Purnea (WLS (Q) Purnea East Birpur 10
356 Purnea (WLS (Q) Purnea East Birpur 11
357 Purnea (WLS (Q) Purnea East Birpur 12
358 Purnea (WLS (Q) Purnea East Birpur 13
359 Purnea (WLS (Q) Purnea East Biyarpur 1
360 Purnea (WLS (Q) Purnea East Biyarpur 2
361 Purnea (WLS (Q) Purnea East Biyarpur 3
362 Purnea (WLS (Q) Purnea East Biyarpur 4
363 Purnea (WLS (Q) Purnea East Biyarpur 5
364 Purnea (WLS (Q) Purnea East Biyarpur 6
365 Purnea (WLS (Q) Purnea East Biyarpur 7
366 Purnea (WLS (Q) Purnea East Biyarpur 8
367 Purnea (WLS (Q) Purnea East Biyarpur 9
368 Purnea (WLS (Q) Purnea East Biyarpur 10
369 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 1
370 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 2
371 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 3
372 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 4
373 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 5
374 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 6
375 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 7
376 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 8
377 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 9
378 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 10
379 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 11
380 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 12A
381 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 12B
382 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 13
383 Purnea (WLS (Q) Purnea East Dimiya Chatarjan 14
384 Purnea (WLS (Q) Purnea East Bikrampur 1
385 Purnea (WLS (Q) Purnea East Bikrampur 2
386 Purnea (WLS (Q) Purnea East Bikrampur 3
387 Purnea (WLS (Q) Purnea East Bikrampur 4
388 Purnea (WLS (Q) Purnea East Bikrampur 5
389 Purnea (WLS (Q) Purnea East Bikrampur 6
390 Purnea (WLS (Q) Purnea East Bikrampur 7
391 Purnea (WLS (Q) Purnea East Bikrampur 8
392 Purnea (WLS (Q) Purnea East Bikrampur 9
393 Purnea (WLS (Q) Purnea East Bikrampur 10
394 Purnea (WLS (Q) Purnea East Bikrampur 11
395 Purnea (WLS (Q) Purnea East Gaura 1
396 Purnea (WLS (Q) Purnea East Gaura 2
397 Purnea (WLS (Q) Purnea East Gaura 3
398 Purnea (WLS (Q) Purnea East Gaura 4
399 Purnea (WLS (Q) Purnea East Gaura 5
400 Purnea (WLS (Q) Purnea East Gaura 6
401 Purnea (WLS (Q) Purnea East Gaura 7
402 Purnea (WLS (Q) Purnea East Gaura 8
403 Purnea (WLS (Q) Purnea East Gaura 9
404 Purnea (WLS (Q) Purnea East Gaura 11
405 Purnea (WLS (Q) Purnea East Gaura 14
406 Purnea (WLS (Q) Purnea East Gaura 10
407 Purnea (WLS (Q) Purnea East Gaura 11
408 Purnea (WLS (Q) Purnea East Gaura 13
409 Purnea (WLS (Q) Purnea East Gaura 15
410 Purnea (WLS (Q) Purnea East Harda 5A
411 Purnea (WLS (Q) Purnea East Harda 5B
412 Purnea (WLS (Q) Purnea East Harda 6A
413 Purnea (WLS (Q) Purnea East Harda 6B
414 Purnea (WLS (Q) Purnea East Harda 7A
415 Purnea (WLS (Q) Purnea East Harda 7B
416 Purnea (WLS (Q) Purnea East Harda 8A
417 Purnea (WLS (Q) Purnea East Harda 8B
418 Purnea (WLS (Q) Purnea East Harda 11A
419 Purnea (WLS (Q) Purnea East Harda 11B
420 Purnea (WLS (Q) Purnea East Harda 12
421 Purnea (WLS (Q) Purnea East Harda 13A
422 Purnea (WLS (Q) Purnea East Harda 13B
423 Purnea (WLS (Q) Purnea East Harda 14A
424 Purnea (WLS (Q) Purnea East Harda 14B
425 Purnea (WLS (Q) Purnea East Harda 9A
426 Purnea (WLS (Q) Purnea East Harda 09B
427 Purnea (WLS (Q) Purnea East Harda 10A
428 Purnea (WLS (Q) Purnea East Harda 10B
429 Purnea (WLS (Q) Purnea East Harda 1A
430 Purnea (WLS (Q) Purnea East Harda 1B
431 Purnea (WLS (Q) Purnea East Harda 2A
432 Purnea (WLS (Q) Purnea East Kabaiya 4B
433 Purnea (WLS (Q) Purnea East Maharajpur 6
434 Purnea (WLS (Q) Purnea East Maharajpur 7
435 Purnea (WLS (Q) Purnea East Maharajpur 8
436 Purnea (WLS (Q) Purnea East Maharajpur 2A
437 Purnea (WLS (Q) Purnea East Maharajpur 2B
438 Purnea (WLS (Q) Purnea East Maharajpur 13
439 Purnea (WLS (Q) Purnea East Maharajpur 14
440 Purnea (WLS (Q) Purnea East Maharajpur 1
441 Purnea (WLS (Q) Purnea East Maharajpur 3
442 Purnea (WLS (Q) Purnea East Maharajpur 9
443 Purnea (WLS (Q) Purnea East Maharajpur 10
444 Purnea (WLS (Q) Purnea East Maharajpur 11
445 Purnea (WLS (Q) Purnea East Maharajpur 12
446 Purnea (WLS (Q) Purnea East Rajiganj 1
447 Purnea (WLS (Q) Purnea East Rajiganj 2
448 Purnea (WLS (Q) Purnea East Rajiganj 3
449 Purnea (WLS (Q) Purnea East Rajiganj 4
450 Purnea (WLS (Q) Purnea East Rajiganj 5
451 Purnea (WLS (Q) Purnea East Rajiganj 6
452 Purnea (WLS (Q) Purnea East Rajiganj 7
453 Purnea (WLS (Q) Purnea East Rajiganj 8
454 Purnea (WLS (Q) Purnea East Rajiganj 9A
455 Purnea (WLS (Q) Purnea East Rajiganj 9B
456 Purnea (WLS (Q) Purnea East Rajiganj 10
457 Purnea (WLS (Q) Purnea East Rampur 9
458 Purnea (WLS (Q) Purnea East Rampur 10
459 Purnea (WLS (Q) Purnea East Rampur 11
460 Purnea (WLS (Q) Purnea East Rampur 12
461 Purnea (WLS (Q) Purnea East Shikandar Pur 1
462 Purnea (WLS (Q) Purnea East Shikandar Pur 2
463 Purnea (WLS (Q) Purnea East Shikandar Pur 3
464 Purnea (WLS (Q) Purnea East Shikandar Pur 4A
465 Purnea (WLS (Q) Purnea East Shikandar Pur 4B
466 Purnea (WLS (Q) Purnea East Shikandar Pur 5A
467 Purnea (WLS (Q) Purnea East Shikandar Pur 5B
468 Purnea (WLS (Q) Purnea East Shikandar Pur 6
469 Purnea (WLS (Q) Purnea East Shikandar Pur 7A
470 Purnea (WLS (Q) Purnea East Shikandar Pur 7B
471 Purnea (WLS (Q) Purnea East Shikandar Pur 8A
472 Purnea (WLS (Q) Purnea East Shikandar Pur 8B
473 Purnea (WLS (Q) Purnea East Shikandar Pur 9
474 Purnea (WLS (Q) Purnea East Shikandar Pur 10
475 Purnea (WLS (Q) Purnea East Shikandar Pur 11
476 Purnea (WLS (Q) Purnea East Shikandar Pur 12
477 Purnea (WLS (Q) Purnea East Shikandar Pur 13A
478 Purnea (WLS (Q) Purnea East Shikandar Pur 13B
479 Purnea (WLS (Q) Purnea East Shikandar Pur 14
480 Purnea (WLS (Q) Dagarua Adkeli 6A
481 Purnea (WLS (Q) Dagarua Adkeli 9B
482 Purnea (WLS (Q) Dagarua Adkeli 1
483 Purnea (WLS (Q) Dagarua Adkeli 2
484 Purnea (WLS (Q) Dagarua Adkeli 3
485 Purnea (WLS (Q) Dagarua Adkeli 4
486 Purnea (WLS (Q) Dagarua Adkeli 5
487 Purnea (WLS (Q) Dagarua Adkeli 6
488 Purnea (WLS (Q) Dagarua Adkeli 7
489 Purnea (WLS (Q) Dagarua Adkeli 8
490 Purnea (WLS (Q) Dagarua Adkeli 9
491 Purnea (WLS (Q) Dagarua Adkeli 10
492 Purnea (WLS (Q) Dagarua Adkeli 11
493 Purnea (WLS (Q) Dagarua Adkeli 12
494 Purnea (WLS (Q) Dagarua Adkeli 13
495 Purnea (WLS (Q) Dagarua Adkeli 14
496 Purnea (WLS (Q) Dagarua Adkeli 15
497 Purnea (WLS (Q) Dagarua Belgachhi 12
498 Purnea (WLS (Q) Dagarua Belgachhi 13
499 Purnea (WLS (Q) Dagarua Belgachhi 14
500 Purnea (WLS (Q) Dagarua Belgachhi 2A
501 Purnea (WLS (Q) Dagarua Belgachhi 2B
502 Purnea (WLS (Q) Dagarua Belgachhi 7
503 Purnea (WLS (Q) Dagarua Belgachhi 8
504 Purnea (WLS (Q) Dagarua Belgachhi 9
505 Purnea (WLS (Q) Dagarua Belgachhi 10
506 Purnea (WLS (Q) Dagarua Belgachhi 11
507 Purnea (WLS (Q) Dagarua Belgachhi 1
508 Purnea (WLS (Q) Dagarua Belgachhi 3
509 Purnea (WLS (Q) Dagarua Belgachhi 4
510 Purnea (WLS (Q) Dagarua Belgachhi 5
511 Purnea (WLS (Q) Dagarua Belgachhi 6
512 Purnea (WLS (Q) Dagarua Buwari 1A
513 Purnea (WLS (Q) Dagarua Buwari 1B
514 Purnea (WLS (Q) Dagarua Buwari 2
515 Purnea (WLS (Q) Dagarua Buwari 3
516 Purnea (WLS (Q) Dagarua Buwari 4
517 Purnea (WLS (Q) Dagarua Buwari 05A
518 Purnea (WLS (Q) Dagarua Buwari 05B
519 Purnea (WLS (Q) Dagarua Dagarua 4
520 Purnea (WLS (Q) Dagarua Dagarua 5A
521 Purnea (WLS (Q) Dagarua Dagarua 5B
522 Purnea (WLS (Q) Dagarua Dagarua 6
523 Purnea (WLS (Q) Dagarua Dagarua 10A
524 Purnea (WLS (Q) Dagarua Dagarua 10B
525 Purnea (WLS (Q) Dagarua Dagarua 11
526 Purnea (WLS (Q) Dagarua Dagarua 12
527 Purnea (WLS (Q) Dagarua Dagarua 13
528 Purnea (WLS (Q) Dagarua Dariapur 14A
529 Purnea (WLS (Q) Dagarua Dariapur 14B
530 Purnea (WLS (Q) Dagarua Dariapur 1
531 Purnea (WLS (Q) Dagarua Dariapur 2
532 Purnea (WLS (Q) Dagarua Dariapur 4
533 Purnea (WLS (Q) Dagarua Dariapur 3A
534 Purnea (WLS (Q) Dagarua Dariapur 3B
535 Purnea (WLS (Q) Dagarua Dariapur 5
536 Purnea (WLS (Q) Dagarua Dariapur 06A
537 Purnea (WLS (Q) Dagarua Dariapur 06B
538 Purnea (WLS (Q) Dagarua Dariapur 7
539 Purnea (WLS (Q) Dagarua Dariapur 8
540 Purnea (WLS (Q) Dagarua Dariapur 09A
541 Purnea (WLS (Q) Dagarua Dariapur 09B
542 Purnea (WLS (Q) Dagarua Dariapur 10A
543 Purnea (WLS (Q) Dagarua Dariapur 10B
544 Purnea (WLS (Q) Dagarua Dariapur 15A
545 Purnea (WLS (Q) Dagarua Dariapur 15B
546 Purnea (WLS (Q) Dagarua Duweli 5
547 Purnea (WLS (Q) Dagarua Duweli 6
548 Purnea (WLS (Q) Dagarua Duweli 7A
549 Purnea (WLS (Q) Dagarua Duweli 7B
550 Purnea (WLS (Q) Dagarua Duweli 11A
551 Purnea (WLS (Q) Dagarua Duweli 11B
552 Purnea (WLS (Q) Dagarua Duweli 12
553 Purnea (WLS (Q) Dagarua Duweli 13
554 Purnea (WLS (Q) Dagarua Duweli 1
555 Purnea (WLS (Q) Dagarua Duweli 2
556 Purnea (WLS (Q) Dagarua Duweli 3
557 Purnea (WLS (Q) Dagarua Duweli 4
558 Purnea (WLS (Q) Dagarua Harkheli 15A
559 Purnea (WLS (Q) Dagarua Harkheli 15B
560 Purnea (WLS (Q) Dagarua Harkheli 15C
561 Purnea (WLS (Q) Dagarua Harkheli 1
562 Purnea (WLS (Q) Dagarua Harkheli 2A
563 Purnea (WLS (Q) Dagarua Harkheli 2B
564 Purnea (WLS (Q) Dagarua Harkheli 3A
565 Purnea (WLS (Q) Dagarua Harkheli 3B
566 Purnea (WLS (Q) Dagarua Harkheli 4
567 Purnea (WLS (Q) Dagarua Harkheli 5A
568 Purnea (WLS (Q) Dagarua Harkheli 5B
569 Purnea (WLS (Q) Dagarua Harkheli 6A
570 Purnea (WLS (Q) Dagarua Harkheli 6B
571 Purnea (WLS (Q) Dagarua Harkheli 7
572 Purnea (WLS (Q) Dagarua Harkheli 8
573 Purnea (WLS (Q) Dagarua Harkheli 9A
574 Purnea (WLS (Q) Dagarua Harkheli 9B
575 Purnea (WLS (Q) Dagarua Harkheli 10
576 Purnea (WLS (Q) Dagarua Harkheli 11
577 Purnea (WLS (Q) Dagarua Harkheli 12
578 Purnea (WLS (Q) Dagarua Harkheli 13
579 Purnea (WLS (Q) Dagarua Harkheli 14
580 Purnea (WLS (Q) Dagarua Kohila 1
581 Purnea (WLS (Q) Dagarua Kohila 2
582 Purnea (WLS (Q) Dagarua Kohila 3
583 Purnea (WLS (Q) Dagarua Kohila 4
584 Purnea (WLS (Q) Dagarua Kohila 5
585 Purnea (WLS (Q) Dagarua Kohila 6
586 Purnea (WLS (Q) Dagarua Kohila 7
587 Purnea (WLS (Q) Dagarua Kohila 8
588 Purnea (WLS (Q) Dagarua Kohila 9
589 Purnea (WLS (Q) Dagarua Kohila 10
590 Purnea (WLS (Q) Dagarua Kohila 11
591 Purnea (WLS (Q) Dagarua Kohila 12
592 Purnea (WLS (Q) Dagarua Kohila 13
593 Purnea (WLS (Q) Dagarua Kohila 14
594 Purnea (WLS (Q) Dagarua Chanpi 1A
595 Purnea (WLS (Q) Dagarua Chanpi 1B
596 Purnea (WLS (Q) Dagarua Chanpi 2
597 Purnea (WLS (Q) Dagarua Chanpi 3
598 Purnea (WLS (Q) Dagarua Chanpi 4
599 Purnea (WLS (Q) Dagarua Chanpi 5
600 Purnea (WLS (Q) Dagarua Chanpi 6
601 Purnea (WLS (Q) Dagarua Chanpi 7
602 Purnea (WLS (Q) Dagarua Chanpi 8
603 Purnea (WLS (Q) Dagarua Chanpi 9
604 Purnea (WLS (Q) Dagarua Chanpi 10
605 Purnea (WLS (Q) Dagarua Chanpi 11
606 Purnea (WLS (Q) Dagarua Chanpi 12
607 Purnea (WLS (Q) Dagarua Chanpi 13
608 Purnea (WLS (Q) Dagarua Chanpi 14
609 Purnea (WLS (Q) Dagarua Chanpi 15
610 Purnea (WLS (Q) Dagarua Mahthor 1
611 Purnea (WLS (Q) Dagarua Mahthor 2A
612 Purnea (WLS (Q) Dagarua Mahthor 2B
613 Purnea (WLS (Q) Dagarua Mahthor 3A
614 Purnea (WLS (Q) Dagarua Mahthor 3B
615 Purnea (WLS (Q) Dagarua Mahthor 4
616 Purnea (WLS (Q) Dagarua Mahthor 5
617 Purnea (WLS (Q) Dagarua Mahthor 6A
618 Purnea (WLS (Q) Dagarua Mahthor 6B
619 Purnea (WLS (Q) Dagarua Mahthor 7
620 Purnea (WLS (Q) Dagarua Mahthor 8
621 Purnea (WLS (Q) Dagarua Mahthor 9
622 Purnea (WLS (Q) Dagarua Mahthor 10
623 Purnea (WLS (Q) Dagarua Mahthor 11
624 Purnea (WLS (Q) Dagarua Mahthor 12
625 Purnea (WLS (Q) Dagarua Mahthor 13A
626 Purnea (WLS (Q) Dagarua Mahthor 13B
627 Purnea (WLS (Q) Dagarua Mahthor 14
628 Purnea (WLS (Q) Dagarua Mahthor 15A
629 Purnea (WLS (Q) Dagarua Mahthor 15B
630 Purnea (WLS (Q) Dagarua Majgama 12
631 Purnea (WLS (Q) Dagarua Majgama 13
632 Purnea (WLS (Q) Dagarua Majgama 14
633 Purnea (WLS (Q) Dagarua Majgama 8
634 Purnea (WLS (Q) Dagarua Majgama 10
635 Purnea (WLS (Q) Dagarua Majgama 11
636 Purnea (WLS (Q) Dagarua Majgama 9A
637 Purnea (WLS (Q) Dagarua Majgama 9B
638 Purnea (WLS (Q) Dagarua Majgama 1
639 Purnea (WLS (Q) Dagarua Majgama 2
640 Purnea (WLS (Q) Dagarua Majgama 3
641 Purnea (WLS (Q) Dagarua Majgama 4
642 Purnea (WLS (Q) Dagarua Majgama 5
643 Purnea (WLS (Q) Dagarua Majgama 6
644 Purnea (WLS (Q) Dagarua Majgama 7
645 Purnea (WLS (Q) Dagarua Rampur 1
646 Purnea (WLS (Q) Dagarua Rampur 2
647 Purnea (WLS (Q) Dagarua Rampur 3
648 Purnea (WLS (Q) Dagarua Rampur 4
649 Purnea (WLS (Q) Dagarua Rampur 5
650 Purnea (WLS (Q) Dagarua Rampur 6
651 Purnea (WLS (Q) Dagarua Rampur 7
652 Purnea (WLS (Q) Dagarua Rampur 8
653 Purnea (WLS (Q) Dagarua Rampur 9
654 Purnea (WLS (Q) Dagarua Rampur 10
655 Purnea (WLS (Q) Dagarua Rampur 11
656 Purnea (WLS (Q) Dagarua Rampur 12
657 Purnea (WLS (Q) Dagarua Rampur 13
658 Purnea (WLS (Q) Dagarua Rampur 14
659 Purnea (WLS (Q) Dagarua Toli 1
660 Purnea (WLS (Q) Dagarua Toli 2
661 Purnea (WLS (Q) Dagarua Toli 3
662 Purnea (WLS (Q) Dagarua Toli 4
663 Purnea (WLS (Q) Dagarua Toli 5
664 Purnea (WLS (Q) Dagarua Toli 6
665 Purnea (WLS (Q) Dagarua Toli 7
666 Purnea (WLS (Q) Dagarua Toli 8A
667 Purnea (WLS (Q) Dagarua Toli 8B
668 Purnea (WLS (Q) Dagarua Toli 9
669 Purnea (WLS (Q) Dagarua Toli 10
670 Purnea (WLS (Q) Dagarua Toli 11
671 Purnea (WLS (Q) Dagarua Toli 12
672 Purnea (WLS (Q) Dagarua Toli 13
673 Purnea (WLS (Q) Dagarua Toli 14A
674 Purnea (WLS (Q) Dagarua Toli 14B
675 Purnea (WLS (Q) Baisi Baisi 5B
676 Purnea (WLS (Q) Baisi Baisi 8
677 Purnea (WLS (Q) Baisi Baisi 14
678 Purnea (WLS (Q) Baisi Baisi 15
679 Purnea (WLS (Q) Baisi Baisi 16
680 Purnea (WLS (Q) Baisi Baisi 1
681 Purnea (WLS (Q) Baisi Baisi 2
682 Purnea (WLS (Q) Baisi Baisi 3
683 Purnea (WLS (Q) Baisi Baisi 4A
684 Purnea (WLS (Q) Baisi Baisi 4B
685 Purnea (WLS (Q) Baisi Baisi 5
686 Purnea (WLS (Q) Baisi Bangama 2
687 Purnea (WLS (Q) Baisi Bangama 3A
688 Purnea (WLS (Q) Baisi Bangama 3B
689 Purnea (WLS (Q) Baisi Bangama 4
690 Purnea (WLS (Q) Baisi Bangama 5
691 Purnea (WLS (Q) Baisi Bangama 6
692 Purnea (WLS (Q) Baisi Bangama 13
693 Purnea (WLS (Q) Baisi Bangama 14
694 Purnea (WLS (Q) Baisi Bangama 15
695 Purnea (WLS (Q) Baisi Chandragama 1
696 Purnea (WLS (Q) Baisi Chandragama 2
697 Purnea (WLS (Q) Baisi Chandragama 3
698 Purnea (WLS (Q) Baisi Chandragama 10
699 Purnea (WLS (Q) Baisi Chandragama 11A
700 Purnea (WLS (Q) Baisi Chandragama 11B
701 Purnea (WLS (Q) Baisi Cheraiya 1
702 Purnea (WLS (Q) Baisi Cheraiya 2
703 Purnea (WLS (Q) Baisi Cheraiya 3
704 Purnea (WLS (Q) Baisi Cheraiya 4
705 Purnea (WLS (Q) Baisi Chopra 10
706 Purnea (WLS (Q) Baisi Chopra 11
707 Purnea (WLS (Q) Baisi Chopra 12
708 Purnea (WLS (Q) Baisi Chopra 13
709 Purnea (WLS (Q) Baisi Chopra 7
710 Purnea (WLS (Q) Baisi Chopra 8
711 Purnea (WLS (Q) Baisi Chopra 9
712 Purnea (WLS (Q) Baisi Chopra 1
713 Purnea (WLS (Q) Baisi Chopra 2
714 Purnea (WLS (Q) Baisi Chopra 3
715 Purnea (WLS (Q) Baisi Chopra 4
716 Purnea (WLS (Q) Baisi Chopra 5
717 Purnea (WLS (Q) Baisi Chopra 6
718 Purnea (WLS (Q) Baisi Khapra 11B
719 Purnea (WLS (Q) Baisi Khapra 1A
720 Purnea (WLS (Q) Baisi Khapra 1B
721 Purnea (WLS (Q) Baisi Khapra 2
722 Purnea (WLS (Q) Baisi Khapra 3
723 Purnea (WLS (Q) Baisi Khapra 4
724 Purnea (WLS (Q) Baisi Khapra 5
725 Purnea (WLS (Q) Baisi Khapra 6
726 Purnea (WLS (Q) Baisi Khapra 7
727 Purnea (WLS (Q) Baisi Khapra 8
728 Purnea (WLS (Q) Baisi Khapra 9A
729 Purnea (WLS (Q) Baisi Khapra 9B
730 Purnea (WLS (Q) Baisi Khapra 10
731 Purnea (WLS (Q) Baisi Khapra 11
732 Purnea (WLS (Q) Baisi Khapra 12
733 Purnea (WLS (Q) Baisi Khapra 13
734 Purnea (WLS (Q) Baisi Khapra 14
735 Purnea (WLS (Q) Baisi Kuthiya 1
736 Purnea (WLS (Q) Baisi Kuthiya 2
737 Purnea (WLS (Q) Baisi Kuthiya 3
738 Purnea (WLS (Q) Baisi Kuthiya 4
739 Purnea (WLS (Q) Baisi Kuthiya 5
740 Purnea (WLS (Q) Baisi Kuthiya 6
741 Purnea (WLS (Q) Baisi Malhariya 8A
742 Purnea (WLS (Q) Baisi Malhariya 8B
743 Purnea (WLS (Q) Baisi Malhariya 9
744 Purnea (WLS (Q) Baisi Malhariya 10
745 Purnea (WLS (Q) Baisi Malhariya 1
746 Purnea (WLS (Q) Baisi Malhariya 2
747 Purnea (WLS (Q) Baisi Malhariya 3
748 Purnea (WLS (Q) Baisi Malhariya 13A
749 Purnea (WLS (Q) Baisi Malhariya 13B
750 Purnea (WLS (Q) Baisi Malhariya 14
751 Purnea (WLS (Q) Baisi Malhariya 5C
752 Purnea (WLS (Q) Baisi Malhariya 6
753 Purnea (WLS (Q) Baisi Malhariya 7A
754 Purnea (WLS (Q) Baisi Malhariya 7B
755 Purnea (WLS (Q) Baisi Malhariya 4
756 Purnea (WLS (Q) Baisi Malhariya 5A
757 Purnea (WLS (Q) Baisi Malhariya 5B
758 Purnea (WLS (Q) Baisi Malhariya 11
759 Purnea (WLS (Q) Baisi Malhariya 12
760 Purnea (WLS (Q) Baisi Minapur 10B
761 Purnea (WLS (Q) Baisi Minapur 11
762 Purnea (WLS (Q) Baisi Minapur 12
763 Purnea (WLS (Q) Baisi Minapur 16
764 Purnea (WLS (Q) Baisi Minapur 17
765 Purnea (WLS (Q) Baisi Minapur 18A
766 Purnea (WLS (Q) Baisi Minapur 18B
767 Purnea (WLS (Q) Baisi Minapur 19
768 Purnea (WLS (Q) Baisi Minapur 20
769 Purnea (WLS (Q) Baisi Minapur 21A
770 Purnea (WLS (Q) Baisi Puranaganj 15A
771 Purnea (WLS (Q) Baisi Puranaganj 15B
772 Purnea (WLS (Q) Baisi Puranaganj 15C
773 Purnea (WLS (Q) Baisi Puranaganj 5A
774 Purnea (WLS (Q) Baisi Puranaganj 5B
775 Purnea (WLS (Q) Baisi Puranaganj 6
776 Purnea (WLS (Q) Baisi Puranaganj 7A
777 Purnea (WLS (Q) Baisi Puranaganj 7B
778 Purnea (WLS (Q) Baisi Puranaganj 8
779 Purnea (WLS (Q) Baisi Puranaganj 9
780 Purnea (WLS (Q) Baisi Puranaganj 10
781 Purnea (WLS (Q) Baisi Puranaganj 11
782 Purnea (WLS (Q) Baisi Puranaganj 1A
783 Purnea (WLS (Q) Baisi Puranaganj 1B
784 Purnea (WLS (Q) Baisi Puranaganj 2A
785 Purnea (WLS (Q) Baisi Puranaganj 2B
786 Purnea (WLS (Q) Baisi Puranaganj 3A
787 Purnea (WLS (Q) Baisi Puranaganj 3B
788 Purnea (WLS (Q) Baisi Puranaganj 4A
789 Purnea (WLS (Q) Baisi Puranaganj 4B
790 Purnea (WLS (Q) Baisi Puranaganj 12
791 Purnea (WLS (Q) Baisi Puranaganj 13
792 Purnea (WLS (Q) Baisi Puranaganj 14A
793 Purnea (WLS (Q) Baisi Puranaganj 14B
794 Purnea (WLS (Q) Baisi Puranaganj 15D
795 Purnea (WLS (Q) Baisi Puranaganj 15E
796 Purnea (WLS (Q) Baisi Sripur Mallah toli 1
797 Purnea (WLS (Q) Baisi Sripur Mallah toli 2
798 Purnea (WLS (Q) Baisi Sripur Mallah toli 3
799 Purnea (WLS (Q) Baisi Sripur Mallah toli 4
800 Purnea (WLS (Q) Baisi Sripur Mallah toli 5A
801 Purnea (WLS (Q) Baisi Sripur Mallah toli 5B
802 Purnea (WLS (Q) Baisi Sripur Mallah toli 6
803 Purnea (WLS (Q) Baisi Sripur Mallah toli 7
804 Purnea (WLS (Q) Baisi Sripur Mallah toli 8
805 Purnea (WLS (Q) Baisi Sugawa Mahanandpur 1
806 Purnea (WLS (Q) Baisi Sugawa Mahanandpur 2
807 Purnea (WLS (Q) Baisi Sugawa Mahanandpur 3
808 Purnea (WLS (Q) Baisi Sugawa Mahanandpur 4
809 Purnea (WLS (Q) Baisi Sugawa Mahanandpur 5
810 Purnea (WLS (Q) Baisi Sugawa Mahanandpur 6
811 Purnea (WLS (Q) Baisi Sugawa Mahanandpur 7
812 Purnea (WLS (Q) Baisi Sugawa Mahanandpur 8
813 Purnea (WLS (Q) Baisi Sugawa Mahanandpur 9
814 Purnea (WLS (Q) Amour Amgachhi 9B
815 Purnea (WLS (Q) Amour Amgachhi 10A
816 Purnea (WLS (Q) Amour Amgachhi 10B
817 Purnea (WLS (Q) Amour Amgachhi 12
818 Purnea (WLS (Q) Amour Amgachhi 13A
819 Purnea (WLS (Q) Amour Amgachhi 13B
820 Purnea (WLS (Q) Amour Bakania Baraili 8
821 Purnea (WLS (Q) Amour Bakania Baraili 9A
822 Purnea (WLS (Q) Amour Bakania Baraili 9B
823 Purnea (WLS (Q) Amour Bakania Baraili 10
824 Purnea (WLS (Q) Amour Bakania Baraili 11A
825 Purnea (WLS (Q) Amour Bakania Baraili 11B
826 Purnea (WLS (Q) Amour Bakania Baraili 12
827 Purnea (WLS (Q) Amour Bakania Baraili 13
828 Purnea (WLS (Q) Amour Bakania Baraili 14
829 Purnea (WLS (Q) Amour Bhawanipur 13
830 Purnea (WLS (Q) Amour Bhawanipur 14A
831 Purnea (WLS (Q) Amour Bhawanipur 14B
832 Purnea (WLS (Q) Amour Bhawanipur 15
833 Purnea (WLS (Q) Amour DahuaBari 1A
834 Purnea (WLS (Q) Amour DahuaBari 1B
835 Purnea (WLS (Q) Amour DahuaBari 2A
836 Purnea (WLS (Q) Amour DahuaBari 6B
837 Purnea (WLS (Q) Amour DahuaBari 7A
838 Purnea (WLS (Q) Amour DahuaBari 7B
839 Purnea (WLS (Q) Amour DahuaBari 13
840 Purnea (WLS (Q) Amour DahuaBari 14
841 Purnea (WLS (Q) Amour Dhurpaili 1
842 Purnea (WLS (Q) Amour Dhurpaili 2
843 Purnea (WLS (Q) Amour Dhurpaili 3
844 Purnea (WLS (Q) Amour Hafaniya 9
845 Purnea (WLS (Q) Amour Hafaniya 10
846 Purnea (WLS (Q) Amour Hafaniya 1A
847 Purnea (WLS (Q) Amour Hafaniya 1B
848 Purnea (WLS (Q) Amour Haripur 9
849 Purnea (WLS (Q) Amour Haripur 10
850 Purnea (WLS (Q) Amour Haripur 11
851 Purnea (WLS (Q) Amour Nitender 1
852 Purnea (WLS (Q) Amour Nitender 2
853 Purnea (WLS (Q) Amour Nitender 3
854 Purnea (WLS (Q) Amour Nitender 4
855 Purnea (WLS (Q) Amour Nitender 5A
856 Purnea (WLS (Q) Amour Nitender 5B
857 Purnea (WLS (Q) Amour Nitender 7B
858 Purnea (WLS (Q) Amour Nitender 8
859 Purnea (WLS (Q) Amour Nitender 9
860 Purnea (WLS (Q) Amour Nitender 10
861 Purnea (WLS (Q) Amour Nitender 11
862 Purnea (WLS (Q) Amour Talbari 12A
863 Purnea (WLS (Q) Amour Talbari 12B
864 Purnea (WLS (Q) Amour Talbari 1A
865 Purnea (WLS (Q) Amour Talbari 1B
866 Purnea (WLS (Q) Amour Talbari 2A
867 Purnea (WLS (Q) Amour Talbari 2B
868 Purnea (WLS (Q) Amour Talbari 3
869 Purnea (WLS (Q) Amour Talbari 4
870 Purnea (WLS (Q) Amour Talbari 5
871 Purnea (WLS (Q) Amour Talbari 6
872 Purnea (WLS (Q) Amour Talbari 7
873 Purnea (WLS (Q) Amour Talbari 10B
874 Purnea (WLS (Q) Amour Talbari 11A
875 Purnea (WLS (Q) Amour Talbari 11
876 Purnea (WLS (Q) Amour Talbari 13A
877 Purnea (WLS (Q) Amour Talbari 13B
878 Purnea (WLS (Q) Baisa Dhusmal 6
879 Purnea (WLS (Q) Baisa Dhusmal 7
880 Purnea (WLS (Q) Baisa Dhusmal 8A
881 Purnea (WLS (Q) Baisa Khapra 1A
882 Purnea (WLS (Q) Baisa Khapra 1B
883 Purnea (WLS (Q) Baisa Khapra 2
884 Purnea (WLS (Q) Baisa Khapra 3
885 Purnea (WLS (Q) Baisa Khapra 4
886 Purnea (WLS (Q) Baisa Khapra 5
887 Purnea (WLS (Q) Baisa Khapra 6
888 Purnea (WLS (Q) Baisa Khapra 7
889 Purnea (WLS (Q) Baisa Khapra 8
890 Purnea (WLS (Q) Baisa Khapra 9
891 Purnea (WLS (Q) Baisa Khapra 10
892 Purnea (WLS (Q) Baisa Khapra 11
893 Purnea (WLS (Q) Baisa Khapra 12
894 Purnea (WLS (Q) Baisa Khapra 13
895 Purnea (WLS (Q) Baisa Khapra 14
896 Purnea (WLS (Q) Baisa Khapra 15
897 Purnea (WLS (Q) Baisa Nandniya 4
898 Purnea (WLS (Q) Baisa Nandniya 5
899 Purnea (WLS (Q) Baisa Nandniya 6
900 Purnea (WLS (Q) Baisa Nandniya 7A
901 Purnea (WLS (Q) Baisa Nandniya 7B
902 Purnea (WLS (Q) Baisa Nandniya 8
903 Purnea (WLS (Q) Baisa Routa 12A
904 Purnea (WLS (Q) Baisa Routa 12B
905 Purnea (WLS (Q) Baisa Routa 13A
906 Purnea (WLS (Q) Baisa Routa 10A
907 Purnea (WLS (Q) Baisa Routa 10B
908 Purnea (WLS (Q) Baisa Routa 11
909 Purnea (WLS (Q) Baisa Routa 1A
910 Purnea (WLS (Q) Baisa Routa 1B
911 Purnea (WLS (Q) Baisa Routa 2A
912 Purnea (WLS (Q) Baisa Routa 2B
913 Purnea (WLS (Q) Baisa Routa 3A
914 Purnea (WLS (Q) Baisa Routa 3B
915 Purnea (WLS (Q) Baisa Routa 4
916 Purnea (WLS (Q) Baisa Routa 5
917 Purnea (WLS (Q) Baisa Routa 7
918 Purnea (WLS (Q) Baisa Shishabari 8A
919 Purnea (WLS (Q) Baisa Shishabari 8B
920 Purnea (WLS (Q) Baisa Shishabari 9
921 Purnea (WLS (Q) Baisa Shishabari 10
922 Purnea (WLS (Q) Baisa Shishabari 11
923 Purnea (WLS (Q) Baisa Shishabari 12A
924 Purnea (WLS (Q) Baisa Shishabari 12B
925 Purnea (WLS (Q) Baisa Shishabari 13
926 Purnea (WLS (Q) Baisa Shishabari 14
927 Purnea (WLS (Q) Amour Bakania Baraili 1
928 Purnea (WLS (Q) Amour Bakania Baraili 2
929 Purnea (WLS (Q) Amour Bakania Baraili 3A
930 Purnea (WLS (Q) Amour Bakania Baraili 3B
931 Purnea (WLS (Q) Amour Bakania Baraili 4
932 Purnea (WLS (Q) Amour Bakania Baraili 5
933 Purnea (WLS (Q) Amour Bakania Baraili 6
934 Purnea (WLS (Q) Amour Bakania Baraili 7A
935 Purnea (WLS (Q) Amour Bakania Baraili 7B
936 Purnea (WLS (Q) Amour Mjhuwa Hat 3
937 Purnea (WLS (Q) Amour Mjhuwa Hat 4
938 Purnea (WLS (Q) Amour Mjhuwa Hat 5
939 Purnea (WLS (Q) Baisa Khapra 1A
940 Purnea (WLS (Q) Baisa Khapra 2A
941 Purnea (WLS (Q) Baisa Khapra 5A
942 Purnea (WLS (Q) Baisa Khapra 11A
943 Purnea (WLS (Q) Baisa Malopada 14
944 Purnea (WLS (Q) Baisa Malopada 15
945 Purnea (WLS (Q) Baisa Sirsi 10A
946 Purnea (WLS (Q) Baisa Sirsi 14A
947 Purnea (WLS (Q) Amour Mjhuwa Hat 1
948 Purnea (WLS (Q) Amour Mjhuwa Hat 2A
949 Purnea (WLS (Q) Amour Mjhuwa Hat 2B
950 Purnea (WLS (Q) Amour Pothiya Gangaili 9
951 Purnea (WLS (Q) Amour Pothiya Gangaili 10
952 Purnea PWS Dagarua Dagarua Dagarua 7, 8, 9
953 Purnea PWS Baisa Baisa Routa 6, 8, 9
954 Purnea PWS Jalalgarh Jalalgarh Jalalgarh 7, 8
955 Purnea PWS Srinagar Srinagar Khuti Dhunali 9, 10
BoQ (Fixed Cost)
Name of Work-Comprehensive operation and maintenance routine repairs and Special repair of i) Rural Piped Water Supply Scheme (PWS). ii) Ward Level Piped Water Supply Schemes in quality affected wards (WLS-Quality) based on item rates: Constructed by the Public Health Engineering Department including payment to the pump operators, electricity bills for five Years. Water Supply Schemes under P.H.Division Purnea
1. BoQ (Fixed Cost) (WLS (Quality))
I. Fixed Costs (WLS (Q/NQ))
(a) Cost of pump operator
1 nos for 365 days per month 12 4000 48000
Sub Total a= 48000
(b) Cost of energy charges
Capacity of motor pump say 3 HP=(.746x3=2.24 kW) kW 2.24
Avg. running hrs,/day 8
Energy charges per year= avg. running hrs/dayx.746x3x365 per unit 6540.8 2.6 17006.08 17006.08
fixed charges per month 12 100 3600 1200
duty charges @6% of energy charge 1020.36 1020
SubTotal b= 21626.44
Total Fixed Cost (I) = 69626.44
Contractor's profit @ 10% on (II)= 6962.64
Add GST @ 18% on ( II)= 12532.76
Total Cost (I) 89121.85
TOTAL COST OF 951 SCHEME WLS 84754878.73
2. (i) BoQ (Fixed Cost) (PWS/SVS) : Jalalgarh PWS.
I. Fixed Costs (PWS/SVS)
(a) Cost of pump operator
1 nos for 365 days per month 48000 1 4000 48000
Sub Total a= 48000
(b) Cost of energy charges
Capacity of motor pump say 15 HP=(.746x15=11.19 kW) kW 11.19
Avg. running hrs,/day 8
Energy charges per year= avg. running hrs/dayx.746x17.5x365 per unit 32674.8 9.87 322500.276
fixed charges per month 12 630 7560
duty charges @6% of energy charge 19350.02
SubTotal b= 349410.296
Total Fixed Cost (I) = 397,410.30
Contractor's profit @ 10% on (II)= 39,741.02
Add GST @ 18% on ( II)= 71,533.85
Total Cost (I) 508685.166
(ii) . BoQ (Fixed Cost) (PWS/SVS) : PWS Srinagar
I. Fixed Costs (PWS/SVS)
(a) Cost of pump operator
1 nos for 365 days per month 48000 1 4000 48000
Sub Total a= 48000
(b) Cost of energy charges
Capacity of motor pump say 12.50 HP=(.746x12.5=13.055 kW) kW 9.325
Avg. running hrs,/day 8
Energy charges per year= avg. running hrs/dayx.746x17.5x365 per unit 27229 9.87 268750.23
fixed charges per month 12 630 7560
duty charges @6% of energy charge 16125.02
SubTotal b= 302435.25
Total Fixed Cost (I) = 350,435.25
Contractor's profit @ 10% on (II)= 35,043.52
Add GST @ 18% on ( II)= 63.078.34
Total Cost (I) 448557.11
(iii). BoQ (Fixed Cost) (PWS/SVS) : PWS Dagarua
I. Fixed Costs (PWS/SVS)
(a) Cost of pump operator
1 nos for 365 days per month 48000 1 4000 48000
Sub Total a= 48000
(b) Cost of energy charges
Capacity of motor pump say 7.5 HP=(.746x7.5= 5.60 kW) kW 5.6
Avg. running hrs,/day 10
Energy charges per year= avg. running hrs/dayx.746x17.5x365 per unit 22688.4 9.72 220334.3451
fixed charges per month 5.6 12 630 42298.2
duty charges @6% of energy charge 13220.060706
SubTotal b= 275852.6058
Total Fixed Cost (I) = 323,852.61
Contractor's profit @ 10% on (II)= 32,385.26
Total Cost (I) 414,531.34
(iv). BoQ (Fixed Cost) (PWS/SVS) : PWS Rauta
I. Fixed Costs (PWS/SVS)
(a) Cost of pump operator
1 nos for 365 days per month 48000 1 4000 48000
Sub Total a= 48000
(b) Cost of energy charges
Capacity of motor pump say 25 HP=(.746x25= 18.65kW) kW 18.65
Avg. running hrs,/day 10
Energy charges per year= avg. running hrs/dayx.746x25x365x1.11 per unit 75560.475 9.72 734447.817
fixed charges per month 18.65 12 630 140994
duty charges @6% of energy charge 44066.87
SubTotal b= 919508.68602
Total Fixed Cost (I) = 967,508.69
Contractor's profit @ 10% on (II)= 96,750.87
Total Cost (I) 1,238,411.12
GOVERNMENT OF BIHAR
Public Health Engineering Department
Bill of Quantity 1 (Variable Cost)
S.N. Description Quantity Unit Rate Total Amount
1A Construction of 150mm X100mmx 125m deep T/W etc. all complete and as per direction of E/I.(As per sub Estimate no.- 1) 1 Nos. Rs.294,314.73 Rs.294,314.73
1B Construction of 150 mmX90m deep drilled T/W etc. all complete and as per direction of E/I. 1 Nos. Rs.180,147.69 Rs.180,147.69
2 Constructing masonry Chamber 100x100x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Tube Well, and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , necessary excavation, foundation concrete 1:2:4(1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand) 12 mm thick with 5% cico fnished with a floating coat of neat cement, out side plastering with cement mortar 1:4 (1 cement : 4coarse sand) 12 mm thick complete as per standard specifications & direction of E/I. (As per sub Estimate no.- 2) 1 Nos. Rs.15,314.08 Rs.15,314.08
3A Supply Installation, commissioning and testing of single phase 3 H.P submersible pump set having discharging capacity 3.35 lps at a total head of 35 meter(approx) of different capacity of KSB/ Kirloskar or equivalent make with all accessories & fittings such as 7.5KVA Stabalizer, cable, panel board etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & commissioning as per standards specifications and direction of E/I. (As per sub Estimate no.- 3a) 1 Nos. Rs.110,628.00 Rs.110,628.00
3AA Supply Installation, commissioning and testing of single phase 3 H.P submersible pump set only having discharging capacity 3.35 lps at a total head of 35 meter(approx) of different capacity of KSB/ Kirloskar or equivalent make with all accessories & fittings etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & commissioning excluding the cost of GI pipes for lowering and cables etc. as per standards specifications and direction of E/I. (As per sub Estimate no.- 3a items) 1 Nos. Rs.25,000.00 Rs.25,000.00
3B Supply Installation, commissioning and testing of single phase 2 H.P submersible pump set having discharging capacity 2.25 lps at a total head of 35 meter(approx) of different capacity of KSB/ Kirloskar or equivalent make with all accessories & fittings such as 7.5KVA Stabalizer, cable, panel board etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & commissioning as per standards specifications and direction of E/I. (As per sub Estimate no.- 3b) 1 Nos. Rs.68,220.60 Rs.68,220.60
3BB Supply Installation, commissioning and testing of single phase 2 H.P submersible pump set having discharging capacity 2.25 lps at a total head of 35 meter(approx) of different capacity of KSB/ Kirloskar or equivalent make with all accessories & fittings etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & commissioning excluding the cost of GI pipes for lowering and cables etc. as per standards specifications and direction of E/I.(As per sub Estimate no.- 3B items) 1 Nos. Rs.20,000.00 Rs.20,000.00
3C Supply Installation, commissioning and testing of three phase 5 H.P submersible pump set including light wiring, power wiring and extension of over head L.T line from nearest point of electric line up to pump room having 50 C/sec. 2900 rpm at a total head of 35 meter(approx) of different capacity of KSB/ Kirloskar or equivalent make with all accessories & fittings etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & commissioning complete set as per standards specifications and direction of E/I. (As per sub Estimate no.- 3c) 1 Nos. Rs.140,107.73 Rs.140,107.73
3CC Supply Installation, commissioning and testing of three phase 5 H.P submersible pump set only having 50 C/sec. 2900 rpm at a total head of 35 meter(approx) of different capacity of KSB/ Kirloskar or equivalent make with all accessories & fittings etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & commissioning excluding the cost of GI pipes for lowering and cables etc. as per standards specifications and direction of E/I. 1 Nos. Rs.40,000.00 Rs.40,000.00
4a Providing & Fixing BIS approved 3 HP submersible motar starter all complete as per direction of engineer in charge. (As per sub Estimate no.- 4a) 1 Nos. Rs.5,478.72 Rs.5,478.72
4b Providing & Fixing BIS approved 2 HP submersible motar starter all complete as per direction of engineer in charge. (As per sub Estimate no.- 4b) 1 Nos. Rs.4,741.20 Rs.4,741.20
4c Providing & Fixing BIS approved 5 HP submersible motar starter all complete as per direction of engineer in charge. (As per sub Estimate no.- 4c) 1 Nos. Rs.6,321.60 Rs.6,321.60
5a Supply & Installation of 90-220 V range single phase7. 5 KVA automatic voltage stabilizer make- Sen & Pandit/ Vertex/ISI marked Stabilizer of reputed make. (As per sub Estimate no.- 05) 1 Nos. Rs.26,340.00 Rs.26,340.00
5b Supply & Installation of 90-220 V range single phase 5.0 KVA automatic voltage stabilizer make- Sen & Pandit/ Vertex/ISI marked Stabilizer of reputed make. (As per sub Estimate no.- 05) 1 Nos. Rs.21,072.00 Rs.21,072.00
6A Providing and Laying Distrbution network of 90 MM High Density Polyethylene pipe (HDPE pipe) all complete as per direction of E/I. (As per sub Estimate no.- 6A ) * 1 per m 794.94 Rs.794.94
6B Providing and Laying Distrbution network of 75 MM High Density Polyethylene pipe (HDPE pipe) all complete as per direction of E/I. (As per sub Estimate no.- 6B ) * 1 per m 649.30 Rs.649.30
6C Providing and Laying Distrbution network of 63 MM High Density Polyethylene pipe (HDPE pipe) all complete as per direction of E/I. (As per sub Estimate no.- 6C ) * 1 per m 552.30 Rs.552.30
6D Providing and Laying Distrbution network of 50 MM High Density Polyethylene pipe (HDPE pipe) all complete as per direction of E/I. (As per sub Estimate no.- 6D ) * 1 per m 439.05 Rs.439.05
6E Providing and Laying Distrbution network of 40 MM High Density Polyethylene pipe (HDPE pipe) all complete as per direction of E/I. (As per sub Estimate no.- 6E ) * 1 per m 395.10 Rs.395.10
7a Cost of replacement of riser / delivery pipe by 50 mm dia G.I.Pipe from T/well to PVC Tank 1 per m Rs.603.29 Rs.603.29
7b Cost of replacement of riser / delivery pipe by 65 mm dia G.I.Pipe from PVC Tank to Distribution main 1 per m Rs.703.49 Rs.703.49
7c Cost of replacement of riser / delivery pipe by 80 mm dia G.I.Pipe for wash out 1 per m Rs.862.06 Rs.862.06
7d Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end). 80mm dia Pipe 1 Job Rs.2,347.00 Rs.2,347.00
7e Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end). 50mm dia Pipe 1 Job Rs.925.27 Rs.925.27
7f Supplying all materials labours & fixing 50mm dia. G.I pipe for using as filling station etc. All as per direction of E/I. 1 Job Rs.3,756.61 Rs.3,756.61
8 Estimate for supply & installation of water storage tank (5000 Ltr. =5000 X 1) as per direction of engineer in charge. (As per sub Estimate no.- 08) 1 Job Rs.55,840.80 Rs.55,840.80
9 Installation of Electronically Regulated Doser type chlorinator using Sodium Hypo Chlorite (Hypo NaOCl) (As per sub Estimate no.-09) 1 Nos. Rs.24,775.40 Rs.24,775.40
10 Providing and erecting 8M high staging with ladder of ISA65x65x6 and 16mm dia MS bar as trade @ 400mm c/c and GI enclosure to house electric switch panel & treatment unit (where required) of suitably designed MS section of angle, channel, etc. as per drawing attached. (As per sub Estimate no.-10) * 1 Job Rs.734,253.84 Rs.734,253.84
11 Estimate for Painting of 8M Steel Staging all complete as per direction of engineer in charge. (As per sub Estimate no.- 11) 1 Job Rs.21,282.72 Rs.21,282.72
12a Estimate for Providing GI enclosure to house electric switch panel for steel structure staging all complete. (As per sub Estimate no.- 12) * 1 per m2 Rs.1,581.77 Rs.1,581.77
12 b Repair/ Replacement of M.S angle / channel / Roof Sheet including riveted/ welded/bolted in built up sections, trusess and framed work, including cutting,hoisting,fixing in position and applying a priming coat of approved primer all complete 1 per Kg Rs.109.57 Rs.109.57
13a Estimate for Construction of floor of staging etc. all complete as per direction of engineer in charge. (As per sub Estimate no.- 13) * 1 per m2 Rs.1,625.51 Rs.1,625.51
14 Providing ladder in staging including all accessories etc. all complete. (As per sub Estimate no.- 14) 1 Job Rs.13,148.93 Rs.13,148.93
15 Providing New house connection for each house hold including supplying all materials, labours, tools and making ferrule connection with 20 mm dia MDPE and 15mm G.I Pipes with all fittings etc all complete. (As per sub Estimate no.- 15) 1 Each Rs.2,623.46 Rs.2,623.00 5000
15a Providing New house connection without retrofitting for each house hold including supplying all materials, labours, tools and making ferrule connection with 20 mm dia MDPE and 15mm G.I Pipes with all fittings etc all complete. (As per sub Estimate no.- 15a) 1 Each Rs.2,197.00 Rs.2,197.00
16 Repairing of House Connection (As per sub Estimate no.- 16) 1 Nos. Rs.801.79 Rs.801.79
16A Repairing of House Connection with leakage at ferrule (As per sub Estimate no.- 16A) 1 Nos. Rs.1,495.06 Rs.1,495.06
16B Minor repairs to House Connection (As per sub Estimate no.- 16B) 1 Nos. Rs.191.76 Rs.191.76
17 Replacing of damage Bib cock with New Bib cock (As per sub Estimate no.- 17) 1 Nos. Rs.115.90 Rs.115.90
18 Repairing of 3 HP/2 HP Pump Motor (As per sub Estimate no.- 18) 1 Nos. Rs.9,355.97 Rs.9,355.97
18b Repairing of 5 HP Pump Motor (As per sub Estimate no.- 18b) 1 Nos. Rs.16,583.66 Rs.16,583.66
19 Repairing of Starter (As per sub Estimate no.- 19) 1 Nos. Rs.1,580.40 Rs.1,580.40
20 Repairing of Stabilizer (As per sub Estimate no.- 20) 1 Nos. Rs.3,160.80 Rs.3,160.80
21 Supplying & fitting 2.5 mm2 copper service cable from power point from nearest source up-to pumping station. (As per sub Estimate no.- 21) 1 per m Rs.136.97 Rs.136.97
22 Cleaning of one 5000 Ltr capacity overhead pvc tank and getting water quality tested from departmental lab. (As per sub Estimate no.- 22) 1 Nos. Rs.526.80 Rs.526.80
23A Repairing of Leakages in HDPE Pipe line with PCC cutting & Restoration. (For HDPE Laid at depth 0.5 to 1.0 m)(As per sub Estimate no.- 23) 250 5 10 12500
90 mm Dia 1 Nos. Rs.1,671.01 Rs.1,671.01
75 mm Dia 1 Nos. Rs.1,652.04 Rs.1,652.04
63 mm Dia 1 Nos. Rs.1,596.20 Rs.1,596.20
50 mm Dia 1 Nos. Rs.1,563.54 Rs.1,563.54
40 mm Dia 1 Nos. Rs.1,536.15 Rs.1,536.15
23B Repairing of Leakages in HDPE Pipe line without PCC cutting & Restoration.(For HDPE Laid at depth 0.5 to 1.0 m)(As per sub Estimate no.- 23)
90 mm Dia 1 Nos. Rs.1,262.21 Rs.1,262.21
75 mm Dia 1 Nos. Rs.1,243.25 Rs.1,243.25
63 mm Dia 1 Nos. Rs.1,187.41 Rs.1,187.41
50 mm Dia 1 Nos. Rs.1,154.75 Rs.1,154.75
40 mm Dia 1 Nos. Rs.1,127.35 Rs.1,127.35
24A Repairing of Leakages in HDPE Pipe line with PCC cutting & Restoration. (For HDPE Laid at depth 0.0 to 0.5 m)(As per sub Estimate no.- 24)
90 mm Dia 1 Nos. Rs.1,590.94 Rs.1,590.94
75 mm Dia 1 Nos. Rs.1,571.97 Rs.1,571.97
63 mm Dia 1 Nos. Rs.1,516.13 Rs.1,516.13
50 mm Dia 1 Nos. Rs.1,483.47 Rs.1,483.47
40 mm Dia 1 Nos. Rs.1,456.08 Rs.1,456.08
24B Repairing of Leakages in HDPE Pipe line without PCC cutting & Restoration.(For HDPE Laid at depth 0.0 to 0.5 m)(As per sub Estimate no.- 24)
90 mm Dia 1 Nos. Rs.1,182.14 Rs.1,182.14
75 mm Dia 1 Nos. Rs.1,163.17 Rs.1,163.17
63 mm Dia 1 Nos. Rs.1,107.33 Rs.1,107.33
50 mm Dia 1 Nos. Rs.1,074.67 Rs.1,074.67
25 Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. (Rate Chattisgarh SOR 34.20.107 Rs.121.00+18% GST) 1 m Rs.127.49 Rs.127.49 7500
26 Replacing damaged portion of riser and delivery pipe 8 meter staging with CPVC / UPVC pipe and providing gun metal Gate valve. (Sub Estimate No.26)
Replacing damaged portion 50 mm dia. CPVC / UPVC Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe Replacing damaged portion 50 mm dia. Riser pipe 1 m Rs.833.40 Rs.833.40 1000
Replacing damaged portion 80 mm dia. CPVC / UPVC Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe Replacing damaged portion 80 mm dia. Riser pipe 1 m Rs.1,990.78 Rs.1,990.78
Replacing CPVC / UPVC Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. Replacing Gate Valve 50 mm dia. 1 Nos. Rs.915.00 Rs.915.00 915
Replacing CPVC / UPVC Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. Replacing Gate Valve 80 mm dia. 1 Nos. Rs.2,240.00 Rs.2,240.00 2240
27 Development of Twell. (Sub Estimate No.27) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) 1 Job Rs.16,973.50 Rs.16,973.50
28 Repairing and painting of RCC staging (Sub Estimate No.28) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) 1 Job Rs.75,437.76 Rs.75,437.76
29 Restoration of road for pipeline work having trench size 300 mm. Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) Development of Twell. (Sub Estimate No.11) 1 per meter Rs.362.26 Rs.362.26
30 Providing and fixing 19mm PVC/Block board with KitKat to affix/hang starter, fuses, IoT devices etc all complete as per the directions of the E/I. 1 Job Rs.3,000.00 Rs.3,000.00
31 Providing 50 mm GI pipe for lowering the riser pipe of submersible pump all complete as per the directions of the E/I. (Sub Estimate No.30) 1 Job Rs.1,512.51 Rs.1,512.51
32 Providing and fixing MS clamp consisting of 32mm x 5mm thick two no. rings spaced suitably distance apart around the tank and six nos. L type flats suitably connected with the rings and the other leg suitably connected with the top of the steel structure as per dirction of E/I. 1 Job Rs.3,000.00 Rs.3,000.00
33 Providing and fixixng of New PVC 5000 L Tank Cover with all accessories. 1 Job Rs.300.00 Rs.300.00
34 Providing and fixing M.S Stabiliser Stand near panel Board to keep stabiliser safe. 1 Job Rs.2,500.00 Rs.2,500.00
35 Renovation (Repairing and painting) of Attendent Cum Pump room & toilet. (As per sub Estimate no.- 31) 1 Job Rs.31,613.61 Rs.31,613.61
36 Renovation (Repairing and painting) of Existing Boundry wall of Length 29Mtr and height 1.5Mtr. all complete as per direction of E/I. (As per sub Estimate no.- 32) 1 per meter Rs.1,733.82 Rs.1,733.82
37 Campus development by land filling and brick soaling. (As per sub Est.no.-33) 1 Job Rs.27,302.80 Rs.27,302.80
38 Replacement of Existing Solar driven Pump with Electric driven single phase 2 H.P. submersible pump set having discharging capacity 3 lps at a total head of 45meter (approx) of KSB/ Kirloskar or equivalent make with all accessories & fittings etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & commissioning as per standards specifications and direction of E/I. (As per sub Est. no.- 34) 1 Job Rs.88500.00 Rs.88,500.00
39 Supplying, installation Testing & commissioning of Solar Pannel plate etc all complete as per direction of E/I. (As per sub Est. no.- 35) 1 Job Rs.15,750.00 Rs.15,750.00
40 Supplying, installation Testing & commissioning of Variable Frequency Drive (VFD), Change over Switch and Net Energy Metering (NEM) system (As per sub Est. no.- 36) 1 Job Rs.60,450.00 Rs.60,450.00
41 Providing and Fixing 12 VOLT Solar Battery as per direction of E/I. (As per sub Est. no.- 37) 1 Job Rs.35,000.00 Rs.35,000.00
42 Providing all labours, tools and materials to repair the leakage of different sizes of pipe al different places including earthwork in excavation, opening of joint, dewatering of the trenches, making lead caulked joint & back filling the trenches etc. all complete work (As per sub Est. no.- 38)
(i) without road cutting 1 Nos. Rs.820.00 Rs.820.00
(ii) with Pucca road cutting 1 Nos. Rs.2,006.73 Rs.2,006.73
(i) without road cutting 1 Nos. Rs.890.00 Rs.890.00
(ii) with Pucca road cutting 1 Nos. Rs.2,076.73 Rs.2,076.73
(i) without road cutting 1 Nos. Rs.1,180.00 Rs.1,180.00
(ii) with Pucca road cutting 1 Nos. Rs.2,366.73 Rs.2,366.73
(i) without road cutting 1 Nos. Rs.1,250.00 Rs.1,250.00
(ii) with Pucca road cutting 1 Nos. Rs.2,436.73 Rs.2,436.73
43 Repairing of 63/25 kva transformer inclusing LT pannel rapair in pump house Including Conductor,fuse relay,Timer as required,ST- CTBT pannel repair,Transformer Oil ( 630Ltr) Make-Servo etc all complete as per direction of engineer in charge. 1 Nos. Rs.12,000.00 Rs.12,000.00
44 Providing all labours, materials and cleaning of RCC water VAT from inside and doing chlorination etc. all complete work as per specification & direction of E/I. (As per sub Est. no.- 39) 1 Nos. Rs.1,053.60 Rs.1,053.60
45 Construction of 200 mm x 150 mm x 125 m deep T/W etc. with UPVC Pipe all complete and as per direction of E/I. (as per sub-estimate no.40). 1 Nos. Rs.361,106.00 Rs.361,106.00
46 Construction of 200 mm x 150 mm x 125 m deep T/W etc. with MS Pipe all complete and as per direction of E/I. (as per sub-estimate no.41). 1 Nos. Rs.474,807.00 Rs.474,807.00
47 Construction of 300 mm x 200 mm x 125 m deep T/W etc. with MS Pipe all complete and as per direction of E/I. (as per sub-estimate no.42). 1 Nos. Rs.727,318.15 Rs.727,318.15
48 Construction of 450 mm x 300 mm x 125 m deep T/W etc. with MS Pipe all complete and as per direction of E/I. (as per sub-estimate no.43). 1 Nos. Rs.1,390,348.00 Rs.1,390,348.00
Painting of 10000 Gallon Water Tower. (as per sub-estimate no.44). 1 Nos. Rs.164,266.00 Rs.164,266.00
Painting of 20000 Gallon Water Tower. (as per sub-estimate no.45). 1 Nos. Rs.179,058.00 Rs.179,058.00
Painting of 40000 Gallon Water Tower. (as per sub-estimate no.46). 1 Nos. Rs.243,020.00 Rs.243,020.00
Painting of 50000 Gallon Water Tower (as per sub-estimate no.47). 1 Nos. Rs.312,122.00 Rs.312,122.00
49 Provision of pump operator 1 Nos. Rs.4,000.00 Rs.4,000.00
50 Payment of electricity bills as per actual electricity bills.
Bill of Quantity 2 (Variable Cost)
1 WATER SUPPLY: DUCTILE IRON (DI) SPECIALS
1.1 Providing Ductile Iron Push on special confirming to IS 9523:2000
1.1.1 100mm diameter 11.25⁰ Each 1366.00
1.1.2 100mm diameter 22.50⁰ Each 1464.00
1.1.3 100mm diameter 45⁰ Each 2064.00
1.1.4 100mm diameter 90⁰ Each 1817.00
1.1.5 150mm diameter 11.25⁰ Each 2148.00
1.1.6 150mm diameter 22.50⁰ Each 2207.00
1.1.7 150mm diameter 45⁰ Each 2480.00
1.1.8 150mm diameter 90⁰ Each 3145.00
1.1.9 200mm diameter 11.25⁰ Each 3232.00
1.1.10 200mm diameter 22.50⁰ Each 3396.00
1.1.11 200mm diameter 45⁰ Each 4172.00
1.1.12 200mm diameter 90⁰ Each 5369.00
1.1.13 250mm diameter 11.25⁰ Each 4235.00
1.1.14 250mm diameter 22.50⁰ Each 4622.00
1.1.15 250mm diameter 45⁰ Each 5706.00
1.1.16 250mm diameter 90⁰ Each 7465.00
1.1.17 300mm diameter 11.25⁰ Each 5932.00
1.1.18 300mm diameter 22.50⁰ Each 7077.00
1.1.19 300mm diameter 45⁰ Each 8673.00
1.1.20 300mm diameter 90⁰ Each 11217.00
1.1.21 350mm diameter 11.25⁰ Each 7801.00
1.1.22 350mm diameter 22.50⁰ Each 9197.00
1.1.23 350mm diameter 45⁰ Each 11701.00
1.1.24 350mm diameter 90⁰ Each 16627.00
1.1.25 400mm diameter 11.25⁰ Each 11195.00
1.1.26 400mm diameter 22.50⁰ Each 12825.00
1.2 Providing Ductile Iron(DI) push on specials confirming to IS 9523:2000
1.2.1 400mm diameter 45⁰ Each 16224.00
1.2.2 400mm diameter 90⁰ Each 22716.00
1.2.3 450mm diameter 11.25⁰ Each 13998.00
1.2.4 450mm diameter 22.50⁰ Each 15967.00
1.2.5 450mm diameter 45⁰ Each 20976.00
1.2.6 450mm diameter 90⁰ Each 28788.00
1.2.7 500mm diameter 11.25⁰ Each 16939.00
1.2.8 500mm diameter 22.50⁰ Each 20568.00
1.2.9 500mm diameter 45⁰ Each 28165.00
1.2.10 500mm diameter 90⁰ Each 39127.00
1.2.11 600mm diameter 11.25⁰ Each 25143.00
1.2.12 600mm diameter 22.50⁰ Each 31833.00
1.2.13 600mm diameter 45⁰ Each 41729.00
1.2.14 600mm diameter 90⁰ Each 60864.00
1.3 Providing Ductile Iron push on specials confirming to IS 9523:2000 socketed DI equal tees
1.4 Providing Ductile Iron push on specials confirming to IS 9523:2000 double socketed with flanged branch DI unequal Tees
1.5 Providing Ductile Iron push on specials confirming to IS 9523:2000 all socketed DI unequal Tees
1.6 Providing Ductile Iron push on specials confirming to IS 9523:2000 all socketed DI reducers/tapers
1.7 Providing Ductile Iron push on specials confirming to IS 9523:2000 all DI flanged socketed, DI flanged spigot, MS end plates
1.7.1 D.I. flanged socketed
1.7.2 D.I. flanged socketed 100 mm Each 1543.00
1.7.3 D.I. flanged socketed 150 mm Each 2499.00
1.7.4 D.I. flanged socketed 200 mm Each 3374.00
1.7.5 D.I. flanged socketed 250 mm Each 4978.00
1.7.6 D.I. flanged socketed 300 mm Each 6179.00
1.7.7 D.I. flanged socketed 350 mm Each 8882.00
1.7.8 D.I. flanged socketed 400 mm Each 10778.00
1.8 Providing Ductile Iron push on specials confirming to IS 9523:2000 all DI flanged MJ collar
2 Water supply works
2.1 Removing the GI pipes, cleaning, washing and using at spot or conveying from work site to office/store with all lead and lift i/c removal of all items such as collars, elbows, tees, bends etc,
2.2 Labour charges for laying and jointing GI pipes with earthwork i/c collars, elbows, tees, bends etc. with cuts and threads, white lead paint, conveying the material from store to work site and returning the surplus at store
2.2.1 15mm dia. GI m 10.00
2.2.2 20mm dia. GI m 13.00
2.2.3 25mm dia. GI m 19.00
2.2.4 40mm dia. GI m 24.00
2.2.5 50mm dia. GI m 32.00
2.2.6 65mm dia. GI m 32.00
2.2.7 80mm dia. GI m 32.00
2.3 Cutting charges for CI/DI pipes laid in the ground with necessary tools
2.3.1 100mm dia pipes Each 75.00
2.3.2 125mm dia pipes Each 79.00
2.3.3 150mm dia pipes Each 83.00
2.3.4 175mm dia pipes Each 92.00
2.3.5 200mm dia pipes Each 117.00
2.3.6 225mm dia pipes Each 125.00
2.3.7 250mm dia pipes Each 167.00
2.3.8 300mm dia pipes Each 208.00
2.3.9 375mm dia pipes Each 229.00
2.3.10 400mm dia pipes Each 250.00
2.4 Making cemenr mortar (1:1) and hemp yarn joint for CI pipes i/c cost of all materials viz. cement, sand, hemp, curing for 10 days complete
2.5 Removing CI/DI valves and its tail piece from the pipeline, cleaning, washing, painting and returning the same at store
2.5.1 50mm dia. Each 148.00
2.5.2 80mm dia. Each 250.00
2.5.3 100mm dia. Each 265.00
2.5.4 125mm dia. Each 267.00
2.5.5 150mm dia. Each 339.00
2.5.6 175mm dia. Each 353.00
2.5.7 200mm dia. Each 473.00
2.5.8 225mm dia. Each 491.00
2.5.9 250mm dia. Each 691.00
2.5.10 300mm dia. Each 819.00
2.5.11 375mm dia. Each 828.00
2.5.12 400mm dia. Each 1166.00
2.6 Removing and cleaning CI/DI pipes and specials i/c jointing materials, washing (excluding valves)
2.7 Conveying CI/DI pipes and specials through transportation vehicles
2.7.1 upto 5km i/c loading and unloading qnt 150.00
2.7.2 upto 5km to 10 km excluding loading and unloading qnt 26.00
2.7.3 beyond 10km excluding loading and unloading qnt 16.00
2.8 Fixing DI/CI specials of mechanical jointing of different sizes after setting into the pipeline i/c cleaning, inserting rubber gasket, tightening with bolts & nuts i/c hire charges for T&P, appurtenances and lifting equipments
2.17.1 100mm to 200mm dia. dia. Each 46.00
2.17.2 250mm to 400mm dia. dia. Each 76.00
2.9 Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete
2.9.1 For sluice Valve of 50mm Each 5535.00
2.9.2 For sluice Valve of 80mm Each 10393.00
2.9.3 For sluice Valve of 100mm Each 10884.00
2.9.4 For sluice Valve of 150mm Each 17490.00
2.9.5 For sluice Valve of 200mm Each 28709.00
2.9.6 For sluice Valve of 250mm Each 46491.00
2.9.7 For sluice Valve of 300mm Each 60325.00
2.9.8 For sluice Valve of 350mm Each 93233.00
2.9.9 For sluice Valve of 400mm Each 125367.00
2.10 Providing and fixing Wafer type single flange Butterfly valve conforming to relevant IS 13099/9991 EN GGG40/50 with latest amendments as detailed below of the following diameter and types with TP set and conveying to work site, loading and unloading, stacking etc. with all lead and lift. The rate is inclusive of the cost of valve, TP set, rubber insertion, bolts and nuts and excluding earth work excavation.For PN 10.0 (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.
2.10.1 For sluice Valve of 100mm Each 5849.00
2.10.2 For sluice Valve of 150mm Each 12553.00
2.10.3 For sluice Valve of 200mm Each 13971.00
2.10.4 For sluice Valve of 250mm Each 15374.00
2.10.5 For sluice Valve of 300mm Each 17346.00
2.10.6 For sluice Valve of 350mm Each 23477.00
2.10.7 For sluice Valve of 400mm Each 33092.00
2.11 Providing and fixing of Double Flanged Resilient seated short body Butterfly valves of various dis. As per IS 13095/en 593 with integral DI seat face with approved soft sealing with body and disc of Ductile Iron (DI) of grade GGG-40/50, Body seat & Seal retaining ring of SS 304/CF8, Shaft of stainless steel AISI 410/420/431, Bronze shaft bearing, periferal disk, seal end "o" rings of EPDM, double eccentric disk. Body and disk should be coated with electrostatcially applied epoxy powder coating with a coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, TP set, galvanised bolts and nuts and rubber insertions. For PN 10.0 (All the drilled holes in the body shall be of through holes, no tapped holes will be allowed.) (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete
2.11.1 For Valve of PN 10.0 and 700mm Each 184739.00
2.11.2 For Valve of PN 10.0 and 750mm Each 239773.00
2.11.3 For Valve of PN 10.0 and 800mm Each 265385.00
2.11.4 For Valve of PN 10.0 and 900mm Each 313821.00
2.11.5 For Valve of PN 10.0 and 1000mm Each 407895.00
2.12 Providing & Fixing sluice valves/ Butterfly Valves (labour charges only) conforming to relevant ISS with latest amendments as detailed below for the following diameter and types with two Each of MJ collars, two flanged spigots, conveying to work site, loading, unloading, stacking with appurtenances. with all lead and lifts, aligning, fixing and testing with appurtenances. etc. complete.
2.1.2.1 For sluice valve with accessories - 50mm dia. Each 341.00
2.1.2.2 For sluice valve with accessories - 80mm dia. Each 381.00
2.1.2.3 For sluice valve with accessories - 100mm dia. Each 463.00
2.1.2.4 For sluice valve with accessories - 150mm dia. Each 524.00
2.1.2.5 For sluice valve with accessories - 200mm dia. Each 769.00
2.1.2.6 For sluice valve with accessories - 250mm dia. Each 1167.00
2.1.2.7 For sluice valve with accessories - 300mm dia. Each 1262.00
2.13 Providing and fixing DI MJ specials such as branches and bends suitable for DI K7 and K9 pipes and CI LA class pipes, as per IS 13382 with latest amendments with complete accessories and fixing at site excluding earth work but including loading, unloading, freight charges etc. complete for:
2.13.1 DI MJ specials - Branch 100 x 100mm Each 1701.00
2.13.2 DI MJ specials - Branch 150 x 150mm Each 2673.00
2.38.3 DI MJ specials - Branch 150 x 100mm Each 2322.00
2.38.4 DI MJ specials - Bend 100 x 90 degree mm Each 1203.00
2.38.5 DI MJ specials - Bend 100 x 45 degree Each 1174.00
2.38.6 DI MJ specials - Bend 150 x 90 degree Each 2322.00
2.38.7 DI MJ specials - collar 100mm dia. Each 2287.00
2.38.8 DI MJ specials - collar 150mm dia. Each 4102.00
2.14 Providing, fabricating and fixing at site various diameter MS MJ ends with dummy plates (END CAPS) to suit CI / DI spigots end as per the sketch. The cost is inclusive of all materials, i.e, rubber 'O' rings, flanges, bolts and nuts, dummy plates, consumables, hire charges, tools and welding equipments, lead and lifts, etc. complete as per the instructions of Engineer in charge.
2.14.1 For CI / DI pipes of 100mm dia. Each 1158.00
2.14.2 For CI / DI pipes of 150mm dia. Each 1609.00
2.14.3 For CI / DI pipes of 200mm dia. Each 2226.00
2.14.4 For CI / DI pipes of 250mm dia. Each 3213.00
2.14.5 For CI / DI pipes of 300mm dia. Each 3230.00
2.14.6 For CI / DI pipes of 400mm dia. Each 5077.00
2.15 Providing and fixing of Extension spindle rods,PN 10 /16 suitable for Gate valve of following dia for open and closing application, Extension Spindle lengths shall be available on required sizes as per site conditions, spindle shall be of fixed type, suitable size of MS Square bar epoxy coated, bottom adaptor & Spindle cap (epoxy coated /galvanised) ductile iron Gr40. Protection tube of PVC, Top and Bottom cover / Bottom Connector shall be made by PVC, Bolt shall be made by Zinc coated steel 8.8 Split pin shall be made by Electro galvanized, this set up should help to have a buried application of Gate Valves etc. complete as per the directions of the Engineer-in-Charge.
2.16 Providing & fixing RCC Pre-cast Cover Slab of size 0.8 m x 0.8 m x 0.15m of M25-Design mix concrete with 12 mm steel @ 120 mm c/c both ways, over Gate valve extension spindle with central opening along with lid for smooth operation with appurtenances., complete with all lead and lifts etc. complete Each 2386.00
2.17 Conveying with all lead & lift and fixing C.I/D.I specials, bends, branches, tees,with appurtenances, all sizes and aligning.
2.17.1 50 mm dia to 100 mm dia Each 105.00
2.17.2 125 mm dia to 225 mm dia Each 131.00
2.17.3 250 mm dia to 600 mm dia Each 203.00
3 Attendind leakages
3.1 Providing & fixing CI/DI pipes socket leak repair MJ clamps for attending to leak joints in socket / spigot joints of CI / DI pipes with necessary earth work excavation including using of pneumatic breakers and JCB excavator wherever required and providing DI MJ leak repair clamp, including cost of all materials required for jointing comprising of DI MJ clamps and its accessories such as rubber gaskets made of SBR / EPDM on the socket face, making the socket / spigot joint water tight at the operating pressure, backfilling with available earth and consolidation and bailing out water wherever necessary etc. complete and In all types of road surfaces like Concrete, Asphalt roads etc, for:
3.1.1 CI / DI pipes of 100mm dia. Each 2357.00
3.1.2 CI / DI pipes of 150mm dia. Each 3563.00
3.1.3 CI / DI pipes of 200mm dia. Each 4032.00
3.1.4 CI / DI pipes of 250mm dia. Each 5255.00
3.1.5 CI / DI pipes of 300mm dia. Each 6426.00
3.1.6 CI / DI pipes of 400mm dia. Each 9059.00
3.1.7 CI / DI pipes of 450mm dia. Each 11257.00
3.2 Attending to leaking socket / spigots joints in CI / DI pipes in all types of road surfaces including concrete and asphalt roads, with necessary earth work excavation including using of pneumatic breakers and JCB excavator wherever required for jointing DI MJ clamp and its accessories such as rubber gaskets made of SBR / EPDM on the socket face, making the socket / spigot joint water tight at the operating pressure, backfilling with available earth and consolidation and bailing out water wherever necessary etc.complete.
3.2.1 For CI / DI pipes of 100mm dia. Each 722.00
3.2.2 For CI / DI pipes of 150mm dia. Each 814.00
3.2.3 For CI / DI pipes of 200mm dia. Each 820.00
3.2.4 For CI / DI pipes of 250mm dia. Each 954.00
3.2.5 For CI / DI pipes of 300mm dia. Each 1254.00
3.2.6 For CI / DI pipes of 400mm dia. Each 1289.00
3.2.7 For CI / DI pipes of 450mm dia. Each 1406.00
3.3 Cutting Asphalt /Concrete road surface using machine cutter for leakage pit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. (Work to be carried out as per leak repair manual and the rate includes hire charges of dewatering Pump, tractor, Jeep with all kinds of Labour in a Complete manner). m3 1157 m2 1157.00
3.4 Road Reinstatement of Asphalt /Concrete roads after leak attending with earth work excavation of compacted soil depositing on bank with all lead and lifts including danger lighting and barricading. Providing, laying, spreading and compacting graded stones aggregate as per wet mix macadam specifications. Applying tack coat on granular base such as WBM and WMM surface hot bitumen primer at 4 kg per 10 sqm, heating bitumen in layer to be laid with boiler fitted with spray set of 300 mm thickness. Above laid with bituminous concrete or M20 concrete premixed with bituminous binder at 5.4 to 5.6% of mix and filler, to achieve the desired compaction to give minimum of 45mm thickness compacted. The work shall be carried as per leak repair manual and includes all kinds of materials disposing off the excess excavated Earth with all lead and lifts by vehicle including loading, unloading, labour, HOM of machinery etc. in a complete manner. m2 1690.00
4.1 Providing and laying Ductile Iron pipes of class conforming to IS 8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately) Note: In sewerage projects for internal cement mortal lining ( CML ) of DI pipes, if High Alumina Cement ( HAC ) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement ( SRC ), the cost of pipes may be increased by 5-6% from the prices listed. For DI K7 pipes:
4.1.1 100mm dia pipe m 1460.00
4.1.2 150mm dia pipe m 2016.00
4.1.3 200mm dia pipe m 2576.00
4.1.4 250mm dia pipe m 3140.00
4.1.5 300mm dia pipe m 3968.00
4.1.6 350mm dia pipe m 4999.00
4.1.7 400mm dia pipe m 5976.00
4.2 Labour charges for laying & jointing of DI pipes of all classes rolling and lowering into trenches, laying true to line, level and perfect linking at joints and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of DI pipes and specials (excluding cost of pipes,rubber gasket and specials) with rubber gaskets including cleaning the sockets and spigot ends with saop solutions and applying soft soap to the spigot and socket end before insertion of rubber gaskets, jointing and fixing in perfect conditions including the cost of soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS etc. with all leads and lifts (Earth work excavation in trenches,conveying of materials from stores to be measured and paid for separately) (Contractor will make his own arrangements for procuring water for testing) etc. complete for:
4.2.1 100mm dia pipe m 72.00
4.2.2 150mm dia pipe m 103.00
4.2.3 200mm dia pipe m 150.00
4.2.4 250mm dia pipe m 261.00
4.2.5 300mm dia pipe m 311.00
4.2.6 350mm dia pipe m 339.00
4.2.7 400mm dia pipe m 378.00
4.5 Labour charges for making flanged joints including cost of jointing materials comprising of rubber insertion, galvanised bolts and nuts including giving hydraulic test to the required pressure as per ISS with all lead & lift (contractor will make his own arrangement for procuring water for testing) etc. complete
4.5.1 Pipes and specials of dia 50mm. Each 113.00
4.5.2 Pipes and specials of dia 80mm. Each 124.00
4.5.3 Pipes and specials of dia 100mm. Each 208.00
4.5.4 Pipes and specials of dia 150mm. Each 310.00
4.5.5 Pipes and specials of dia 200mm. Each 334.00
4.5.6 Pipes and specials of dia 250mm. Each 498.00
4.5.7 Pipes and specials of dia 300mm. Each 520.00
4.5.8 Pipes and specials of dia 350mm. Each 707.00
4.5.9 Pipes and specials of dia 400mm. Each 1033.00
4.6 Providing RUBBER JOINTING for CI / DI pipes with rubber gaskets including cleaning the socket and spigot ends with soap solution and applying soft soap to the spigot and socket ends before insertion of rubber gaskets, jacking and fixing in perfect conditions including cost of soap solution, soft soap, waste etc with all lead and lift including cost of jointing materials etc.complete for:
5 RCC Overhead tanks
7.1 Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with:
7.1.1 MS angle of 65 x 65 x 8mm m 4377.00
7.1.2 MS angle of 65 x 65 x 10mm m 4801.00
7.6 Providing, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DI flanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete.
7.6.1 For double flanged CI pipes of 80mm dia. m 2245.00
7.6.2 For double flanged CI pipes of 100mm dia. m 3010.00
7.6.3 For double flanged CI pipes of 150mm dia. m 4808.00
7.6.4 For double flanged CI pipes of 200mm dia. m 6592.00
7.6.5 For double flanged CI pipes of 250mm dia. m 9272.00
7.7 Providing and fixing lightening arrestor with aluminium strip 25mm x 3mm size including finial and grounding, aluminium strip to be embeded in one of the columns in and independent GI conduit of 40mm dia. pipe suitably jointed by collars with all specials with all lead and lifts etc. complete for:
7.7.1 For Over Head Tanks upto 6 M staging Each 8088.00
7.7.2 For Over Head Tanks upto 9 M staging Each 9387.00
7.7.3 For Over Head Tanks upto 12M staging Each 11530.00
7.7.4 For Over Head Tanks above 12M staging Each 13889.00
7.9 Providing, of DI flanged pipe conforming to IS 8329 : 2000 with latest amendments with Cement Mortar Lining (CML) with Portland Slag Cement as per IS 455:1989 and Metallic Zinc Coating as per annexure A of IS 8329 with finishing layer of Bituminous Coating as per Annexure C of IS 8329 and Flanges: Metallic zinc rich epoxy paint & Bituminous Coating, laying true to line and hoisting in position and aligning to correct plumb including cost of jointing material, conveying to work spot with all lead and lifts etc., complete. For PN 10.0
7.11 Providing Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends:
8.2 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to RCC structures like floor and walls of reservoirs, sewe, effluent and water treatment plants, over head tanks, etc. prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry 2 parts water) for horizontal and vertical surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI - 212-3R-2010 ie. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 Bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer in charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal and vertical surfaces in two coats @ 0.70 kg per sqm per coat m2 433.00
9.15 Lowering and laying and fusion welding Jointing for HDPE Pipes Grade PE- 80 / PE-100 conforming to IS 4984-2016, of specified dia. including hydrualic testing and commissioning etc.(Contractor will make his own arrangements for procuring water for testing) for:
11.1 Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.
11.2 For Medium Duty GI pipe:
11.2.6 Medium Duty GI pipe of 50mm dia m 584.00
11.2.7 Medium Duty GI pipe of 65mm dia m 719.00
11.2.8 Medium Duty GI pipe of 80mm dia m 891.00
11.2.9 Medium Duty GI pipe of 100mm dia m 1245.00
11.3 For Heavy Duty GI pipe:
11.3.6 Heavy Duty GI pipe of 50mm dia m 679.00
11.3.7 Heavy Duty GI pipe of 65mm dia m 834.00
11.3.8 Heavy Duty GI pipe of 80mm dia m 1009.00
11.3.9 Heavy Duty GI pipe of 100mm dia m 1412.00
11.4 Providing and fixing GI union in existing GI pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required etc. complete for:
11.4.6 20.88.6: 50 mm nominal bore Each 660.00
11.4.7 20.88.7: 65 mm nominal bore Each 878.00
11.4.8 20.88.8: 80 mm nominal bore Each 1041.00
11.5 Providing lead caulked joints to spun iron or CI pipes and specials with spun yarn and lead, including caulking and giving satisfactory hydraulic test corresponding to the required pressure etc. complete.for:
11.5.1 Spun / CI / DI pipes 80MM Each 481.00
11.5.2 Spun / CI / DI pipes 100MM Each 500.00
11.5.3 Spun / CI / DI pipes 150MM Each 747.00
11.5.4 Spun / CI / DI pipes 200MM Each 944.00
11.5.5 Spun / CI / DI pipes 250MM Each 1210.00
11.5.6 Spun / CI / DI pipes 300MM Each 1425.00
11.6 Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any.
11.6.6 For 50 mm dia GI collar: Each 267.00
11.6.7 For 65 mm dia GI collar: Each 312.00
11.6.8 For 80 mm dia GI collar: Each 421.00
11.6.9 For 100 mm dia GI collar: Each 505.00
11.6.10 For 125 mm dia GI collar: Each 636.00
11.6.11 For 150 mm dia GI collar: Each 695.00
11.7 Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for:
11.7.6 For 50 mm dia GI elbow Each 267.00
11.7.7 For 65 mm dia GI elbow Each 297.00
11.7.8 For 80 mm dia GI elbow Each 417.00
11.7.9 For 100 mm dia GI elbow Each 490.00
11.7.10 For 125 mm dia GI elbow Each 578.00
11.7.11 For 150 mm dia GI elbow Each 651.00
11.8 Supply and delivery at site wrought middle steel (galvanized) GI bend confirming to IS 1239-II, 1991 with latest amendments if any.
11.8.6 For 50 mm dia GI BEND Each 358.00
11.8.7 For 65 mm dia GI BEND Each 404.00
11.8.8 For 80 mm dia GI BEND Each 490.00
11.8.9 For 100 mm dia GI BEND Each 600.00
11.8.10 For 125 mm dia GI BEND Each 680.00
11.8.11 For 150 mm dia GI BEND Each 724.00
11.9 Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any.
11.9.6 For 50 mm dia GI TEE Each 297.00
11.9.7 For 65 mm dia GI TEE Each 373.00
11.9.8 For 80 mm dia GI TEE Each 434.00
11.9.9 For 100 mm dia GI TEE Each 607.00
11.9.10 For 125 mm dia GI TEE Each 775.00
11.9.11 For 150 mm dia GI TEE Each 914.00
11.1 Supply and delivery at site wrought middle steel (galvanized) GI socket confirming to IS 1239-II, 1991 with latest amendments if any.
11.10.6 For 50 mm dia GI socket Each 297.00
11.10.7 For 65 mm dia GI socket Each 373.00
11.10.8 For 80 mm dia GI socket Each 454.00
11.10.9 For 100 mm dia GI socket Each 563.00
11.10.10 For 125 mm dia GI socket Each 614.00
11.10.11 For 150 mm dia GI socket Each 731.00
11.11 Supply and delivery at site wrought middle steel (galvanized) GI plugs confirming to IS 1239-II, 1991 with latest amendments if any.
11.11.6 For 50 mm dia GI Plugs Each 199.00
11.11.7 For 65 mm dia GI Plugs Each 237.00
11.11.8 For 80 mm dia GI Plugs Each 256.00
11.11.9 For 100 mm dia GI Plugs Each 358.00
11.11.10 For 125 mm dia GI Plugs Each 432.00
11.11.11 For 150 mm dia GI Plugs Each 490.00
11.12 Supply and delivery at site wrought middle steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments if any.
11.12.6 For 50 mm dia GI Union Each 267.00
11.12.7 For 65 mm dia GI Union Each 351.00
11.12.8 For 80 mm dia GI Union Each 578.00
11.12.9 For 100 mm dia GI Union Each 622.00
11.12.10 For 125 mm dia GI Union Each 666.00
11.12.11 For 150 mm dia GI Union Each 783.00
11.2 Lowering, Laying and Jointing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) for etc. complete.
Bill of Quantity 3 (Variable Cost)
13 SUBMERSIBLE PUMPSETS AND REPLACEMENT OF PARTS
13.1 Rewinding of submersible pumpset with copper winding wires of appropriate guage, as per specifications and / or directions of the departmental officials, including all materials, labour, equipment and testing. for all types of submersible pumpsets etc.(with guarantee period not less than 6 months) for
13.1.1 For all types of submersible pumpsets upto 3.0 H.P. Each 2710.00
13.1.2 above 3 HP and upto 5.0 H.P. Each 2934.00
13.1.3 above 5.0 HP and upto 5.5H.P. Each 3116.00
13.1.4 above 5.5 HP and upto 6.0H.P. Each 3296.00
13.1.5 above 6.0 HP and upto 6.5H.P. Each 3479.00
13.1.6 above 6.5 HP and upto 7.0H.P. Each 3659.00
13.1.7 above 7.0 HP and upto 7.5H.P. Each 3839.00
13.1.8 above 7.5 HP and upto 8.0H.P. Each 4019.00
13.1.9 above 8.0 HP and upto 8.5H.P. Each 4201.00
13.1.10 above 8.5 HP and upto 9.0H.P. Each 4382.00
13.1.11 above 9.0 HP and upto 9.5H.P. Each 4562.00
13.1.12 above 9.5 HP and upto 10.0H.P. Each 4744.00
13.1.13 above 10 HP and upto 11 H.P. Each 5157.00
13.1.14 above 11 HP and upto 12 H.P. Each 5570.00
13.1.15 above 12 HP and upto 13 H.P. Each 5983.00
13.1.16 above 13 HP and upto 14 H.P. Each 6397.00
13.1.17 above 14 HP and upto 15 H.P. Each 6811.00
13.2 Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and testing etc.(with gurantee of period not less than 1 year) for:
13.2.1 The bowls of same type and make Each 1500.00
13.2.2 The Intermediate piece (IP) with IP leaded bronze brush. Each 1050.00
13.2.3 The Oil Seal. Each 350.00
13.2.4 The Oil Seal.and steel bush Each 250.00
13.2.5 The Guide Vane Each 700.00
13.2.6 The Impeller (Shell moulded with aluminium and bronze.) Each 1500.00
13.2.7 The discharge outlet (DO) bearing DO steel brush DO bearing. Each 2050.00
13.2.8 The steel bearing bush (DO steel bush) Each 400.00
13.2.9 The allen screw Each 1200.00
13.2.10 The pump shaft made out of stainless steel counterless ground with key way (upto 8 stages). Extra for Each stage @ Rs.40/-. Each 1500.00
13.2.11 The pump key (stainless steel) Each 650.00
13.2.12 The pump coupling (stainless steel) Each 1500.00
13.2.13 The Non Return Valve (NRV) assembly complete with rubber 'O' ring. Each 650.00
13.2.14 The cable guard Each 350.00
13.2.15 The strainer Each 450.00
13.2.16 The brass filter Each 1050.00
13.2.17 The Labour Charges for overhauling of the pump set. Each 900.00
13.3 Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and testing etc and wtih guarantee/ warranty for one year for:
13.3.1 The STATOR of motor upto 3 H.P Each 1500.00
13.3.2 The STATOR of motor 3 to 4 H.P Each 2500.00
13.3.3 The STATOR of motor 4 to 5 H.P Each 3500.00
13.3.4 The ROTOR of motor upto 3.0 H.P Each 1200.00
13.3.5 The ROTOR of motor 3 to 4 H.P Each 1500.00
13.3.6 The ROTOR motor 4 to 5 H.P Each 2000.00
13.3.7 The upper flange Each 650.00
13.3.8 The lower flange Each 650.00
13.3.9 upper/ lower housing Each 1200.00
13.3.10 The Lock Ring Each 350.00
13.3.11 The Carbon Housing Each 2000.00
13.3.12 The Carbon Housing (Thrust bearing block assembly complete with segment bearing pad. Each 2200.00
13.3.13 The Carbon Housing (Top carbond / ferrodo padding) Each 350.00
13.3.14 The Stud and Nuts Each 200.00
13.3.15 The Gun Metal bearing, centrifugally cast Aluminium Bronze bearing Each 850.00
13.3.16 The Circlips Each 200.00
13.3.17 The Motor base with pin Each 500.00
13.3.18 The Transportation of pumping machineries Each 1200.00
13.3.19 The Re-errection charges of pumping machineries including overhauling Each 2000.00
13.3.20 The lifting of submersible pumpset from well. Each 1500.00
13.3.21 The Labour charges only for overhauling Each 3000.00
13.3.22 Providing of Thermosetting Plastic i.e., Fibere Glass reinforced polyster sheet moulding compound(SMC) pump house with SMC door & canopy etc...,complete component as directed by the departmental officers. Each 12000.00
13.4 Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete.
13.4.1 0.50 HP/0.37kW - 5 STG(stage) Each 10170.00
13.4.2 0.50 HP/0.37kW - 7 STG(stage) Each 10855.00
13.5 For 0.75 HP/0.55KW
13.11 Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete.
13.11.1 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50" Each 23168.00
13.11.2 3.00 HP - 155 LPM @ 42 m = 7 STG Outlet Dia - 2.00" Each 24334.00
13.11.3 3.00 HP - 135 LPM @ 56 m = 8 STG Outlet Dia - 2.00" Each 25910.00
13.11.4 3.00 HP - 120 LPM @ 55 m = 9 STG Outlet Dia - 2.00" Each 26627.00
13.11.5 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" Each 28113.00
13.12.1 4.00 HP - 360 LPM @ 30 m = 6 STG Outlet Dia - 3.00" Each 22628.00
13.12.2 4.00 HP - 245 LPM @ 42 m = 8 STG Outlet Dia - 2.50" Each 23319.00
13.12.3 4.00 HP - 155 LPM @ 56 m = 9 STG Outlet Dia - 2.00" Each 24107.00
13.12.4 4.00 HP - 135 LPM @ 70 m = 5 STG Outlet Dia - 2.00" Each 24993.00
13.12.6 4.00 HP - 90 LPM @ 88 m = 12 STG Outlet Dia - 2.00" Each 26730.00
13.13.1 5.00 HP - 300 LPM @ 39 m = 5 STG Outlet Dia - 2.50" Each 26310.00
13.13.2 5.00 HP - 245 LPM @ 56 m = 8 STG Outlet Dia - 2.50" Each 27010.00
13.14.1 6.50 HP - 360 LPM @ 45 m = 5 STG Outlet Dia - 3.00" Each 26930.00
13.14.2 6.50 HP - 300 LPM @ 52 m = 6 STG Outlet Dia - 2.50" Each 27813.00
13.14.3 6.50 HP - 245 LPM @ 70 m = 8 STG Outlet Dia - 2.50" Each 29930.00
13.15.1 7.50 HP - 360 LPM @ 60 m = 5 STG Outlet Dia - 3.00" Each 28116.00
13.15.2 7.50 HP - 300 LPM @ 65 m = 6 STG Outlet Dia - 2.50" Each 30010.00
13.15.3 7.50 HP - 245 LPM @ 84 m = 8 STG Outlet Dia - 2.50" Each 32819.00
13.22 Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.
13.23 Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments.
13.23.1 Size 63 mm Each 416.00
13.23.2 Size 80 mm Each 597.00
13.23.3 Size 100 mm Each 654.00
13.24 Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments
13.24.1 Size 50 mm Each 1250.00
13.24.2 Size 65 mm Each 1450.00
13.24.3 Size 80 mm Each 1650.00
13.25 Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments
13.25.1 Size 50 mm Each 1250.00
13.25.2 Size 65 mm Each 1550.00
13.25.3 Size 80 mm Each 1750.00
13.23 Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete.
13.23.1 Upto 3 HP pumps Each 6500.00
13.23.2 3 to 6 HP pumps Each 9550.00
13.23.3 6 to 15 HP pumps Each 15900.00
13.24 for outdoor
13.24.1 Upto 3 HP pumps Each 7500.00
13.24.2 3 to 6 HP pumps Each 10500.00
13.24.3 6 to 15 HP pumps Each 17500.00
13.25 Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. kVAR 550.00
13.26 Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. per 3 poles 1150.00
13.27 Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover)
13.28 Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments m 550.00
13.29 Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets SET 1550.00
13.3 Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark SET 4500.00
13.31 Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. m 40.00
13.32 Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. Job 6500.00
13.33 Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. Job 1350.00
13.34 Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. Job 1450.00
13.35 Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. .
13.35.4 3 x 10 sqmm (suitable for over head mains) m 165.00
13.36 Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. m 135.00
13.37 Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. m 85.00
13.38 Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work.
13.39 Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Job 3750.00
13.4 Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. Discuss
13.40.1 2 HP, Size 65x50 Head 13M, Discharge 462 LPM Each 15610.00
13.40.2 2 HP, Size 50x40 Head 22M, Discharge 186 LPM Each 16993.00
13.40.3 3 HP, size 50x40 Head 30M, Discharge 198 LPM Each 18816.00
13.40.4 5 HP, size 80x65 Head 23.50M, Discharge 600 LPM Each 22310.00
13.40.5 5 HP, size 50x40 Head 46M, Discharge 174 LPM Each 26417.00
13.40.6 7.5 HP, size 100x100 Head 195M, Discharge 1200 LPM Each 30520.00
13.40.7 7.5 HP, size 80x65 Head 195M, Discharge 1200 LPM Each 33619.00
13.40.8 7.5 HP, size 65x50 Head 46M, Discharge 360 LPM Each 35150.00
13.40.9 10 HP, size 80x65 Head 34.50M, Discharge 840 LPM Each 37623.00
13.40.10 12.5 HP, size 100x100 Head 25M, Discharge 1560 LPM Each 38331.00
13.40.11 12.5 HP, size 80x65 Head 40M, Discharge 780 LPM. Each 46710.00
13.40.12 15 HP, size 80x65 Head 44M, Discharge 900 LPM Each 53967.00
13.40.13 20 HP, size 100x80 and 42M, Discharge 1320 LPM Each 65918.00
13.41 Supply and delivery at site brand new best make pressure guage suitable for centrifugal pump confirming to latest IS standards.
13.41.1 pressure guage 80MM Each 597.00
13.41.2 pressure guage 100MM Each 654.00
13.42 Supply and delivery at site brand new best make level guage suitable for centrifugal pump confirming to latest IS standards. Each 750.00
13.43 Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments.
13.43.1 Upto 7.5 HP centrifugal pump Each 9500.00
13.43.2 7.5 to 10 HP centrifugal pump Each 15550.00
13.43.3 10 to 12 HP centrifugal pump Each 35650.00
13.44 Supply, delivery, erection and commissioning at site lighting distribution board suitable for monoblock centrifugal pump confirming with ISI mark and its latest amendments. Each 3500.00
13.45 Supply, delivery, erection and commissioning at site ELCB suitable for monoblock centrifugal pump confirming with ISI mark and its latest amendments. Each 4117.00
13.46 Providing and fixing LT cable of size 4 x 25 Sqm suitable for centrifugal pump sets with ISI mark and its latest amendments. m 562.00
13.47 Supply and delivery at site brand new best make Foot valve suitable for centrifugal pump upto 10HP confirming with ISI mark and its latest amendments. Each 1750.00
13.48 Supply and delivery at site brand new best make Foot valve suitable for centrifugal pump above 12.50HP confirming with ISI mark and its latest amendments. Each 2200.00
13.49 Rewinding of monoblock motor with copper insulaton wire suitable gauge as per ISI specification with all necessary materials and labour,tools and equipments with guarantee period of not less than 12 months
13.49.1 7.5 HP monobloc motor rewinding Job 4000.00
13.49.2 10 HP monobloc motor rewinding Job 6500.00
13.49.3 12.5 HP monobloc motor rewinding Job 8000.00
13.49.4 15 HP monobloc motor rewinding Job 12000.00
13.49.5 20 HP monobloc motor rewinding Job 15000.00
13.49.6 30 HP monobloc motor rewinding Job 20000.00
13.49.7 40 HP monobloc motor rewinding Job 22000.00
13.49.8 50 HP monobloc motor rewinding Job 25000.00
13.49.9 60 HP monobloc motor rewinding Job 35000.00
13.49.10 80 HP monobloc motor rewinding Job 38000.00
13.49.11 100HP monobloc motor rewinding Job 50000.00
13.49.12 120 HP monobloc motor rewinding Job 62000.00
13.49.13 150 HP monobloc motor rewinding Job 65000.00
13.49.14 180 HP monobloc motor rewinding Job 75000.00
13.49.15 200 HP monobloc motor rewinding Job 85000.00
13.5 Providing Ball bearing as per ISI specifiction with guarantee period of not less than 12 months
13.50.1 Bearing cost for 7.5 HP Each 1880.00
13.50.2 Bearing cost for 10HP Each 2050.00
13.50.3 Bearing cost for 12.5 HP Each 2050.00
13.50.4 Bearing cost for 15 HP Each 2550.00
13.50.5 Bearing cost for 20 HP Each 3080.00
13.50.6 Bearing cost for 30HP Each 4050.00
13.50.7 Bearing cost for 40 HP Each 4600.00
13.50.8 Bearing cost for 50 HP Each 6250.00
13.50.9 Bearing cost for 60 HP Each 6500.00
13.50.10 Bearing cost for 80 HP Each 7000.00
13.50.11 Bearing cost for 100 HP Each 7500.00
13.50.12 Bearing cost for 120 HP Each 9000.00
13.50.13 Bearing cost for 150 HP Each 11000.00
13.50.14 Bearing cost for 180 HP Each 12500.00
13.50.15 Bearing cost for 200 HP Each 13500.00
13.51 Providing thrust bearing as per ISI specifiction with guarantee period of not less than 12 months
13.51.1 Bearing cost for 30 HP Each 6500.00
13.51.2 Bearing cost for 40HP Each 7500.00
13.51.3 Bearing cost for 50 HP Each 8500.00
13.51.4 Bearing cost for 60 HP Each 11000.00
13.51.5 Bearing cost for 80 HP Each 13500.00
13.51.6 Bearing cost for 100 HP Each 14000.00
13.51.7 Bearing cost for 120 HP Each 16500.00
13.51.8 Bearing cost for 150 HP Each 18000.00
13.51.9 Bearing cost for 180 HP Each 19500.00
13.51.10 Bearing cost for 200 HP Each 21000.00
13.52 Providing terminal plate as per ISI specifiction with guarantee period of not less than 12 months
13.52.1 terminal plate 7.5 to 12.5 Each 450.00
13.52.2 terminal plate 15 to 30 Each 850.00
13.52.3 terminal plate 40 to 60 Each 1050.00
13.52.4 terminal plate 80 to 120 Each 2000.00
13.52.5 terminal plate 150 to 200 Each 3500.00
13.53 Repairs to Vertical turbine pumps as per ISI specifiction with guarantee period of not less than 12 months V- T Pump
13.53.1 Phosphorous bronze bearing bush for 30 HP to 40 HP Each 4800.00
13.53.2 Phosphorous bronze bearing bush for 50 HP to 60 HP Each 5500.00
13.53.3 Phosphorous bronze bearing bush for 80 HP to 100 HP Each 7500.00
13.53.4 Phosphorous bronze bearing bush for 100 HP to 150 HP Each 8200.00
13.53.5 Phosphorous bronze bearing bush for 180 HP to 200 HP Each 9000.00
13.54 Repairs to Vertical turbine pumps as per ISI specifiction with guarantee period of not less than 12 months V-T PUMP STAGE BUSHES
13.54.1 Phosphorous bronze stage bushes for 30 to 40 HP Each 4500.00
13.54.2 Phosphorous bronze stage bushes for 50 to 60 HP Each 5200.00
13.54.3 Phosphorous bronze stage bushes for 80 to 100 HP Each 7500.00
13.54.4 Phosphorous bronze stage bushes for 100 to 150 HP Each 8500.00
13.54.5 Phosphorous bronze stage bushes for 180 to 200 HP Each 9500.00
13.55 Repairs to Vertical turbine pumps as per ISI specifiction with guarantee period of not less than 12 months V-T PUMP IMPELLER AND NECK RING
13.55.1 IMPELLER AND NECK RING for 30 HP to 40 HP Each 4800.00
13.55.2 IMPELLER AND NECK RING for 50 HP to 60 HP Each 5200.00
13.55.3 IMPELLER AND NECK RING for 80 HP to 100 HP Each 9000.00
13.55.4 IMPELLER AND NECK RING for 100 HP to 150 HP Each 8000.00
13.55.5 IMPELLER AND NECK RING for 180 HP to 200 HP Each 9500.00
13.56 Repairs to Vertical turbine pumps as per ISI specifiction with guarantee period of not less than 12 months HORIZANTAL PUMP
13.56.1 Phosphorous bronze bushes for 7.5 to 15 HP monoblock motor Each 800.00
13.56.2 Phosphorous bronze bushes for 20 HP monoblock motor Each 1800.00
13.56.3 Phosphorous bronze bushes for 40HP to 80HP monoblock motor Each 5800.00
13.56.4 Phosphorous bronze bushes for 100HP to 120HP monoblock motor Each 6500.00
13.56.5 Phosphorous bronze bushes for 150HP to 200 HP monoblock motor Each 8000.00
13.57 BEARING FOR HORIZONTAL PUMP
13.57.1 For 20 HP pump bearing Each 2500.00
13.57.2 For 30 HP Pump bearing Each 3500.00
13.57.3 For 40 to 80 HP pump bearing Each 4500.00
13.57.4 For 60 to 80 HP pump bearing Each 8400.00
13.57.5 For 100 to 150HP pump bearing Each 10200.00
13.57.6 For 180 to 200 HP pump bearing Each 10800.00
13.58 ALL TYPES OF JACK WELL V-T PUMP DETAILS as per ISI specifiction with guarantee period of not less than 12 months -For Pump dismentaling and refitting after attending repairs.
13.58.1 Up to 60 HP Each 10000.00
13.59 For Top body bush fitting
13.59.1 Up to 60 HP Each 2000.00
13.6 For Bottom body bush fitting
13.60.1 Up to 60 HP Each 1450.00
13.61 For Pumps stage body bush fitting Each
13.61.1 Up to 60 HP Each 850.00
13.62 For Pump body necking fitting Each
13.62.1 Up to 60 HP Each 1200.00
13.63 For Impeller breezing making
13.63.1 Up to 60 HP Each 1050.00
13.64 For Pump shaft press throwble
13.64.1 Up to 60 HP Each 680.00
13.65 For Pump open & fitting at work shop
13.65.1 Up to 60 HP Each 3500.00
13.66 For Connecting bush G.M new making Each
13.66.1 Up to 60 HP Each 1875.00
13.67 For Line shaft seat welding making Each
13.67.1 Up to 60 HP Each 450.00
13.68 For Oil inside new Fitting & threading Each
13.68.1 Up to 60 HP Each 1400.00
13.69 For Balancing spaider rubber guide Each
13.69.1 Up to 60 HP Each 1200.00
13.7 For New T.T nipple making
13.70.1 Up to 60 HP Each 3050.00
13.71 For Pump gear box body radial bearing
13.71.1 Up to 60 HP Each 13575.00
13.72 For Gear box ball bearing
13.72.1 Up to 60 HP Each 1500.00
13.73 For Pumping and clean pipe painting
13.73.1 Up to 60 HP Each 1675.00
13.74 For Transportation charges both side
13.74.1 Up to 60 HP Each 2500.00
13.75 Water Treatment Plants HORIZANTAL PUMP ALL TYPES-For Pump open & refitting after repairs
13.75.1 Up to 25HP Each 4900.00
13.76 For Side gland bush
13.76.1 Up to 25HP Each 1500.00
13.77 For Impeller breezing and making
13.77.1 Up to 25HP Each 1100.00
13.78 For Shaft steel welding and making bearing sheet Each
13.78.1 Up to 25HP Each 1100.00
13.79 For Shaft threading making Each
13.79.1 Up to 25HP Each 1250.00
13.8 For Joint rope of 1kg
13.80.1 Up to 25HP Each 700.00
13.81 For Pump shaft bend thrown
13.81.1 Up to 25HP Each 950.00
13.82 For Transportation
13.82.1 Up to 25HP Each 2715.00
13.83 For Pump shaft getting check nut Each
13.83.1 Up to 25HP Each 1050.00
13.84 For Both coupling new set
13.84.1 Up to 25HP Each 8500.00
13.85 Providing and installing of solar photo voltaic (SPV) water pumping system INDUCTION MOTOR, PUMPSETS AND A SUITABLE INVERTER
as per IS specification and instruction of Engineer incharge of work as per IS specification- For 3000 wp/ 3HP submersible with controller
13.85.1 Total head 30 mtrs and shut off dynamic Head 45 mtr and water out put 96000 ltrs/day. Each 267000.00
13.85.2 Total head 50 mtrs and shut off dynamic Head 75 mtr and water out put 57000 ltrs/day. Each 270000.00
13.85.3 Total head 70 mtrs and shut off dynamic Head 100 mtr and water out put 39000 ltrs/day Each 273000.00
13.86 For 4800 wp/ 5HP submersible with controller
13.86.1 Total head 50 mtrs and shut off dynamic Head 70 mtr and water out put 91200 ltrs/day. Each 383000.00
13.86.2 Total head 70 mtrs and shut off dynamic Head 100 mtr and water out put 62400 ltrs/day. Each 386000.00
13.86.3 Total head 100 mtrs and shut off dynamic Head 150 mtr and water out put 40800 ltrs/day. Each 389000.00
13.87 For 6750 wp/ 7.5 HP submersible with controller
13.87.1 Total head 50 mtrs and shut off dynamic Head 70 mtr and water out put 128250 ltrs/day. Each 565000.00
13.87.2 Total head 70 mtrs and shut off dynamic Head 100 mtr and water out put 87750 ltrs/day. Each 568000.00
13.87.3 Total head 100 mtrs and shut off dynamic Head 150 mtr and water out put 57375 ltrs/day. Each 571000.00
13.88 For 9000 wp/ 10HP submersible with controller
13.88.1 Total head 50 mtrs and shut off dynamic Head 70 mtr and water out put 171000 ltrs/day. Each 714000.00 Cable Selection chart for 415 volts, 50 Hz, 3 phase motors (considering Ambient Temp. 50deegre & 3% Voltage Drop)
13.88.2 Total head 70 mtrs and shut off dynamic Head 100 mtr and water out put 117000 ltrs/day. Each 717000.00 MOTOR RATING FULL LOAD CURRENT CABLE SIZE
13.88.3 Total head 100 mtrs and shut off dynamic Head 150 mtr and water out put 76500 ltrs/day. Each 720000.00 LENGTH OF CABLE IN METERS
Cable Size Selection for 3 dia 150 mm submersibles
Cable size recommended for Cable size recommended for Cable size recommended for
Motor HP Starting up to 45 M cable length up to 75 M cable length up to 95 M cable length
35 S/D 2x3x4mm2 2x3x6mm2 2x3x10mm2
30 S/D 2x3x4mm2 2x3x6mm2 2x3x10mm2
25 S/D 2x3x4mm2 2x3x6mm2 2x3x10mm2
20 S/D 2x3x4mm2 2x3x6mm2 2x3x10mm2
17.5 S/D 2x3x2.5mm2 2x3x4mm2 2x3x6mm2
15 S/D 2x3x2.5mm2 2x3x4mm2 2x3x6mm2
12.5 S/D 2x3x2.5mm2 2x3x4mm2 2x3x6mm2
10 S/D 2x3x2.5mm2 2x3x4mm2 2x3x6mm2
7.5 DOL 1x3x2.5mm2 1x3x4mm2 1x3x6mm2
6 DOL 1x3x2.5mm2 1x3x2.5mm2 1x3x4mm2
5 DOL 1x3x1.5xmm2 1x3x2.5mm2 1x3x2.5mm2
4 DOL 1x3x1.5mm2 1x3x2.5mm2 1x3x2.5mm2
3 DOL 2x3x1.5mm2 1x3x2.5mm2 1x3x2.5mm2
Bill of Quantity 4 (Variable Cost)
ELECTRICAL WORKS
19.1 Work of rewinding of HV side upto 100KVA power transformer as specified below: a. Switch off Power supply of transformer Isolator feeder and discharge with discharge rod. b. Disconnect the input and output cables form 100 Kva transformer. c. Drain old transformer oil from transformers, and flush the winding jet force with good BDV valve transformer oil. d. Manually lead up to crane rEach and load to truck to shift factory. e. After rewinding the burnt out HV windings of transformer and replace the gaskets carbonized bolts and Nuts check the necessary tests. f. Fill the new transformer oil (BWSSB Supply) & replace the silica gel breather. g. Re install transformer after received form factory. h. Switch ON power supply and check the transformer, No load and on load. Job 75178.00
19.2 Work of repair and rewinding of LV side upto 100 KVA power transformer as specified below: a. Drain out the contaminated transit oil completely from the reactor; flush the windings of the transformer with jet force of good BDV value transit oil. b. Removing the burnt out windings from all the three phases of the transformer provide new windings of LV side in all three phases. c. Clean the terminal connection with carbon tetra chloride solution. d. Fill the new transit oil (departmental supply) replace the bolts, nuts, washers and provide gasket etc., wherever necessary provide silica gel breather. e. Fix the transformer in the bet and charge the transformer and observe Performance “ON LOAD” and ensure for trueness of the transformer performance. Job 70641.00
19.3 Work of servicing, leak arresting and oil filtration upto 400 KVA power transformers as specified below: a. Removing cable connection of transformer after isolating the supply dismantling the cable connection Job 69540.00
b. Replacing the existing leakage L.V side H.T Busing Gasket, oil seal, bots and nuts etc. of the power transformer. c. Replacing the existing non-functioned damaged Dehydrating Breather by a new breather with new silica gel for the above transformer d. Arresting oil leak from exclusive vent, neutral bushing of valves, flanges, is drying arresting the leakage for L.V and HV side of power transformer and refilling of the transformer oil including cost of labour and necessary repaired materials.
e. Repaint the Transformer using light grey epoxy paint of 2 coated as original. f. Filtering of oil in the transformer at the transformer center by hot process using stream line filter such that the dielectric strength of oil in the transformer conforms to ISI specification. g. Painting of entire structure of transformer yard including fencing using silver paint.
19.4 Work of repairs/servicing and overhauling of on load tap changer (OLTC) of upto 66KV/6.6KV 8MVA transformer as specified below: A). Removing the supply connection of diverter switch draining out the diluted oil of OLTC chamber, removing the diverter switch one by one carefully by using tripped and chain pulley block. Dismantling the moving and fixing contacts and cleaning with good quality cleaning agents to remove the carbon deposit, replacing the worn-out compression spring micros switch tap changing contacts, of worn gear assembly, replacing of worn out bearing oil seals, ‘O’ rings, gaskets, etc., in order to ensure fiction from operations of tap changing and oil leakage from diverter switch mechanism housing resistance by new one which will be supplied by departmentally, cleaning the diverter switch housing chamber to remove the carbon deposit lowering the serviced diverter switch inside the housing chamber and aligning the centre shaft by using lock nut, bolt and washers tighting of resistor conductors carefully without causing damaged to the nearby the contact refilling the good quality high BDV value insulation oil to the diverter switch housing chamber (oil will be supplied by the department adjusting the micro switch NO NC contacts and lifting liver for its proper function and covering the chamber by fixing the lid on the top and cleaning the oil gauge indicator with soap water, after drying refix the same testing the operation of tap changing system by giving upto 440 Volts supply from tap position 1 to 25 after satisfactory charging over of all 25 taps in forward and reverse direction. Job 46977.00
19.5 Work of repairs/servicing and overhauling of on load tap changer (OLTC) of upto 66KV/6.6KV 8MVA transformer as specified below: Painting of transformer including platform CTS etc., with one cost of red oxide to the rusted portion of transformer, 2 coats of M/s grey enamel paint, RYB color paint to CT caps for identification etc., Rates should coat inclusive of cleaning of the transformer of all sizes. Job 28257.00
19.6 Work of repairing of diverter switch and replacement of resistance upto 66KV/6.6KV 8MVA Transformer as specified below: Removing the supply connection of diverter switch draining out the diluted oil of OLTC chamber, removing the diverter switch one by one carefully by using tripped and chain pulley block. Dismantling the diverter switch unit, removing the worn-out resistance from the diverter switch Supply and fixing of new resistance of same capacity as original to the diverter switch without disturbing the other running equipment, cleaning the diverter switch housing chamber to remove the carbon deposit, lowering the repaired diverter switch inside the housing chamber and aligning the centre shaft by using link nut, bolt and washers tighting of resistor conductors carefully without causing damaged to the nearby the contact refilling the good quality high BDV value insulation oil to the diverter switch housing chamber (oil will be supplied by the department) adjusting he micro switch NO, NC contacts and lifting liver for its proper function and covering the chamber by fixing the lid on the top. Testing the operation of tap changing system by giving upto 440 Volts supply from tap position 1 to 25 after satisfactory charging over all 25 taps in forward and reverse direction. Job 75152.00
19.7 Works of Supply fixing and wiring of tap position indicator to RTCC panel transformer as detailed:. Tap position indicator Aux supply: -110V or 230V AC +15% 50HZ, Resistance: - 1 Kilo ohms per step, Tele- transmitter: - 3Wire connection 1 to 99 position, Display: -2Digit 7 segment LED, Accuracy -Tolerance +2%, Type of mounting: -Panel mounting 90x90x70mm, Dimension: -96mm x 96mm x 70mm, Accuracy: -Class 11 Each 20167.00
19.8 Works of Supply fixing and wiring of digital kilowatt meter to RTCC panel upto 5MVA transformer as detailed: Aux supply -606KV -110V OR 230V AC, Range - 0 to 9 KW, Burden - 4VA, Display -3.1/2 digital for nominal full seals, Voltage input -110V from P.T, Mountry -Panel type, Cut out size - 90x90mm, Ambient Emp -0.50degree C, Model Each 17385.00
- DM 3257 ACC.CL:1.0, Accuracy -Class -1.0
19.9 Work of supply, erection and commissioning of indoor upto 250 Amps distribution panel as specified below: Supply, erection and commissioning of Indoor type upto 250 Amps MCCB distribution panel with outgoing copper bus bar, having, accessories like MCCB, incoming and outgoing entry bus bar, ammeter volt meter, ammeter selector switch, LED indication lamp, and with suitable M.S box with required stand unit set. Suitable for Indoor type complete as per latest IS standard specification. Each 68498.00
19.1 Work of supply and fixing of 85W, LED high way fitting to top of panel board, soft starter and breaker as specified below: Providing High pressure high way 85W LED fitting die cast aluminum canopy with aluminum housing to control gear, finished stove enamel gray glassy white canopy interior with a pair of anodized aluminum reflectors clear acrylic bowl, gasket lining for dip inseat resistance duly wired with single or multi LEDS. Each 18560.00
19.11 Work of supply and fixing of isolator panel and capacitor panel fuses to motor. as specified below: A) Removing the damaged burnt out fuses upto 63Amps 7.2 /11 K.V isolator fuses form isolator panel for motor cleaning the fuse carriers with CTC and apply petroleum jelly for fuse contacts and rectify the faulty in the isolator panel. Supply and fixing new fuses upto 7.2/11 K.V isolator fuses to the fuse carrier and checking its working. B) Removing the damaged burnt out fuses upto 30Amps Each 15062.00
7.2/11 K.V capacitor fuses form capacitor panel of motor cleaning the fuse carriers with CTC and apply petroleum jelly for fuse contacts and rectify the faulty in the isolator panel. Supply and fixing new fuses upto
7.2/11 K.V capacitor fuse to the fuse carrier and checking its working
19.12 Work of repairing and servicing of capacitor isolator panel of motors as specified below: A) Dismantling the closing and tripping mechanism, removing the broken, closing lever, cylinder, moving contact tips, and service the entire mechanism, Providing and fixing the new closing lever full set cylinder, moving contact tips, etc., check the electrical circuit, Job 34231.00
replacement of burnt out LED Indication lamps etc., finally the panel should be tested for its running satisfactorily. B) Draining out contaminated breakdown oil completely form reactors, flushing of windings in the reactors with jet force of good BDV. Value transformer oil, cleaning of windings and flushing of carbon deposition over the windings in all the three phase of reactors, removing the terminals and cleaning the terminal bushings with carbon tetrachloride solution, checking of resistance of the windings of the correct value in all the three phases, filling the new oil with break down voltage value.
19.13 Work of replacement of faulty control components and modification and rewiring of soft starter panel upto 1250KW/6.6KV motor as specified below: a. Disconnecting the power cables and control cables. b. Removal of faulty control components and cable disconnections. c. Supply and fixing Auxiliary contractors, upto 110Volt DC coil Supply with 2 NO, 2NC. d. Supply and fixing of Electronic Timers, 24 Volt AC Range 0 to 30 seconds. e. Supply and fixing of MCBs, 2 pole, 10A. f. Supply and fixing of suitable color LED indication Bulbs and reset Push Buttons Red in color. g. Supply and fixing of temperature Scanner. Along with RTDs Job 69031.00
3.5 Mtr Each. h. The necessary tapping/drilling work has to be done for fixing the above components and rewiring to be done etc., i. Testing the soft starter with above supplied components. j. Commissioning the soft starter and handing over the system to department.
19.14 Work of supply and fixing of 40 amps star delta panel Boards upto 15Hp backwash pump motor as specified below: a. Supply and fixing of new upto 15 Hp star delta starter panel board for back wash motor with the following materials. b. Power connector upto 40 A. c. On delay, off delay automatic timer. d. Over current relay upto 20-60 amps e. Upto 10 amps MCB 3 Pole for control circuit. f. Contactor 2 No+ 2 Nc upto 25 amps g. Single phase preventer. h. On and off push button switch. Job 33727.00
i. LED indication lamps RYB motor on, off and trip. j. 0 to 600 volts meter upto 96/96 mm. k. Amps meter C.T Ratio upto 100/5A. l. Current Transformer for metering upto 100/5A. m. upto 30mmx10mm Electronic Grad Aluminum bus bar for RYB phases. n. Internal main wiring using upto 95 sq.mm Copper wire. o. Volts and ammeter selector switch.
19.15 Work of overhauling and servicing and repairing of southern switch gear make breakers of motor as specified below: Lowering the breaker from the panel after isolating the supply, draw out the breaker truck from the panel, checking the fixed and moving contacts. Removing the burnt out parts from the breaker. Supply and fixing of new closing assembly, rose contact, copper poker, banana link, lifting awwembly. Checking the mechanical parts such as moving cam, lifting bar assembly, tripping mechanism and closing mechanism of the breaker and servicing the entire breaker. Check the trip and closing coil of the breaker replace the same if required. Replace the oil (Supply by departmentally). The breaker has to be checked in test position after complete servicing for proper operation and satisfaction. Job 75122.00
19.16 Work of repair and servicing of LOCB breakers of motor feeders and spare breakers as specified below: MECHANICAL PORTION: Removing the complete unit breaker mechanism from the breaker without damaging the arc chamber, wiring to be recorded before removing the breaker mechanism. Dismantling the tension spring latching unit etc., inspecting the alignment and rectify the fault in breakers for proper closing and opening cleaning all moving contact finger contact and fixed contact by C.T.C replace the oil by new oil (Oil will be supplied by the departments). ELECTRICAL PORTION: Checking of entire electrical operation of the breaker panel checking ON & OFF circuit, change over scheme replacement of closing coil, tripping coil, closing contactor wiring should be checked as per drawing, damaged wire should be replaced by new one, all the required spare will be supplied by departmentally. The work should be carried out without disturbing other running equipment. Job 18325.00
19.17 Work of repair, overhauling & servicing of southern switch gear breakers of capacitor bank as specified below: Lowering the breaker from the panel after isolating the supply, draw out the breaker truck from the panel, checking the fixed and moving contacts and replace with new contacts wherever necessary. Repair the worn out rose contacts and poker tips. Checking the mechanical parts such as moving cam, lifting bar assembly, tripping mechanism and closing mechanism of the breaker and servicing. Check the trip and closing coil of the breaker. The breaker has to be checked in test position after complete servicing for proper operation and satisfaction Job 33727.00
19.18 Working of repairing and overhauling of upto 800amps as specified below: Complete dismantling of breaker units of upto 800 amps breaker of filter house taking out the fixed and moving contacts of all the poles, cleaning and putting back with necessary lubrication and checking of complete electrical circuit for proper closing and tripping including necessary replacement of ‘V’ bar contact, finger contact, contact tips, arching contact, tripping and closing coil, back housing set, with female contacts, panel fixed contact set including hylem sheet with contacts, gasket and dash pit oil etc., Testing of tripping and closing mechanism in order to ensure easy of operation of the breaker and commissioning of the system as per the standard practice without interruption of power supply. Job 67859.00
19.19 Work of repairing and overhauling of upto 400 amps LT breaker bus coupler as specified below: Complete dismantling of breaker units of 400 amps, breaker of compressor room taking out the fixed and moving contacts of al limbs, cleaning and putting back with necessary lubrication and checking of complete electrical circuit for proper closing and tripping including necessary replacement of V bar contact finger contact, contact tips of arcing, contacts of tripping and closing coil, back housing set, gasket and dash pot oil etc.. Testing and tripping and closing mechanism in order to ensure easy operation of the breaker and commissioning of the system as per the standard practice without interruption of power supply. Job 67859.00
19.2 Work of repair and rewinding of reactor provided to isolator of motor as specified below: A) Drain out the contaminated transit oil completely form the reactor; flush the windings of the reactor with jet force of good BDV value transit oil. B) Removing the burnt out from all the three phased of the reactor provide new windings in all three phases. C) Clean the terminal connection with carbon tetra chloride solution. D) Fill the new transit oil (departmental supply) replace the bolts, nuts, washers and provide gasket etc., wherever necessary provide silica jel breather. Job 68591.00
E) Fix the reactor in the isolator panel and charge the capacitor bank and observe performance “ON LOAD” and ensure for trueness of the reactor performance.
19.21 Work of overhauling and servicing upto 1250KW, 6.6KV, motor as specified below: a. Disconnect the HT/LT, Cable and record motor details take out the motor from bed b. Check alignment and record details c. Check IR values before removing motor. d. De-couple the motor from pump & taken out from removing anchor bolts e. Dismantling motor end shields f. Removing rotor from stator, checking IR values of stator cleaning stator with thinner, and petrol, g. Removing the moisture of stator by using heaters(oven) h. Revarnishing of stator & rotor baking in oven, applying becktol red on windings on both stator & rotor i. Greasing of bearings, j. Assembling of motor k. Checking IR values of motor and recording the same l. Alignment of motors with pump, and commissioning the motor on No-Load and load trial. Job 68006.00
19.22 Cutting of the damaged portion of upto 3x150sq.mm XLPE cable Providing one number of indoor termination kit upto 3x150 sq.mm HT XLPE cable and attending the termination work upto 3x150sq.mm HT cable of Neutral side cable by using upto 150sq.mm copper lugs, self adhesive HT tape, crimping tool, heat shrinkable termination kit and required bolts and nuts etc., and Commissioning the motor on load. The work including the cost of materials, labour charges, taxes and the rebate towards the cost of released materials etc. Job 11574.00
19.23 Supply and brazing of motor end lead cable by using H.T Copper lugs, brazing materials, gas, soldering past, etc as original for all the three phases for motor. Job 33727.00
19.24 Removing the burnt out supporting insulator from motor of main side Supply and fixing of new insulator to same place as original. Job 17406.00
19.25 Removing the burnt out copper flats form all the 3 phases of neutral side motor. Providing. copper flats copper flats to neutral side connection. Re connect the motor end cable & cable connection using bolts nuts and washers etc as original Job 16577.00
19.26 Removing & refixing the pump after repairing of existing horizontal mounting/ monoblock pump with following spares, etc. including aligning of pump with reference to motor & running the pump on load.
19.26.1 Repairs of Booster Pumps Upto 5HP Job 3042.00
19.26.2 Repairs of Booster Pumps 5 HP to 10 HP Job 3682.00
19.26.3 Repairs of Booster Pumps 10 HP to 15 HP Job 5028.00
19.26.4 Repairs of Booster Pumps 15 HP to 20 HP Job 15739.00
19.26.5 Repairs of Booster Pumps 20 HP to 30 HP Job 20811.00
19.26.6 Repairs of Booster Pumps 30 HP to 40 HP Job 25823.00
19.26.7 Repairs of Booster Pumps 40 HP to 50 HP Job 33218.00
19.26.8 Repairs of Booster Pumps 50 HP to 60 HP Job 38077.00
19.26.9 Repairs of Booster Pumps 60 HP to 75 HP Job 48193.00
19.26.10 Repairs of Booster Pumps 75 HP to 100 HP Job 62638.00
19.26.11 Repairs of Booster Pumps 100 HP to 150 HP Job 71454.00
19.26.12 Repairs of Booster Pumps 150 HP to 200 HP Job 85912.00
19.26.13 Repairs of Booster Pumps 200 HP to 250 HP Job 99230.00
19.26.14 Repairs of Booster Pumps 250 HP to 300 HP Job 112712.00
19.26.15 Repairs of Booster Pumps 300 HP to 350 HP Job 126539.00
19.26.16 Repairs of Booster Pumps 350 HP to 400 HP Job 137405.00
19.27 Removing and refixing the 230/415 v 50 hz I phase/III phase suitable capacity suitable speed horizontal foot mounted screen protected drip proof continous rated monoblock/squrrel cage induction motor with F class insulation, class H super enamelled copper wire with as per standards including transportation charges etc.,
19.27.1 Repairs of Booster Motors Upto 5HP Job 4949.00
19.27.2 Repairs of Booster Motors 5 HP to 10 HP Job 6277.00
19.27.3 Repairs of Booster Motors 10 HP to 15 HP Job 9705.00
19.27.4 Repairs of Booster Motors 15 HP to 20 HP Job 16836.00
19.27.5 Repairs of Booster Motors 20 HP to 30 HP Job 25747.00
19.27.6 Repairs of Booster Motors 30 HP to 40 HP Job 30907.00
19.27.7 Repairs of Booster Motors 40 HP to 50 HP Job 36915.00
19.27.8 Repairs of Booster Motors 50 HP to 60 HP Job 44108.00
19.27.9 Repairs of Booster Motors 60 HP to 75 HP Job 54262.00
19.27.10 Repairs of Booster Motors 75 HP to 100 HP Job 70287.00
19.27.11 Repairs of Booster Motors 100 HP to 150 HP Job 96069.00
19.27.12 Repairs of Booster Motors 150 HP to 200 HP Job 117231.00
19.27.13 Repairs of Booster Motors 200 HP to 250 HP Job 142362.00
19.27.14 Repairs of Booster Motors 250 HP to 300 HP Job 164270.00
19.27.15 Repairs of Booster Motors 300 HP to 350 HP Job 192293.00
19.27.16 Repairs of Booster Motors 350 HP to 400 HP Job 224229.00
aoc.json
Purchase Order
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT No-02-O&M PWS AND WLS PUR PHED.pdf
NIT • 1.23 MB
SBD-NIT No-02-O&M PWS AND WLS PUR PHED.pdf
NIT • 1.24 MB
BoQ_NIT No-02-O&M PWS AND WLS PUR PHED.pdf
NIT • 2.80 MB
TechnicalBid_NIT No-02-O&M PWS AND WLS PUR PHED.xls
NIT • 0.05 MB
PapercutingNIT No-02-O&M PWS AND WLS PUR PHED.pdf
NIT • 0.61 MB
SBD-NIT No-02-O&M PWS AND WLS PUR PHED.pdf
NIT • 1.24 MB
TechnicalBid_NIT No-02-O&M PWS AND WLS PUR PHED.xls
NIT • 0.05 MB
BoQ_NIT No-02-O&M PWS AND WLS PUR PHED.pdf
NIT • 2.80 MB
NIT No-02-O&M PWS AND WLS PUR PHED.pdf
NIT • 1.23 MB
Finan_Bid_NIT No-02-O&M PWS AND WLS PUR PHED.xlsx
NIT • 0.39 MB
C3 Corrigendum Letter No-1504Dated-19.05.2026.pdf
Corrigendum • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .