Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC 6 51 OLD POST OFFICE LANE UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹6.2 L+₹21,099.70 (3.53%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/S MAHALUXMI BUILDERS L1 | R C TRADERS L2 |
|---|---|---|---|---|---|
| 1.00 | S& F Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable pole complete all as specified and directed by Engineer-in-Charge | 2 | Each | 32,000 ₹64,000 Lowest | 33,000 ₹66,000 |
| 2.00 | Supply & fixing lightening arrestor, expulsion type consisting of multiple spark gaps in series with one or more non linear resister to limit voltage surge on AC power circuit to interrupt power flow current suitable for outdoor installation and exposed direct to sun with ambient temperature below - 10 degree C to 50 degree C suitable for surge discharge capacity 65 KA, 11000 volts grade conformign to IS-4350 including all fittings, complete all as specified and directed by Engineer-in-Charge | 1 | Set of Three | 2,600 ₹2,600 Lowest | 2,700 ₹2,700 |
| 3.00 | Supply & fixing in replacement switch air break, gang operated, triple pole, mechanically operated suitable for horizontal or vertical mounting, fixed type, mounted on insulator and steel frame with operating mechanism worked from ground level, provided with locking arrangement for operating handle, consisting of MS channel, HT post type insulator, contacts of copper alloy, high pressure, heavy duty contact assembly, operating rod of 25mm dia GI pipe medium grade, drop out expulsion assembly of phases fuses etc conforming to IS:1018 of 1972 with continuous current rating with 15 insulators of current rating upto 400 amps 11000 volts grade, complete all as specified and directed by Engineer-in-Charge | 1 | Each | 14,500 ₹14,500 Lowest | 15,000 ₹15,000 |
| 4.00 | Material & labour for earthing galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including galvanized steel strip 32 mm x 6 mm as earth lead upto equipment by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. complete all as specified and Engineer-in-Charge. | 5 | Each Set | 3,200 ₹16,000 Lowest | 3,300 ₹16,500 |
| 5.00 | Supply & fixing in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised steel strip of 32mm x 6mm to connect earthpit to electrical equipment room, complete all as specified and directed by Engineer-in-Charge | 20 | RM | 95 ₹1,900 Lowest | 100 ₹2,000 |
| 6.00 | Material & labour for earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including earth lead wire 4.0 mm by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr including testing on completion & dismantling of existing earthing, complete all as specified and directed by Engineer-in-Charge | 2 | Each Job | 3,200 ₹6,400 Lowest | 3,300 ₹6,600 |
| 7.00 | Supply & fixing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised wire of 4mm dia to connect earthpit to electrical equipment room, complete all as specified and directed by Engineer-in-Charge | 10 | RM | 10 ₹100 Lowest | 15 ₹150 |
| 8.00 | Supply & fixing disc type insulator porcelain vitreous white, brown or green 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamp for conductor of working pressure 11000 volts, complete all as specified and directed by Engineer-in-Charge | 3 | Each | 465 ₹1,395 Lowest | 470 ₹1,410 |
| 9.00 | S&F Pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete all as specified and directed by Engineer-in-Charge | 3 | Each | 135 ₹405 Lowest | 140 ₹420 |
| 10.00 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified and directed by Engineer-in-Charge | 2 | Each | 3,200 ₹6,400 Lowest | 3,220 ₹6,440 |
Tender Value
Refer Docs
EMD Value
₹11,670
Closing Date
13 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Bhalra
AGE (I) Bhalra CO 56 APO
PROVN OF ELECTRIC CAPACITOR BANK CT PT METER, ENERGY METER AND ALLIED WK AT BANIHAL UNDER AGE (I) BHALRA (NIT No. 55 of 2025-26)
2025_MES_723901_3
AGE (I)/Bhalra- /2025-26 (NIT No. 55 of 2025-26)
Open Tender
Civil Works
Item Rate
180 days
AGE I Bhalra
Please refer tender documents
7 documents required · 7 mandatory
₹500
AGE (I) Bhalra
₹11,670
4 Dec 2025
29 Sept 2025
20 Oct 2025
29 Sept 2025
13 Oct 2025
6 Oct 2025
Amount
S& F Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable pole complete all as specified and directed by Engineer-in-Charge
Supply & fixing lightening arrestor, expulsion type consisting of multiple spark gaps in series with one or more non linear resister to limit voltage surge on AC power circuit to interrupt power flow current suitable for outdoor installation and exposed direct to sun with ambient temperature below - 10 degree C to 50 degree C suitable for surge discharge capacity 65 KA, 11000 volts grade conformign to IS-4350 including all fittings, complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement switch air break, gang operated, triple pole, mechanically operated suitable for horizontal or vertical mounting, fixed type, mounted on insulator and steel frame with operating mechanism worked from ground level, provided with locking arrangement for operating handle, consisting of MS channel, HT post type insulator, contacts of copper alloy, high pressure, heavy duty contact assembly, operating rod of 25mm dia GI pipe medium grade, drop out expulsion assembly of phases fuses etc conforming to IS:1018 of 1972 with continuous current rating with 15 insulators of current rating upto 400 amps 11000 volts grade, complete all as specified and directed by Engineer-in-Charge
Material & labour for earthing galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including galvanized steel strip 32 mm x 6 mm as earth lead upto equipment by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. complete all as specified and Engineer-in-Charge.
Supply & fixing in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised steel strip of 32mm x 6mm to connect earthpit to electrical equipment room, complete all as specified and directed by Engineer-in-Charge
Material & labour for earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including earth lead wire 4.0 mm by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr including testing on completion & dismantling of existing earthing, complete all as specified and directed by Engineer-in-Charge
Supply & fixing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised wire of 4mm dia to connect earthpit to electrical equipment room, complete all as specified and directed by Engineer-in-Charge
Supply & fixing disc type insulator porcelain vitreous white, brown or green 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamp for conductor of working pressure 11000 volts, complete all as specified and directed by Engineer-in-Charge
S&F Pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete all as specified and directed by Engineer-in-Charge
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified and directed by Engineer-in-Charge
Supply and fix cable jointing kit for 1.1 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified and directed by Engineer-in-Charge
Supply and fix 11 KV CTPT metering unit , type outdoor oil cooled , pole mounted , CT Ratio:5/5 A , Burden 10 VA, Class-0.5 S , STC -3 KA/1 Sec and PT Ratio 11KV /110 V, Burden -0.50 VA, Class-0.5 S, insulation -12 KV/28KV all as per IS-2705/1992 and IS-3156/1992 complete all as specified and directed by Engineer-in-Charge
Supply & fix Trivector meter three phase four wire TVM 110 Volt , PTR 11 kv/110 V , 5A class 0.5 S for active and 1 S reactive with water proof box and suitable copper cable for connection from CT PT Unit.
Supply, installation, testing and commissioning sheet metal enclosure out door type, weather proof for Energy Meter Factory fabricated from 3.15 mm thick CRCA sheet, compartmentalized design, suitable for downloading data from meter to AMRI without opening panel with suitable locking arrangements, of size not less than 0.60 x 0.45 x 0.30 mtr including suitable clump fitted to poles as required at site or directed.complete all as specified and directed by Engineer-in-Charge
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive of oneprimer coat, one under coat and one finishing coat of alumn paint.complete all as specified and directed by Engineer-in-Charge
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm. complete all as specified and directed by Engineer-in-Charge
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 50 Sqmm 3.5 core , 1100 volts grade complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foudation of poles/cable,stay assy etc and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr but n.exc 3.0 mtr in depth and getting out soft/loose soil for taking up or laying of cable, foundation of poles, stay etc complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation. complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layers complete all as specified and directed by Engineer-in-Charge
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge
Supply and laying dry river sand laid in trenches as cable cushioning 80mm below and 150mm above the cable and punned to 180mm and covering complete all as specified and directed by Engineer-in-Charge Note: Punned qty will be measured and paid.
S & L brick covering with width equil to length of brick as the mechanical protction to cable with well burned sub class 'B' laid in trenches flat complete all as specified and directed by Engineer-in-Charge
M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for base of foundation of pole / stay including form work etc.complete all as specified and directed by Engineer-in-Charge
Material and labour for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole, including necessary form work complete all as specified and Engineer-in-Charge.
Material and labour for GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and directed by Engineer-in-Charge.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
Material and labour for GI tubing light grade 40mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and Engineer-in-Charge.. (clamps for fixing pipe, nuts, bolts washers shall be measured separately
Supplly, installation & testing Feeder Pillar Box, Kisok outdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA on angle iron 40X40X6mm frame of size and size of panel (1.8 x 1.2 x 0.6 mtr) suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer complete all as specified and directed by Engineer-in-Charge including earth work complete comprising of following : Incoming (a) Bus bar chamber comprising 4 Nos copper strip of size 32 x 6 mm and lenght 600mm each bus bar and having min 10 holes arrangement in each basbar strip. PVC insulated made of copper strip of size suitable for 200A current. PVC sheathed with colour coding. (b) MCCB having current ratings 200 Amps with rupturing cap 25 KA , AC 415 Volts four pole with microprocessor release complete with spreader links. - 01 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, including suitable CTs with secondary current 5A, with display volt, Amp , Frequency, KWH. - 01 No Outgoing : (a) MCCB having current ratings 100 Amps with rupturing cap 16 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links. - 03 Nos. All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation.
Materials and Labour for connection cable from CT/PT Unit to trivector meter, size of cable size 1.5 sqmm x 10 core PVC insulated unsheathed FRLS copper cable complete all as specified and Engineer-in-Charge.. Make Havells
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size complete all as specified and Engineer-in-Charge.
Material and labour for construction of Platform suitable for 100 KVA transformer of size 2.50m x 2.50m with 1.50m clear height from ground level, 1.00m deep foundation, 150 mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation below ground level, 23cm wide brick masonry in CM 1:6 below & above ground level, hollow space to be filled hard core of size not exceeding 63 mm, deposited spread and levelled in layers not exceeding 15cm thickness, watered and well rammed with 100mm thick cement concreate 1:2:4 type B-2 as in Floor/Top of platform, brick surfaces plastered in CM 1:4 including protection with XPM, gate and chain link fencing rail around the platform with angel iron of 40 x 40 x 6mm frame upto 1.00m clear height supports grouted in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in foundation of angle iron including excavation in any type of soil, returning filling in and removal of surplus soil to a distance 50m, complete all as specified and Engineer-in-Charge.
Supply & fix Bus bar Panel, Size:0.8x0.4x0.4 Mtr, Kisok outdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA on angle iron 30X30X4mm frame of size suitable to incorporate following accessories with front opening doors, locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of Bus bar chamber comprising 4 Nos Aluminium strip bus bars PVC insulated made of aluminium strip of size suitable for 200A current. PVC sheathed with colour coding. complete all as specified and Engineer-in-Charge.
R C TRADERS (BID ID -3448924)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .