Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹18 L
EMD Value
₹18,000
Closing Date
17 Jun 2025, 3:00 pmClosed
Executive Officer
Keeranur Town Panchayat Bus Stand Road Kulathur Tk Pudukkottai
School Improvement Grant Construction Of Toilet 10 Nos at Government Girls Higher Secondary School in Keeranur Town Panchayat
2025_DTP_564395_1
191/2025
Open Tender
Civil Works - Buildings
Item Rate
180 days
Keeranur Town Panchayat
Refer Tender Document
1 document required · 1 mandatory
₹0
₹18,000
17 Jun 2025
3 Jun 2025
17 Jun 2025
3 Jun 2025
17 Jun 2025
3 Jun 2025
Amount
Earth work excavation for foundation and depositing on bank with initial lead and lift etc. completely I hard stiff clay, stiff black hard redearth, shales, gravelstony earth and earth mixed with small size boulders and hard gravelly soil etc., compltete as per standard specification (SS20B)
Supplying and filling in foundation and basement with Stone Dust layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 Mix (one part cement, four part Msand and eight part of aggrigate) using 40 mm size ISS HBG metal from approved quarry including cost and conveyance of all materials to site. loading and unloading charges and labour charges for mixing. Laying and curing etc., complete as per TNDSS NO: 28 & VI (S2) VI (S5A) VII standard specifications as directed by Engineer incharge.
Brick Work in Cement Mortor 1:5 Mix (one cement, five Msand) using new best II Class Bricks of size 9 ” x 4 3/8 “x 2 3/4 ” from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications
Foundation Basement
Ground Floor
Supplying and erectioning steel sheet centering and shuttering including necessery supports for plain surface in foundation and basement for RCC roof rectancular or T beams, L beams, lintel and bedblock staircase waist slap and landing beam etc., with all bracing using M.S sheets spaced at 75cm C/C etc., completly complying with standard specifications.
A)For Grade beam
B)(Ground Floor)
C)For Column
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
Up to Basement
Ground Floor
Supplying and fabricating and placing in position of MS or RTS rods for all rainforced works including cost of steel and binding wire and all labour for cutting and fabrication and other incidental charges etc., completly complying with standard specifications.
Ceiling Plastering in cm 1:3, 10mm thick including cost and conveyence all materials to site and all labour charges and incidental charges etc.,completly complying with standard specifications.
Plastering in cm 1:5, 12 mm thick including cost and conveyence all materials to site and all labour charges and incidental charges etc.,completly complying with standard specifications.
Plastering in cm 1:3, 20mm thick including cost and conveyence all materials to site and all labour charges and incidental charges etc.,completly complying with standard specifications.
Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement .
Paving the floor with pre-polished Concrete Anti-Skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg/sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.
Dadooing sides of walls with Glazed tils of size 0.30m x 0.20m x 0.006m including cost and conveyance and all labour and materials complete complying with standard specifications and drawings and as directed by the departmental Engineers.
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
Finishing the top of roof with one course of machine pressed tiles 20 C.m x 20 C.m x 2 C.m size using cement mortor 1:3 mix mixed with 2% by weight of Crude Oil and pointing with Cement Mortor 1:3 mix Cost of all materials and labour charges and brick jelly concrete etc., complete as per standard specifications.
Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam. Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including
White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. -100sq.m S.I.333
Painting the new walls two coats over one coat of priming with best Emulsion paint of approved colour and quality including preparation of surface and finishing neatly etc., complete complying with standard specification and as directed by the department officers etc., complete complying with standard specifications.
Supplying and fixing in position colour glazed INDIAN TYPE WATER CLOSET with 'P' or 'S' trap including cost and conveyance of water closet and labour for fixing including flooring with brick jelly concrete etc., complete
Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelain low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting
Supplying and fixing of 110mm dia PVC /4kgpipes including cost and conveyence of all materials and all other labour charges and incidental charges etc., completly complying with standard specifications.
Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wallwith3mmthickhylumsheetcoverwithTWswitchboxand5AFTswitchandmakinggoodoftheconcealedportionwithsuitablecolourforPVCconcealedlight/fan Point (for electronic regulator) (5 points per coil)-(SD-25)
Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / cormpton / K.like) suitable for in candles cent lamp with 15 W LED Bulb (SD 83)
Supplying and fixing of 4 ft. 40 W tube light flu fitting complete with copper choke and condenser with TW round blow on wall and ceiling with PVC unsheated lead from terminal tube fitting. (SD 88)
Supplying and fixing of M.S. grill of approved design for Gate, doors, windows and ventilaors using necessary mild steel flats for inner and outermembers xhich should be fixed to window frames inclusive of priming coat of best approved quality red oxide primer etc., complete complying with standard specifications.
Supplying and fixing in position best Indian make white glazed earthenware WASH HAND BASIN of 560x406mm with a a pair of C.I. Brackets, 15mm dia C.P. Pillar tap, 32mm G.I. Waster water pipe, 32mm dia C.P. Brass waster coupling, plug with chain, 15mm dia PVC connection, 15mm G.M. wheel valve with ISI mark and necessary G.I. union and G.I. Elbow, including fixing wash hand basin in position with white lead, clamps, teakwood plugs, screws, rubber washer etc., complete without any leakage complying with standard specifications.
Supplying and fixing in position best Bevelled Edge MIRROR of 6mm thick of size 50cm x 40cm fibre glass shelf type with necessary plywood backing and rubber button, chromium plated screws, teakwood plugs, etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing in position best Indian make Aluminium anodised TOWEL RAIL of approved quality and size 60cm long and 20mm dia with brackets of same material including fixing with necessary teak wood plugs C.P. Screws etc., complete as directed by the departmental officers.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
S/F in position of Indian Make White/Colour glazed earthen ware lipped mouth Flat Back Urinal of best approved quality with G.I.Pipe connection to suitable length,32mm bell mouthed P.V.C connection ,15mm dia G.M.Wheel valve,fixing the urinal to the wall in position with necessary T.W.plugs ,clamps,screws, shellac etc.,including dismantling masonry if necessary and redoing the same to original condition ,fixing the 15mm dia. G.I.pipe connection and wheel valve ,painting the pipe with two coats of approved paint over one coat of primer and checked without any leakage complete, complying with standard specifications. - White Colour
C MALATHY (BID ID -1369656)
stage.html
html • 0.02 MB
finance_673801.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .