Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
14 Nov 2026, 6:00 pm5d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Garrison Engineer (M) NAS Arakkonam
Garrison Engineer (M) NAS Arakkonam 631006
ADDITION ALTERATION TO HANGAR LIGHTS IN PEB 04 BUILDING NO P 363 AT INS RAJALI ARAKKONAM
2026_MES_795629_1
8652E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (M) NAS Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer (M) NAS Arakkonam
₹56,000
Yes
24 Oct 2026
24 Oct 2026
16 Nov 2026
24 Oct 2026
14 Nov 2026
7 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old / unserviceable sub main wiring of any size from existing positions including conduit in Hangars at height upto 30 meter including necessary Boom lift / crane etc as per site requirement carefully as directed complete all as specified and directed. | 1,300 | Rm | - | - |
| 2Material & Labour for following submain wiring along with earth wire in and including the suitable size of stove enamelled rigid ERW steel conduit or PVC conduit incl FRLS PVC insulated copper conductor,two run single core cable for phase & Neutral and single run as earth wire in surface/ recessed complete all as specified and directed. Note - Charges of necessary T&P/Boom lift / Crane/Sacffolding etc will be measured and paid seperately. | |||||
| 2.1 | All as per item no-2 here-in-before but 2X2.5 Sqmm for phase & Neutral and 1X2.5 Sqmm as earth wire. (For single light) | 140 | Rm | - | - |
| 2.2 | All as per item no-2 here-in-before but 2X4.0 Sqmm for phase & Neutral and 1X4.0 Sqmm as earth wire. (For two lights) | 390 | Rm | - | - |
| 2.3 | All as per item no-2 here-in-before but 2X6.0 Sqmm for phase & Neutral and 1X6.0 Sqmm as earth wire. (For three lights) | 140 | Rm | - | - |
| 2.4 | All as per item no-2 here-in-before but 2X10.0 Sqmm for phase & Neutral and 1X10.0 Sqmm as earth wire. | 80 | Rm | - | - |
| 3 | Taking down old / unserviceable / burnt LED light fittings of any type / wattage from existing positions in Hangars at height upto 30 meter including necessary Boom lift / crane etc as per site requirement carefully and handover to AGE E/M store yard as directed complete all as specified and directed. | 90 | Each | - | - |
| 4 | Supply , fixing and testing of Energy saving, environment friendly not less than 500W LED Stadium Flood Light suitable for outdoor sports lighting applications. The luminaire shall deliver a minimum 65,000 lumens with a system efficacy of 130 lm/W, operating at a Correlated Color Temperature (CCT) of 5700K and a Color Rendering Index (CRI) greater than 70 Ra. The luminaire shall be available with suitable beam angle as per site condition and shall operate on 220-240V AC, 50Hz supply with a rated input power of 500W ±10%, nominal input current of 2.2A, power factor of ≥0.95, and THD less than 10%. The LED driver shall have an efficiency of ≥85% and provide a minimum LED life of 50,000 hours at L70 lumen maintenance (Ta = 25°C). The luminaire housing shall be constructed from die-cast aluminium with powder-coated finish, incorporating PC modular lenses, and designed for surface mounting. The fixture shall be suitable for operation in ambient temperatures ranging from -10°C to +50°C. Protection features shall include 5kV line-to-line and 10kV line-to-earth surge protection, over-voltage, short-circuit, open-circuit (no-load), and reverse polarity protection. The luminaire shall comply with Class I electrical safety requirements, provide a minimum IP66 ingress protection rating and IK08 impact resistance rating, and conform to
applicable BIS/ANSI tolerances for photometric and electrical performance. The luminaire dimensions shall be
approximately 375 mm × 370 mm × 120 mm (±10 mm) complete all as specified and as directed by Engr-in-charge/GE. Note : 1. Hiring of boom lift/ Crane/ Scaffolding is included in quoted rate. 2. The rate quoted above including neccessary arrangements of T shape supporting arm, nuts, blots, welding works etc. | 40 | Each | - | - |
| 5 | Supply and fix for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve complete all as specified and as directed. | 36 | Each | - | - |
| 6 | Supply and fix for MCB SPN 230 V, 40-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed. | 12 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tenderdocuments8652.pdf
Tender Documents • 1.42 MB
NIT8652.pdf
Additional Documents • 0.47 MB
BOQ_892378.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .