Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC Lowest Tender | |
| 2 | L2₹34.8 L+₹1.9 L (5.70%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹37.5 L+₹4.5 L (13.8%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹38.0 L+₹5.0 L (15.3%)Rejected-Finance | L4 | Rejected-Finance Not lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Jun 2020, 6:00 pmClosed
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
REPAIRS TO FOOTPATH, KERBS, RAILING, CHAINLINK FENCING UNDER AGE B/R-I OF GE HADDO
2020_MES_337180_1
8446/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
D a (i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹80,000
Yes
29 Jun 2020
2 Apr 2020
10 Jun 2020
2 Apr 2020
8 Jun 2020
6 May 2020
2 Apr 2020 - 9 Apr 2020
Amount
Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and as directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons, risers of steps, skirting, dado etc., laid bedded and pointed in any mortar mortarcomplete all as specified and as directed.
Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion, posts embedded in concrete, brick work, masonry etc., and making good disturbed ground complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
Excavating in post holes (or similar holes) in hard/dense soil each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance not exceeding 50 metres and making good disturbed surfaces complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
M&L for hardcore using broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:2:4) type B2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B2 (using 40mm graded stone aggregate) as in mud stops, kerbs, surface channels, drains, benchings and the like complete all as specified and as directed.
M&L for pre-cast reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in cover slabs for drains, man holes etc., using necessary form work set in CM(1:4) including placing the cover slabs after thay are casted, set, cured and tested completely at required locations without causing damage to either slabs or to other existing structures complete all as specified and as directed. NOTE: Reinforcement will be measured and paid separately under relevant items of this BOQ.
M&L for plain cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in lintels upto 1.5m clear span, cills and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified and as directed.
M&L for reinforced cement concrete (1:1½:3) type A1 (using 12.50mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:1½:3) type A1 (using 12.50mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pilaster and buttresses complete all as specified and as directed.
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns etc., for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc., vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for Mild steel CRS/HCRM TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel CRS/HCRM TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for 5 to 10mm dia mild steel round bars cut to length, bent to shape required to be used as stifferners in chain link fencing, fixed independently to angle iron posts conforming to Fe 410 (Gde-E-250) quality 'A' or Fe 290 (Gde-E-165) complete all as specified and as directed.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel framed work such as gates, grills, railings, gratings, etc., with ornamental and intricate design, ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars and similar work conforming to Fe-290 Gde E-165 including portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc., including taking down old damaged steel work complete all as specified and as directed.
M&L for mild steel angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for mild steel galvanised PVC coated chain link fencing, 3mm nominal dia of GI wire, 1.4mm thick PVC coating and average area of aperture 25 Sqcm with weight of chain link not less than 2.0 Kg/Sqm, including line wires, fixed to any type of standards, rails, straining bolts, etc., with provision of binding wire including taking down old damaged chain link complete all as specified and as directed.
S&F mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 30cm long and dia of neck not exceeding 12 mm complete all as specified and as directed.
M&L for stainless steel hollow sections circular/ square/rectangular in shape and any size and thickness, grade AISI-316 type (Austenitic anti-corrosive in nature) as in railings/grills/designer work including post top cap, bottom plate, cutting, bending, seamless welding and fixed in any location including taking down old damaged steel work complete all as specified and as directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and as directed.
M&L for 75mm thick PCC (1:2:4) type B2 (using 40mm graded stone aggregate) as in base of floors complete all as specified and as directed.
M&L for sand (river sand) filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block, glossy finished, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade, made of grey cement and pigments, laid in floors, set and jointed in neat cement slurry and pointed in white/coloured cement to match with colour of tiles complete all as specified and as directed.
M&L for glossy finished chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for heavy duty pavement tiles 30cm x 30cm x 10mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for 20mm thick granite work (of any type and shade as approved) table rubbed and polished as in steps, jambs, pillars, window cills, cooking platforms, wash basin counters and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15mm thick cement mortar (1:4) bedding and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, rounding (chamfering) the edges complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for preparation of old painted surfaces of walls of any description over 10cm girth or width, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of external walls of any description and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of cement based paint over a coat of primer complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of cement based paint after filling the cracks/holes with filler complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls and applying one coat of weather proof antifungal (exterior grade) acrylic emulsion complete all as specified and as directed.
SUBASH FURNITURE SHOP
VINOD CONSTRUCTION
NAWAZ CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .