| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC VILL ATA KAYASTHAN P O VILVA BHOJIPURA BAREILLY 243202 UP | BAREILLY | BAREILLY | UP | 243202 | L1 | Accepted-AOC Being L1 and awarded contract. | |
| 2 | L2₹6.6 L+₹85,170 (14.8%)Rejected-Finance | L2 | Rejected-Finance Not Being L1. | |
| 3 | L3₹6.6 L+₹88,390 (15.4%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L3 | Rejected-Finance Not Being L1. | |
| 4 | L4₹7.3 L+₹1.5 L (26.1%)Rejected-Finance 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | L4 | Rejected-Finance Not Being L1. | |
| 5 | L5₹7.4 L+₹1.6 L (27.9%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L5 | Rejected-Finance Not Being L1. |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
30 Jun 2025, 6:00 pmClosed
AGE (I) R and D Haldwani
AGE (I) R and D Haldwani PO Arjunpur UK 263139
REPAIR/MAINT OF FIRE FIGHTING PUMP SET, FIRE HYDRANT, HOSE BOX, HOSE PIPE, CONTROL VALVE, FIRE ALARM SYSTEM, EQUIPMENT, ETC
2025_MES_712305_1
AGE(I)/RandD/HLD-38 OF 2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
A Cell DIPAS
As per NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) R and D Haldwani
₹15,000
Yes
4 Aug 2025
3 Jun 2025
2 Jul 2025
3 Jun 2025
30 Jun 2025
17 Jun 2025
Amount
Contract Details
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for taking out/for laying under ground cables/pipes etc and getting out any type soil all as dircted
Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm
Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point
Supply and laying common burnt clay building bricks sub class "B" designation 75 old size bricks for cable protection
Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts all as directed by Engr-in-Charge at site Note : - Only punned thickness shall be measured for payment purpose
M&L for servicing/overhauling/repairing of existing defective centrifugal pump of following capacity 60 HP, 3 Phase,415 volts, AC supply and cleaning, oiling/greasing, fixing of serviceable parts in position, oiling/greasing,refixing of serviceable parts in position,balancing, realignment etcreplcement of nut bolt washer where required, welding braging and trasportation to workshop if required, Repair to bearing housing with metling and turning and fixing the same in position and testing on full load complete all as specified and directed. Booster/centrifugal pump of capacity 60 HP (i) Replacement of unserviceable parts if required shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates.
All as per item No 6 but booster/centrifugal pump of capacity 7.5HP,
Taking out & removing old burnt out windings wire of the booster pump / centrifugal pump/ vertical pump electric motors of capacity 60HP, Three phase, 415 Volts, 50 Hz, AC supply including cleaning the slots with carbon- tetra-chloride solution before rewinding and rewinding of electric motors with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates
Taking out & removing old burnt out windings wire of the booster pump / centrifugal pump/ vertical pump electric motors of 5 to 7.5 HP, Three phase, 415 Volts, 50 Hz, AC supply including cleaning the slots with carbon- tetra-chloride solution before rewinding and rewinding of electric motors with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates
Supply only ball bearing No 6308 suitable for pump set of capacity 7.5 HP
Supply only ball bearing No 6308 suitable for pump set of capacity 60 HP
Supply only ball bearing No 6208 suitable for pump set of capacity 7.5 HP
Supply only ball bearing No 6208 suitable for pump set of capacity 60 HP
Supply only gun metal bush suitable for pump set of capacity 4 to 7.5 HP
Supply only gun metal bush suitable for pump set of capacity 60 HP
Supply only CI Impeller suitable for pump set of capacity upto 4 to 7.5 HP
Supply only CI Impeller suitable for pump set of capacity upto 60 HP
Supply only cooling fan blade suitable for pump set of capacity upto 4 to 7.5 HP
Supply only cooling fan blade suitable for pump set of capacity upto 60 HP
S&F flexible rubber coupling of delivery vertcal pipe line of out let of pump set of size 150 mm bore with nut bolt washer etc after diisconnecting and taking out old existing coupling with old nut bolt and washer etc, complete all as directed.
Inspection, tuning, callibration,connecting of cable, rewiring where required from control panel to control switches and other equipment of auto functional system ,detection of fault and rectification, commisioning of main controle panel to make auto functional and testing of complete fire fighting system. Assement of serviceability of all connected equipement of fire fighting system compraising of pump set,motor,pressure tank ,pressure guage ,pressure valve electric controle panel,cable, fire hydrant,hose reel box, vertical duct, controle valves , hoses, rubber reels, syren and measurig equepements to the satisfaction of Eng- in- Charge at DIBER technical area . Minor item like cable upto 1.5 mtr, insulation tape ,marker , lugs ,separater if required will be supply and fixed by contractor, cost of the same is deemed to be included in the item of work.Notes : (i) Replacement of unserviceable parts if required shall be measured and paid for separately under appropriate item of Sch `A` here in after.(ii) Detail inspection/serviciability report will be submitted by the contractor cost of the same is deemed to be included in the item of work all as directed to the satisfaction of E in Charge .
M&L for repair of old existing out door double door hose box doors, locking system and replacement of both existing broken door glasses with existing size complete with rubber beading and denting/welding including painting with two coat of fire red colour enmel paint all as required at site and directed.
M&L for repair of old existing double door duct doors, locking system, hinges and replacement of both door glasses of existing size complete with rubber beading and denting/welding including painting with two coat of fire red colour enmel paint all as directed to the satisfaction of Engr- in -Charge
Supply and fixing of hose box (cabinet) of size 900x900x600mm indoor type made out of 2mm thick MS Sheet with ceter opening glazed doors (4mm thick clear glass) and locking arrangement including painted with to coats of synthetic enamlled paint over a coat of red oxide primer and the word " FIRE" to painted on box, suitable for housing 2 Nos hose pipe of length 15 mtrs each with branch pipe,nozzle,coupling etc all as specified and directed.
Disconnecting and taking out old existing unserviceable pressure switches supply & fix new Industrial Pressure switch universal type of exesting size complete all as directed.
Disconnecting and taking out old existing unserviceable pressure switches supply & fix Pressure gauge 4" dia, 0- 14 Kgs rating gauage of exesting size complete all as directed.
Disconnecting and taking out old existing unserviceable safety relief valve of size 25 mm straight type screwed male end of brass/bronze made and supply & fix new safety release valve of size 25mm of brass/bronze complete with testing and as directed.
Disconnecting and taking out old existing unserviceable ampmeter and supply & fix new digital Amp meter three phase bright LED display 4 digits square type complete with nut bolt and testing and commisioning all as directed. Make Schneider Cat 300461and equivalent
Disconnecting and taking out old existing unserviceable voltmeter supply & fix new anolog volt meter three phase bright 0 to 500 V, square type complete with nut bolt and testing and commisioning all as directed. Make AE and equvalent
Taking out existing defective CI butterfly valve of size 80 mm bore and supply & fix new CI butterfly valves of 80 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.
Taking out existing defective CI butterfly valve of size 100 mm bore and supply & fix new CI butterfly valves of 100 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.
Taking out existing defective stand post hydrants landing valves single control of size 63/65 mm bore and supply & fix new fire hydrant landing valves single control of size 63/ 65 mm bore incl replacement of rubber gasket,etc. all as directed.
M&L for repair of old existing stand post hydrants including painting with two coat of fire red colour enmel paint all as directed to the satisfaction of Engr- in -Charge
Taking out existing defective hose reel drum of 30 mtr length ISI marked complete with nozzle and coupling and supply & fix new hose reel drum of 30 mtr length ISI marked complete incl nozzle and coupling all as specified and as directed.
Taking out existing defective RRL hose type-A 15mtr in length, complete with nozzle and coupling supply & fix new RRL hose type-A 15mtr length ISI marked complete incl brass/ GM nozzle,male and femail coupling and all as specified and as directed.
Taking out existing defective overload relay supply & fix new overload control relay of AC -15 , 4A at 415 V MX0 AC of existing type incl replacement of nuts and bolts etc. as required and all as directed.
Taking out existing defective Contactor for starter and supply & fix new Contactor of size 3 Phase 415 V 9 to 25 Amp incl replacement of nuts and bolts etc. as required and all as directed.
Taking out existing defective single phase preventor supply & fix new single phase preventor three phase incl replacement of nut and bolt etc. all as directed.
Taking out existing defective starter and supply & fix new fully automatic star delta starter AC 415 V, 50 HZ, 3 phase suitable for pump set of capacity Upto 10 HP.
Taking out existing defective starter and supply & fix new fully automatic star delta starter AC 415 V, 50 HZ, 3 phase suitable for pump set of capacity 60 HP.
Taking out old unserviceable power contractor and supply and fix 4 pole power contractor 18A/20A AC, 3 phase rating Suitable for 7.5HP / 5.6 KW AC Motors Suitable for MK 1 Starters 110V AC 50Hz Control Voltage Coil as directed by Engr in Charge.
Supply and fix MCCB 415 volts, 3 phase, 50 Hz, 3 pole of capacity 125 Amps 16 KA including taking down old unseviceable MCCB all as directed by Engr-in-Charge. Make : L&T/Indo asian/ABB/Havells
Supply and fix MCCB 415 volts, 3 phase, 50 Hz, 3 pole of capacity 63 Amps 16 KA including taking down old unseviceable MCCB all as directed by Engr-in-Charge. Make : L&T/Indo asian/ABB/Havells
Supplying and fixing 5 to 32 A rating, Three pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 40 to 63 A rating, Three pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supply and fix in replacement electronic timer 3 to 30 sec 240/415 Volt as required at site type ST 100 of MakeL&T as persample or other equivallant and as directed directed.
Supply and fix water level controller with water level controller probe for draining and filling application 240/415 Volt. Make L&T as per sample or other equivallant make and all as directed.
M& L for supply instalation, testing, commisioning of fire alarm remote response indicator in replacement of existing unserviceable response indicator incl disconnecting, dismantling and taking out existing unserviceable fire remote indicator all as specified and directed.
Fire Alarm sounders / Sirens electronic type horizontal single/two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5 db 500m range in replacement of existing unserviceable fire alarm hooter/sounder incl disconnecting, dismantling and taking out existing unserviceable fire alarm hooter/sounder all as specified and directed
M& L for supply, instalation, testing and commisioning of fire alarm addressable manual call point resettable type incl disconnecting, dismantling and taking out existing unserviceable fire alarm manual call point all as specified and directed.
M& L for supply, instalation, testing and commisioning of addressable type multisensor heat and smoke cmbination detector incl disconnecting, dismantling and taking out existing unserviceable smoke detector all as specified and directed.
Disconnecting and taking out old existing unserviceable LT UG cable of size 10 Sqmm 4 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 10 sqmm, 4 core . complete all as specified and directed.
Disconnecting and taking out old existing unserviceable LT UG cable of size 16 Sqmm 4 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 16 sqmm, 4 core . complete all as specified and directed.
Disconnecting and taking out old existing unserviceable LT UG cable of size 25 Sqmm 3.5 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 25 sqmm, 3.5 core . complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 25 X 4 mm as earth lead in 40 mm dia GI light grade protection pipe including charcoal, salt, bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Supply and install Four Zone Fire Alarm control panel as required at site MakeAgni as persample or other equivallant and as directed directed.
AJA BUILDERS (BID ID -3328432)
M/s Dhapola Elevator and Engineering (BID ID -3333630)
JAGAT POWER ELCTRICAL (BID ID -3332702)
M/S BHATT ENTERPRISES (BID ID -3330821)
om enterprises (BID ID -3334208)
Prime Technology (BID ID -3341951)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .