Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 CrAccepted-AOC | ₹1.2 Cr | 1 | Accepted-AOC Being L-1 |
| 2 | 2₹1.2 Cr+₹3.9 L (3.28%)Rejected-Finance | ₹1.2 Cr+₹3.9 L (3.28%) | 2 | Rejected-Finance Being other than L-1 |
| 3 | 3₹1.3 Cr+₹11.9 L (10.1%)Rejected-Finance 32 06 PEST HOUSE NARONA CHAURAHA MALL ROAD POST BOX NO 49 KANPUR 208001 UP | KANPUR | KANPUR | UP | 208001 | ₹1.3 Cr+₹11.9 L (10.1%) | 3 | Rejected-Finance Being other than L-1 |
| 4 | 4₹1.3 Cr+₹12.1 L (10.2%)Rejected-Finance | ₹1.3 Cr+₹12.1 L (10.2%) | 4 | Rejected-Finance Being other than L-1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Approved |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
24 Jun 2022, 6:00 pmClosed
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Kanpur Pin-208008
SPECIAL REPAIR TO EXISTING RCC ROOFED LIVING IN BILLET AT AFSK KANPUR
2022_MES_524077_1
CA No.CWE(AF)/CHK/BR/T-06 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) B/R Chakeri
Please refer Tender documents
7 documents required · 7 mandatory
₹1,000
GE (AF) B/R Chakeri
₹2.0 L
3 Sept 2022
14 May 2022
27 Jun 2022
14 May 2022
24 Jun 2022
11 Jun 2022
Amount
Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings not exc 15 cm thick, complete all as specified and as directed.
Dismantling of Brick work / stone masonry built in cement mortar complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for complete all as specified and as directed.(reinforcement cut as required to facilitate demolition)
M & L for cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cm 1:4 as in half brick thick wall complete all as specified and directed.
M&L PCC 1:2:4 type B-1 ( using 20 mm graded crushed stone aggregates) as in copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M & L for 75 mm thick cement concrete type C- 2, 1:3:6 ( using 40mm graded aggregate) as in plinth protection complete all as specified and directed.
M & L for cement concrete 1:3:6 type C-2, as in surface channel and drain complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10 mm thick on ceiling surfaces in cement mortar 1:3, finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparing new plastered surface on walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M & L for preparing new plastered surface of wall and applying three coats of white wash complete all as specified and directed.
M & L for preparing new plastered surface and applying three coats of white wash on ceilling complete all as specified and directed.
M & L for preparing old decorated surface and applying one coat of white wash on ceilling, complete all as specified and as directed
M & L for preparing new plastered surface and applying two coats of cement base paint complete all as specified and as directed.
M&L for providing reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in precast manhole covers including necessary form work etc complete all as specified and directed.
M & L for mild steel bars 10 mm dia & over cut to length bent to shape required including,crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, quality confirming to TMT bars complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specially provided for omplete all as specified and as directed.
Excavation for getting out loose brick bat/cinder filling under sunken slab in foul condition (ref preamable 1.14.1 (b) of SSR 2020 Part-II (Rates) complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) mixed with liquid water proofing compound over sunken slab to maintain slope complete all as specified and directed. (Note-WPC shall be measured and paid separately)
M&L rendering 15 mm thick on wall and floor of sunken slab in cm 1:3 mixed with liquid water proofing compound and finished even and smooth without using extra cement complete all as specified & directed on external surfaces. (Note-WPC shall be measured and paid separately)
Supply only liquid water proofing compound complete all as specified and directed.
M & L for two coats of polymeric based chemical coating over plastered surfaces of sunken slab and wall, as per manufacturer's instruction complete all as specified and directed.
M & L for cement concrete 1:5:10 type E-2 (using 40 mm graded brick aggregate) as in mass concrete , complete all as specified and as directed.
M & L for 75 mm thick cement concrete type D- 2, 1:4:8 ( using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for 25 mm thick cement concrete type B- 1, 1:2:4 ( using 20 mm graded stone aggregate) as in sub floor complete all as specified and directed.
S&F GI tubing 25 mm bore medium weight fixed to wall as spout pipe in sunken slab, complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors or in any position complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Granite 18-20mm thick (in black shade) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in, over and including 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M & L for marble work (Green Shade) 18 to 20mm thick (table rubbed and polished) as in floor, steps, jambs, pillars, windowcills, cooking platforms and like over and including 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed.
M&L for non-skid ceramic tiles coloured 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cm 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 450 x 300x 8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces rough finished for receive tiles on vertical surfaces complete all as specified and as directed.
Taking down chowkhats or frames of any description exc 1.5 sqm but not exc. 4 Sqm each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhats or frames of any description not exc 1.5 sqm each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhat or frame of ventilators of any description not exc 1.50 Sqm each complete all as specified and directed.
Taking down shutters of any description exc. 1 sqm but not exc 2 sqm complete all as specified and directed.
S&F pressed steel frames 1.25 mm thick for doors with one/more rebated incl necessary fixing lugs hinges lock strike plate etc compl size 125x60mm and filling with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in back of chowkhat complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm thick wood grain printed PVC sheet & edges will be painted to match with prelam sheet, reinforced with M.S. Square tube fixing in opening complete all as specified and directed.
S&F flush shutters 30 mm thick , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stile and plain colour PVC sheet for top rail , lock rail and bottom rail on either side and as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles & rail with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing to frame at site as per specification complete all as specified and directed.
S & F stainless steel butt hinges medium wt of size 75 mm complete all as specified and directed.
S & F 100 mm long Aluminium handles, cast type, anodised complete all as specified and directed.
S & F 150 mm long Aluminium handles, cast type, anodised complete all as specified and directed.
S&F aluminium alloy, anodised 250 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S & F 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
Supply and fixing openable double shutter steel windows i.e. glazed and gauged with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded joint including PCC (1:3:6) type C-2 filling in back side of frame, complete all as per detail shown on drawing No CE (F)/NGP/2003/TD/08 Sheet No 1/12 to 12/12. NoteL- (i) MS grill shall be measured and paid separately under relevant item. (ii) Wire mesh and glazing including sheet glass shall be measured and paid separately under relevant item.
S & F window guard bars, plain, let in and fixed in steel window of any description, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staple complete all as specified and directed.
S&F Sheet glass ordinary quality 3 mm thick and glazing with oil putty in squares not exc. 0.50 sqm each pane complete all as specified and directed.
S & F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
S & F Sheet glass ordinary quality, frosted on one side, 3 mm thick and glazing with oil putty in squares not exc. 0.50 sqm each pane complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M & L for two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces of any description, not otherwise described over 10cm width or girth including preparation complete all as specified and directed.
M & L for preparation of old steel surfaces of any description exc 10 cm in girth and applying a coat synthetic enamel paint complete all as specified and directed.
M & L for preparation of old wooden surfaces of any description exc 10 cm in girth and applying a coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old surface of wall and applying one coat of distempering of wall with distemper oil emulson (any tint) complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but not exc 2.00 Sqm and refixing the same after necessary cutting of shutter according to FFL complete all as specified and directed.
Roughening surfaces of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc. and brushing with neat cement slurry @ 3 Kg/Sqm , complete all as specified and as directed.
M & L for machine cut kota stone slab flooring 18 to 20 mm thick over and including 15 mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for Kota stone slab 18 to20 mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick plaster in cm 1:4 cement screed and jointed including rubbing and polishing complete all as specified and directed.
S&F in repair vitreous China urinals, half stall type urinal , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed.
S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
S & F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with pattern, size 580 x 440 mm white, with integral foot rests including 100 mm bore cast iron P trap (excluding flushing cistern and flush pipe) complete all as specified and directed.
Excavating in trenches, not exc 1.5 m wide and not exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 sqm on plan and not exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Dismantling of cast iron,PVC or reinforced concrete soil waste and drain pipe, 75/100 mm dia, jointed in cement mortar or lead and taking out of trenches, complete all as specified and directed.
S&F cast iron (sand cast ) soil ,waste and vent pipe 100 mm dia in any length with or without ears fixed in trenches or in floors with cement joint complete all as specified and directed.
S&F cast iron (sand cast ) soil ,waste and vent pipe 100 mm dia in any length with or without ears fixed on wall with cement joint complete all as specified and directed.
S&F in repair cast iron P or S trap 100 mm bore complete all as specified and as directed.
S&F CI branch pieces 100 mm bore, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F CI bends 100 mm bore (any radius), diminishing pieces or tapers with oval acess door , complete all as specified and as directed.
S&F CI bends 100 mm bore (any radius), with duck 's foot or heel rest, complete all as specified and as directed.
Supply and fix in repair cast iron vent cowl 100 mm complete all as specified and directed.
S&F PVC (SWR) 100 mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) 75mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) 75mm dia pipes single socketed, in any length with rubber ring joints, laid in on wall complete all as specified and directed.
S&F PVC (SWR) plain floor trap 75mm with grating including jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) bends any radius 75 mm bore complete all as specified and directed.
S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F for salt-glazed stoneware gully traps, square or round mouthed, tvpe 'P' of size 180 x 150 mm complete all as specified and directed.
S & F 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and PVC flush pipe 32 mm dia complete all as specified and directed.
S&F in repair stop valve chromium plated 15 mm bore fancy type with long shank and cup (concealed type) complete all as specified and directed.
Supply and fix in repair brass chromium plated shower rose 125 mm size complete all as specified and directed.
Supply and fix in repair 15 mm bore angle valve cast copper alloy, chromium plated, fancy type screwed down, high pressure, screwed both ends for iron pipe or for unions complete all as specified and directed.
Supply and fix in repair bib taps 15mm bore, cast copper alloy, with crutch or butter fly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair 15mm dia 600 mm long PVC connection including 02 Nos union on both ends screwed for iron pipes complete all as specified and directed.
S & F in repair vitreous China under counter wash basin oval type of size 56 cm x 41 cm x 18 cm of white colour including 32 mm dia waste coupling chromium plated brass and PVC waste pipe complete all as specified and as directed.
S&F in repair pillar taps fancy type for 15 mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair chromium plated tubular towel rail, 20mm dia, 60cm long complete all as specified and as directed.
S & F rotational moulded triple layered polyethyene water storage tank of capacity 1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position including nipple suitable for water tank including dismantling of existing water tanks of capacity 500 to 1000 ltr and removing to store complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. (Cleaning repairing, etc. measured separately)
Taking down/removing of existing water proofing treatment of any description on roof surfaces including tiles and wall surfaces complete, including screed bed, racking out joints, hacking for key scrubbing down with water etc., and removing rubbish out of MD land complete all as specified and directed.
M & L for roof treatment by preparation of plastered roof surface and applying Polymer APP modified membrane with non- woven polyster reinforcement/mat with thermal insulation, weight not less than 3kg/sqm and thickness not less than 3mm, laid by torch application method with overlap 100mm on length side and 100mm on the width side over a coat of cold applied bituminous oil based primer(IS-3384) @ 0.30 litre/sqm over rendering 10 mm thick with WPC on concrete surface in cement mortar 1:4 with liquid WPC @ 200ml /50Kg bag of cement as per manufacturer's instructions complete all as directed. Note:- WPC shall be measured and paid separately under respective item.
M&L for cement concrete tiles 20cm x 20cm x 20mm thick, machine pressed over 15 mm thick screed bed in cm 1:4 set jointed and pointed in neat cement slurry in floors, and cut and polished complete all as specified and directed.
All as per item No 98 above but except concrete tile of any description , complete all as specified and as directed.
M&L for 40 mm bore PVC High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceiling or in floors etc complete all as specified and directed.
Rooting out trees, flora & fauna and foliage as grown on RCC roof surfaces and brick walls by cutting hole into slabs/walls for digging out roots and using chemical to burn deep rooted tree roots etc and making good disturb portion of wall/roof with cement concrete 1:2:4 type B 1 complete all as specified and directed.
Taking down existing loose cement plaster including unsound weaken cement concrete at any position on existing RCC roof projection, ceiling, beam, column and chhajja and cleaning of exposed reinforcement with wire/rotary wire brush , making the surface free from loose material, dirt etc and applying two coats of alkaline rust converting primer (i.e rust remover) FEOVERT confirming to ASTM-B-117,on the rebars (measurement shall be on the basis of exposed concret) complete all as specified and directed. (Make : Feovert of Krishana Conchem,roff rust cleaner of Pidilite, Dr Fixit rust remover, shaliRustOff of STP Ltd).
M & L for providing and applying two coats of anti-rust protective coating in the form of acrylic polymer with cement in (1 :1.5) proportion ( 01 part polymer and 1.5 parts cement ) on rebars after cleaning of rust scales as per manufacturers instructions ( measurement on the basis of exposed concrete area ) complete all as specified and directed. (make IPNET of Krishana Conchem, new coat from Dr Fixit).
M & L for providing and applying stuctural grade EPIBOND-21-LP prior to application of any type of mortar plaster are micro concreting confirming ASTM -C-882-91(Arizona stant shear test) to ensure bonding between old concrete and new concrete complete all as specified and directed.
M&L for 25mm thick external plaster in two layers (15mm thick base coat + 10mm thick finishing coat) by using factory manufactured pre mix/ ready mix dry mortar like 'Roofit mix' of M/s Premium Floor to Roof materials Pvt Ltd/ 'Easy plast' of M/s Walplast Products Pvt Ltd/ 'Readiplast' of M/s Ultratech cement Ltd/ Sound Plast PMC-1' of M/s Sound buildcare Pvt Ltd or other equivalent make as approved by GE having composition of cement and sand should not be less than 1:4 ratio with other ingredient as per manfacturer instructions. The consistancy and application of mortar should be as per manufacturer's instruction, including making grooves of existing size whichever required, including cleaning the surfaces, curing etc complete all specified and as directed.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1:3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash complete all as specified and directed.
Taking down main switch/DB/AC box of any capacity including fixing accessories complete all as specified and directed.
M&L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.5 mm with earth dolly suitable for mounting modular switches incl modular metal flush boxes and modular face plate as per site requirement for fixing of modular switches / sockets, fan regulators, including PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of Paris/ Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed.
All as per item No 108 here-in-before but for one socket point controlled by one switch on independent board.
All as per item No 108 here-in-before but for one socket point controlled by one switch on same board.
All as per item No 108 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified.
S&F switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and directed.
S&F socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified and directed.
S&F in replacement, ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used TPN, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar suitable for TPN MCB / 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed.
S&F MCB, SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs fixed in repairs complete all as specified & directed.
S&F MCB, SP 240 volt 40 Amp to 63 amp 10 KA capacity having C-curve characteristics connected with suitable lugs fixed in repairs complete all as specified & directed.
S&F MCB, SPN 240 volt 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs fixed in repairs complete all as specified & directed.
S&F MCB,TPN 240 volt 40 to 63 amp 10 KA capacity having C-curve characteristics connected with suitable lugs fixed in repairs complete all as specified & directed.
M & L for sub main wiring with two single core PVC-FRLSH insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in new/existing MS/PVC conduit with 4 Sqmm PVC-FRLSH insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length. (ii) PVC Conduit if required shall be measured and paid separately under respective item.
M & L for sub main wiring with four single core PVC-FRLSH insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in existing/New MS/PVC conduit with 6 Sqmm PVC-FRLSH insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Note : (i) four single core cable and one run of earth copper conductor will be measured and paid as one unit length. (ii) PVC Conduit if required shall be measured and paid separately under respective item.
S&F rigid non metallic medium white / ivory PVC conduit medium grade ISI marked of size not less than 20 mm dia concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc complete all as specified and directed.
All as per item No 125 here-in-before but of conduit size 25 mm dia complete all as specified and directed.
M&L for taking down old unserviceable LED light fitting of any capacity and rating complete all as specified and directed.
M&L for refixing of serviceable LED light fitting after checking it of any size and any make by taking it out from existing location (wall/roof etc) and fixing it to any other location including all fixing arrangement of wall/roof along with electrical connection complete all as specified and directed.
S&F energy saving LED 4ft Batten 20 Watt with a nominal system lumen output of 2500 lumens and a minimum system efficacy of 110 lm/W with fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting and removing UNSV . The luminaire shall have a rate system lifetime of 40,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP 20 rating with THD < 10% and PF > 0.95. The luminaire housing should made of Extruded aluminium batten with a PC glossy diffuser complete all as specified and directed. Make : Philips Cat No : BN 021 LED 20S 6500 PSU GR S1 or equivalent in Wipro / GE.
S&F energy saver LED Smart Batten fitting 10 watt, 230 Volts, Box type. etc and accessories, including required fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting and removing UNSV bracket with sketch fitting complete all as specified and directed. Make : Philips Cat No BN 021 LED10S - 6500 PSU GR S1 or equivalent in Wipro / GE
S&F security light fitting 36 watt LED with pressure die cast housing IP 65 suitable for secondary road/bldgs. Power consumtion should not be more than 35 watt and power factor should not be less than .90 complete all as specified and directed. Make : Philips Cat Part No : BRP046 LED 36 CW MR S1 PSU GR or equivalent in Wipro / GE.
Supply and fixing as new exhaust fan 300 MM sweep steel body heavy duty with louver mounting bracket ISI marked 4 star rated energy saving less noise capacitor type including plastering colour coding and all site required work for disturbed surface matching with existing and making electric connection using three core copper cable drawn through in PVC conduit pipe including taking down of existing exhaust fan and finishing of disturbed surfaces by using cement mortar 1:3 complete all as specified and directed.
M&L earthing complete with galvanised steet earth electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth electrode not less than 1.5 mtr below normal ground level, connected to galvanised iron wire 4mm as earth wire by means of bolt, check nuts & washer of GI or steel connected to earth test point including earth strip from earth electrode to test point, Gl pipe 20 mm dia light grade as protection pipe and 20mm dia GI pipe light grade for watering pipe of required length including charcoal dust, common, salt, excavation and earth work, earth pit with PCC 1:3:6 type C 1 using 20mm graded stone aggregate, precast RCC cover 40mm thickness reinforced with 03 Nos TMT bars, 8 mm dia, both ways, funnel with wire mesh, testing and rest as shown in electrical plate No 3 of SSR Part -I complete all as specified and directed. (Note: (i) Excavation earth work and all connected items shall be deemed included in quoted unit rate. (ii) GI earth wire and GI protection pipe 20mm dia beyond 7.5m long shall be measured and paid separately.
M&L for circular / rectangular framed shutters suitable for 12" exhaust fan made out of MS sheet for shutter painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories all as per existing & as per site requirement complete all as specified and directed.
M&L for scraping all foreign materials with emery paper, cleaning the circular/rectangular framed shutter suitable for 9/12" exhaust fan as per site and painting with one coat of supper enameled grey paint (spray paint) at site complete all as specified and directed.
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting of exhaust fan/air circulator fan/pedestal fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with synthetic enameled black paint including serviceing, greasing complete all as specified and directed.
M&L for cutting / boring of PCC/hard standing at a depth not more than 15 cm deep and 15 cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B-0 or cement mortar (1:3) complete all as specified and directed.
S&F MCCB enclosure suitable for MCCB of capacity 63 Amp 4 Pole including necessary arrangement for wall mounting complete all as specified and as directed.
Supply and fixing MCCB 63Amps, 4 Pole, 415V, 25 kA , Ics =100 % Icu with thermal magnetic protection unit(O/L & S/C protection) complete all as specified and as directed.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
S&F of GI pipe light grade of size 15 mm bore for laying in trenches/floors or walls including all fittings complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out for taking out/laying pipes in soft/loose soil complete all as specified and directed.
Returning, filling,including spreading levelling watering and well ramming in layers not exceeding 25cm thick in solf/loose soil after pipes are laid complete all as specified and directed .
Removing of excavated material not exc 50 mtr distance and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road for passing of GI/CI/DI pipes all as specified and directed . Note : Making good with PCC shall be measured and paid separetely under respective item.
M&L for cement concrete 1:2:4 Type B 1 using 20 mm graded stone aggregate complete all as specified and as directed.
M&L for PCC 1:2:4 Type B2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection pipe upto 200 mm bore complete all as specified and directed. Note: Depth of bore shall not be more than 1 Mtr from original ground level.
Taking up/ down of 15 mm bore steel tubing and connections from excavated trenches and building up to tripple storey with due care including removal from site complete all as specified and directed. (60+1000)
All as per item No 149 above but size 20mm bore (346+400)
All as per item No 149 above but size 25mm bore
All as per item No 149 above but size 40mm bore
All as per item No 149 above but size 50mm bore
Re-fixing old steel tubing and connection in new or old position in trenches/wall/ ceiling/ floors etc with using new fittings complete as directed of sizes 15mm bore (20+300)
All as per item No 154 above but size 20mm bore (100+200)
All as per item No 154 above but size 25mm bore
All as per item No 154 above but size 40mm bore
All as per item No 154 above but size 50mm bore
S&F for mild steel tube GI pipe medium grade ISI marked with all necessary fittings laid in trenches / floor /wall or ceiling of size 15mm bore complete all as specified and directed. (40+700)
All as per item No 159 above but size 20mm bore (246+200)
All as per item No 159 above but size 25mm bore
All as per item No 159 above but size 40mm bore.
All as per item No 159 above but size 50mm bore.
Supply & fixing in replacement of Gun metal Gate valve ISI marked with Iron wheel, head screwed both ends for Galvanised Iron pipe for sizes 15mm bore complete all as specified and directed.
All as per item No 164 above but size 20mm bore (24+20)
All as per item No 164 above but size 25mm bore
All as per item No 164 above but size 40mm bore.
All as per item No 164 above but size 50mm bore.
M&L for construction of valve chamber in replacement 600 x 600 x 600 mm internal dimensions, 6 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40x40x6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6), 230 mm thick, PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces incl dismantling and removal of old unserviceble valve pit remains all as specified and directed.
Taking down carefully geyser (Storage type) of any make of capacity 25/50 Ltrs at any height disconnecting electrically and mechanically from all existing line opening complete including back plate, inner copper tank etc. de-scaling of copper tank , heating element and cleaning with Sulphuric Acid / de-scaling compound and reassembling and fixing in same position after necessary repair / replacement including replacement of old nuts & bolts and rubber gasket etc inside the geyser complete all as specified and directed. Note :- (i) Replacement of unserviceable spares shall be measured and paid seperately under appropriate items of Schedule 'A' as supply only.(ii)inspection of electric geyser any capacity, any type, any make for minor defect tightening of nut and bolts, connecting wire, pipe lines and rectifing the defects all as specified and directed.
S&F in repair only heating element 2000 watt capacity push / screw type with 'O' ring including making electrical connection complete all as specified and directed.
S&F in repair thermostat switches ISI marked including making connections complete all as specified and directed.
S&F in repair indicating lamp round / rectangular, Red / Green 220 Volts AC as per site requirement including electric connections complete all as specified and directed.
S&F in repair in repair of PVC connection 450 mm long with two nos nut adopter ISI marked for hot water complete all as specified and directed.
S&F in repair in repair of PVC connection 450 mm long with two nos nut adopter ISI marked for cold water complete all as specified and directed.
M&L in repair for soldering/brazing of inner tank of geyser of any type & capacity complete all as specified and directed.
Supply & fixing in repair stop cock cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for GI pipe 15 mm dia bore complete all as specified and directed. (12+180)
Supply only 3 core PVC sheathed copper conductor flexible cable of size 2.5 sqmm complete all as specified and directed.
Supply & fixing outer cover made of MS steel (As per existing) duly painted with one coat of synthetic enamel paint of 25 Ltrs capacity Geysers complete all as specified and directed.
Supply & fixing inner steel tank of capacity 50 Ltrs Geysers complete all as specified and directed.
Supply and fixing in repair Single pole and neutral enclosure 20 Amp with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.
S&F in repair pressure release valve of suitable size complete all as specified and directed.
S&F in repair Fastener of suitable size complete all as specified and directed.
Supply and fixing Plug Top 5 Amp 3 pin 230 volt complete all as specified and directed.
S&F in replacement sheet metal enclosures for MCB distribution board TPN, 4 way double door type including with MCCB 4 Pole, 100 Amps, 16 KA fixed type as incomer with 200 amp rated bus bar complete all as specified & directed.
SAXENA BANDHU
MITHILA BUILDERS AND ENGINEERS
Deepesh Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .