Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC NO 1 4 56 Y SRI BHARATHI NAGAR OPP PARVATHI THEATER CUMBUM ROAD THENKARAI PERIYAKULAM THENI DT 625 601 | PERIYAKULAM | THENI | TAMIL NADU | 625601 | L1 | Accepted-AOC AOC | |
| 2 | L2₹35.3 L+₹75,035 (2.17%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹36.1 L+₹1.6 L (4.57%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹36.7 L+₹2.1 L (6.17%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
28 Jul 2023, 6:00 pmClosed
GE(South) Bangalore
GE(South) Bangalore
REPAIR/ REPLACEMENT AND MAINT OF INTERNAL ELECTRIFICATION, EXTERNAL ELECTRIFICATION AND EXTERNAL WATER SUPPLY WKS AT VARIOUS DAD OFFICES AND RESIDENTIAL COMPLEX UNDER AGE E/M (SOUTH) OF UNDER GE (SOUTH) BANGALORE
2023_MES_607415_1
8729/E8
Open Tender
Civil Works
Item Rate
180 days
Bangalore
As per tender document
6 documents required · 6 mandatory
₹500
GE(South) Bangalore
₹90,000
Yes
18 Oct 2023
30 Jun 2023
31 Jul 2023
30 Jun 2023
28 Jul 2023
14 Jul 2023
Amount
INTERNAL ELECTRIFICATION
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L in replacement point wiring, concealed by using 1.5 Sqmm PVC insulated sheathed, FRLS, copper conductor multistrand drawn in suitable sunken box and frame cover plate for mounting of modular switches/sockets as required at site and provn of PVC rigid non metallic conduit medium density ISI marked fixed with all fittings and all accessories complete including cutting chasing to the existing surface to conceal the conduit and making good to the disturbed surface to match with the existing surface provision of 1.5 Sqmm PVC insulated, FRLS copper conductor continuos earth wire connected to common earth dolly including complete all as directed.. (Note :- MS Sunken boxes, cover plates with frame switches, sockets shall be measured and paid seperately in an appropriate Item of Sch 'A' and laying/fixing of sunken box and cover with frame is included in quoted rate.
(a) One light/fan point controlled by one switch/push button
(b) One 3 pin 5 Amps socket outlet point on independent board
(c) One 3 pin 5 Amps socket point on the same board with other switches
(d) One bell point controlled by one switch/push button
All as per item No.2 above but with 4.00 Sqmm cable for one 3 pin 15A socket outlet point on independent board
M&L for point wiring in replacement of surface type with single core 1.5 Sqmm PVC insulated sheathed single core multistranded copper conductor cable (FRLS)including 1.5 Sqmm PVC insulated sheathed copper conductor as earth continuity conductor drawn in and including ISI marked PVC casing caping not less than 20mm width with its accessories, and fixed in existing sunk boxes and covered with new 3.00 mm thick ISI marked laminated sheet cover and brass screw with cup washers for fixing switches/sockets/regulators etc.
(a) One light/fan/bell point controlled by one switch/push button
(b) One 3 pin 5 Amps socket outlet point on independent board
(c) One 3 pin 5 Amps socket point on the same board with other switches
(d) One light point controlled by two way switches
All as per item No.4 above but with 4.00 Sqmm cable for one 3 pin 15A socket outlet point on independent board
S&F in replacement switch Modular type 5A one way all as specified and directed.
S&Fin replacement one way switch 16A one Module all as specified and directed.
S&F in replacement socket outlet 2 in 1, 3 pin, 5 Amps Modular type all as specified and directed.
S&F in replacement socket outlet 6/16Amps modular type all as specified and directed.
S&F in replacement Modular type bell push,flush type, 5 Amps all as specified and directed.
S&F in replacement fan regulator,120 Watts, electronic socket step modular type all as specified and directed.
S&F in replacement ceiling rose surface bakelite 65 x 50mm 3 terminals all as specified and directed.
Taking down old unserviceable sunken box and mounting plates any size.
S&F in replacement of MS sunken box and PVC cover plate with frame suitable for accommodating 02 Nos modular switch/socket etc complete all as directed.
S&F in replacement of MS sunken box and PVC cover plate with frame suitable for accommodating 03 Nos modular switch/socket etc complete all as directed.
S&F in replacement of MS sunken box and PVC cover plate with frame suitable for accommodating 04 Nos modular switch/socket etc complete all as directed.
S&F in replacement of MS sunken box and PVC cover plate with frame suitable for accommodating 06 Nos modular switch/socket etc complete all as directed.
M & L in replacement of switch piano, flush type single pole, one way 5 Amps all as specified and directed. Make- Anchor/Indoasian/Plaza
M & L in replacement of switch piano, flush type single pole, two way 5 Amps all as specified and directed. Make- Anchor/Indoasian/Plaza
M&L in replacement of switch socket combination, 2in1, 3 pin,6A all as specified and directed. Make- Anchor/Indoasian/Plaza
M&L in replacement of switch socket combination, 2 in 1, 3 pin, 6 Amps and 16 Amps flush type.all as specified and directed. Make- Anchor/Indoasian/Plaza
Supply and fix in replacement of stepped type electronic fan regulator flush type, 230 volt, AC complete.Make- Anchor/Indoasian/Plaza
M&L in replacement of bell push, flush type, 5 Amps.Make- Anchor/Indoasian/Plaza
M&L in replacement of call bell ,ding dong type,AC, 230 volts single pole
S&F in repairs Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings.Make- Anchor/Indoasian/Plaza
S&F in replacement ceiling fan capacitor of 2.5 mfd all as specified and directed.
S&F in repairs Plug top 3 pin 6A ISI marked Make- Anchor/Indoasian/Plaza
S&F in repairs Plug top 3 pin 16A ISI marked Make- Anchor/Indoasian/Plaza
S&F in repairs PVC FRLS copper cable 1.5 sqmm complete all as specified and directed. Make- Anchor/Indoasian/Plaza Anchor/Indoasian/Plaza
S&F in repairs PVC FRLS copper cable 2.5 sqmm complete all as specified and directed.Make- Anchor/Indoasian/Plaza
Taking down old unserviceable sub main wiring any size.
Material and labour in replacement of sub main wiring concealed type with three runs of single core, PVC insulated unsheathe multi-stranded copper conductor cable of size 10 Sqmm, 1100 volts grade (FRLS) and one run of 10 Sqmm PVC insulated multi-stranded copper conductor cable (FRLS) for earth continuity conductor drawn through and including suitable size ISI marked rigid fire retardant PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows etc including cutting chasing existing surface to conceal the conduit and making good to the disturbed surface to match with existing surface complete all as specified and directed. Note : Four runs of 10 Sqmm cable, one run of 10 Sqmm continuity earth wire and one run of PVC non metalic conduit with all necessary accessories will be measured as one length.
Material and labour in replacement of sub main wiring concealed type with Two runs of single core, PVC insulated unsheathe multi-stranded copper conductor cable of size 10 Sqmm, 1100 volts grade (FRLS) and one run of 10 Sqmm PVC insulated multi-stranded copper conductor cable (FRLS) for earth continuity conductor drawn through and including suitable size ISI marked rigid fire retardant PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows etc including cutting chasing existing surface to conceal the conduit and making good to the disturbed surface to match with existing surface complete all as specified and directed. Note : Two runs of 10 Sqmm cable, one run of 10 Sqmm continuity earth wire and one run of PVC non metalic conduit with all necessary accessories will be measured as one length.
Material and labour in replacement of sub main wiring concealed type with Two runs of single core, PVC insulated unsheathe multi-stranded copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi-stranded copper conductor cable (FRLS) for earth continuity conductor drawn through and including suitable size ISI marked rigid fire retardant PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows etc including cutting chasing existing surface to conceal the conduit and making good to the disturbed surface to match with existing surface complete all as specified and directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC non metalic conduit with all necessary accessories will be measured as one length.
Taking down old unserviceable MCB DB any size any capacity .
S&F in repair sheet metal enclosure Triple pole and neutral , 415 volts, 4 way double door with 200 Amps rated bus bar including taking down old unserviceable DB/main switch board complete all as specified and as directed.
S&F in repair sheet metal enclosure single pole and neutral , 240 volts, 16 way double door with 200 Amps rated bus bar including taking down old unserviceable DB/main switch board complete all as specified and as directed.
S&F in repair sheet metal enclosure single pole and neutral , 240 volts, 12 way double door with 200 Amps rated bus bar including taking down old unserviceable DB/main switch board complete all as specified and as directed.
S&F in repair sheet metal enclosure single pole and neutral , 240 volts, 8 way double door with 200 Amps rated bus bar including taking down old unserviceable DB/main switch board complete all as specified and as directed.
S&F in repair sheet metal enclosure single pole and neutral , 240 volts, 4 way double door with 200 Amps rated bus bar including taking down old unserviceable DB/main switch board complete all as specified and as directed.
Taking down old unserviceable MCB TPN/SPN/Sp any size
S&F in replacement of MCB TPN 40 to 100 Amps, 415 Volt, 10 KA, 'C' curve complete all as specified and as directed.
Supply & Fixing in repair MCB TPN 16 to 32 Amps, 415 volts, 10KA, 'B' curve complete all as specified and as directed.
S&F in repair MCB SPN 32 Amps, 240 Volts,'C' curve complete all as specified and as directed.
S&F in repair MCB SP 5 to 32 Amps, 240 Volts,'C' curve complete all as specified and as directed.
S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps all as specified and directed .
Taking down old unserviceable earthing material
M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete.
Taking down old unserviceable light fitting any capacity
Supply and fixing LED light fitting mirror type with high out put diffuser 1 feet, 5 watts 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories all as specified and directed by Engr-in-Charge
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watts 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories all as specified and directed by Engr-in-Charge
Supply and fixing LED lights fitting 4 feet ,20 watts, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories all as specified and directed by Engr-in-Charge.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories all as specified and directed by Engr-in-Charge
Supply and fixing LED luminaire 600 mm x 600 mm (2 feet x 2 feet), 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete with all accessories all as specified and directed by Engr-in-Charge
Supply and fixing round shape 15 watt, 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete with all accessories all as specified and directed by Engr-in-Charge
S&F 40 Watt LED recess mounted 1'x4' panel light with high performance integrated electronic driver of operating voltage 110 to 265 Volts complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of 24/0.2mm size and taking down old unserviceable tube light fitting complete all as specified and as directed. Make:-Shakti Cat No. SZRSBMX040 or equivalant of Bajaj/Wipro/Philips.
Supply & Fix in repairs LED inverter batten tube light fitting 4 ft 18 watts complete all as specified and as directed. Make:-Shakti Cat No. SZSLBMX018-iBB or equivalant of Bajaj/Wipro/Philips.
Supply and fix wall mounting fan complete with electronic type regulator and accessories 230 V, 400mm sweep, BEE 5 star rated, ISI standards, RPM1200,340 Air Delivery 200CMM, down rod length 267mm, rust - free powder coated finish and pre-wired and including connecting up with twin core twisted flexible copper conductor cable with connector including dismatling old one deposit to AGE E/M Store yard complete. Make - Bajaj ESTEEM WALL FAN Product code 250542 or equivalent make of Havells/CG
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including dismatling old fan and depositing it to AGE E/M Store yard complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete including dismatling old fan and depositing to AGE E/M Store yard complete all as specified and directed by Engr-in - Charge.
Material & labour for drilling hole in walls for fixing of exhaust fan of size 300 mm and making good wall surfaces complete all as specified and directed by Engr-in-charge.
Supply and fix exhaust fan made of plastic ,voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm with louvers shutter, complete including dismatling old fan and depositing to AGE E/M Store yard complete all as specified and directed by Engr-in - Charge.
M&L for opening , cutting and taking out complete winding coils of ceiling fan of 1200/1400 mm sweep of any make , rewinding the same with super enamaled copper winding wire as per original pattern including varnishing complete and asembly after oiling greasing and replacing the worn out nut bolts and washers bearings etc and testing the ceiling fans on load for two hours complete all as specified and directed.
All as per item No-64 here in before but for exaust fan of sweep 250/300mm
M & L required for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.complete all as specified and directed by Engr-in - Charge.
EXTERNAL WATER SUPPLY
S&F in repairs Heating element 1500/2000Watt round Type complete
S&F in repairs Heating element 1500/2000Watt triangular type complete
S&F in repairs Thermostat for 25/50 Ltr cap geyser and making connection .
S&F in repairs PVC connection 15 mm bore with PTMT nuts of length 450mm
S&F in repairs PVC connection 15 mm bore with PTMT nuts of length 600mm
Fixing only electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.including connecting up with three core copper conductor cable to 15Amps plug top including dismatling old one deposit to AGE E/M Store yard complete. Note : Geysers will be issued by DAD for fixing only.
Supplying and Fixing in repairs CPVC pipes 20mm all SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling and make necessary connection for fitment of geysers complete all as specified.
Supply & Fixing in repairs 20 mm dia CPVC brass elbow complete all as specified.
Supply & Fix in repairs Bib taps, cast copper alloy 15mm fancy type, chrominium plated screwed down,crewed high pressure with capstan head, screwed down for iron pipe complete all as specified.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.including connecting up with three core copper conductor cable to 15Amps plug top including dismatling old one deposit to AGE E/M Store yard complete.
Supply & laying CPVC pipes SDR 13.5 pipes & plain CPVC SDR 11 fittings walls/ceiling or laying in floors including taking down the old unserviceable GI pipe from trenches/walls/floors complete all as speicfied and directed for following sizes :-
(a) 20 mm dia
(b) 25 mm dia
(c ) 40 mm dia
(d) 50 mm dia
Supply & laying 100 mm GI pipe fittings Tubes, 'medium grade' galvanised with all fittings complete laid in trenches including taking down the old unserviceable GI pipe from trenches complete all as speicfied and directed
Laying only 80 mm GI tubing medium grade with all fittings complete laid in trenches including taking down the old unserviceable GI pipe from trenches complete all as speicfied and directed. Note : GI tubing medium grade 80mm will be issued under Sch 'B'
Fixing only in repairs Gun metal gate valve in repairs with inner wheel head, screwed both ends in iron pipe and fixed in the following sizes . Note : Gun metal gate valve of size 20mm,25mm & 40 mm will be issued under SCH 'B'
(a) 20 mm dia
(b) 25 mm dia
(c) 40 mm dia
Supply & Fixing in repairs Gun metal gate valve 50mm with inner wheel head, screwed both ends in iron pipe and fixed in the following sizes
Supply & Fix in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed of following sizes as under :-
(a) 15 mm dia with minimum weight 142 grams
(b) 20 mm dia with minimum weight 210 grams
(c ) 25 mm dia with minimum weight 455 grams
Material & labour for scrubbing, cleaning thoroughly for removing the dirts,sediments,silts etc from the internal surfaces of UG sump (bottom & walls) by using brushes and bleaching powder and other cleaning materials as required including pumping arrangement for drain out the water and applying two coats of lime wash inside the wall surface of the tanks ,and two coats of colour applying(colour should be light yellow) on outside walls of sump including writing the words "MILITARY ENGINEER SERVICES, TANK CAPACITY , DATE OF CLEANING AND NEXT DUE DATE" in capital letters of suitable size on outside visible surface of sump with synthetic enamel paint(white colour) over black background , and all the steel surfaces shall be painted with two coats of synthetic enamel paint(blue colour) after preparation of the surfaces at EDP/DAD pump house for the following sizes sump capacities as under :-
(a) UG sump of capacity 5000 gallon at EDP centre pump house
(b) UG sump of capacity 1.65 lakhs gallon at DAD/DCA pump house area
(c ) UG sump of capacity 1 lakh gallon at RWH sump in DAD/DCA area
Demolition of existing old unserviceable brick masonary valve chamber including demolition of unserviceable M.S iron cover and frame and construction of new valve chamber 60x60x60 cm inner dimensions, brick masonary in CM 1:4 PCC base in 1:3:6 of 7.5 cm thick & plastering 15 cm thick in CM 1:4 in inner side/coping of all chamber fabrication of iron frame 40x40x6 mm size angle iron MS cover 3mm thick with hinges and locking arrangements duly painted including excavation and earth work complete all as specified and directed by Engr-in-charge.
Supply and fixing in repairs new cast iron foot valve 80 mm dia flanged ends swing type operation,as per IS-4038 with necessary bolt and nuts etc, including taking down old unserviceable foot valve complete all as directed by Engr-in-charge . Make kirloskar/kartar
and Supply and fixing in repairs new cast iron foot valve 100 mm dia flanged ends swing type operation,as per IS-4038 with necessary bolt and nuts etc, including taking down old unserviceable foot valve complete all as directed by Engr-in-charge . Make kirloskar/kartar
Matireal & labour for PCC 1:4:8 type D2 ( using 40mm graded stone aggregate ) as in foundation, mass concrete for road crossing etc. complete all as specified and directed.
Matireal & labour for PCC 1:3:6 type C2 ( using 20mm graded stone aggregate ) as in foundation, mass concrete for road crossing etc. complete all as specified and directed.
Matireal & labour for PCC 1:2:4 type B2 ( using 40mm graded stone aggregate ) as in foundation, mass concrete for road crossing etc. complete all as specified and directed.
S&F gland packing of 10mm dia
S&F gland packing of 12 mm dia
S&F Rubber coupling for motor and pump round type and star type of good quality to match the existing sample .
M&L for sign board of PVC flex sheet of thickness 6mm for all pump house/under AOR GE (S) Bangalore at various locactions of size, colour ,including computerised printing of letters complete all as specified and directed by Engr in charge.
Taking down old unserviceable meter box and supply,fabricate, test and commissioning wall mounting meter box of size 750 mm x 750mm x 200 mm depth concealed type, powder coated made of 2.0 mm thick CRCA sheet, weather and vermin proof with double stud hinged door front open with internally locking arrangement and externally locking arrangement with aldrop bolt and hylum sheet of suitable size should be fixed inside box including dismantling old meters and cut outs from old box and refixing energy meter in nw box complete all as specified and directed. Note :- Fixing of MCCB & MCBs of various capacities in new meter box shall be measured and paid seperately
Disconnecting the motor of 25 HP capacity by delinking the pump set, transporting to workshop, opening the motor, removing the unserviceable /burnt windings from the motor stator, cleaning the stator slots with petrol, rewinding with existing size of copper winding wire,insulating it, re-assembling trasporting to site, fixing on foundation,re - connecting the motor and testing at load to the satisfaction of Engineer-in-charge. NOTES:- (i) Transportation and necessary T&P for shifiting the motor to workshop and back is deemed to be included in the quote rates. (ii) Major spares and bearing, coupling etc wil be measured and paid under relevent items of this scehdule.
All as per item No-94 here in above but 15HP/12.5 HP
All as per item No-94 here in above but 5/3 HP
Supply in replacement driving End (DE) and non- driving End (NDE) bearing suitable for 25 HP motor
All as per item No-97 here in above but 15HP/12.5 HP
Overhauling of monoblock/centrifugal pump set of 25 HP capacity from motor by dis- engaging the coupling taking out the pump from the foundation and transporting to the workshop if required, opening the pump, taking out the shaft along with impeller, removing the foreign materials from inner casing cleaning checking for wearing out of the impeller, bearing sleeves shaft etc. replaing the worn out parts, assembling the pump complete by replacing the gasket, nuts bolts washers greasing of bearings, all as required, transporting pump to site mounting on base frame checking for proper alignmment of pump shaft with motor shaft, adding the shafts couping and test runing for smooth operation all specified and as directed. NOTES:- (i) Transportation and necessary T&P for shifiting the motor to workshop and back is deemed to be included in the quote rates. (ii) Major spares and link coupling etc wil be measured and paid under relevent items of this scehdule.
All as per item No-99 here in above but 15HP/12.5 HP
All as per item No-99 here in above but 4HP/3/2HP
Supply in replacment of CI sleeves suitable for centrifugal pump of capacity 25HP Complete all as specified and as directed.
All as per item No-102 here in above but 12.5 HP
Supply in replacment of cast iron impeller suitable for 25 HP pump capacity pump set Complete all as specified and as directed.
All as per item No-104 here in above but 15/12.5 HP
Supply in replacemnet Love joy coupling complete with star bushes for the following capacity of the motors including dismantling the existing unserviceble coupling all as directed for Centrifugal pump set driven by 25HP Capacity 3 phase, 415 Volts 50Hz AC supply Complete all as specified and as directed.
M&L for shifting Submercible pump assy from borewell, shifiting to workshop, dismantling the motor , megger testing the motor, removing the burnt damaged winding and rewinding with appropriate size of copper winding wires re-insulation to the testing of motor. opening the pump set cleaning the impellers supplying and fixing required Nos of bearing, bush after removing existing wornt out bush bearing of pump set up to 08 stages assemblings the pumps reassembling the motor and pump shifting to site and lowering the pump set along with GI pipes and cables including testing complete 12.5 HP capacity as directed. NOTE:- GI socket heavy duty if required replacement during lifting /lowering of GI pipe/impellers etc. will be measured and paid seperately.
Taking out old unserviceable star delta starter, supply and fix star dalta fully automatic in sheet metal enclosure type MN with SSP features suitable for operation of pumping set connected with induction motor of 25 HP Capaity 3 phase 415 Volts 50Hz AC supply complete all as specified and directed. Make L&T
Taking out old unserviceable DOL starter, supply and fix DOL fully automatic in sheet metal enclosure type MN with SSP features suitable for operation of pumping set connected with induction motor of 15/12.5 HP Capaity 3 phase 415 Volts 50Hz AC supply complete all as specified and directed. Make L&T
S&F on load changeover switch four pole 100Amps 415 Volts 415 volts AC manual changeover front handle opetated open execution type with handle including taking down old one change over switch connection complete all as specified and directed Make - L&T
S&F MCCB TP 100Amps capacity with rupturing capacity 15KA On the existing panel board including taking down old MCCB connecting complete all as directed Make -L&T
Supply and fixing in repair NRV of size 100 mm including taking down old U/s NRV complete all as directed.
M&L for scraping the rusted surfaces and peeled off paint of entire pumping set including pipe lines of various sizes along with base foundation plates applying metallic paint on surfaces and making the surface smooth and applying a coat of synthetic enamel paint of existing shade and writing the MES/SM number on the motor/pump/pipes/etc set all as directed.
EXTERNAL ELECTRIC SUPPLY
Excavation in trench not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and not exceeding 1.5m for laying of LT under ground cables/GI pipes getting out as in soft /loose soil complete all as specified and directed.
Returing & filling in trench spreading ,leveling watering and well ramming in layers not exceeding 25 cm deep as in deep as in soil complete all as specified and directed.
Removing excavated material n.exc 50 mtrs and deposting where directed at a leve n.exc 1.5 mtrs above starting point as in soil complete all as specifed and directed.
Taking down carefully old unserviceable UG cable of any size from the trenches/wall/pole from site after affording credit including removal of brick cable cover complete all as specified and directed.
Supply, laying dry river sand in trenches for cable cushioning all as specified in clause 19.75 of SSR part-I. Note :- Punned thickness of sand only will be measured & paid.
Supply, laying, testing and commissioning of LT under ground cable XLPE in repair insulated armoured, heavy duty, elelctric cable, size 10 Sqmm 2 Core with stranded aluminium conductor, 1100 Volts grade conforming to IS -7098 (Part-I) 1988 laid in trenches /walls/floors /ducts etc fixed with saddle and clamps or passing through pipes complete with cable ends connection with proper thimbles nut bolts washer all as directed .
All as per item No.119 but of size 10 Sqmm x 4 core
All as per item No.119 but of size 16 Sqmm x 4 core
All as per item No.119 but of size 25 Sqmm x 4 core
All as per item No.119 but of size 50 Sqmm x 3.5 core
Supply and lay burnt bricks cable cover, class LV, type 1, flat, size 230mm x 115mm x 70mm in replacement of burnt bricks used as cable protection covers complete all as specified and directed.
Supply & Laying in repair GI tubing light grade of size 40 mm with necessary fittings as in cable protection laid in trenches/road/fixed on wall / floor including necessary clamps bolts and nuts complete all as specified and directed.
M&L preperation of surfaces of pole for painting of steel tubular pole, vertical with one coat of aluminium paint including painting black and white strip or as ordered by Engr-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures (Block), height not exceeding 30 cm high & letters and figures not exc 10 Nos complete all as directed.
M&L preperation of surfaces of pole for painting of PCC pole, vertical with one coat of aluminium paint including painting black and white strip or as ordered by Engr-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures (Block), height not exceeding 30 cm high & letters and figures not exc 10 Nos complete all as directed.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
All as per No.128 but of 60watts
All as per No.128 but of 90watts
Supply and fixing GI pipe bracket made of 40 mm bore light grade pipe made to shape of overall length of 1.2 mtr for fixing of security light fitting including MS clamps , nuts & bolts of required size complete all as specified and as directed.
S&F in replacement of LED street light fittings driver for various capacity 45/60/90 watts complete all as specified.
S&F inreplacement PVC conduit pipe from PVC junction boxes to street light bracket for protection of cable, fixing of clamp on PCC poles complete all as specified.
S&F PVC 3 core copper cable 1.5 sqmm insulated for fixing of junction boxes to street light fittings complete all as specified and directed.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
GS TRADERS
RAMSON TRADERS
RRK PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .