| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.1 LAccepted-AOC A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹68.8 L+₹64,235 (0.94%)Rejected-Finance VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹74.8 L+₹6.6 L (9.73%)Rejected-Finance A T ROAD CHABUA NEAR ST LUKAS HOSPITAL PO CHABUA DIST DIBRUGARH ASSAM 786 184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹74.9 L+₹6.7 L (9.90%)Rejected-Finance NAV PUKHARI ROAD MILLAN PALLY PO DIST TINSUKIA ASSAM 786 125 | TINSUKIA | DIBRUGARH | ASSAM | 786125 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹75.4 L+₹7.3 L (10.7%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
| Sl No | Description | Qty | Unit | M/s Sashi Enterprise L3 | M/s Pramillabh Construction L4 | Singhs Construction L2 | kabitaconstruction L1 | M/S P.K.B.CONSTRUCTION L8 | M/S CHAKRA GOHAIN L6 | M/s Lalowari Electricals L7 | M/S A K MITRA L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation and testing of Retrofit emission control device suitable for DG set of capacity 320 KVA of Make Kirloskar, having ceramic carrier filter with 94% PM andoperational reduction level of CO, NOx,HC reduction up to alevel of 75% conforming to condition CPCBs latest regulationon RECD for DG set and including the requirementmentioned below complete all as specified and directed.
(i) Filter type :-Ceramiac Filter with Regeneration
(ii) Material of construction :- SS 304
(iii) Temperature Monitoring: - Temperature Sensor
(iv) Temperature monitoring sensor: - Before & after filter
Exhaust gas
(v) Differential Pressure sensor: - Before and after filter to
know the back pressure
(vi) Digital indication for monitoring Temp & Pressure.
(vii) Digital Output:- RS 485 RTU
(viii) Inlet connection for RECD-06 holes of 160 OD
(ix) High Heat Resistance and Low exhaust Resistance
(x) Auto bypass arrangement with respect to back pressure
(xi) Digital Dispay with tempeature and pressure indication
Note :- Contractor have to submit the complete test report ofexhaust emission (Engine performance test )without and with RECD from ICAT or recgnised NABL accredited lab/ central
or state polution board.
Note :- Any adnl/altn in exahaust system deemed in quoted rate. | 4 | Each | 12,43,200 ₹49,72,800 | 12,30,500 ₹49,22,000 | 11,30,000 ₹45,20,000 Lowest | 11,40,000 ₹45,60,000 | 13,15,554 ₹52,62,216 | 13,14,000 ₹52,56,000 | 13,14,240 ₹52,56,960 | 12,44,500 ₹49,78,000 |
| 2.00 | Supply, installation and testing of Retrofit emission control device suitable for DG set of capacity 35 KVA of Make Kirloskar, having ceramic carrier filter with 94% PM and operational reduction level of CO, NOx,HC reduction up to alevel of 75% conforming to condition CPCBs latest regulation on RECD for DG set and including the requirement mentioned below complete all as specified and directed.
(i) Filter type :-Ceramiac Filter with Regeneration
(ii) Material of construction :- SS 304
(iii) Temperature Monitoring: - Temperature Sensor
(iv) Temperature monitoring sensor: - Before & after filter
Exhaust gas
(v) Differential Pressure sensor: - Before and after filter to
know the back pressure
(vi) Digital indication for monitoring Temp & Pressure.
(vii) Digital Output:- RS 485 RTU
(viii) Inlet connection for RECD-06 holes of 160 OD
(ix) High Heat Resistance and Low exhaust Resistance
(x) Auto bypass arrangement with respect to back pressure
(xi) Digital Dispay with tempeature and pressure indication
Note :- Contractor have to submit the complete test report of exhaust emission (Engine performance test )without and with RECD from ICAT or recgnised NABL accredited lab/ central
or state polution board.
Note :- Any adnl/altn in exahaust system deemed in quoted rate. | 2 | Each | 4,46,775 ₹8,93,550 | 4,15,200 ₹8,30,400 | 4,01,000 ₹8,02,000 | 3,90,500 ₹7,81,000 Lowest | 4,23,504 ₹8,47,008 | 4,20,000 ₹8,40,000 | 4,27,350 ₹8,54,700 | 4,42,500 ₹8,85,000 |
| 3.00 | Supply, installation and testing of Retrofit emission control device suitable for DG set of capacity 30 KVA of Make Ashoka Leyland, having ceramic carrier filter with 94% PM and operational reduction level of CO, NOx,HC reduction up to alevel of 75% conforming to condition CPCBs latest regulation on RECD for DG set and including the requirement mentioned below complete all as specified and directed.
(i) Filter type :-Ceramiac Filter with Regeneration
(ii) Material of construction :- SS 304
(iii) Temperature Monitoring: - Temperature Sensor
(iv) Temperature monitoring sensor: - Before & after filter
Exhaust gas
(v) Differential Pressure sensor: - Before and after filter to
know the back pressure
(vi) Digital indication for monitoring Temp & Pressure.
(vii) Digital Output:- RS 485 RTU
(viii) Inlet connection for RECD-06 holes of 160 OD
(ix) High Heat Resistance and Low exhaust Resistance
(x) Auto bypass arrangement with respect to back pressure
(xi) Digital Dispay with tempeature and pressure indication
Note :- Contractor have to submit the complete test report of exhaust emission (Engine performance test )without and with RECD from ICAT or recgnised NABL accredited lab/ central
or state polution board.
Note :- Any adnl/altn in exahaust system deemed in quoted rate. | 4 | Each | 3,99,600 ₹15,98,400 | 4,15,200 ₹16,60,800 | 3,70,000 ₹14,80,000 | 3,50,000 ₹14,00,000 Lowest | 4,02,797 ₹16,11,188 | 4,00,000 ₹16,00,000 | 3,99,600 ₹15,98,400 | 4,02,500 ₹16,10,000 |
| 4.00 | M&L for excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard/dense soil complete all as specified and directed. | 14 | Each | 280 ₹3,920 | 300 ₹4,200 | 250 ₹3,500 Lowest | 350 ₹4,900 | 400 ₹5,600 | 250 ₹3,500 Lowest | 280 ₹3,920 | 300 ₹4,200 |
| 5.00 | M&L for PCC 1:4:8 type C2 using 40 mm graded stone aggregate for foundation of poles complete all as specified and directed. | 1.09 | Cum | 6,500 ₹7,085 Lowest | 9,500 ₹10,355 | 8,500 ₹9,265 | 7,000 ₹7,630 | 7,000 ₹7,630 | 6,500 ₹7,085 Lowest | 6,500 ₹7,085 Lowest | 7,000 ₹7,630 |
| 6.00 | M&L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as required or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. | 3 | Qtl | 180 ₹540 Lowest | 20,000 ₹60,000 | 21,000 ₹63,000 | 20,000 ₹60,000 | 19,500 ₹58,500 | 18,000 ₹54,000 | 18,250 ₹54,750 | 19,500 ₹58,500 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
19 Mar 2026, 6:00 pmClosed
GE (AF) Mohanbari
Garrison Engineer (AF) Mohanbari Mohanbari Post Dibrugarh Assam 786012
PROVN OF CONTROL SYSTEM FOR E/M MACHINERY AT ALG ALONG, WALONG AND AF STN MOHANARI UNDER GE (AF) MOHANARI
2026_MES_754591_1
8001/764/E8
Open Tender
Civil Works
Item Rate
180 days
ALG Along, Walong and Mohanbari
Class C, category b(i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (AF) Mohanbari
₹1.3 L
Yes
30 Mar 2026
27 Feb 2026
20 Mar 2026
27 Feb 2026
19 Mar 2026
13 Mar 2026
Supply, installation and testing of Retrofit emission control device suitable for DG set of capacity 320 KVA of Make Kirloskar, having ceramic carrier filter with 94% PM andoperational reduction level of CO, NOx,HC reduction up to alevel of 75% conforming to condition CPCBs latest regulationon RECD for DG set and including the requirementmentioned below complete all as specified and directed. (i) Filter type :-Ceramiac Filter with Regeneration (ii) Material of construction :- SS 304 (iii) Temperature Monitoring: - Temperature Sensor (iv) Temperature monitoring sensor: - Before & after filter Exhaust gas (v) Differential Pressure sensor: - Before and after filter to know the back pressure (vi) Digital indication for monitoring Temp & Pressure. (vii) Digital Output:- RS 485 RTU (viii) Inlet connection for RECD-06 holes of 160 OD (ix) High Heat Resistance and Low exhaust Resistance (x) Auto bypass arrangement with respect to back pressure (xi) Digital Dispay with tempeature and pressure indication Note :- Contractor have to submit the complete test report ofexhaust emission (Engine performance test )without and with RECD from ICAT or recgnised NABL accredited lab/ central or state polution board. Note :- Any adnl/altn in exahaust system deemed in quoted rate.
Supply, installation and testing of Retrofit emission control device suitable for DG set of capacity 35 KVA of Make Kirloskar, having ceramic carrier filter with 94% PM and operational reduction level of CO, NOx,HC reduction up to alevel of 75% conforming to condition CPCBs latest regulation on RECD for DG set and including the requirement mentioned below complete all as specified and directed. (i) Filter type :-Ceramiac Filter with Regeneration (ii) Material of construction :- SS 304 (iii) Temperature Monitoring: - Temperature Sensor (iv) Temperature monitoring sensor: - Before & after filter Exhaust gas (v) Differential Pressure sensor: - Before and after filter to know the back pressure (vi) Digital indication for monitoring Temp & Pressure. (vii) Digital Output:- RS 485 RTU (viii) Inlet connection for RECD-06 holes of 160 OD (ix) High Heat Resistance and Low exhaust Resistance (x) Auto bypass arrangement with respect to back pressure (xi) Digital Dispay with tempeature and pressure indication Note :- Contractor have to submit the complete test report of exhaust emission (Engine performance test )without and with RECD from ICAT or recgnised NABL accredited lab/ central or state polution board. Note :- Any adnl/altn in exahaust system deemed in quoted rate.
Supply, installation and testing of Retrofit emission control device suitable for DG set of capacity 30 KVA of Make Ashoka Leyland, having ceramic carrier filter with 94% PM and operational reduction level of CO, NOx,HC reduction up to alevel of 75% conforming to condition CPCBs latest regulation on RECD for DG set and including the requirement mentioned below complete all as specified and directed. (i) Filter type :-Ceramiac Filter with Regeneration (ii) Material of construction :- SS 304 (iii) Temperature Monitoring: - Temperature Sensor (iv) Temperature monitoring sensor: - Before & after filter Exhaust gas (v) Differential Pressure sensor: - Before and after filter to know the back pressure (vi) Digital indication for monitoring Temp & Pressure. (vii) Digital Output:- RS 485 RTU (viii) Inlet connection for RECD-06 holes of 160 OD (ix) High Heat Resistance and Low exhaust Resistance (x) Auto bypass arrangement with respect to back pressure (xi) Digital Dispay with tempeature and pressure indication Note :- Contractor have to submit the complete test report of exhaust emission (Engine performance test )without and with RECD from ICAT or recgnised NABL accredited lab/ central or state polution board. Note :- Any adnl/altn in exahaust system deemed in quoted rate.
M&L for excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard/dense soil complete all as specified and directed.
M&L for PCC 1:4:8 type C2 using 40 mm graded stone aggregate for foundation of poles complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as required or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tender.pdf
Tender Documents • 1.30 MB
BOQ_845174.xls
BOQ • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .