Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-Finance SANTINEKATAN ROAD BOLPUR | BOLPUR | L1 | Accepted-Finance ACCEPTED | |
| 2 | L2₹2.4 L+₹970.88 (0.41%)Rejected-Finance 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L2 | Rejected-Finance REJECTED | |
| 3 | L3₹2.4 L+₹2,642.97 (1.12%)Rejected-Finance COLLEGEPARA SURI BIRBHUM | BIRBHUM | WEST BENGAL | 731236 | L3 | Rejected-Finance REJECTED |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
24 Sept 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Driller In Charge, Birbhum Mechanical Sub Division
Suri, Birbhum
Supply delivery Installation of Inline Boosting arrangement pump for Uska habitation at Raipur WS scheme of Md Bazar block under Bolpur Mechanical Division PHE Dte
2024_PHED_742862_2
WBPHE/DIC/BMSD(D)/NIeT-03 of 2024-25
Open Tender
MECHANICAL
Item Rate
30 days
RAIPUR
Please refer Tender documents.
5 documents required · 5 mandatory
₹6,000
26 Sept 2024
3 Sept 2024
26 Sept 2024
3 Sept 2024
24 Sept 2024
3 Sept 2024
Amount
Supply and delivery at site of the following vertical multi stage pumping machinery and electrical accessories as per approved vendor list of PHED-
Supply and delivery installation of vertical multi stage Pump With pumping machinery directly coupled with water proof suitable size motor having following specification:- Pump: Duty condition -20 m3/hr, Head-36 Mtr, Shaft-stainless steel Impeller-S.S/GM. Outlet Size: 65mm/80mm., Motor: 5 HP 3 Ph, 50Hz, 415 Volt ± 10% 2900 RPM Motor must be suitable for operation with DOL Starter. (Test certificate along with characteristic curve should be submitted at the time of delivery). Model: Kirloskar ( KCIL 20-3)
Supply and delivery installation of 5 HP DOL starter for above mentioned pump (Relay range- 6A to 10A)
Supplying & laying of1.1KV grade 10 sq.mm3 core XLPE insulated Aluminium armoured cable conforming to IS 7098(Part-1) 1988, with upto date amendments
1.5mtr long 80mm dia UPVC standard type column pipe [cream color) with both side threaded and one end side socketed with registered KPMG
Laying of pipe line including cost of pipe & fittings of 180mm dia UPVC standard type column pipe [cream color) with both side threaded and one end side socketed with registered KPMG
80mm dia. CIDF Non-Raising Sluice Valves, PN 1.0 5.00 rating (Conforming to 15:14846) for delivery pipe line and wash out line. (MOC & TC needed for valve).
80mm dia. CIDF single door swing Non Return Valve, PN 1.0 rating (Conforming to 15:5312). (MOC & TC needed for valve).
2.5 inch/3 inch Enlarger/reducer for vertical mülti stage Pump to distribution line
80 mm dia CIDF 90°bend- 1no., CI/MS flanged short piece 0.50 mtr.-ino, CI/MS flanged pipe 1mtr.-1 no. etc (as per IS specification and certification registered) for construction
Supply and delivery of following fittings item for vertical multi stage pumping machinery and electrical accessories as per approved vendor list of PHED-
180 mm X 90 mm service saddle
MTA-90 mm
Tail Piece-90 mm
Tail Piece-160 mm
Tail Piece-250 mm
Flange-90 mm
Flange 160 mm
Flange-250 mm.
Coupler-180 mm
Coupler-200 mm
Reduce-180mm X 160 mm
150mm dial Pressure gauge (Range 0-7kg/cm³] with glycerine filling inside the dial including brass cock and fitting complete [This cost includes 15mm, dia G.l. pipes and specials)
Suitable Kiosk box for cable connection of vertical multi stage Pumpmotor set with degree of protection IP 65 including suitable legs and 6 Nos. Al. Bus bar for 32 Amps and all necessary earthing arrangement and insulator as per direction of EIC
Making CC foundation for support of the kiosk box after excavating the earth upto a depth of 0.6 Mtr below the GL including supply of all materials complete with 12 mm thick cement plastering with net cement finishing complete as per direction of EIC (size: 3' x 1' x 5').
Making earthing arrangement as per following -
Making earthing arrangement by supplying 5/8" dia earth spike of 2 mtr long with galvanized bolts, nuts and washer etc including supply and fitting fixing 8 SWG GI wire and restoring the surface duly rammed as per direction and inter connection with earth spike to continue running earth on the top of the PCC pole complete and testing as per satisfaction and direction of EIC.
Installation of vertical multi stage Pumping machinery to newly sunk tubewell along with column pipes (as required), top cover, valves, and specials of above with protection pipe and supply of MS clamp, nut bolt, cable gland socket etc, making inerconnection of the pump delivery line to pump collecting main line near tubewell with supply of all necceasary pipe, reducer/enlarger, GI/MS specials etc. including brick, sand, cement, rod etc and laying & drawing of all actuator cable & cable protection pipe as required and all to complete the job including all connection & testing commissioning as per direction of EIC
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including moving, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Making concrete slab for covering above equipment for protection of valves and pipes with 12mm thick plaster and net cement finish complete.
Transportation of above materials from vendor to site
Add GST @ 18%
Add Cess @ 1%
ORIENTAL ENGINEERING CO. (BID ID -5572578)
HINDOL ROY (BID ID -5592634)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .