| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-Finance G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-Finance lowest bidder | |
| 2 | L2₹19.2 L+₹28,599 (1.51%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹19.6 L+₹68,424 (3.62%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹26.5 L+₹7.6 L (40.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹28.7 L+₹9.8 L (51.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Shiv Enterprises L3 | NEETU TRADERS (INDIA) L1 | M/s S.G. BUILDERS L4 | friends associeates L6 | PARMAR ENTERPRISES L2 | jain associates L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling rose, holder, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete | 615 | Per point | 1 ₹615 Lowest | 5 ₹3,075 | 9 ₹5,535 | 10 ₹6,150 | 9 ₹5,535 | 5 ₹3,075 |
| 2.00 | Taking out Unseviceable main switch DB,MCB DB existing Complete | 74 | Per point | 1 ₹74 Lowest | 5 ₹370 | 9 ₹666 | 50 ₹3,700 | 99 ₹7,326 | 50 ₹3,700 |
| 3.00M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for | |||||||||
| 3.01 | All as per the description of srl no.03 here in before but One light point controlled by one switch of 6Amp | 150 | Per point | 400 ₹60,000 | 250 ₹37,500 | 275 ₹41,250 | 230 ₹34,500 | 219 ₹32,850 Lowest | 350 ₹52,500 |
| 3.02 | All as per the description of srl no.03 here-in-before but one fan point controlled by one, one way switch 06 Amps | 35 | Per point | 400 ₹14,000 | 250 ₹8,750 | 275 ₹9,625 | 230 ₹8,050 | 219 ₹7,665 Lowest | 350 ₹12,250 |
| 3.03 | All as per the description of srl no.03 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch | 20 | Per point | 120 ₹2,400 Lowest | 250 ₹5,000 | 275 ₹5,500 | 230 ₹4,600 | 219 ₹4,380 | 350 ₹7,000 |
| 3.04 | All as per the description of srl no.03 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch | 30 | Per Point | 400 ₹12,000 | 100 ₹3,000 | 160 ₹4,800 | 50 ₹1,500 Lowest | 89 ₹2,670 | 90 ₹2,700 |
| 3.05 | All as per the description of srl no.03 here in before but One bell point controlled by one bell push switch of 6Amp | 10 | Per point | 400 ₹4,000 | 250 ₹2,500 | 275 ₹2,750 | 230 ₹2,300 | 219 ₹2,190 Lowest | 350 ₹3,500 |
| 3.06 | All as per the description of srl no.03 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed | 50 | Per point | 550 ₹27,500 | 290 ₹14,500 Lowest | 499 ₹24,950 | 330 ₹16,500 | 299 ₹14,950 | 450 ₹22,500 |
| 4.00M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing through existing conduit pipe complete with replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for | |||||||||
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 May 2026, 6:00 pmClosed
GE North Delhi Cantt-10
GE North Delhi Cantt-10
WELCOME MAINTENANCE FOR INTERNAL ELECTRIFICATION OFFRS JCO AND ORS MD ACCN COD ME LINE CHEERING ENCLAVE AND TIMARPUR UNDER GE NORTH DELHI CANTT10
2026_MES_762288_1
GE/North-171/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE NORTH DELHI CANTT 10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT 10
₹80,000
Yes
5 Aug 2026
27 Apr 2026
27 May 2026
27 Apr 2026
25 May 2026
11 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling rose, holder, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete | 615 | Per point | - | - |
| 2 | Taking out Unseviceable main switch DB,MCB DB existing Complete | 74 | Per point | - | - |
| 3M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for | |||||
| 3.01 | All as per the description of srl no.03 here in before but One light point controlled by one switch of 6Amp | 150 | Per point | - | - |
| 3.02 | All as per the description of srl no.03 here-in-before but one fan point controlled by one, one way switch 06 Amps | 35 | Per point | - | - |
| 3.03 | All as per the description of srl no.03 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch | 20 | Per point | - | - |
| 3.04 | All as per the description of srl no.03 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch | 30 | Per Point | - | - |
| 3.05 | All as per the description of srl no.03 here in before but One bell point controlled by one bell push switch of 6Amp | 10 | Per point | - | - |
| 3.06 | All as per the description of srl no.03 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed | 50 | Per point | - | - |
| 4M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing through existing conduit pipe complete with replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for | |||||
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Gen171.pdf
Tender Documents • 1.00 MB
BOQ_853861.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .