| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC DADAWA KURIYAR KHAS BASTI BASTI UTTAR PRADESH 272178 | BASTI | UTTAR PRADESH | 272178 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.1 L+₹1.3 L (3.29%)Rejected-Finance 00 BEHIND CHARCH NAYAGOWAN LAKHERA BEHIND RAMA MANI DAIRY KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹44.6 L+₹3.8 L (9.30%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹44.7 L+₹3.9 L (9.47%)Rejected-Finance DAULAT NAGAR SOHALLA ROAD AJIJPUR DHANOLI AGRA UP PIN 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹44.7 L+₹3.9 L (9.47%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹42.8 L
EMD Value
₹85,700
Closing Date
3 Oct 2024, 6:00 pmClosed
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
PROVN OF 01 X TRG SHED (25 MTR X 8 TR) WITH ELECTRIC FITTING AT AMAR SINGH CAMP TRG AREA OF 6 PARA (SF) UNDER GE (EAST) AGRA
2024_MES_675361_1
9702/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹85,700
Yes
13 Nov 2024
19 Sept 2024
9 Oct 2024
19 Sept 2024
3 Oct 2024
26 Sept 2024
Amount
Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm grade in foundations, filling and mass concrete complete all as specified and directed.
M&L Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per Ser items No 4.00 above but 6mm to 8 mm dia complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M & L form work to soffits of suspended slabs such as floor or roof beam including support overhangs etc (horizontal or slopping ) complete all as specified and directed.
M&L RCC Design mix M-25 (20 mm graded stone aggregate) as in foundation, raft, footing, plinth beam, base for column etc complete all as specified and directed.
M&L RCC Design mix M-25 (20 mm graded stone aggregate) as in column complete all as specified and directed.
M&L RCC Design mix M-25 (20 mm graded stone aggregate) as in roof beams, chajja lintle etc complete all as specified and directed.
M&L RCC Design mix M-25 Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment , gusset plates, riveting etc, n exc 10 kg each brackets, conforming to Fe 290 Gd 165 complete all as specified and directed.
M&L Steel work in tubular post / other work including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 etc complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 15cm and n exc 22.5cm long of 20 mm dia complete all as specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
S&F of Pre- painted galvalume (PPGL) aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops shape complete all as specified and directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in all as 1:6 CM complete all as specified and directed.
M&L Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings, kerbs, benching and the like, including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering and rolled/rammed to a true surface complete all as specified and directed.
M&L hardcore of gauge exc.63 mm but not exc 100 mm deposited , spread and levelled in layers n exc. 15 CM thick, watered and rolled/rammed to a true surface
M&L Cement concrete 75 mm thick type C- 2, 1:3:6 (40mm graded aggregate) Stone Aggregate as in sub base of floor etc complete all as specified and directed.
M&L Cement concrete 75 mm thick type B-1, 1:2:4 (20mm graded aggregate) Stone Aggregate as in sub base of floor etc complete all as specified and directed.
M&L Glass dividing strips, 3 mm thick inserted in position conform to design complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement etc complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces at any height (not.exc 11mtr) complete all as specified and directed.
M&L preparation of newly surface of iron/steel with two coats synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed.
M&L 75mm thick PCC (1:3:6) type C1 using 20mm graded stone agg as in plinth protection/Path/paving surface even and smooth and and exposed edges fair or rounding or chamfering laid in panels with and including all necessary form work and filling the joints with mastic filling of one part of hot bitumen 85/25 grade and three part of fine sand (all by weight) including demolition of old PCC and removing rubbish to a distance n. exc. 100 mtr at low laying area complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick incl and over cement screed bed 20 mm thick in 1:6 cement and sand mortrar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and incl 10 mm thick cement screed bed 1:4 cement and sand mortrar, complete all as specified and directed.
M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand in repair complete all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit not less than 20 mm dia with all accessories and FRLSH PVC insulated 1.5 Sqmm multi standard unsheathed copper wire for continues earth, including cutting and chasing of wall surface for laying PVC conduit and modular sunken box and connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light point or one fan point controlled by one switch.
(b) One 5 pin socket outlet 5/6 Amps on independent board
(c) One 3 pin socket outlet 5 amps on the same board with other switches
All as per item No 37.00 here in before but with cable size 4 Sq mm for one socket out let on 16 Amp independent board and multistrand insulated copper earth continuity conductor of size 4 sqmm complete all as specified and directed.
Supply and fix switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply and fix Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate body complete all as specified and directed.
Supply and fix socket 5 amps 3 pin flush type, 240 volts. with polycarbonate body complete all as specified and directed.
Supply and fix socket out let, 6 pin 5 and 15 amps multipurpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd, complete all as specified and directed.
S&F ceiling rose, 3 phase/PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
Supplying and fixing 20 watt LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly pre-wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 VAC and safety extra low voltage safe level < 60 VDC as per IEC standard with LM 70 & 80 certification and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting, complete all as specified and directed.
Supply & fixing LED security light compact & trendy of 35 watt with aluminium pressure diecast housing, IP 65 protection, luminaire lumens > 3500 lumens and in built electronic driver prewire upto terminal block with driver efficiency > 85 %, power factor > 0.95, as per IEC 61000-3-2, colour temp 6500 K Surge protection 3.5 KV, 50000 burning hrs (min) as per L70 Criteria, multi stage constant current operated driver with range 150-270 VAC and safety exra low voltage safe load < 60 VDC as per IEC standards with LM 70 & 80 certification complete all as specified, fixed to pole or wall of buiding with and including suitable Bracket made out of 25 mm dia GI light grade pipe, 1.00 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitabe size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 Sqmm including all accessories and fixing arrangements for fixing the light fitting complete all as specified & directed.
Supply, fixing, connecting & testing ceiling fans complete with blades, down rods length as per site requirement, including fan hook with suitable size of clamp, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), including connecting wire with new 3 core 0.50 Sqmm PVC insulated and unsheathed copper conductor cable from ceiling rose complete all as specified and directed.
S&F Wall mounting fan, electric driven single phase 230 volts, oscillating type, 400 mm sweep, high quality ABS base with high speed motor and balanced blades with three leafed and 3 core copper cable of suitable size complete all as specified and directed.
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 12 way with IP-43 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
Supply and fixing MCB SP 5 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB SPN 40 to 63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. Notes :- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply and lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 2 Core, complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming complete all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks, locally available best quality laid dry in trenches for protection of underground cable complete all as specified and directed.
Supply and lay GI tube medium grade 40mm size as in cable protection pipe including all fittings complete all as specified and directed.
3Krishna Enterprises (BID ID -3126521)
Shiva Enterprises (BID ID -3127350)
aman construction & general suppliers (BID ID -3126789)
N.K. ENTERPRISES (BID ID -3126291)
Balaji Associate (BID ID -3124716)
M/S RADHEY GOVIND ENTERPRISES (BID ID -3126466)
SahaDevSingh Constructions (BID ID -3126456)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .