Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.8 LAccepted-AOC 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 1 | Accepted-AOC L1 | |
| 2 | 2₹17.8 L+₹3.0 L (20.4%)Rejected-Finance VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | 2 | Rejected-Finance NOT L1 | |
| 3 | 3₹19.5 L+₹4.7 L (31.6%)Rejected-Finance | 3 | Rejected-Finance NOT L1 | |
| 4 | 4₹20.3 L+₹5.5 L (37.4%)Rejected-Finance | 4 | Rejected-Finance NOT L1 | |
| 5 | 5₹20.7 L+₹5.9 L (40.0%)Rejected-Finance SCO 40 2ND FLOOR OMAXE WORLD STREET SECTOR 79 FARIDABAD FARIDABAD HARYANA 121004 | FARIDABAD | HARYANA | 121004 | 5 | Rejected-Finance NOT L1 |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
3 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Lucknow
229 MG Road CWE Lucknow
SPL REPAIR/CONVERSION OF 4 POLE STRUCTURE INTO RMU SYSTEM AT BASE HOSPUNDER GE E/M LUCKNOW
2022_MES_499862_1
CA NO CWE/LKO/EM/T-72 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE E/M LUCKNOW
₹47,000
Yes
14 Feb 2022
6 Jan 2022
4 Feb 2022
6 Jan 2022
3 Feb 2022
21 Jan 2022
60 days
Amount
Dismantling steel poles/struts any size and removing from site complete all as specified and directed.
Dismantling cross arms of MS channel or angle sections complete all as specified and directed.
Dismantling insulator any type and size and removing from site complete all as specified and directed.
Dismantling of ACSR conductor or AAC conductor complete all as specified and directed.
Dismantling air break gang operated switch vertical/horizontal mounted including insulator and operating machanisum for repair / replacement of brocken/ worn out components and insulators etc complete all as specified and directed.
Supply ,installation,testing and commissioning Single Incoming five outgoing 12KV, 630A, 21KA RMU Panel with Copper Bus bar FR1 - VI –6 way (0LBS +5VCB) RMU (Extensible ), fixed type 5 vacuum circuit breaker (Stainless Steel Tank), RMU provided will be Front Cable termination, Operating Sequence- 0-0.3s-CO-3 min-CO , Arrangement for 1 run/phase, main bus bar SF6 insulation is provided, Type tested according to IEC 62271-100, IEC 62271-200, IEC 62271-102 & IEC 62271-103 Safety Interlocks Extension : As per IEC : IAC AFL Internal Arc Fault withstand- 21kA-1s Rated Short circuit Making Current : 54.6 KAmp Power Frequency Withstand Voltage-28/38 KV(rms) : IP54, IP67 (Tank) Impulse Withstand Voltage (1.2/50 μs):95 KVp Extension: Both Side
Supply,laying,jointing,testing and commissioning HT under ground electric power cable crossed linked polyethylene (XLPE) insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11000 volts grade suitable for earth system of 3 core 95 sqmm cross sectional area , ISI marked as per IS 7088 Part-2, laid in trnenches/laid under floor/laid in ducts or fixed on poles etc complete all as specified and directed. Note- Excavation/boring of road/pipe shall be measured and paid separatetly under approriate items.
Excavation in trenches not exceeding 1.5 wide and not exceeding 1.5 m in depth for laying of cables, pipes and getting out incl trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed and making good disturbed surfaces.
Returning,filling in, including spreading, levelling and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soils) to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for river sand washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable incl spreading and levelling complete as specified and directed. Note- Punned down thickness will be measured for payment.
M&L unreinforced pre cast concrete cable cover comply with IS 5820:1970 and shall be of grade not lower than M20 HVP type-I with peak size 300x180x40mm laid dry in trenches for the protection of underground cable complete all as specified and directed.
Supplying and laying 80 mm bore GI tubing light grade for encasing LT cables for mechanical protection, laid under plinths /floors /roads /paths /culverts or fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I clamps with necessary bolts nuts and wasers etc complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.50 metre below normal ground level, connected to galvanized iron strip 32x6mm by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment /substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 15 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. Contd.....
Note for item No 14 : (i) Main earthing lead from earth plate electrode to test point upto length of 7.50 metre shall be deemed to be included in the unit rate quoted by the tenderer against this item. (ii) GI protection pipe and earthing strip beyond 7.5 mtr long shall be measured and paid seperatly. (iii) Test result should be less than 1 ohms or satisfaction of user.
M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in Cement concrete in foundations, filling and mass concrete etc incl necessary form work for rough finished surface complete as specified and directed.
M&L cable joint kit for 11 KV (earthed) grade cable for end termination indoor cold shrink type joint complete with jointing material and accessories sutable for XLPE armoured aluminium conductor cable of size 50-95 sqmm complete as specified and directed.
M/S A.R BUILDERS
Prime power system
K B ENTERPRISES
Systemic Electric Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .