| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.0 L+₹4.0 L (11.9%)Rejected-AOC DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-AOC Being Not L1 | |
| 3 | L3₹41.0 L+₹7.0 L (20.6%)Rejected-AOC | L3 | Rejected-AOC Being Not L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Enlisted as per NIT Category. Rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical WLR as per QE Sep more than 5 times of tendering limit Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
11 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer
Commander Works Engineer, Military Engineer Services Minniebay Junglighat Post Port Blair 744103
80989 Provn of Power Supply for Rapid Erect Sun Shelter RESS at INS Utkrosh Port Blair
2022_MES_553615_1
80989 PRVN OF POWER SUPPLY UTKOSH GE MINNIEBAY
Open Tender
Civil Works - Others
Item Rate
180 days
Port Blair
Class D b ii
8 documents required · 8 mandatory
₹500
GE Minniebay
₹80,000
Yes
26 Dec 2022
22 Sept 2022
18 Nov 2022
22 Sept 2022
11 Nov 2022
10 Oct 2022
Amount
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 to 120 sqmm all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 to 120 sqmm all as specified and direceted.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm all as specified and directed.
Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth strip 32 x 6 mm size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick and PCC chamber pit with PCC 1:3:6 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 all as specified and directed.
Excavation in soft loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed by Engineer-in-Charge
Returning filling soft & loose/hard & dense soil including spreading levelling, watering and well ramming in layers n exc 25 cms all as specified and directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point all as specified and directed by Engineer-in-Charge.
Excavation in hard / dense soil including road cutting etc not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed.
Supplying and laying in replacement of GI tubing medium grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position of following size all as specified and directed:-
100 mm dia
80 mm dia
M&L for providing cement concrete Type B1 1:2:4 (using 20mm graded aggregate ) as in coping, bedplates, foundation of RMU and transformer etc all as specified and directed.
M&L rendering 15mm thick in CM (1:4) on fair face of concrete external wall surfaces finished even and smooth (using extra cement)
Supply and laying of Telerex DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 110 mm and inner dia 95 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified. Make : Gemini/Rex Polyextrusion Ltd or equivalent as directed by GE
Supply and installation of copper wound step down transformer, outdoor type complete with standard fittings 3Ph 160KVA 11/0.433KV OCTC ((+)7.5% to (-) 7.5% @2.5%) Dyn11 Natural Ester Oil cooled level 2 transformers temp rise, impedance and losses shall conform to IS 1180 Level-II and equivalent IEC 62270. Radiators shall be Hot dip galvanized (HDG) to avoid corrosion. HV cable box and LV cable box as per specifications. Civil foundation as per OEM recommendations including following: (a) Lifting lugs/hooks, rollers for transformer and tank (b) Earthing terminal and rating and diagram plate (c) Air release device (d) Oil filling inlet pipe with plug (e) Drain outlet pipe with brass gate valve with dummy plug (f) Conservator with level gauge (g) Silica gel breather (h) First oil fill upto the recommended level by the manufacturer with new oil conforming to IS-339 (j) Type of connection: Delta/Star (k) Type of cooling: ONAN (l) Vector Group DYN 11 (m) Type of connecting arrangement cable termination boxes HT side and LT side (n) Provision of thermometer with pocket (o) Suitable foundation/platform as per manufacturer’s instructions to be designed and executed at no extra cost. Note:- In addition to the above all standard fitting to be provided as per latest IS norm also testing of the same in the presence of OEM representative at no extra cost.
Supply, installation, testing & commissioning of 11 KV, rated voltage 12KV, 630A, 21kA/3sec, Outdoor type, non extensible, Internal arc 21kA for 1 Sec for Tank, floor mounted with internal copper bus bars, SF6 Insulated, completely Motorised, 3 Way RMU consisting of 1 Nos VCB as incomer & 2 No 630A LBS as outgoing with SCADA compatible Overload and earth fault protection Relay (Ashidha/ CSPDR) with air insulated Metering module (MFM for VCB Feeders), All live parts, bus bars, LBSs connections of RMU shall be enclosed in one SF6 tank to avoid multiple interconnections, SF6 Tank shall be sealed for life robotically welded non magnetic and non ferriete stainless steel Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. 1 No Fault Passage Indicator (FPI) required for complete Unit. Manual welding or hermetic sealing of tank shall not be accepted. The unit shall have front cable entry (Suitable for termination of 1R x 3C x 95/ 120/150 Sqmm Cable) for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Bushing bolted type top mounted outside the tank for connection of external bus bar. (item 14 Contd/...)
Also, the outer enclosure shall cover the full length of the switchgear to ensure IP3X+IP54 protection for cable boxes. The unit shall be internal arc proof 21KA for 1 se with AFLR clasification, tested and totally safe for human beings. The gas release & personnel safety from internal arc shall not depend on plinth design. The release of gas to be from the top of the unit so that, even if the person is operating the unit, opening the cover & there are personnels near the sides of the RMU /plinth, top release will ensure their safety. The hot gas release, in case of an internal arc, in no case should be from any side or bottom of the unit, as the same is unsafe for the operating personnel/ pedestrian or general public. Bidder shall provide type test report to prove compliance to the Internal Arc fault IAC-AFLR as per IEC 62271-200. Internal arc testing shall be done with enclosure door in open condition, with switching devices in operation mode as per specified standard by Engineer-in-Charge. RMU Makes: Lucy Electric India Pvt Ltd./ABB/Schneider/L&T/C&S Electricals/Voltech System & Switchgear
Design, Supply, installation,testing and commissioning factory fabricated out door type totally enclosed LT cubical out door panel board suitable size with busbar, conforming to relevant IS and protection class IP-65, dust, vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated, mounted on 40x40x5mm MS angle iron frame, duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of redoxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate, panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables, locking arrangement,including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge.including Supply and fixing the following :- (Item No.15.00 Contd.../-)
Supply,laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core, laid in duct / fixed on wall/trenches compete all as specified and directed by Engr-in-charge.
Supply ,laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 Sqmm 3.5 core, laid in duct / fixed on wall/trenches all as specified and directed by Engr-in-charge.
Supply, laying of Telerex DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm and inner dia 103.50 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified. Make : Gemini/Rex Polyextrusion Ltd or equivalent as directed by GE
Design, Supply, installing testing and commissioning factry fabricated out door type totally enclosed LT cubicle out door panel board suitable size with bushbar, confirming to relevant IS and protection class IP-65, dust, vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated, mounted on 4-X40X5mm MS angle iron frame, duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of redoxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm grade stone aggregate panel base to be 500mm above ground level with suitable compartments for controls and monitorsincluding cable glands for incoming and outgoing cables, locking arrangement, including accommodating, supply and fixing the following accessories / items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi standed complete all as specified and as directed by Engr-in-Charge including supply and fixing the following:- (Item No.19.00 Contd.../-)
Supply & fix GI earth continuity conductor or main earthing lead of size 32X6mm fixed to wall on batten or recess or chases or buried in groun or drawn in conduit / pipe or fixed to any other indicated situation for earthing etc. as required complete all as directed.
Sree Tirumala Enterprises
SHUSHANT ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .