Executive Engineer, BMD, PHED
Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Rectification and maintenance of 04 (four) nos Transformer at 33/6.6 KV substation at Intake Kukrakuri of Chatna Saltora Block sub-surface based w/s scheme under Bankura Mechanical Division,PHE Dte
2025_PHED_870873_7
WBPHED/EE/BMD/NIeT-8 OF 2025-2026
Open Tender
MECHANICAL
Item Rate
60 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹30,000
Yes
9 Oct 2025
7 Jul 2025
25 Jul 2025
7 Jul 2025
22 Jul 2025
7 Jul 2025
Amount
TRANSFORMER – 1 (33 / 6.6 KV) OLTC :
Fixed Contact Connected with HT taping of Transformer as per existing size and specfication.
Main Moving Contact Assly connected with HT taping of Transformer as per existing size and specfication.
Resistor Moving Contact Assly connected with HT taping of Transformer as per existing size and specfication.
Transition Resistance Assembly for protecting transformer open ckt. at the time of changing tap position from one tap to another tap as per existing size and specfication.
Energy Accumulator for force tap changing ( if spring energized).Model EN16. make CTR.
Bearing Plate Assembly Supply (standard) Model EN16 make-CTR.
Tap position indicator switch .Model TC-5211A make-CTR.
Automatic Voltage Regulating Relay (Digital display) model AFTSE1800RS.Make : Ascensor
Top & Bottom Gasket ,oil seal as per sample.
Dehydration & Filtration of Transformer Oil by heat run process for improvement of IR Value(minimum 60KV/mnt) by the hiring of Filtering Machine & Testing Machine & Kit etc as per I.E Rules. (Transformer oil will be supplied from Departmental office )
Rectification of OLTC by removing the cover disconnecting the HT /LT cable assembly and throughout checking of existing circuits and switchgears items,changes of switchgear items (if any) , checking the controll circuits of RTCC, removing defective parts and refitting of the above spares of item sl no 1 to 9 in existing position by expart person of the subjected field and testing checking for a certain period with measuring the standard values of the transformer as per direction of EIC.
TRANSFORMER – 2 (33 / 6.6 KV) OLTC :
Fixed Contact Connected with HT taping of Transformer as per existing size and specfication.
Main Moving Contact Assly connected with HT taping of Transformer as per existing size and specfication.
Resistor Moving Contact Assly connected with HT taping of Transformer as per existing size and specfication.
Transition Resistance Assly for protecting transformer open ckt. at the time of changing tap position from one tap to another tapas per existing size and specfication.
Epoxy Arm as per existing size and specfication.
Energy Accumulator for force tap changing ( if spring energized) Model EN16. make CTR.
Bearing Plate Assly Supply (standard) Model EN16 make-CTR.
Braided wire for Main Moving Contact and Resistor Moving Contact as per existing size and specfication.
Tap position indicator switch .Model TC-5211A make-CTR.
Retaining Switch (DSS).model ZM23 make- CTR.
Motor Protection Relay (Thermal overload) as per sample .Model SR30/SR20 BCH or similar type.
Automatic Voltage Regulating Relay (Digital display) model AFTSE1800RS.Make : Ascensor.
Top & Bottom Gasket,oil seal as per sample.
Dehydration & Filtration of Transformer Oil by heat run process for improvement of IR Value(minimum 60KV/mnt) by the hiring of Filtering Machine & Testing Machine & Kit etc as per I.E Rules.(Topup Transformer oil will be supplied from Departmental office )
Rectification of OLTC after removing the cover plate and disconnecting the HT /LT cable assembly and throughout checking of existing electro mechanical parts and switchgears items,dismantling of defective parts, checking the controll circuits of RTCC panel and refitting of above items of sl no 1 to 9 at existing place by expart person of the subjected field and testing checking for a certain period with measuring the standard values of the transformer as per direction of EIC.
TRANSFORMER (3150 KVA, 33 KV / 6.6 KV) :
Supply delivery of cast Allluminium boady 2 Kgs Elysian Blue Color Silica Gel dry and desiccant crystals type in the Breather of above transformer as per direction
"Dehydration & Filtration of Transformer Oil by heat run process for improvement of IR Value(minimum 60KV/mnt) by the hiring of Filtering Machine & Testing Machine & Kit etc as per I.E Rules.(Topup Transformer oil will be supplied from Departmental office ) (3360 ltrs. X 2 nos. trf.)
Charges for Di-Electric Strength Test (BDV Test) by the hiring of Testing Machine & Kit etc as per I.E Rules.
OLTC and main Transformer body De-Rusting and Painting including Paint supply and hiring of spray painting machine
TRANSFORMER (500 KVA, 33 KV / 0.433 KV) :
Supply delivery of cast Allluminium boady1 Kgs Elysian Blue Color Silica Gel dry and desiccant crystals type in the Breather of above transformer as per direction
"Dehydration & Filtration of Transformer Oil by heat run process for improvement of IR Value(minimum 60KV/mnt) by the hiring of Filtering Machine & Testing Machine & Kit etc as per I.E Rules.(Transformer oil will be supplied from Departmental office ) Transformer – (2230 ltrs. X 2) = 4460 Ltrs. OLTC – (730 ltrs. X 2) = 1460 Ltrs.
Charges for Di-Electric Strength Test (BDV Test) by the hiring of Testing Machine & Kit etc as per I.E Rules.
OLTC and main Transformer body De-Rusting and Painting including Paint supply and hiring of spray painting machine
Attending fault at Kukrakuri Intake, with carrying different Testing, Servicing kit/machine like Insulation Resistance Checking machine (1 KV, 2.5 KV, 5 KV) 3 Phase Variac, Current Injection machine/ kit, Blower, Multimeter, Clamp meter, Different type of tools tackles, Various Testing Wires, MCBS, Wires & Cables, HT insulation Tapes, Gas can with nozzle, CRC, WD-40, Lecta Cleaner, Adhesive non Adhesive PVC Tape and items for complete servicing and testing the Transformers, VCBS, AVR etc .
Add: 18% GST
Add: 1% Cess
WEST BENGAL ENGINEERING CO. (BID ID -6735913)
B T PROJECTS PRIVATE LIMITED (BID ID -6740501)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .