Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.8 LAccepted-AOC 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹19.3 L+₹2.2 L (12.7%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹20.0 L+₹2.9 L (16.8%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹22.8 L+₹5.7 L (33.2%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹26.7 L+₹9.6 L (55.9%)Rejected-Finance | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
22 Jun 2022, 6:00 pmClosed
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Pin-208008
SPL REP/ REPLACEMENT OF LT CABLE AND RING MAIN SYSTEM AND ALLIED WORKS AT 24 ED (AF) UNDER AGE (I) AF MANAURI
2022_MES_526320_1
CA No.CWE(AF)/CHK/MNR/T-07 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE (I) AF Manauri
Class E Cat b ii
8 documents required · 8 mandatory
₹500
AGE (I) AF Manauri
₹48,000
7 Jul 2022
25 May 2022
24 Jun 2022
25 May 2022
22 Jun 2022
9 Jun 2022
Amount
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5mtr in depth for laying of cable etc and getting out in soft/loose soil, complete all as specified and directed. (NOTE: Excavation & earthwork for cables shall be carried out by JCB or manual method as per direction of Engineer-in -Charge).
Returning & filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM thick in soft/ loose soil, complete all as specified and directed.
Removing excavated material not exceeding 50 Mts and deposting where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed.
M&L for sand cushioning (dry sand) to under ground cable for cable protection with layer of 8 cm deep before laying the cable and 15 cm depth after laying the cable, complete all as specified and directed. Note : Punned thickness of sand layers shall be measured and paid . (NOTE : Punned thickness of sand layers shall be measured and paid).
M&L for brick, subclass 'B' well burnt, laid dry flat in trenches for protection of cable over LT/HT cable, complete all as specified and directed.
Supply, laying, testing & commissioning of LT XLPE insulated, screened, PVC bedded galvanised steel strip of wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade of cross sectional area 16 Sqmm 4 core (earthed) laid in trenches/ in ducts/encased GI pipe/fixed on poles etc including necessary lugs, thimbles & glands complete all as specified and directed. (Note:- (i) Excavation & earthwork, sand cushioning, brick protection, GI protection pipe shall be measured and paid separately under respective items.)
All as above item No-6 here-in-above but size 25 sqmm x 4 core (earthed)
All as above item No-6 here-in-above but size 35 sqmm x 3.5 core (earthed)
All as above item No-6 here-in-above but size 50 sqmm x 3.5 core (earthed)
All as above item No-6 here-in-above but size 70 sqmm x 3.5 core (earthed)
All as above item No-6 here-in-above but size 95 sqmm x 3.5 core (earthed)
All as above item No-6 here-in-above but size 120 sqmm x 3.5 core (earthed)
All as above item No-6 here-in-above but size 185 sqmm x 3.5 core (earthed)
M&L boring of holes under road, pavement, hard standing by manual method for inserting 80 to 100 mm dia light grade GI tube pipe for cable protection complete all as specified and directed. (Note: GI pipe shall be laid minimum 1.0 mtr below the natural GL as per site requirement and to be paid separately. Quoted rate shall be deemed included the cost of material & labour required for making good as per existing surface).
Supply and fixing to steel water tubing 40 MM bore, galvanised, light grade with and including all fittings accessories such as clamp (02 Nos) complete and laid in trenches, under road crossing, fixed on poles/walls for cable protection complete all as specified and directed.
All as above item No-15 above but of size 50 mm bore
All as above item No-15 above but of size 80 mm bore
M&L for earthing with galvanised cast iron earth plate of size 600 MM x 600 MMx 6 MM thick burred directly in ground not less than 2.25 Mtr below normal ground level, earth plate packed on all side with charcoal mixed wih salt to a thickness of 150 MM connected by GI earth strip of size 32 MM x 6 MM thick soldered and rivetted to earth plate. GI earth strip will be protected by using 50 MM bore light grade GI pipe from earth plate to be connecting objects including flat iron clamp 25 MM x 3 MM including bolts nut and washers complete including watering GI pipe 25 MM dia light grade 2.5 Mtr long the earthing include PCC pit including necessary earth work and disposal of surplus soil to a distance not less than 50 Mtr, chamber of PCC (1:4:8) type D2 using 40 MM graded stone aggregate, coping shall be PCC(1:3:6) type C1 using 20 MM graded stone aggregate, RCC pit cover 50 MM thick (1:2:4) type B1 using 20 MM graded stone aggregate, reinforced with 8 mm dia TMT bar at 80 MM C/C both way in lieu of CI pit cover and angle iron frame including funnel, wire mess, GI earth strip of size 32 MM x 6 MM under the earth and on the pole upto height of 1.5 Mtr shall be protected by 50 MM dia GI pipe (Light grade) GI pipe to be fixed with connecting objects by means of 2 Nos flat iron clamps 25 MM x 3 MM size complete with bolts, nuts, washers etc including testing and including dismantling of existing earthing complete all as specified and directed and shown in electrical plate No 3 of MES SSR part -I 2009. Note :- Quoted rates shall be included the cost of earthing strip in size 32 x 6 MM length upto 7.5 Mtr (as directed) with drawn through in GI pipe in 50 MM dia of bore including earth work as site required and directed.
Supply, Install, testing and commisioning of LT Panel in cubical housing cabinet, out door type, platform mounted (minimum height 40 cm above normal GL and 30 cm below normal GL) , CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 MM thick CRCA MS sheet of overall indicating size 1200 x 900 x 450 MM and full built upon angle iron frame in size 40 x 40 x 6 MM, having front and rear hinged both side openable doors and liffting lugs (02 Nos) , locking arrengement to be connect to earthing strip at rear side, bottom detachable both side openable ,gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuit shall be connected by multi strandered copper conductor flexible wire 1.5 Sqmm in proper colour coading and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase,4 wire system ,suitable rating CTs and PTs . internal connection shuold be made by copper strip in suitable rating ,making incoming and outgoing connection using gland in suitable size including grouting KIOSK on floor (60 CM above the ground surface) in floor angel iron 50 x 6 MM imbeded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20 MM grade stone aggregate complete comprising the following items:-
(a) 04 Nos bus bars equal size made out of aluminium strip in colour coating 600 Amps rated mounting on both side heat shrinkable insulators and PVC sleeving. -01 Set (b) LED indicating lamps of 'R' 'Y' and 'B' phase. Set of three -01 (c) Digital volts meter rating 3 phase class 1 - 01 No (d) Digital Ammeter rating 3 phase 1A class 1 - 01 No (e) Digital kWh (Energy) Meter rating 3 phase 4 W, 5 A class 1 with RS 485 port - 01 No (f) MCCB ,250 Amps rated, 4 pole, TPN, 415 volts grade , 36 KA breaking capacity microprocessed based operated - 01 Nos (As main incommer) (g) MCCB ,100 Amps rated, 4 pole, TPN, 415 volts grade , 16 KA breaking capacity thermal magnetic based oprated - 05 Nos (out going ,01 No as stand by) Note : (i) Panel drawing shall be approved by Deptt for size and all Tech specification before placing order (ii) All MCCB shall be confirming to Icu 100% and IEC 60947 -2 in compact series
Supply, Install, testing and commisioning of LT feeder Pillar box in cubical housing cabinet, out door type, for making connection juction point platform mounted (minium height 40 cm above normal GL and 30 cm below normal GL) , CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 MM thick CRCA MS sheet of overall indicating size 900 x 650 x 450 MM and full built upon angle iron frame in size 40 x 40 x 6 MM, having front and rear hinged both side openable doors and liffting lugs (02 Nos) , locking arrangement to be connect to earthing strip at rear side, bottom detachable both side openable ,gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuit shall be connected by multi strandered copper conductor flexible wire 1.5 Sqmm in proper colour coading and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase,4 wire system ,suitable rating CTs and PTs making all connection using gland in suitable size including grouting KIOSK on floor (60 CM above the ground surface) in floor angel iron 50 x 6 MM imbeded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20 MM grade stone aggregate complete comprising the following items:-
(a) 04 Nos bus bars equal size made out of aluminium strip in colour coating 600 Amps rated mounting on both side heat shrinkable insulators and PVC sleeving. -01 Set (b) LED indicating lamps of 'R' 'Y' and 'B' phase. Set of three -01 (c) Digital volts meter rating 3 phase class 1 - 01 No (d) Digital Ammeter rating 3 phase 1A class 1 - 01 No (e) MCCB ,125 Amps rated, 4 pole, TPN, 415 volts grade , 25 KA breaking capacity microprocessed based oprated - 01 Nos (As main incommer) Note : (i) Panel drawing shall be approved by Deptt for size and all Tech specification before placing order (ii) All MCCB shall be confirming to Icu 100% and IEC 60947 -2 in compact series
M&L for LT panel plinth foundation work using cement concrete in ratio 1:2:4 as required with brick in minium size 1.5 Mtr X 0.9 Mtr X 0.70 Mtr ( 40 CM above and 30 CM below in normal GL) including plastering in various location given by Deptt complete all as specified and directed.
S&F in replacement to shock proof, fire retardant rust proof, out door pole kiosk box of size 295 x195 x100 MM made out of one piece Engineer plastic moulding of siemens grey colour with in built 4 aluminium strip of 60 Amp rating fitted on DMC unbrakable insulator with MCB SPN 40 Amp including fixing arrangement as clamps made out by GI strip in size 32 x 6 MM and nut bolts washer with painting in two coat syenthic enamel paint over one coat of red oxide primer etc all complete all as specified and directed. Note : Quoted rate shall be including the cost of fixing arrangement of KIOSK box with pole.
Supply and fixing three core copper flexible wire, PVC insulated sheathed copper conductor muiti strandard in 1.5 Sqmm size for making inter connection of street/ road light fittings from control box to fittings drawn through in steel tubular pole including lugs / thimbles in required size etc all as site complete all as specified and directed.
Supply and fixing in repair LED street/ Bldg security light fittings 60 watts energy saving incl making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings and mounting bracket made out by GI pipe light grade in 25 mm dia of bore in required length bend in 120 degree fixed with clamp made out by GI strip in size 32 x4 mm using nut bolt and washer etc complete all as specified and directed. Make ; Bajaj /Philips/ Crompton/Havells Note : Quoted rate shall be including the cost of GI bracket & clamp.
Supplying,fixing,cutting, welding,jointing etc to HT/LT cable route indicator made out by MS angle 60 CM long in size 40 MM x 40 MM and 5 MM thick as stand and 6 inch dai with 5 MM thick rounded incating plate continious welding on top edge of stand incl painting in two coats using synthetic enamel paint over one coat of primer red oxide and stand grouting in cement concrete brick foundation minimum 30 CM etc to be fixed on existing route given by AGE (I) office including taking out the same complete all as specified and directed. Note : (i) Indicating sign shall be embossed on MS round plate and cement concrete measured against respective item. (ii) Quoted rate shall be included cost for required earth work to trace the correct route of cable.
Labour for removing of ACSR,Insulators,GI wire,stay assembly of OH line minimum 04 runs in proper coil winding with connecting accessories such as insulator, cross arms etc all as site deposting in MES yard complete all as specified and directed.Note:- Each span of ACSR conductor should not be less than 30 meters.
M/S VIJAY SINGH
shubham construction
HIMANSHU TRADERS
M/S Garg Sons
M/s DKS Engineering Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .