Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC | L1 | Accepted-AOC Due to lowest bidder | |
| 2 | L2₹25.7 L+₹1.1 L (4.56%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Due to not lowest bidder | |
| 3 | L3₹28.2 L+₹3.7 L (15.0%)Rejected-Finance RIDMALSAR PUROHITAN BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L3 | Rejected-Finance Due to not lowest bidder | |
| 4 | L4₹28.6 L+₹4.1 L (16.7%)Rejected-Finance | L4 | Rejected-Finance Due to not lowest bidder | |
| 5 | L5₹28.7 L+₹4.2 L (17.2%)Rejected-Finance GALI NO 20 RAMPURA BASTI BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L5 | Rejected-Finance Due to not lowest bidder |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
3 Jun 2025, 6:00 pmClosed
GE (N) BIKANER
GE (N) BIKANER RAJASTHAN
REPAIR REPLACEMENT TO ELECTRIC WIRING AND CONECTING WORK ELECTRICAL WORKS TO TEMP BUILDINGS AT MIL STATION AT UNDER GE N BIKANER
2025_MES_707100_1
GE (N) BKN-TOKEN/87/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE (N) BIKANER
As per Tender Documents
6 documents required · 6 mandatory
₹500
GE (N) BIKANER
₹81,000
Yes
17 Jul 2025
8 May 2025
10 Jun 2025
8 May 2025
3 Jun 2025
22 May 2025
Amount
Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed.
Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed.
Taking down old U/S existing DB TPN 4 way and DB SPN 8 way including MCB/MCCB of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through Existing PVC conduit including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length.
M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through PVC concealed conduit of suitable size including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length.
M & L for submain (single phase) wiring complete with and including 4.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through Existing PVC conduit including accessories and fixed on walls and 4 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 4.0 sqmm PVC insulated wire and one run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit length.
M & L for submain (single phase) wiring complete with and including 4.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through PVC concealed conduit of suitable size including accessories and fixed on walls and 4 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 4.0 sqmm PVC insulated wire and one run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit length.
S&F MCB TPN DB,4 way Vertical type,440V,3 phase with rated busbar 100 Amps, double door type suitable for MCCB as a incomer and MCBs as out going double door type ,grouted in walls with Fixing arrangemant complete all as specified and directed. Make-Legrand cat No-5077 50 or equivalent in C&S,Havells, bentex
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 12 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 8 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 4 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S & F MCB SPN, 6-32 Amps, 240 volts, breaking capacity 16KA complete all as specified and as dircted by Engr-in-charge.
S & F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
S&F MCCB 63 amps, 4 pole, 415 volts, adjustable type both short circuit & overload protection breaking capacity 16KA complete all as specified and as directed by Engr-in-charge.
S&F MCCB 100 amps, 4 pole, 415 volts, adjustable type both short circuit & overload protection breaking capacity 25KA complete all as specified and as directed by Engr-in-charge.
S&F MCCB 125amps, 4 pole, 415 volts, adjustable type both short circuit & overload protection breaking capacity 25KA complete all as specified and as directed by Engr-in-charge.
S&F MCCB 200amps, 4 pole, 415 volts, adjustable type both short circuit & overload protection breaking capacity 25KA complete all as specified and as directed by Engr-in-charge.
S&F MCCB 250amps, 4 pole, 415 volts, adjustable type both short circuit & overload protection breaking capacity 25KA complete all as specified and as directed by Engr-in-charge.
S&F MCCB 63 amps, 3 pole, 415 volts, adjustable type both short circuit & overload protection breaking capacity 25 KA complete all as specified and as directed by Engr-in-charge.
S&F MCCB 100 amps, 3 pole, 415 volts, adjustable type both short circuit & overload protection breaking capacity 16KA complete all as specified and as directed by Engr-in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion.
M & L for point wiring with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 1.5 sqmm 1100 volts grade drawn through and including suitable size of PVC concealed conduit with accessories with laminated top cover fixed on MS sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge for the following :- (a) One Light/fan/ex-fan point controlled by one switch.
(b) one socket point on the same board with other switch complete.
(c) One 3 pin 5 amps socket on independent board.
Ditto all as per item No-26 above but with 2.5 sqmm copper wire for 3 pin socket outlet 15 Amp on independent board complete and all as directed by Engr-in-charge.
Ditto all as per item No 26 above but but one light point controlled by two 02 way switch board complete and all as directed by Engr-in-charge.
S&F switch piano type, 5 Amp, single pole one way, 230 Volts, flush type complete all as specified and as directed by Engr- in -charge.
M&L Switch piano flush type single pole, one way 15 Amps 230 Volts complete all as specified & directed by Engr-in-Charge.
S&F switch piano type, 5 Amp, single pole two way, 230 Volts, flush type complete all as specified and as directed by Engr- in -charge.
M&L socket outlet 3 Pin, 5 Amps flush type 230 Volts complete all as specified and directed by Engr-in-Charge.
M&L for socket outlet 2 in 1, 3 Pin, 5 & 15 Amps, 230 Volts t complete all as specified & directed by Engr-in-Charge.
M&L single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 Amp complete all as specified & directed by Engr-in-Charge.
S&F ceiling rose, surface backelite , three terminal AC, 230 volt complete all as specified.
supply and fixing fan regulator electronic socket type five step controlled 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.
Supply and fixing Bell push, flush type, 5 amp 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with LED bulb 9 watt complete all as specified and directed by Engr-In-Charge.
Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m width for laying of cable lines and pole etc and getting out in hard/ dense soil complete all as specified.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed by Engr-in-charge.
Supply and laying Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) all complete as specified and as directed.
Supply and laying bricks (old size) for cable protection by using common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry flat across length of the cable and all as directed.
M&L for GI tubing 40 mm dia light grade with all necessary flxed to walls, poles, under road/floor etc for cable protection complete all as specified and directed.
S&F MCCB 40 amps, 4 pole, 415 volts, fixed type breaking capacity 16KA complete all as specified and as directed by Engr-in-charge.
M/s Rohit Construction Co. (BID ID -3306139)
S S CONSTRUCTION COMPANY (BID ID -3304923)
PUNIYA POWER CONSTRUCTION (BID ID -3312369)
ENGINEERS POWER CONSTRUCTION COMPANY (BID ID -3306369)
BIDAWAT ENTERPRISES (BID ID -3312200)
G R POWERS (BID ID -3306171)
DEVARAM CONSTRUCTION COMPANY (BID ID -3304764)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .