| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹12.0 L+₹1.3 L (12.6%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹13.5 L+₹2.8 L (26.5%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹18.5 L+₹7.8 L (73.6%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Dec 2019, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIR / MAINT OF INTERNAL WIRING AND CONNECTED WORKS FOR MD ACCN AT LGJ MIL STN
2019_MES_299784_2
8930-23/19-20
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
Class E Cat (b)(i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹40,000
Yes
28 Feb 2020
9 Dec 2019
31 Dec 2019
9 Dec 2019
28 Dec 2019
12 Dec 2019
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sketch fitting, sockets, regulator, rusted conduit etc and making good disturbed surfaces of walls and floors etc to match with the existing all as specified and directed by Engineer-in-Charge.
Taking down carefully submain wiring / service connection of any type complete with casing caping / conduit etc complete all as specified and as directed by Engineer-in-charge.
Taking down MCB with sheet metal enclosure, main switch, DB, etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engineer in Charge.
M&L point wiring with 1.5 Sqmm FRLS (nominal cross section area) PVC insulated unsheathed multistranded copper conduct cable in and including medium grade rigid PVC concealed conduit in wall after cutting chases in wall including cast iron or pressed steel terminal box covered with and including 3 mm thick bakelite sheet top cover fixed flush with wall using brass screws, washers and 1.5 Sqmm single core PVC insulated unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point controlled by one switch and making good diturbed surfaces complete all as specified and directed by Engineer-in-Charge.
,-----ditto---- All as per srl item No 4 above, but for one ceiling/exhaust fan point controlled by one switch and regulator, complete all as specified and directed by Engineer-in-Charge.
,-----ditto---- All as per srl item No 4 above, but for One bell/buzzer point controlled by one bell push, complete all as specified and directed by Engineer-in-Charge
,-----ditto---- All as per srl item No 4 above but for one three pin 5 Amps socket outlet with 2 pin out let of 5 Amps on same board all as specified and directed by Engr-in-Charge.
,-----ditto---- All as per srl item No 4 above but for one three pin 5 Amps socket outlet with 2 pin out let of 5 Amps on independent board all as specified and directed by Engr-in-Charge.
,-----ditto---- All as per srl item No 4 above but controlled with two No. two way switches complete all as specified and directed by Engineer in charge.
Material and labour for point wiring with 1.5 sqmm,FRLS, single core PVC insulated, unsheathed, multistranded copper conductor cable, with universal colour code drawn in existing steel/PVC conduit/casing capping in existing sunken pressed steel terminal boxes, providing 3 mm thick plastic laminated sheet top cover including 1.5 sqmm PVC insulated, unsheathed, multistranded copper conductor cable as earth wire in green colour and making good the disturbed surfaces in cement mortar (1:3), complete all as specified & directed for light point controlled by one switch complete.
,-----ditto---- All as per srl item No 10 above, but for one ceiling/exhaust fan point controlled by one switch and regulator.
,-----ditto---- All as per srl item No 10 above, but for for bell point controlled by one bell push complete.
,-----ditto---- All as per srl item No 10 above, but for 3 pin 5 Amp socket outlet on the same board with other switch, sockets complete all as specified and as directed.
,-----ditto---- All as per srl item No 10 above, but for for 3 pin 5 Amp socket outlet independent complete.
,-----ditto---- All as per srl item No 10 above but point wiring with 4 sqmm multi stranded conductor cable and 4.0 sqmm unsheathed copper conductor earth wire for two in one 6 pin 15 Amps socket outlet on independent board all as specified and as directed by Engr-in-Charge.
,-----ditto---- All as per srl item No 10 above but point wiring with 4 sqmm multi stranded conductor cable and 4.0 sqmm unsheathed copper conductor earth wire for two in one 6 pin 15 Amps socket outlet on independent board all as specified and as directed by Engr-in-Charge.
Supply & fixing switch piano type flush button single pole one way 5/6 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
M&L in repair switch piano type flush button single pole one way 5/6 Amps, 230 volts including taking down old one complete all as specified & directed by Engineer-in- charge.
Supply & fixing switch piano type flush button double pole two way 5/6 Amps, 230 volts including taking down old one complete all as specified & directed by Engineer-in- charge.
Supply & fixing socket outlet 2 in 1, 3 pin 5 Amp,flush type including taking down old one complete all as specified & directed by Engineer-in- charge.
Supply & fixing bell push flush button 5/6 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
Supply & fixing switch piano type flush button single pole one way 15/16 Amps 230 volts complete all as specified & directed by Engineer-in- charge.
M&L in repair switch piano type flush button single pole one way 15/16 Amps 230 volts complete all as specified & directed by Engineer-in- charge.
Supply & fixing socket outlet two in one, 6 pin 5 Amp and 15 Amp flush type complete all as specified & directed by Engineer-in- charge.
Supply & fixing socket outlet two in one, 6 pin 5 Amp and 15 Amp flush type all as specified & directed by Engineer-in- charge.
S & F in repair sheet metal single pole and neutral enclosure 240 volts with a two pin and earth plug and socket complete with 20 Amp single pole MCB complete all as specified and as directed by Engr-in-charge. Make - Legend/Standared/Siemens
S & F Lamp holder including LED lamp 9 watt, insulated body with back plate etc complete all as specified and as directed by Engr-in-Charge.
Supply & fixing ceiling rose surface bakelite 65 mm x 50 mm size, 3 terminals complete all as specified and directed by Engineer-in-Charge.
S & F fan regulator electronic socket type 80/100 watt complete all as specified and as directed by Engr-in-charge. Make - Anchor/Usha/Kinjal/Legrend
Supply & fixing electric bell, ding dong, 230 volts AC supply complete all as specified and directed by Engineer-in-Charge. Make: Anchor/Khaitan/Cromption
Supply & fix in replair batton integrated LED light fitting 1x20 aluminium LED Channels with T-5 tube pre wired for LED tube fixed to roof/ceiling /wall with necessary wooden/PVC blocks etc and connecting with 2 core flexible PVC insulated multistranded copper conductor from ceiling rose to fitting including taking down old one complete all as specified and directed by Engr-in-charge. Make : Bajaj Cat Part No BCLSBAL20WCW or similar specifications in Crompton /Havells
Supply and fix in repair LED Tube Rod retrofit 18/21 watt 230 volt 50 Hz,T-8 lamp holder includind removing old tube rod 36/40 watt and making necssary alteration in existing fitting and making all electrical connection complete all as spercified and directed by Engr-in-charge. Make Bajaj Cat Part No BLRB18WCW LED or similar specifications in Crompton /Havells
S&F in repair surface mounted square LED down lighter 18 watt with aluminium frame LED panel high quality diffuser for uniform light and high efficiency of size 1x1 luminaire with driver and bottom opening complete all as specified and as directed by Engr-in-charge. Make : Bajaj Cat Part No BZSSQL18W or similar specifications in Crompton /Havells
Supply and fix in repair bulk head fitting with LED of 10 watt complete all as specified and directed by Engr-in-charge. Make : Bajaj Cat Part No BIBWP10WLED or similar specifications in Crompton /Havells
Supply and fix in repair Switch socket combination 2 in 1, 5 Amp flush type including taking down old one complete all as specified and directed by Engr-in-charge.
Supply and fix in repair Switch socket combination 5A/16A, 5 in 1 including taking down old one complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair modular Socket, 6A - 2/3 pin combined 2 module including taking down old one complete all as specified and directed by Engr-in-charge..
Supply and fix in repair modular Socket, 6A/16A - 2/3 pin combined 2 module incuding taking down old one complete all as specified and directed by Engr-in-charge..
Supply and fix in repair Modular switch 1 way 6 A, 1 module including taking down old one complete all as specified and directed by Engr-in-charge.
Supply and fix in repair Modular switch 1 way 16 A, 1 module including taking down old one complete all as specified and directed by Engr-in-charge.
S & F in repair factory made sheet metal distribution boards, SPN, 12 way double door; protection class IP-42 suitable for mounting MCB/ conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in- charge. Make Legrand / Havells/L&T.
S & F in repair factory made sheet metal distribution boards, SPN, 8 way; double door; protection class IP-42 suitable for mounting MCB/ MCCB, conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in- charge. Make Legrand / Havells/L&T.
S & F in repair factory made sheet metal distribution boards, SPN, 4 way; double door, protection class IP-42 suitable for mounting MCB, conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in- charge. Make : Legrand / Havells/L&T.
S & F in repair factory made sheet metal distribution boards, TPN, 4 way; protection class IP-42 suitable for mounting MCB/ MCCB, conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 415 volts AC supply complete all as specified & directed by Engineer-in- charge.
S & F in repair MCB tripple pole 63 Amp, 415 Volts 'C' series category, rupturing capacity 9 KA confirm to IS- 8828-1996, IEC - 60898 complete all as specified and directed by Engr-in-charge. Make : Legrand / Havells/L&T.
S & F in repair MCB SP 63 Amp, 240 Volts 'C' series category, rupturing capacity 9 KA confirm to IS- 8828- 1996, IEC - 60898 complete all as specified & directed by Engr-in-charge. Make - Legrand / Havells/L&T.
S & F in repair MCB SPN 32 Amp, 240 Volts 'C' series category, rupturing capacity 9 KA confirm to IS- 8828-1996, IEC - 60898 complete all as specified and directed by Engr-in-charge. Make : Legrand / Havells/L&T.
S & F in repair MCB SP 6 to 32 Amp, 240 Volts 'C' series category, rupturing capacity 9 KA confirm to IS- 8828- 1996, IEC - 60898 complete all as specified & directed by Engr-in-charge. Make Legrand / Havells/L&T.
S & F in repair MCB tripple pole & Neutral 63 Amp, 415 Volts 'C' series category, rupturing capacity 9 KA complete all as specified and directed by Engr-in-charge. Make: Legrand / Havells/L&T.
Sub main wiring with two single core PVC sheathed FRLS insulated cable of 6 sqmm size copper multi stranded conductor 1100 volts grade drawn-through and including 25 mm dia stove enamelled rigid steel conduit of adequate size of conduit and junction boxes,terminal boxs,terminal boxes and accessories such as tees, bend elbows, reducers, bell mouth tube ends fixed concealed in wall including one run of 4 sqmm copper conductor unsheathed multi stranded earth wire earth continuty conductor complete all as specified and directed by Engineer-in-charge. Note : Two run of single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with accessories shall be measured as one length.
Sub main wiring with Four single core PVC sheathed FRLS insulated cable of 10 sqmm size copper multi stranded conductor 1100 volts grade drawn-through and including 32 mm dia stove enamelled rigid steel conduit of adequate size of conduit and junction boxes,terminal boxs,terminal boxes and accessories such as tees, bend elbows, reducers, bell mouth tube ends fixed concealed in wall including one run of 6 sqmm copper conductor unsheathed multi stranded earth wire earth continuty conductor complete all as specified and directed by Engineer-in-charge. Note : Four run of 10 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with accessories shall be measured as one length.
S & F 1100 volts grade heavy duty PVC sheated FRLS insulated aluminium stranded conductor cable served with inner sheathing twin core flat or circular of size 10 sqmm in service connection & suspended by insulating hangers not more than 1 metre apart including 4 mm dia GI suspension wire complete all as specified & directed by Engineer-in-charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (iii) GI wire upto DBs earth connection is included in this item. (iv) Water pipe shall be provided in slanting position.
S & F LED building security light fitting 25 watt with epoxy powder coated sheet aluminium housing, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover and accessories complete including street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer after taking down old u/s one. Make of fitting : Bajaj Cat Pt No BCLST25WLEDIV2 or equivallent in Crompton/Havells.
Dismantling Ceiling fan/Exhaust fan any make/size for complete overhauling such as cleaning the blades and louver with detergent powder, inspecting the fan bearing/bush, cleaning with diesel/kerosene oil, Greasing/oiling all as specified and directed by Engr-in-Charge. Note : Bearing, bush, capacitor etc shall be measured and paid separately under respective items.
Supply and Fixing in replacement rubber reel including suitable size of bolt, nut and safety pin for ceiling fan of any make/size/model complete all as specified and as directed by Engineer-in- Charge.
Supply and Fixing in replacement ball bearing of No. 6201 suitable for ceiling fan complete all as specified and as directed by Engineer-in- Charge. Make :- SKF/NBC/INA/FAG/NSK.
Supply and Fixing in replacement ball bearing of No. 6202 suitable for ceiling fan complete all as specified and as directed by Engineer-in- Charge. Make :- SKF/NBC/INA/FAG/NSK
Supply and Fixing in replacement ball bearing of No. 6203 suitable for ceiling fan complete all as specified and as directed by Engineer-in- Charge. Make :- SKF/NBC/INA/FAG/NSK
S&F in repair condenssor 2.5 MFD 230 volt 50 Hz including taking down old one complete all as specified and as directed.
S&F in repair condenssor 4 MFD 230 volt 50 Hz including taking down old one complete all as specified and as directed.
Supply and fixing in replacement MCCB of capacity 250 Amp, 4 pole, 415 volt, short circuit breaking capacity not less than 25 KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc, including making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge. Make : Legrand/L&T/Crompton
Supply and fixing in replacement MCCB of capacity 200 Amp, 4 pole, 415 volt, short circuit breaking capacity not less than 25 KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc, including making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge. Make : Legrand/ L&T / Crompton.
Supply and fixing in replacement MCCB of capacity 100 Amp, 4 ploe, 415 volt, short circuit breaking capacity not less than 25 KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc, including making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge. Make : Legrand/ L&T / Crompton.
M&L for repair to door hinges of sheet metal cabinet of 22 SWG of CRCA of size 660 mm x 660 mm x 200 mm including necessary welding and painting the cabinet with two coat of synthatic enamelled paint over a coat of red oxide primer and rearanging all elctrical connection in the box complete all as specified and as directed by Engineer-in-charge.
S & F in repairs fresh air fan 200 mm sweep, single phase 230 volts 50 Hz including grouting with fasteners, nuts/bolts etc complete all as specified by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
Ganganagar Enterprises
Aggarwal brothers and company
GM Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .