| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹20.5 L+₹54,425 (2.73%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹32.5 L+₹12.5 L (62.6%)Rejected-Finance 361 D SHAKTI NAGAR NEAR KHAN DAIRY INDIRA NAGAR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹37.9 L+₹17.9 L (89.6%)Rejected-Finance 10 WARD NO 18 PLOT NO 34 KAMDENU FURNTIURE SIKAR RAJASTHAN 332025 | SIKAR | RAJASTHAN | 332025 | L4 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
24 Dec 2024, 6:00 pmClosed
LT COL VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/MAINT OF INTERNAL ELECTRIFICATION, FITTING AND FIXTURE AND ALL CONNECTED ITEMS AND COMPREHENSIVE MAINT/PETTY REPAIR IN COD ESTATE, ME LINE, NAPIER ROAD, VRG, HARDING ROAD UNDER GE (I) KANPUR
2024_MES_685782_1
GE(I)/KAN/T-89 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (I) KANPUR
₹78,000
Yes
3 Feb 2025
26 Nov 2024
31 Dec 2024
26 Nov 2024
24 Dec 2024
10 Dec 2024
Amount
Attending complaints to checking & replacing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item fuctional & replacing fuse ,small pieces of copper wire ,copper cable of suitable size at site ,insulation tape roll, etc.Attending minor repairs such as testing ,connectings fittings,nuts,bolts,screws,etc to emergent complaints i.e. no light ,earth laekage ,short circuit , neutral break in mains/sub mains/internal circuits of existings electrical systems of main buildings /blocks and making continuous electric supply including carrying out minor repairs to make system in order to functional with insulation tape roll, copper thimbles, glands,earthing,wire,as required at site complete all as specified and directed. NOTE :1. This item is applicable only where no store is required. 2. The site for attending complaints are COD Estate , ME line ,VRG line, Offr Qtr Napier road,Harding road.contractor should provide minimum one trademen (electrician) with helper for such site to attend the complaint in all working days between 0830 hrs to 1700 hrs including holiday and sunday. 3. Contractor shall insure the security passes for his staff , to be obtained from concern auth for attending complaints 4 The contractor will ensure that the electricians with necessary tool bag shall always remain present at complaint cell to attend the complaints. 5. A recovery of Rs 500/- for not attending the complaints upto 04 hrs and 04 hrs Rs 1000/- shall be recovered from the contractor. 6. The complaint slip, register & other connected documents will be provided by the contractor without any extra cost. 7. Proper date wise record of complaints received & rectified by the contractor and the same may be asked for verifiaction at the time of payment of each RAR/Bill.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power), including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete all as specified and directed.
M&L for Point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper colour coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green colour) as earth lead in and including concealed non metalic rigid PVC conduit medium grade of size 25mm dia with all fittings (ISI Marked) including CI/MS sunk box of required size & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
All as per item No 3 above but upto ceiling height and on surface at ceiling complete all as specified and directed.
All as per item No 3 above but in existing conduit complete all as specified and directed.
All as per item No 3 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in and including conduit complete all as specified and directed.
All as per item No 3 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in existing conduit complete all as specified and directed.
All as per item No 3 above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed.
All as per item No 3 above but for one 3 pin 5A socket outlet independent controlled by one switch in existing conduit complete all as specified and directed.
All as per item No 3 above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed.
All as per item No 3 above but for one light point controlled by 2 nos two way switches in existing conduit complete all as specified and directed.
All as per item No 3 above but for one light/fan/bell point including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed.
All as per item No 3 above but for one socket outlet 5 amps on indipendent board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed.
All as per item No 3 above but for one socket outlet 5 amps on same board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed.
All as per item No 3 above but for one light point controlled by two, two way switches including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed.
All as per item No 3 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in and including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 Sqmm with proper colour coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and directed.
All as per item No 17 above but in existing concealed conduit complete all as specified and directed.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 10 Sqmm with proper colour coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 10 Sqmm as earth lead in & including concealed PVC conduit medium grade 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or complete all as specified and directed.
All as per item No 19 above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit complete all as specified and directed.
All as per item No 19 above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm in existing concealed conduit with earth wire 4 sqmm complete all as specified and directed.
M&L for switch piano flush button single pole one way 5/6 amps 240 volts complete all as specified and directed.
S&F switch piano flush button single pole one way 15/16 amps 230 Volts complete all as specified and directed.
M&L for switch piano flush button single pole two way 5 amps 240 volts complete all as specified and directed.
M&L for bell push flush button single pole one way 5 amps 240 volts complete all as specified and directed.
M&L for socket out let 5 amps 5 pin flush type, 230 volts complete all as specified and directed.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts complete all as specified and directed.
M&L for ceiling rose surface bakelite 3 terminals complete all as specified and directed.
M&L for bell electric heavy duty Ding Dong type 230 volts single pole complete all as specified and directed.
S&F Lamp holder insulated body with back plate for dome batten fittings complete all as specified and directed.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed.
M&L for switch modular type single pole one way 1 module 6 amps 240 volts complete all as specified and directed.
S&F switch modular type one way 1 module 16 amps 230 Volts complete all as specified and directed.
M&L for switch modular type two way 1 module 6 amps 240 volts complete all as specified and directed.
M&L for bell push modular type 1 module one way 6 amps 240 volts complete all as specified and directed.
M&L for socket 6 amps modular type 2/3 pin combined 2 module, 230 volts complete all as specified and directed.
M&L for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts complete all as specified and directed.
S&F electronic regulator modular type one way 1 module 230 Volts complete all as specified and directed.
Supply & fix in concealed or fixed on wall of rigid non-metallic PVC conduit of size 25 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
S&F in replacement of wall mounted LED light fittings 20/22 watt, 6500K/4000K/3000K, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete connecting electrically complete all as specified and directed.
S&F in repair LED inverter lamp B-22 type of 09 Watt works on AC supply in normal dode and DSC supply in inverter mod, with inbuit battery backup to upto 4 hours, high effciency high lumes output complete all as specified and directed.
S&F in replacement of LED T- Bulb 10/12 W cool day white complete all as specified and directed.
S&F in replacement of LED light fitting recess mounted min 36 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling with integrated electronic driver and making electrical connection properly complete all as specified and directed.
Supply and fixing in replacement of 10W surface mounted IP65 Bulkhead with system efficiency of 100LM/Watt LED bulk head shall be made up of Die cast Aluminium housing for better heat decapitation.P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm and complete all as specified and directed.
Supply and fix in replacement of High power LED street light 25 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver including suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core aluminium cable PVC insulated complete all as specified and directed.
S&F in replacement Gate light fitting LED type 15 W with CCT not less than 6500K/3000K and IP 65 Protection ,230V recessed mounting mirror opticluminare with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Supply & fix in repair LED bollard light 8/9 w suitable for landscape lightening with high power LED as light source including making PCC foundations fixing with required fasterners, making electrical connections complete all as specified and directed.
Supply and fix in replacement recess monted LED down light 15 watt, square/round made from cast aluminium housing and opaque polymer diffueser for ptimum light etc complete all as specified and directed.
S&F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB 125 Amps as incommer, 415 Volts 3 phase 50 C/s VTPN DB 4 way with appropriate size copper bus bar and neutral link with one MCCB 3 pole 415 Volts 115 Amps rating with rupturing capacity 16 kA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed.
All as per item No 49 above but for VTPN DB 8 way with MCCB 160 Amps 4 pole 25 KA complete all as specified and directed.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
All as per item No 51 above but for 8 way complete all as specified and directed.
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 kA 'C' curve using thimbles of required size complete all as specified and directed.
M&L MCB single pole & neutral 240 volts 32 amps,with rupturing capacity 10 kA 'C' curve using thimbles of required size complete all as specified and directed.
M&L MCB single pole & neutral 240 volts 40 amps,with rupturing capacity 10 kA 'C' curve using thimbles of required size complete all as specified and directed.
M&L MCB single pole & neutral 240 volts 63 amps,with rupturing capacity 10 kA 'C' curve using thimbles of required size complete all as specified and directed.
M&L MCB triple pole & neutral 240 volts 40 amps,with rupturing capacity 10 kA 'C' curve using thimbles of required size complete all as specified and directed.
M&L MCB triple pole & neutral 240 volts 63 amps,with rupturing capacity 10 kA 'C' curve using thimbles of required size complete all as specified and directed.
S&F in replacement of MCCB 3 Pole 415 Volts 3 phase 100 Amps 16 kA, thermal magnetic release complete all as specified and directed.
S&F in replacement of MCCB 3 Pole 415 Volts 3 phase 125 Amps 16 kA, thermal magnetic release complete all as specified and directed.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables complete all as specified and directed.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed. Note:- Punned thickness shall be measured and paid.
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed.
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection cable & pipe upto 80 mm bore complete all as specified. Note: Depth of bore shall not be more than 1 Mtr from original ground level complete all as specified and directed.
Disconnecting electrically and taking out old unserviceable LT UG cables any type of size 16 Sqmm to 35 Sqmm 3.5/4 core complete all as specified and directed.
Supply and laying in trenches or fixing to wall/pole or passing through pipe XLPE PVC insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core complete all as specified and directed. (Note : Rate Incl for making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
All as per item No 68 above but cable of size 16 Sqmm 2 core complete all as specified and directed.
S&F in replacement of service wire 10 Sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, twin core cable flat or circular complete all as specified and directed.
Material and labour for GI tubing light grade of 50mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
M&L inreplacement for sheet metal enclosure suitable for AC/ Geyser , single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts with one single pole MCB of 20 amps earthing and complete all as specified and directed.
Supply and fixing in replacement ceiling fans with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor with remote complete all as specified and directed.
Supply & Fixing in replecement Exhaust fan iron body 300 mm sweep with fittings with suitable nut & bolts & connections to wall and old unsv deposited to store complete all as specified and directed.
Supply & Fixing in replecement air ventilator/fresh air fan plastic body 250 mm sweep with fittings & connections to wall complete and old unsv deposited to store complete all as specified and directed.
M&L in replacement of earthing with galvanised iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate and as specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion. Note:- Earthwork in any type of soil and removal of surplus soil upto 50 mtr distance where directed are deemed into quoted rate by the contractor.
AARADHIRAJ ASSOCIATES (BID ID -3191088)
Eco Creations (BID ID -3186183)
Ruchi enterprises (BID ID -3191404)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .