Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹33.9 L+₹1.1 L (3.30%)Rejected-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹39.7 L+₹6.9 L (21.0%)Rejected-AOC | L3 | Rejected-AOC Higher bid value | |
| 4 | L4₹42.0 L+₹9.2 L (27.9%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-AOC Higher bid value | |
| 5 | L5₹48.7 L+₹15.9 L (48.3%)Rejected-AOC | L5 | Rejected-AOC Higher bid value |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
6 Aug 2022, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
REPAIRS/ REPLACEMENTS TO SECURITY LIGHTS STREET LIGHTS AREA LIGHTS GATE LIGHTS AND CONTROLLING PANELS INCLUDING CONNECTING WORKS OMQ, GOLF AND SMQ AREAS AND REPAIR/ REPLACEMENT INCLUDING RE-WIRING OF DEFECTIVE WIRING, REPLACEMENT OF MCBs, DBs, SWITCH
2022_MES_537733_1
8890/GE/48
Open Tender
Civil Works
Works
270 days
GE (AF) BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (AF) BANGALORE
₹86,000
Yes
26 Sept 2022
13 Jul 2022
9 Aug 2022
13 Jul 2022
6 Aug 2022
23 Jul 2022
14 Jul 2022 - 20 Jul 2022
Amount
Taking down existing defective street light fittings of any description and of any type from poles/ walls of buildings of any height complete after disconnecting the electrical connections and re-fixing the same in position after replacement of defective/ unserviceable spare parts/ brackets etc., including connecting up and testing for satisfactory functioning, complete all as specified and as directed.
Taking down existing defective flood light/ CFL/LED/ post top lelten fittings of any description and type fixed at level of upto 1.5m above ground level complete, after disconnecting the electrical connections and re-fixing the same in position after replacement of defective/ unserviceable spare parts/ accessories including connecting up and testing for satisfactory functioning, complete all as specified and as directed.
Cable XLPE insulated screened PVC bedded, galavanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor including taking out old underground cable of any size and any core including all fittings, complete all as speciifed and directed. Note : good conditioned bricks , PCC covers will be kept aside and duly stacked for reuse and will be measured under respective item of schedule for the following sizes of cable :-
6 sqmm 4 core.
16 sqmm 2 core.
10 Sqmm 4 core
10 Sqmm 2 core
Laying only bricks , PCC covers removed from srl item No 34 above for protection of UG cables all as directed .
GI pipe, 25mm bore, light grade, 1.50 metres long, bent to shape required, as in street light brackets, fixed to poles/ walls with suitable size MS clamps, nuts & bolts, complete all as specified and as directed.
GI pipe, 40mm bore, light grade, 1.50 metres long, bent to shape required, as in street light brackets, fixed to poles/ walls with suitable size MS clamps, nuts & bolts, complete all as specified and as directed.
Supply &fix driver for LED street light fittings 35 Watt, complete all as speciifed and directed.
Supply& fix driver for LED street light fittings 45 Watt, complete all as speciifed and directed.
Supply & fix driver for LED street light fittings 100 Watt, complete all as speciifed and directed.
Supply & fix driver for LED flood light fittings 200 Watt, complete all as speciifed and directed.
Supply & fix driver for LED flood light fittings 100 Watt, complete all as speciifed and directed.
Supply & fix driver for LED flood light fittings 60 Watt, complete all as speciifed and directed.
Opening the LED fittings of any wattage , taking out the LED motherbaord, checking the power LED's , replaceing the unserviceable power LED's and soldering and testing, complete all as specified and as directed.
Servicing of High mast of any height and description , opening the mechanical hoisting / lowering assy , steel wire bobbin , replaceing the unservieable meshing gear, easying the steel rope movements, checking the locking mechanism , replaceing of oil ,greasing complete and checking for smoothing operation of the mast, complete all as speciifed and as directed.
Dismantling the AC motor of High mast and taking out to workshop for re-winding , removing the burntout windings, re-winding the same with super enamelled copper wire of existing guage,varnishing and oven drying , assembling and testing in position, complete all as speciifed and directed.
S&Fsingle core PVC insulated FR cable with multistranded copper conductor of 1.5 sq.mm cross sectional area, 1100 Volts grade, fixed in repairs, complete all as speciifed and directed.
S&F single core PVC insulated FR cable with multistranded copper conductor of 2.5 sq.mm cross sectional area, 1100 Volts grade, fixed in repairs, complete all as speciifed and directed.
S&F PVC cable loop box, size not less than 145mm x 145mm x 95mm, out door type, duly fitted to poles with suitable clamp, nuts, bolts & washers including one No of 6 Amps single pole MCB, porcelain insulated connectors for incoming and outgoing cables including taking out unserviceable PVC box, complete all as speciifed and directed.
LT UG cable straight through joint (epoxy compounded) PVC insulated steel armoured type suitable with aluminium conductor cable for 25 to 50 Sqmm 4 core cable, complete all as speciifed and directed.
One coat of synthetic enamel painting (ZEBRA pattern with alternate yellow and black colour) to street light steel poles of 9m long up to a height of 1.5m from the coping of pole and one coat of aluminium painting for the remaining portion of pole including necessary preparation of surfaces, complete all as speciifed and directed.
One coat of synthetic enamel painting (ZEBRA pattern with alternate yellow and black colour) to street light steel poles of 11m long up to a height of 1.5m from the coping of pole and one coat of aluminium painting for the remaining portion of pole including necessary preparation of surfaces, complete all as speciifed and directed.
One coat of synthetic enamel painting (ZEBRA pattern with alternate yellow and black colour) to PSC street light poles of 9m long up to a height of 1.5m from the coping of pole and one coat distamper of existing shade for the remaining portion of pole including necessary preparation of surfaces, complete all as speciifed and directed.
S&F 3 pole power Contactors MO type 12 Amps AC3 rating with 1 No +1NC Aux contacts, fixed in repairs, complete all as specified and as directed. Make : L&T Cat No. CS94835or equivalent
S&F 3 pole power Contactors MO type 18 Amps AC3 rating with 1 NO +1NC Aux contacts, fixed in repairs, complete all as specified and as directed. Make : L&T Cat No. CS94834or equivalent
S&F Spare contact kit for MO12/MO18 type contactors including taking out unserviceable contact kit, complete all as speciifed and directed.
S&F Programmable digital time switches with battery backup and current capacity 16 Amps with 1 changeover including takingout the unserviceable time switch, complete all as speciifed and directed. Make Legrand Type Alpharex or equivalent.
S&F Street light panel box 32 Amps , 3 pole, 230volts with contactor, Digital 24 hours timer , MCB TPN etc., including taking down old timer box, complete all as speciifed and directed. Make Indo Asian TL032DBO or equivalent.
S&F LED flood light fitting 30 watts with pressure die cast housing with IP65 protection including taking down unserviceable fitting, complete all as speciifed and directed. Make Bajaj BJFL 60W LED or equivalentin philips / Wipro.
S&F LED flood light fitting 50 watts with pressure die cast housing with IP65 protection including taking down unserviceable fitting, complete all as speciifed and directed. Make Bajaj BJFL 60W LED or equivalentin philips / Wipro.
S&F LED flood light fitting 100 watts with pressure die cast housing with IP65 protection including taking down unserviceable fitting, complete all as speciifed and directed. Make Bajaj BJFL 60W LED or equivalentin philips / Wipro.
S&F Flood light fitting 200 watts with pressure die cast housing with IP65 protection including taking down unserviceable fitting, complete all as speciifed and directed. Make Bajaj BJFL 60W LED or equivalentin philips / Wipro.
S&F LED light fitting 30 watts with pressure die cast housing with IP65 protection including taking down unserviceable fitting, complete all as speciifed and directed. Make CG or equivalent .
S&F LED light fitting 60 watts with pressure die cast housing with IP65 protection including taking down unserviceable fitting, complete all as speciifed and directed. Make CG or equivalent .
S&F LED light fitting 45 watts with pressure die cast housing with IP65 protection including taking down unserviceable fitting, complete all as speciifed and directed. Make CG Cat No LFLE-30-CDL or equivalent .
S&F LED post-top light fitting 40 watts with body resistant to impact and corrosion with IP65 protection including taking down unserviceable fitting, complete all as speciifed and directed. Make CG or equivalent .
S&F LED post-top light fitting 20 watts with body resistant to impact and corrosion with IP65 protection including taking down unserviceable fitting, complete all as speciifed and directed. Make CG Cat No LPTO-40-CDL or equivalent .
S&F MCB SP 6A-32A 240V,10KA breaking capacity incl taking down unserviceable MCB, complete all as speciifed and directed.
S&F MCB TP 63A , 415V,10KA breaking capacity incl taking down unserviceable MCB, complete all as speciifed and directed.
Taking down solar CFL fitting 11 watts, testing & dismantling the fittings, supply and fix outdoor type LED solar street light fitting of 12 watts (dust to Dawn Charger controller) comprising of integrated driver, charge controller 12V /5A, operating voltage 12V, enclosed in aluminium die cast housing with IP 65 protection and testing, complete all as speciifed and directed.
S&F Solar MPPT / PWM charge controller 12V, 10 Amps, fixed as in repairs, complete all as speciifed and directed.
S&F 12V, 45Ah, tubular lead acid photovoltaic battery, fixed as in repairs, complete all as speciifed and directed.
S&F Battery box suitable for 45Ah SMF battery, fixed as in repairs, complete all as speciifed and directed.
S&F Solar PV panel 12 volts /70Wp, fixrd as in repairs, complete all as speciifed and directed.
Taking down carefully copper/aluminium point wiring (light fan socket or power) complete including fittings & fixtures such as switches, ceiling rose, pendants, regulators, sockets, ceiling roses,pendants, regulators, light fittings etc. Removing materials to store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified & as directed.
Point wiring complete with 1100volts grade, single core, PVC insulated FRLS cable multi-stranded copper conductor of size 1.5 sqmm nominal area, concealed type drawn through and including PVC Conduit of suitable size, with all necessary fittings and accessories fixed in walls/ ceiling with one run neutral and one run of single core cable of same description above but green colour in continous earthing wire connected to common earth dolly including PVC junction / mounting boxes on / in the wall / ceiling for piano switches/ switch socket combination/ fan regulators etc and GI junction box duly covered with 3mm thick hylam sheet for the following, complete all as specified and directed. :-
One light/ fan point controlled by one single pole 5 Amps switch
One switch socket out let point 5 Amps on independent board
One switch socket out let point 5 Amps on same board with other switches
One light point controlled by two 2-way switches, with cables 1.5 sq. mm size
One bell point controlled by one single pole 5 Amps bell push
All as per item No 3 here in before but for PVC insulated FRLS copper conductor of size 2.5 sqmm for switch socket multipurpose 15 Amps including provision of 1.5 Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board
All as per item No 3 here in before but for PVC insulated FRLS copper conductor of size 4.0 sqmm for switch socket multipurpose 15 Amps including provision of 2.5 Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board
Modular switch , 1 Module single pole one way 10 Amps, complete all as specified and directed.
Modular switch , 1 Module single pole one way 16 Amps, complete all as specified and directed.
Modular socket , 2 Module 6 Amps 240 volts Ac 2/3 pin combined suitable for inserting 2 pin 5 Amps/ 3 pin 5 Amps plug top, complete all as specified and directed.
Modular socket , 2 Module 6/16 Amps 240 volts Ac 6 pin combined suitable for inserting 3 pin 6/16 Amps plug top, complete all as specified and directed.
Modular type fan regulator 120W 2 Module type heavy duty, complete all as specified and directed.
PVC ceiling rose 65 x 50 mm surface type with 3 terminals, complete all as specified and directed.
Piano type switch single pole 5 Amps one way 230 volts, complete all as specified and directed.
Switch socket combination 2in 1, 3 pin 5 amps multi purpose flush type universal, with indicator, complete all as specified and directed.
Switch socket combination 5 in 1, 3 pin 5 and 16 amps multi purpose flush type universal, with indicator complete all as specified and directed.
socket combination 2in 1, 3 pin 5 amps flush type universal, complete all as specified and directed.
socket combination 2in 1, 3 pin 5 & 15 amps flush type universal, complete all as specified and directed.
Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade 1.50 sqmm in and including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 1.00 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade 2.50 sqmm in and including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 1.50 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade 4.00 sqmm in and including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 2.50 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade 6.00 sqmm in and including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 4.00 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
Modular Switch socket combination, 3 pin 5 amps flush type multi purpose, 3 module complete all as specified and directed.
Modular Switch socket combination 6 pin, 16 amps multi purpose, 3 module complete all as specified and directed.
Sheet metal enclosure for DB's double door SPN 8 ways when MCBs to be used single pole and neutral,deep drawn with 200 Amps rated copper bus bar 240V, complete all as specified and directed.
Sheet metal enclosure for DB's double door SPN 12 ways when MCBs to be used single pole and neutral,deep drawn with 200 Amps rated copper bus bar 240V, complete all as specified and directed.
Sheet metal enclosure for DB's double door TPN 6 ways when MCBs to be used single pole and neutral,deep drawn with 200 Amps rated copper bus bar 415 V, complete all as specified and directed.
Sheet metal enclosure for DB's double door TPN 8 ways when MCBs to be used single pole and neutral,deep drawn with 200 Amps rated copper bus bar 415 V, complete all as specified and directed.
MCB TPN, 63 Amps, 415 V, C- series with breaking capacity of 10KA, complete all as specified and directed.
MCB SPN, 40 Amps, 240 V, B- series with breaking capacity of 10KA, complete all as specified and directed.
MCB SP, 6-40 Amps, 240V, B- series with breaking capacity of 10KA, complete all as specified and directed. Cat Part No - 81108 to 811015 of make Indo Asian or equvalent of Havells/ Legrand/ C&S
Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with single pole MCB 20 Amps 240 Volts AC, complete all as specified and directed.
Bell push, flush type, 5 amp, complete all as specified and directed.
Buzzer, Ding Dong AC. 230 volts, single pole, complete all as specified and directed.
Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings
Taking down and connecting the electric meters from meter board and refixing the same including connecting up and provision of cable all as specified and directed.
Servicing/ overhauling of Electric energy meters of any size/ any capacity including testing of meters for running properly and accuracy including load testing with proper equipments
Supply & Fixing in repairs of Modular switch , 1 Module single pole one way 10 Amps, complete all as specified and directed.
Supply & Fixing in repairs of Modular switch , 1 Module single pole one way 16 Amps, complete all as specified and directed.
Supply & Fixing in repairs of Modular socket , 2 Module 6 Amps 240 volts Ac 2/3 pin combined suitable for inserting 2 pin 5 Amps/ 3 pin 5 Amps plug top, complete all as specified and directed.
Supply & Fixing in repairs of Modular socket , 2 Module 6/16 Amps 240 volts Ac 6 pin combined suitable for inserting 3 pin 6/16 Amps plug top, complete all as specified and directed.
Point wiring complete with 1100volts grade, single core, PVC insulated FRLS cable multi-stranded copper conductor of size 1.5 sqmm nominal area, drawn through and including PVC Casing Caping of suitable size, with all necessary fittings and accessories fixed in walls/ ceiling with one run neutral and one run of single core cable of same description above but green colour in continous earthing wire connected to common earth dolly including PVC junction / mounting boxes on / in the wall / ceiling for piano switches/ switch socket combination/ fan regulators etc and GI junction box duly covered with 3mm thick hylam sheet for the following, complete all as specified and directed. :-
One light/ fan point controlled by one single pole 5 Amps switch
One switch socket out let point 5 Amps on independent board
One switch socket out let point 5 Amps on same board with other switches
One bell point controlled by one single pole 5 Amps bell push
All as per item No 2 here in before but for PVC insulated FRLS copper conductor of size 2.5 sqmm for switch socket multipurpose 15 Amps including provision of 1.5 Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board
All as per item No 2 here in before but for PVC insulated FRLS copper conductor of size 4.0 sqmm for switch socket multipurpose 15 Amps including provision of 2.5 Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board
Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade 10.00 sqmm in and including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 6.00 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
ARUNOTHAYA TRADERS
Varsha Enterprises
RRK PROJECTS
Jagdamba Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .