| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in Soft/ Loose soil complete all as specified and as directed by Engineer-in- charge. | 270 | Cum | - | - |
| 2 | Excavating in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr and not exceeding 3.00mtr depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and exceeding 1.5 mtr and not exceeding 3.00mtr depth and getting out in Soft/ Loose soil complete all as specified and as directed by Engineer-in- charge. | 0.3 | Cum | - | - |
| 3 | Returning filling in, approved soft/loose soil, including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in any type of soil complete all as specified and as directed by Engineer-in- charge. | 172 | Cum | - | - |
| 4 | Removing excavated material/soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as spefied and as directed by Engineer-in-Charge. | 98 | Cum | - | - |
| 5 | Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed by Engineer-in-Charge.
(Note:- Punned thickness shall be considered for payment purpose) | 81 | Cum | - | - |
| 6 | Material and Labour Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the complete all as specified and directed by Engineer-in-Charge. | 8.69 | 1000 Per Nos | - | - |
| 7 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 35 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) | 1,000 | RM | - | - |
| 8 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) | 1,200 | RM | - | - |
| 9 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 70 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) | 250 | RM | - | - |
| 10 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 95 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) | 125 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.