Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹146.7 CrAccepted-AOC | ₹146.7 Cr | L-1 | Accepted-AOC L-1 Bidder |
| 2 | L-2₹149.3 CrRejected-Finance | ₹149.3 Cr | L-2 | Rejected-Finance L-2 Bidder |
Tender Value
₹135.8 Cr
EMD Value
₹2.7 Cr
Closing Date
27 Jan 2025, 4:00 pmClosed
SUPERINTENDING ENGINEER (Contract-II), RVPN,Jaipur
OFFICE OF THE SUPERINTENDING ENGINEER (Contract-II) NEW MM BUILDING OF RVPN, NEAR RAM MANDIR, BANI PARK, JAIPUR- 302006
Construction of 400KV GSS Hanumangarh along with Bay work at Rawatsar, Udyog Vihar and Sriganganagar under RVPN/KfW/NCB-3/BN-9019002415
2024_RRVPN_426159_1
RVPN/KfW/NCB-3/BN-9019002415
Open Tender
Electrical Works
720 days
Jaipur
Please refer Tender documents.
35 documents required · 35 mandatory
₹29,500
As per Bid Specification
₹2.7 Cr
Jaipur
11 Jul 2025
20 Dec 2024
27 Jan 2025
20 Dec 2024
27 Jan 2025
16 Jan 2025
3 Jan 2025
Amount
MAIN MATERIAL/ ITEMS
33/.433 kV, 800 kVA, LT three phase transformer
33/.433 kV, 800 kVA, LT three phase transformer complete with all fittings, accessories and associated equipment as per specification.
Spares
i) Bushing with metal parts & gaskets(HV&LV)
ii) Winding temperature indicator with contacts
iii) Oil temperature indicator with contacts
iv) Pressure relief device
v) Buchholz relay complete with contacts
vi) Magnetic oil level gauge
vii) Set of gaskets
33/.433 kV, 630 kVA, LT three phase transformer
33/.433 kV, 630 kVA, LT three phase transformer complete with all fittings, accessories and associated equipment as per specification.
Spares
i) Bushing with metal parts & gaskets(HV&LV)
ii) Winding temperature indicator with contacts
iii) Oil temperature indicator with contacts
iv) Pressure relief device
v) Buchholz relay complete with contacts
vi) Magnetic oil level gauge
vii) Set of gaskets
Circuit Breaker
420 kV, 3150 Amp., 50 kA rupturing capacity circuit Breaker suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
Terminal Connectors for above item
420 kV, 3150 Amp., 50 kA rupturing capacity circuit Breaker for controlling Shunt Reactor (Bus Type), suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
Terminal Connectors for above item
Microprocessor based point of wave controller for above item
Spares for 400 kV circuit breaker
(i) One pole of circuit breaker with grading capacitor complete with pole column and interrupter with M.B. but without support structure and operating mechanism.
(ii) Rubber gaskets, ‘O’ rings and seals
(iii) Fixed Contacts
(iv) Moving Contacts
(v) Terminal pads and connectors
(vii) Closing Assembly Valve
(viii) Trip Assembly Valve
(ix) Auxiliary Switch Assembly
(x) Operation Counter
(xi) Closing Coils
(xii) Tripping coils
(xiii) Support insulator complete for one pole of breaker
245 kV, 2000 Amp., 50 kA rupturing capacity circuit Breaker suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
Terminal Connectors for above item
Spares for 245 kV circuit breaker
(i) One pole of circuit breaker complete with pole column and interrupter with M.B. but without support structure and operating mechanism.
(ii) Rubber gaskets, ‘O’ rings and seals
(iii) Fixed Contacts
(iv) Moving Contacts
(v) Terminal pads and connectors
(vii) Closing Assembly Valve
(viii) Trip Assembly Valve
(ix) Auxiliary Switch Assembly
(x) Operation Counter
(xi) Closing Coils
(xii) Tripping coils
(xiii) Support insulator complete for one pole of breaker
Current Transformer
3000-2000-1000/1-1-1-1-1 Amp. 420 kV, 50 kA single phase multi core current transformers (Live Tank Type only)
Terminal Connectors for above item
Spare of 420kV Current Transformer
(i) Complete CT(Live Tank Type only)
(ii) Terminal Connector for above item 3.04
2000-1000-500/1-1-1-1-1 Amp. 50 kA, 245 kV single phase multi core current transformers (Live Tank Type only)
Terminal Connectors for above item
Spare of 245kV Current Transformer
(i) Complete CT(Live Tank Type only)
(ii) Terminal Connector for above item
Capacitive Voltage Transformer
420 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 400/0.11 kV and three secondary windings.
Terminal Connectors for above item
Spare of 420kV Capacitive Voltage Transformer
Spare of 420kV Capacitive Voltage Transformer
Terminal Connectors for above item
245 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 220/0.11 kV and three secondary windings.
Terminal Connectors for above item
Spare of 245kV Capacitive Voltage Transformer
(i) Complete CVT
(ii) Terminal Connector for above item
36kV, 52kV class EMVT
Terminal Connectors for above item
Isolator
420 kV 3150 Amp. triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
420 kV 3150 Amp. triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
Spares for 420 kV Isolators
i) One complete pole with support insulator and motor operating mechanism excluding structure
ii) Copper contact fingers for male and female contacts.
iii) Open / close contactor assembly, timers, key interlock push button switch
iv) Limit switch and auxiliary switch
v) Motor housing bearing assembly
vi) Terminal pads and connectors
vii) Motor with gear assembly and bevel gear assembly
viii) Bearings
ix) Current carrying assembly
x) Interlocking coil
245 kV 2000 Amp., 50 kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic without earth blade complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp., 50 kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp. , 50 kA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp., 50 kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic for tandem operation complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
Spares for 245 kV Isolators
i) One complete pole with support insulator and motor operating mechanism excluding structure
ii) Copper contact fingers for male and female contacts.
iii) Open / close contactor assembly, timers, key interlock push button switch
iv) Limit switch and auxiliary switch
v) Motor housing bearing assembly
vi) Terminal pads and connectors
vii) Motor with gear assembly and bevel gear assembly
viii) Bearings
ix) Current carrying assembly
x) Interlocking coil
72.5 kV , 800 Amp. , triple pole, gang operated, horizontal double break type Isolator without earth switch alongwith complete metallic and accessories.
Terminal Connectors for above item 5.45
Post insulators for above item 5.45
33 kV D.O. Fuse Set including terminal Connectors
Terminal Connectors for above item
Post insulators for above item
Surge Arresters
Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 390 kV lightning arresters suitable for connection between phase and ground on 3 phase 420 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
Terminal Connectors for above item
Spare of 390kV Surge Arresters
(i) Complete LA with insulating base
(ii) Terminal Connector for above item 6.04
Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 198 kV lightning arresters suitable for connection between phase and ground on 3 phase 245 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
Terminal Connectors for above item
Spare of 198kV Surge Arresters
(i) Complete LA with insulating base
(ii) Terminal Connector for above
42 kV, 52kV class Lightning arresters
Terminal Connectors for above
Wave Trap
400 kV, 1.0mH / 3150 A. Wave Traps Pedestal mounting type with tuning unit, protection device, terminals clamps, corona rings, bird barriers etc.
220 kV, 0.5 mH / 3150 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end.
CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
400kV Relay Panel for line with auto reclose scheme Type-SAS-FRC
400kV Relay Panel for 500MVA, 400/220kV Transformer Type-SAS-THRC
400kV Relay Panel for Tie Breaker with Auto Reclosure scheme and common Relay Panel Type SAS-BTRC
400kV Relay Panel for 125 MVAR Bus Reactor Type SAS-BSRB
400kV Relay Panel for 50 MVAR Line Reactor Type SAS-BSRB
220kV Relay Panel for feeder Type SAS-FRB
220kV Relay Panel for 500MVA, 400/220kV Transformer Type: SAS-TLRC
220kV Relay Panel for Transfer Bus Coupler Type: SAS-BCRB
220kV Relay Panel for 25 MVAR Bus Reactor Type: SAS-BSRB
220 kV relay panel for sectionalizer Type: SAS-BCRB
400kV Control Panel for line with auto reclose scheme Type-SAS-FCC
400kV Control Panel for 500MVA, 400/220kV Transformer Type: SAS-THCC
400kV control Panel for Tie Breaker with Auto Reclosure scheme and common Relay Panel Type SAS-BTCC
400kV Control Panel for 125 MVAR Bus Reactor Type SAS-BSRBB
400kV Control Panel for 50 MVAR Line Reactor Type SAS-BSRBB
220kV Control Panel for feeder Type SAS-FCB
220kV Control Panel for 500MVA, 400/220kV Transformer Type-SAS-TLCC
220kV Control Panel for Transfer Bus Coupler Type: SAS-BBCB
220 kV Control panel for 25 MVAR Bus Reactor Type: SAS-BSCB
220 kV Control panel for sectionalizer Type: SAS-BBCB
Bus Bar Protection Scheme having one no. central unit and 16 nos. peripheral units (PU) considering all existing and future dia of 400kV Switchyard designed for one & half breaker scheme (IEC-61850 Compliant).
Bus Bar Protection Scheme having one no. central unit and 22 nos. peripheral units (PU) considering all existing and future bays of 220kV Switchyard designed for double main and transfer bus scheme with sectionalizer (IEC-61850 Compliant).
GPS with Digital clock
Necessary software and hardware alongwith laptop to up / down load the data / from the relays from / to the laptop. The supply of laptop is covered under this scope.
Mandatory Spares for C&R panels (similar items as used in the quoted panels)
Line relay Panel:
· Main-I type relay
· Main-II Type Relay
· LBB Relay
· Auxiliary relay, Tripping Relay, Supervision relays, timers (one of each type used in the panel)
· Under-voltage relay for isolator/earth switch
· LBB Relay
Transformer Relay panel
· Main-I type Differential relay
· Main-II type Differential relay
· High impedance differential (Circulating current) Relay
· Over flux relay
· Transformer overload protection relay
· Restricted Earth fault relay
· Directional back up over current & E / F relay with non directional high set feature.
· Three phase trip relays, Flag relays, auxiliary relays, timers (One of each type used in the panel)
Shunt Reactor Relay panel
· Numerical differential protection Relay
· High impedance differential (Circulating current) Relay
· Restricted Earth fault relay
· Back up impedance relay
· Auxiliary, Tripping, supervision relays (One of each type used in the panel.
· Restricted Earth fault relay
Tie Breaker / Bus coupler / Sectionlizer / Transfer bus coupler.
· Auto Relcose Relay
· Non directional over current & earth fault relay.
400kV Bus bar Protection
· Peripheral unit (PU)
220kV Bus bar Protection
· Peripheral unit (PU)
SUBSTATION AUTOMATION SYSTEM
Complete substation automation system alongwith necessary spares for 5 years satisfactory operation as per scope of the specification.
Supply. erection, testing & commissioning of Ethernet Switch, OFC, BCU, IEDs etc. to complete the scope specification .
Phaser Measurement Unit
Phaser Measurement Unit along with fibre optic connectivity, Global Posioning System Receiver and communication Equipment.
PLCC EQIPMENTS
4 Channel, Digital PLCC Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
Digital Protection coupler microprocessor based suitable for Four commands.
VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
HF Armoured Coaxial cable having 125 Ohms unbalanced impendance.
PLCC Electronic Private Automatic Exchange (EPAX) suitable for 24 subscribers lines and 16 tie lines with redundancy of critical cards.
Telephone Sets (Push Button Type)
20 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.63 mm.
5 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.63 mm.
5 Pair jelly filled unarmoured telephone cable having copper conductor of Dia. 0.5 mm.
Copper cables 4x6 sq mm for PLCC (2 Run)
Sleeved copper wire of 8 SWG.
Any other item bidder may require to complete the PLCC system as per the specification requirement (if amount quoted, list of items , list of items alongwith quantity be indicated in technical offer)
Mandatory Spares
4 Channel, Digital PLCC Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
Digital Protection coupler microprocessor based suitable for Four commands.
VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
Cards for PLCC carrier terminal for each type
Coaxial cable
Set of electronic cards of each type
Coaxial connectors
Straight through joint
FOTE TERMINAL EQUIPMENTS
Fully wired cabinet with base 19” equipment rack (incl. front cover, cable tray, common cards) with fan unit and control, synchronization, Alarm, dual Power supply input cables
Central Processing Card – CPU
Power supply unit – 48 VDC 85 W
OLTE – 4 Port STM-1/4/16 Card along with SFPs U1.2, U4.2, U 16.2
Optical Amplifier / Booster equipment (comprising of wave length translator, Wavelength Converter, Booster Amplifier; 21 dBm, Pre Amplifier and Raman Amplifier + Software) for main as well as protected parts
OFC Patch Cords (Set of 48 nos.)
8 Port 2w/4w E&M interface Card
4 port Data Interface Card (Programmable)
4 Port Data interface Card (Programmable) for remote end (to be located at nearest SLDC / Sub-LDC)
Ethernet over SDH transport card (with four 10/100 base, one 100Base – FX and one 1000 Base-LX/SX front interfaces)
4 command integrated Tele-protection Card
MPLS TP Interface card
Engineering Order Wire Phone
Craft Terminal (LAPTOP PC) with element manager software
Interface Cable for Power, Data, Voice, Tele-protection, Time Synchronizing etc. as per respective site requirement
Approach Cable and necessary joint box for OPAW
Optical Fibre Distribution Panel (for 48 fibre) with spleing and patch parul
Optical Fibre Distribution Panel (for 96 fibre) with spleing and patch parul
HDPE Duct Pipe for OPGW
BATTERY AND BATTERY CHARGER
220 V, 600 AH Tubular Lead Acid Battery set along with accessories, stand etc.
220V, 100Amp/70Amp float cum boost Battery Charger (Separate sections for float and boost charging operation).
Spare for 220 V, 600 AH Tubular Lead Acid Battery set
i) Cells for 220 V bank
ii) Connectors
iii) Terminal lugs
iv) Spanner Set
Spare for 220 V battery charger
i) Set of control cards for charger
ii) Set of relays
iii) Rectifier transformer
iv) Control transformer
v) Series inductor
vi) Micro-Switches
vii) Filter Capacitor
viii) Thyristor diode
ix) Set of switches
x) Set of wound resistors
xi) Potentiometers
xiii) Fuses of thyristor with indicators
48 V, 600 AH VRLA Battery set along with accessories, stand and spares.
Spare for 48 V, 600 AH VRLA Battery set
i) Cells for 48 V bank
ii) Connectors
iii) Terminal lugs
50 V, SMPS battery charger of 100 Amp. DC Load capacity alongwith additional one No. 25 SMPS Module.
LT SWITCHGEAR
AC DISTRIBUTION BOARD
415 V, 1000 A, AC Main switch board
415 V, 400 A, AC Distribution Board
415 V, 400 A, Main lighting Distribution Board
415 V, 200 A, Emergency lighting Distribution Board
3 Phase, 415V, 800Amp. Changeover switch
415 V, Air conditioning distribution panel
SPARES
MCCB of each rating
MCB of each rating
LT Breaker
Spring Charging motor
Aux. contact set
Moving contacts set
Fixed contacts set
Spring closing / opening
Closing Coil
Tripping coil
Aux. finger contacts
Limit Switches
Breaker Trolley
Relays
CTs and PTs
DC DISTRIBUTION BOARD
220 V, 400 A, DC Distribution Board (for 2 DC Sources in two parts with bus coupler)
50 V, 200 A, DC Distribution Board (for 2 DC Sources in two parts with bus coupler)
Spares
MCCB of each rating
MCB of each rating
CT, PT (each type)
Voltmeter and Ammeter (each type)
Fuses (each type)
Indicating bulbs
Note:- ACDB & DCDB should be designed in such a manner so that each AC and DC feeder have duplicate connectivity.
DG SET
Diesel Generator set of stationary type having a net electrical out put of 160KVA capacity at specified site conditions with all its accessories for installation at 400 kV substation
Spare
i) Set of filters
ii) Solenoid coil assembly
iii) Self starter assembly
iv) Lub oil pressure safety control
v) High water temp. safety control
vi) AVR card for each type of DG set
HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
400 kV Double Tension String assembly with double anchoring points with 25 Nos. antifog type disc insulator per string with all hardware accessories including corona ring, turn buckle, arcing horn and tension clamp set suitable for Twin / quadruple Moose ACSR bundle with 450 mm sub-conductor spacing.(with/ without turn Buckle)
400 kV Single Suspension string insulator assembly with 25 Nos. anti fog type disc insulators with all hardware accessories including corona ring with dropper / through type clamp set for Twin / quadruple Moose ACSR with 450 mm sub-conductor spacing..(drop/through type)
245 kV double tension string assembly with single anchoring points with 15 Nos. anti fog type disc per string with all hardware accessories, including corona ring, turn buckle, arching horn and tension clamp set suitable for single / Twin Tarantulla bundle with 300mm sub conductor spacing.(with/ without turn Buckle)
245 kV single suspension string insulator assembly with 15 Nos. anti fog type disc insulators with all hardware accessories including corona ring, arching horn and suitable for through / drop clamp set for single / Twin Tarantulla bundle with 300mm sub conductor spacing..(drop/through type)
a) 400 kV Bus Post Insulator stacks with corona ring other than those not included with individual equipment.
b) 245 kV Bus Post Insulators other than those not included with individual equipment.
c) 72.5 kV Outdoor Post Insulators other than those not included with individual equipment.
400 kV Corona bellow / sphere for 4” IPS Al. tube
a) 400 kV clamps and connectors other than those not included with individual equipment.
b) 245 kV Clamps and Connectors other than those not included with individual equipment.
c) 72.5 kV Clamps & Connectors other than those not included with individual equipment.
d) All type clamp and connectors for earthwire and GS flat
a) 400 kV Spacers(All types Rigid/Flexiable )
a) 245 kV Spacers(All types Rigid/Flexiable )
Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
(a) 40 mm dia MS Rod
(b) 40 mm dia 3000 mm long MS rod (earth electrodes) with/without test links, RCC pits, C.I .cover hinged at C.I. frame alongwith all associated civil works
(c) 40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
a) 4” IPS (EH) Al. Tube (OD. 114.2 mm, Thickness-8.51 mm)
b) 3” IPS (EH) Al. Tube (OD. 73.03mm Thickness 7.01mm)
a) Welding sleeves for 4” IPS Al. tube
a) Welding sleeves for 3” IPS Al. tube
Earthwire tension clamps with D. Shackle assembly and earth bond
Lugs to suit 10.98 mm GS Earthwire
Junction boxes
Marshalling Kiosk
a) For 400 kV
b) For 220 kV
Cables (FRLS)
(a)1.1 KV grade PVC insulated armoured control cables – Cu
(b) 1.1 kV grade XLPE / PVC insulated armoured Al. conductor power cable
Straight through joints for 1.1 kV XLPE / PVC power cables as required
Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
Crimping type cable lugs (Tinned copper) of size of cable as required.
PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
Hume pipes for road crossing (NP-4 class). (Sizes shall be recommended by the bidder)
Pressure die cast AL (LM6) Nylon 6 made trefoil clamp for recommended cables
MS Angle Flat and ISMC channel (All size)
ACSR Moose conductor
AAC Tarantulla conductor
10.98mm dia GS earth wire
72.5 kV, 50 Amp. single phase horn gap fuse unit (Three phase)
Heat shrinkable tube / tape
52 KV XLPE Power Cable with all accessories
Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
IllUMINATION SYSTEM :
Switchyard Flood Lighting
Flood Light Luminaries
Energy Efficent flood light complete in all respect
Distribution pillars
Cable Trays
PVC Wires
Fibre Ladders (6/7 m)
Mobile Flood Light Tower
CONTROL ROOM BUILDING AND STREET LIGHTING
Lighting transformers (100 KVA)
Steel tubular poles with PVC wire JB , MCB, piller box complete cableling , panels etc complete in all respect
Elergy Efficent outdoor lights complete in all respect
Fiber Ladder (3 Mtr)
Any other items ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Spares
Energy Efficent flood light complete in all respect
Energy Efficent outdoor lights complete in all respect
Capacitors of each rating
MCCB each rating
MCB of each rating
Timer
FIRE FIGHTING SYSTEM ( AS PER TECHNICAL SPECIFICATION)
Mulsifyre System
Diesel Engine driven pump set of 410 M3/hr capacity 70 M Head
(a) Diesel engine pump complete with accessories
(b) Foot valve with strainer 300 mm
(c) Stop valve 250 mm
(d) CIDF suction pipe 300 mm
(e) Fittings
(f) Diesel Engine Controller with VRLA Maintenance free Battery, SMPS charger complete
Electric Motor driven pump set of 410 M3/hr capacity 70 M Head
(a) Pump & motor complete with starter
(b) Foot valve with strainer 300 mm
(c) Stop valve 250 mm
(d) CIDF suction pipe 300 mm
(e) Fittings
Air Vessel size 300 mm dia 1500 mm long
Set of interconnecting pipes, stop valves for interconnecting in pump house building
(a) 250 mm dia Gate valve
(b) 250 mm dia Steel pipe
Mulsifyre Strainer
Automatic starter, Diesel Engine starting panel
Compressor with driving motor
G.I. piping with fittings
(a) G.I. pipe 25 mm dia
(b) Fittings for 25 mm dia pipe
M.S. pipes suitable for overground and under ground as per relevant BIS
(a) 250 mm dia pipe.
(b) Fittings for 250 mm dia pipe
(c) 200 mm dia pipe.
(d) Fitting for 200 mm dia pipe
(e) 150 mm dia pipe.
(f) Fittings for 150 mm dia pipe
(g) 100 mm dia pipe.
(h) Fittings for 100 mm dia pipe.
Set of Deluge valve stop valves, supports projectors, detectors with pipe, alarm motor and gang for the mulsifyre protection of shunt reactors.
(a) Mulsifyre projectors
(b) Quartzoid bulb Detectors
(c) 150 mm dia Deluge valve
(d) 250 mm dia Drain valve
(e) 150 mm dia GI pipe
(f) 100 mm dia GI Pipe
(g) 80 mm dia GI Pipe
(h) 50 mm dia GI Pipe
(i) Alarm Motor & Gonge
(j) D.A. Switches
Alarm & 32 section Annunciation panel for complete installation
LT distribution Panel suitable for 3 ½ x 300 sq. mm. incoming & 6 Nos. 3 ½ x185 / 95 Sqmm for 3 Phase outgoing feeders of capacity meeting the requirement of each motor
Set of Deluge valve stop valves, supports projectors, detectors with pipe, alarm motor and gang for the mulsifyre protection of shunt reactors.
(a) Mulsifyre projectors
(b) Quartzoid bulb Detectors
(c) 150 mm dia Deluge valve
(d) 250 mm dia Drain valve
(e) 150 mm dia GI pipe
Power Cables & Control Cables
(a) 3 ½ x 300 Sqmm FRLS Cable
(b) 3 ½ x 185 Sqmm FRLS Cable
(c) 3 ½ x 95 Sqmm FRLS Cable
(d) 3x30 sq. mm. FRLS cable
(e) Control cable (Copper)
(f) Earthing
Note :- BOQ shown above is indicate only. It shall be finalized at the time of detail engineering as per the specification / requirement
Hydrant System
Electric Motor driven pump set of 410 M3/hr capacity 70 M Head
Electric pump motor & starter complete
Foot valve with strainer
Stop valve & size
CIDF suction pipe & size
Fittings
Pump & infeed piping with automatic priming arrangement
Air vessel of 300 mmdia 1.5 metre long
Set of pipes & valves
Check valve & size
Gate valve & size
Steel pipe 7 size
Elbow & size
Electric Control Panel including switchgear & wiring for manual and automatic start / stop of pumps
Ring main with pipes and fittings
150mm dia CITJ pipe / MS pipe
Fittings of 150mm dia pipe
100 mm dia CITJ pipe / MS pipe
Fittings of 100mm dia pipe
Hydrant Female Oblique type with stand pipe
Single headed stand pipe
Double Headed stand pipe
Gun metal landing valve
150mm dia Isolator valves
63mm dia 15M long hose pipe
Hose cabinets
Branch pipe & jets
Fog type Nozzle
Any other specified item for completion of Hydrant system ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Note :- BOQ shown above is indicate only. It shall be finalized at the time of detail engineering as per the specification / requirement
FIRE DETECTION AND ALARM SYSTEM
Micro-processor based Main fire detection control panel wired for suitable number of zones complete with control unit P.S. system, built in a battery and battery charger
Addressable Photo Electronic light scattered smoke detectors
Addressable Photo Electronic light scattered smoke detectors with duct caging
Addressable lonization chamber smoke detector
Linear Heat sensor cable
Heat Detector
Electronic Hooters
FRLS Control cables
2x1.5 sq.mm
10x1.5 sq.mm
NOTE :- Quantities of each item shall be finalized during approval of detailed engineering for respective substations. Capacity may vary as per IS.
HAND APPLIANCES
Pressurized, water type portable fire extingusher of 9 litre capacity complete with fill
Dry chemical powder type portable fire extingusher of 5 Kg. capacity complete with fill
Carbon di-oxide type portable fire extinguisher of 4.5 Kg. capacity complete with fill.
Fire Bucket with Stand
NOTE :- Quantities of each item shall be finalized during approval of detailed engineering for respective substations. Capacity of may vary as per IS.
SPARES FOR MULSIFYRE / HYDRANT SYSTEM
HVW – Pumps & Jockey pump
a)Shaft-Sleeve
b)Gland packing
Diesel Engine drive
a)Fuel oil filter
b)Lubricating oil filter
Nozzles (10% of total)
Quartzoil Detectors
Level Switch
Pressure Switch
Hydrant Valve
SPARES FOR FIRE ALARM
Smoke Detectors (10% of total)
Photo electric type (10% of total)
Ionization type (10% of total)
Heat Detectors (10% of total)
AIR-CONDITIONING AND VENTILATION SYSTEM WHICH SHALL INCLUDE FOLLOWING
Design, supply, installation, testing and commissioning of Air conditioning & ventilation system for the control room building for following rooms alongwith the necessary spares for satisfactory operation for 5 (five) years.
i) Control Room and OLTE / SAS Panel Room
ii SE / XEN Room
iii) Battery Room
iv) Rest Rooms etc.
Design, supply, installation, testing and commissioning of Air conditioning & ventilation system for all kiosks of bay level units in switchyard as per Section-II Vol-II (Air conditioning)alongwith the necessary spares for satisfactory operation for 5 (five) years.
STRUCTURES : Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
LATTICE STRUCTURE
Lignting Mast 24 m Height
Tower (400 kV) MKD TC
Tower (400 kV) MKD TH
Tower (400 kV) MKD TI
Tower (400 kV) MKD TJ
Tower (400 kV) MKD TM
Tower (400 kV) MKD TK
Tower (400 kV) MKD TG
Girder (400 kV) MKD G1
Girder (400 kV) MKD G2
220 kV tower type AT4
220 kV tower type AT8 (A6 With Peak)
220 kV tower type AT6 (Without Peak)
220 kV tower type AT1
220 kV Beam type AB1 / AB2
400 kV C.T. Support Structure
220 kV C.T. Support Structure
Pipe structures
400 kV CVT
220 kV CVT
400 kV Surge Arrestor
220 kV Surge Arrestor
400 kV Isolator
220 kV Isolator
400 kV Wave Trap
220kV Wave Trap
400 kV BPI
220 kV BPI
72.5 kV Isolator
42kV, 52 class Lightning arresters
36kV, 52 class EMVT (3 phase)
72.5 kV Horn gap fuse (3 phase)
72.5 kV Post insulators
Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification. (2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
TESTING AND MEASURING EQUIPMENTS
50 k-Ohms Earth Tester
Insulation Tester / Meggar (5 kV)
Digital Multi-meter
Digital Clamp Meter(Low range)
Analog Multi-meter
Universal Computerized Relay Test Kit alongwith Laptop (i7, 1.8 GHz, 14” TFT, 1 TB HDD, 8 GB Ram, DVD R/W) and associated configuration software
Dew Point Meter
Contact Resistance Meter
Microprocessor Based Transformer oil Resistivity & Tan Delta measurment kit
Three Phase Transformer Turn Ratio Tester Meter
SF6 Gas Leakage Detector
Circuit Breaker Analyzer
SF6 Gas filling and evacuation Kit
Portable Primary Injection Test kit
Microprocessor Based Dielectric Strength Analyzer
SFRA Test Kit
Digital Clamp Meter(High range)
CT Analyser
Multi function test kit
Portable Online DGA Analyser
Low Range Tong Tester
GENERAL TOOLS & TACKLES
Vacuum Cleaner
Ring Spanner Set
Tube Spanner Set
Pipe Wrench 24”
Pipe Wrench 18”
Heavy Duty Drilling Machine
Rechargable Torch
Insulated cutting plier 12”
Insulated cutting plier 8”
Line live tester
Screw Driver 18”
Screw Driver 12”
Hammer 8 lbs
Hammer 2 lbs
Allen keys
Box spanner Set
Screw Driver Set
Hydraulic Crimping Tool up tp 630 Sq mm.
OFFICE & MISCELLANEOUS EQUIPMENTS / ITEMS
Furniture for Control Room building
Junior executive table with three drovers on right side One Cup board left side with prelaminated decolam top 20mm thick over painted M.S. Frame ( 4 ½ feet x 2½ feet x 2½ feet) )
Control Desk Type Table for Control room accommodating the Main and Redundant Computer System monitors, Workstations, printer, Logger, Maintenance / Engineering Terminal, telephone etc.(Size, Shape, Colour etc. to be got approved from Owner)
Steel tubular chair “S” type with continuous and one feet dia 14 gauge pipe, cane seat backing, teak wood with quality cane.
Five Leg Revolving Chair with arms
Steel Almirah of size 6½ feetx3 feet x 19 inch with four shelves making five compartments in 18 guage with three way locking system
Steel Almirah (With Glass door) of size 6½ feetx3 feet x 19 inch with four shelves making five compartments in 18 guage with three way locking system
Minor Almirah of size 4½ feet x 30 inch x 17 inch with three shelves making four compartments in 18 guage with three waylocking system
Steel rack of size 5 feet x 3 feet x 16 inches with six shelves making five compartments (22 guage)
Steel stools of size 15 inch x 15 inch x 18 inch square pipe 16 guage
Short bench of 4 feet x 14 inch x 1 ½ inch with laminated top.
Steel waste paper baskets of size 12 inch x 10 inch x 10 inch
Canopy 6 x 6 x 7 Ft with stand
Camping Folding Chair Outdoor Garden,
Key board (wooden)
First Aid box
Shock Treatment Chart
REFRIGERATOR
Micro Wave
1800 W Induction Cooktop
Substation Glow sign board Size and Colour etc. to be got approved from owner)
Danger Plate (Size and colour etc. to be got approved from owner)
Insulated mat (SMC Chequered ) (5m x 1m x3mm)
Insulation Rubber Gloves (15 kV Tested)
SAFETY HELMETS
EARTHING ROD
Man Liffter (Hydraulic)
Polo Cart (Battery operated)
COMPUTER & Printer
Desktop Computer
Laser Printer
Filter Machine
Truck Mounted filter Machine (12 KL)
Spares for Filter Machine
Cratrage typr filter
Heater Element
Inlet Stainer
Solar panel system complete 100 KW
Solar panel system complete 100 KW with all necessary T&P. Cable, Meter, Structure etc.
Any Other item required for successful completion of work
Description of Work / Item(s)
Amount
MAIN MATERIAL/ ITEMS
145 kV, 1250 Amp. 40 kA rupturing capacity circuit breaker complete with mounting structures, foundation bolts, nuts and first filling of SF-6 gas plus 20% spare gas including accessories and auxiliaries
Terminal Connectors for above item
Current Transformer
500/1-1-1 Amp. 145 kV single phase multi core current transformers. (Live Tank Type only)
Terminal Connectors for above item
Capacitive Voltage Transformer
145 kV single phase 4400 pF CVT suitable for carrier coupling voltage ratio 132/0.11 Kv (3 Core)
Terminal Connectors for above item
Isolator
145 kV 1250 Amp. triple pole, gang operated Horizontal Double break type, outdoor, Isolator metallic without earth blade complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
145 kV 1250 Amp. triple pole, gang operated Horizontal Double break type, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
Surge Arresters
Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 120 kV lightning arresters suitable for connection between phase and ground on 3 phase 145 kV neutral grounded system complete with insulating base, surge counter and current meter, and all accessories as per specification.
Terminal Connectors for above item
Wave Trap
132 kV, 0.2 mH / 1000 A Wave traps with tuning unit protection device, terminals clamps and accessories etc. Including remote end,
CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
132 kV Feeder C&R Panel for feeder (J-II) 1A,110V DC
PLCC EQIPMENTS
4 Channel, Digital PLCC Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
Digital Protection coupler microprocessor based suitable for Four commands.
Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
Any other item bidder may require to complete the PLCC system as per the specification requirement (if amount quoted, list of items , list of items alongwith quantity be indicated in technical offer)
HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
Single Tension hardware for single Panther (Bolted type)
Single Suspension hardware for single Panther (Bolted type)
Disc Insulator 120 KN
Disc Insulator 70 KN
T CLAMP (Z to Z)
T CLAMP (Z to P)
T CLAMP (P to P)
PG CLAMP(Z to Z)
PG CLAMP(Z to P)
PG CLAMP(P to P)
PG Clamp for Earth Wire
Earth witr tension Assembaly
132 kV Outdoor Post Insulators other than those not included with individual equipment.
Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
M.S. Round 28 mm dia
M.S. Flat 50x10 mm
M.S. Channel 100x 50x6 mm
Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
Marshalling Kiosk
For 132 kV (200 Way Stud type)
Cables (FRLS)
18 core x 2.5 sq mm
12 core x 2.5 sq mm
4 core x 2.5 sq mm
4 core x 4 sq mm
Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
Crimping type cable lugs (Tinned copper) of size of cable as required.
PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
ACSR Zebra conductor
ACSR Panther conductor
GS earth wire
Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
IllUMINATION SYSTEM :
Switchyard Flood Lighting
Flood Light Luminaries
Energy Efficent flood light complete in all respect
Distribution pillars
STRUCTURES : Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
LATTICE STRUCTURE
132 KV P Type Structure
132 kv Q type Structure (Without stub)
132 kV R Type Structure
132 kV GDBeam
132kV C.T. Support Structure
132 kV CVT
132kV Surge Arrestor
132 kV Isolator
132 kV BPI
Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification. (2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
Any Other item required for successful completion of work
Description of Work / Item(s)
Amount
Service + ETC
145 kV, 1250 Amp. 40 kA rupturing capacity circuit breaker complete with mounting structures, foundation bolts, nuts and first filling of SF-6 gas plus 20% spare gas including accessories and auxiliaries
Terminal Connectors for above item
Current Transformer
500/1-1-1 Amp. 145 kV single phase multi core current transformers. (Live Tank Type only)
Terminal Connectors for above item
Capacitive Voltage Transformer
145 kV single phase 4400 pF CVT suitable for carrier coupling voltage ratio 132/0.11 Kv (3 Core)
Terminal Connectors for above item
Isolator
145 kV 1250 Amp. triple pole, gang operated Horizontal Double break type, outdoor, Isolator metallic without earth blade complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
145 kV 1250 Amp. triple pole, gang operated Horizontal Double break type, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
Surge Arresters
Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 120 kV lightning arresters suitable for connection between phase and ground on 3 phase 145 kV neutral grounded system complete with insulating base, surge counter and current meter, and all accessories as per specification.
Terminal Connectors for above item
Wave Trap
132 kV, 0.2 mH / 1000 A Wave traps with tuning unit protection device, terminals clamps and accessories etc. Including remote end,
CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
132 kV Feeder C&R Panel for feeder (J-II) 1A,110V DC
PLCC EQIPMENTS
SSB single Channel Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
A.F. Protection coupler microprocessor based suitable for Four commands.
Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
Any other item bidder may require to complete the PLCC system as per the specification requirement (if amount quoted, list of items , list of items alongwith quantity be indicated in technical offer)
HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
Single Tension hardware for single Panther (Bolted type)
Single Suspension hardware for single Panther (Bolted type)
Disc Insulator 120 KN
Disc Insulator 70 KN
T CLAMP (Z to Z)
T CLAMP (Z to P)
T CLAMP (P to P)
PG CLAMP(Z to Z)
PG CLAMP(Z to P)
PG CLAMP(P to P)
PG Clamp for Earth Wire
Earth witr tension Assembaly
132 kV Outdoor Post Insulators other than those not included with individual equipment.
Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
M.S. Round 28 mm dia
M.S. Flat 50x10 mm
M.S. Channel 100x 50x6 mm
Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
Marshalling Kiosk
For 132 kV (200 Way Stud type)
Cables (FRLS)
18 core x 2.5 sq mm
12 core x 2.5 sq mm
4 core x 2.5 sq mm
4 core x 4 sq mm
Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
Crimping type cable lugs (Tinned copper) of size of cable as required.
PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
ACSR Zebra conductor
ACSR Panther conductor
GS earth wire
Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
IllUMINATION SYSTEM :
Switchyard Flood Lighting
Flood Light Luminaries
Energy Efficent flood light complete in all respect
Distribution pillars
STRUCTURES : Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
LATTICE STRUCTURE
132 KV P Type Structure
132 kv Q type Structure (Without stub)
132 kV R Type Structure
132 kV GDBeam
132kV C.T. Support Structure
132 kV CVT
132kV Surge Arrestor
132 kV Isolator
132 kV BPI
Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification. (2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
ESHS Cost Schedule
Resources allocated to ESHS management
Drafting and updating the ESHS documentation, reporting, inspections
Implementation of the Health and Safety Plan: Meetings, health care centre, medical check ups, emergencies and evacuations, safety protective equipment, hygiene
Accommodation, drinking water, meals and transportation of staff(*) (*) : The Bidder shall detail the financial conditions of the supply of accommodation, meals and transport to its staff:
i) Accommodation
ii) Meals
iii) Transport
Training and local recruitment management costs
Protection of adjacent areas, biodiversity, prevention of erosion and wastewater management
Traffic, noise and atmospheric emissions management, land take
Waste and hazardous products management
Vegetation clearing and site rehabilitation
Any Other item required for successful completion of work
Description of Work / Item(s)
Amount
CIVIL WORKS
FOUNDATIONS :
LATTICE / PIPE STRUCTURE
132 KV P Type Structure
132kV C.T. Support Structure
132 kV CVT
132kV Surge Arrestor
132 kV Isolator
132 KV Circuir Breaker
132 kV BPI
Marshalling Kiosk
CABLE TRENCH
Section C
CABLE TRENCH CROSSING
Design, engineering, construction including supply of labour, material, cement, reinforcement steel, form work etc. and all associated works for construction of cable trench crossings as per technical specification and approved drawings
Section C crossing road
ANTI WEED TREATMENT AND BASE LAYER OF PCC
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
JELLY SPREADING (Gravelling)
Providing and laying 100mm thick layer of granite/basalt/trap jelly(gravel) of 40mm single size shall be spread over the entire switchyard area as per drawing and directions of engineer incharge of the work. The whole switchyard area (excluding buildings pathway road, drainages, cable trenches, equipments/ structures plinths etc.) shall be covered with jelly spreading. The jelly used shall be free from dirt, organic materials and flakes.
Supply & Fixing Barricades to confine Jelly (gravel), which include Supply and fixing cement concrete solid blocks of size 30x15x30 cms (l, b, h) jointed with CM 1:4, made from precast M-20 concrete and laid over 100 mm thick base of PCC 1:4:8 including necessary curing etc. complete. The top of concrete block shall be 100 mm above gravel top with provision of suatable openings for drainage of rain water. The exposed surface of barricades shall be applied with two coat of water proof cement paint.
Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete for 300 mm dia internal dia pipe including Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design and Excavating trenches of required width for pipes cables etc. including excavation for sockets, depth up to required depth including taking out the excavated materials, refilling the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, with all lead and lifts in all types of soil, rocks etc complete in all respect.
Any other specified work (If amount Quoted, list of items alongwith quantity be indicated in technical offer)
Description of Work / Item(s)
Amount
Services
500 MVA, 400/220/33 kV auto transformer
500 MVA, 400/220/33 kV, 3 phase, 50 Hz, Auto power transformer with oil for first filling and 10% spare quantity and complete with ON LOAD TAP CHANGER, , Atmoseal conservator,, RTCC panel, bushing CTs, one set of four Nos. Hydraulic jacks and all other fittings and accessories as per technical specification
400 KV, 125 MVAR Bus reactor
400 KV, 125 MVAR Bus reactor with oil for first filling and 10% spare oil complte in all respect as per specification
400 KV, 50 MVAR Line reactor
400 KV, 50 MVAR Line reactor with 145 kV NGR with oil for first filling and 10% spare oil complte in all respect as per specification as per specification
220KV, 25 MVAR Bus reactor with oil for first filling and 10% spare oil complte in all respect as per specification as per specification
NIFPES
Nitrogen Injection Fire Prevention system for 220KV, 25 MVAR Bus reactor as per specification as per specification
33/.433 kV, 800 kVA, LT three phase transformer
33/.433 kV, 800 kVA, LT three phase transformer complete with all fittings, accessories and associated equipment as per specification.
33/.433 kV, 630 kVA, LT three phase transformer
33/.433 kV, 630 kVA, LT three phase transformer complete with all fittings, accessories and associated equipment as per specification.
Circuit Breaker
420 kV, 3150 Amp., 50 kA rupturing capacity circuit Breaker suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
Terminal Connectors for above item
420 kV, 3150 Amp., 50 kA rupturing capacity circuit Breaker for controlling Shunt Reactor (Bus Type), suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
Terminal Connectors for above item
Microprocessor based point of wave controller for above item
245 kV, 2000 Amp., 50 kA rupturing capacity circuit Breaker suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
Terminal Connectors for above item
Current Transformer
3000-2000-1000/1-1-1-1-1 Amp. 420 kV 50 KA single phase multi core current transformers (Live Tank Type only)
Terminal Connectors for above item
2000-1000-500/1-1-1-1-1 Amp. 50 kA, 245 kV single phase multi core current transformers (Live Tank Type only)
Terminal Connectors for above item
Capacitive Voltage Transformer
420 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 400/0.11 kV and three secondary windings.
Terminal Connectors for above item
245 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 220/0.11 kV and three secondary windings.
Terminal Connectors for above item
36kV, 52kV class EMVT
Terminal Connectors for above item
Isolator
420 kV 3150 Amp. triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
420 kV 3150 Amp. triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp. triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic without earth blade complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp. triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp. triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp. triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic for tandem operation complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
72.5 kV , 800 Amp. , triple pole, gang operated, horizontal double break type Isolator without earth switch alongwith complete metallic and accessories.
Terminal Connectors for above item
Post insulators for above item
33 kV D.O. Fuse Set including terminal Connectors
Terminal Connectors for above item
Post insulators for above item
Surge Arresters
Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 390 kV lightning arresters suitable for connection between phase and ground on 3 phase 420 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
Terminal Connectors for above item
Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 198 kV lightning arresters suitable for connection between phase and ground on 3 phase 245 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
Terminal Connectors for above item
42 kV, 52kV class Lightning arresters
Terminal Connectors for above item
Wave Trap
400 kV, 1.0mH / 2000 A. Wave Traps Pedestal mounting type with tuning unit, protection device, terminals clamps, corona rings, bird barriers etc.
220 kV, 0.5 mH / 1250 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end.
CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
400kV Relay Panel for line with auto reclose scheme Type-SAS-FRC
400kV Relay Panel for 500MVA, 400/220kV Transformer Type-SAS-THRC
400kV Relay Panel for Tie Breaker with Auto Reclosure scheme and common Relay Panel Type SAS-BTRC
400kV Relay Panel for 125 MVAR Bus Reactor Type SAS-BSRB
400kV Relay Panel for 50 MVAR Line Reactor Type SAS-BSRB
220kV Relay Panel for feeder Type SAS-FRB
220kV Relay Panel for 500MVA, 400/220kV Transformer Type: SAS-TLRC
220kV Relay Panel for 25 MVAR Bus Reactor Type: SAS-BSRB
220kV Relay Panel for Transfer Bus Coupler Type: SAS-BCRB
220 kV relay panel for sectionalizer Type: SAS-BCRB
400kV Control Panel for line with auto reclose scheme Type-SAS-FCC
400kV Control Panel for 500MVA, 400/220kV Transformer Type: SAS-THCC
400kV control Panel for Tie Breaker with Auto Reclosure scheme and common Relay Panel Type SAS-BTCC
400kV Control Panel for 125 MVAR Bus Reactor Type SAS-BSRBB
400kV Control Panel for 50 MVAR Line Reactor Type SAS-BSRBB
220kV Control Panel for feeder Type SAS-FCB
220kV Control Panel for 500MVA, 400/220kV Transformer Type-SAS-TLCC
220kV Control Panel for Transfer Bus Coupler Type: SAS-BBCB
220 kV Control panel for 25 MVAR Bus Reactor Type: SAS-BSCB
220 kV Control panel for sectionalizer Type: SAS-BBCB
Bus Bar Protection Scheme having one no. central unit and 16 nos. peripheral units (PU) considering all existing and future dia of 400kV Switchyard designed for one & half breaker scheme (IEC-61850 Compliant).
Bus Bar Protection Scheme having one no. central unit and 22 nos. peripheral units (PU) considering all existing and future bays of 220kV Switchyard designed for double main and transfer bus scheme with sectionalizer (IEC-61850 Compliant).
GPS with Digital clock
Necessary software and hardware alongwith laptop to up / down load the data / from the relays from / to the laptop. The supply of laptop is covered under this scope.
SUBSTATION AUTOMATION SYSTEM
Complete substation automation system alongwith necessary spares for 5 years satisfactory operation as per scope of the specification.
Supply. erection, testing & commissioning of Ethernet Switch, OFC, BCU, IEDs etc. to complete the scope specification .
Phaser Measurement Unit
Phaser Measurement Unit along with fibre optic connectivity, Global Posioning System Receiver and communication Equipment.
PLCC EQIPMENTS
4 Channel, Digital PLCC Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
Digital Protection coupler microprocessor based suitable for Four commands.
VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
HF Armoured Coaxial cable having 125 Ohms unbalanced impendance.
PLCC Electronic Private Automatic Exchange (EPAX) suitable for 24 subscribers lines and 16 tie lines with redundancy of critical cards.
Telephone Sets (Push Button Type)
20 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.63 mm.
5 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.63 mm.
5 Pair jelly filled unarmoured telephone cable having copper conductor of Dia. 0.5 mm.
Copper cables 4x6 sq mm for PLCC (2 Run)
Sleeved copper wire of 8 SWG.
FOTE TERMINAL EQUIPMENTS
Fully wired cabinet with base 19” equipment rack (incl. front cover, cable tray, common cards) with fan unit and control, synchronization, Alarm, dual Power supply input cables
Central Processing Card – CPU
Power supply unit – 48 VDC 85 W
OLTE – 4 Port STM-1/4/16 Card along with SFPs U1.2, U4.2, U 16.2
Optical Amplifier / Booster equipment (comprising of wave length translator, Wavelength Converter, Booster Amplifier; 21 dBm, Pre Amplifier and Raman Amplifier + Software) for main as well as protected parts
OFC Patch Cords (Set of 48 nos.)
8 Port 2w/4w E&M interface Card
4 port Data Interface Card (Programmable)
4 Port Data interface Card (Programmable) for remote end (to be located at nearest SLDC / Sub-LDC)
Ethernet over SDH transport card (with four 10/100 base, one 100Base – FX and one 1000 Base-LX/SX front interfaces)
4 command integrated Tele-protection Card
MPLS TP Interface card
Engineering Order Wire Phone
Craft Terminal (LAPTOP PC) with element manager software
Interface Cable for Power, Data, Voice, Tele-protection, Time Synchronizing etc. as per respective site requirement
Approach Cable and necessary joint box for OPAW
Optical Fibre Distribution Panel (for 48 fibre) with spleing and patch parul
Optical Fibre Distribution Panel (for 96 fibre) with spleing and patch parul
HDPE Duct Pipe for OPGW
BATTERY AND BATTERY CHARGER
220 V, 600 AH Tubular Lead Acid Battery set along with accessories, stand etc.
220V, 100Amp/70Amp float cum boost Battery Charger (Separate sections for float and boost charging operation).
48 V, 600 AH VRLA (maintenance free) Battery set (23 Cells) along with accessories, stand and spares.
50 V, SMPS battery charger of 100 Amp. DC Load capacity alongwith additional one No. 25 Amp. SMPS Module.
LT SWITCHGEAR
415 V, 1000 A, AC Main switch board
415 V, 400 A, AC Distribution Board
415 V, 400 A, Main lighting Distribution Board
415 V, 200 A, Emergency lighting Distribution Board
3 Phase, 415V, 800Amp. Changeover switch
415 V, Air conditioning distribution panel
DC DISTRIBUTION BOARD
220 V, 400 A, DC Distribution Board (for 2 DC Sources in two parts with bus coupler)
50 V, 200 A, DC Distribution Board (for 2 DC Sources in two parts with bus coupler)
Note:- ACDB & DCDB should be designed in such a manner so that each AC and DC feeder have duplicate connectivity i.e. separate connection wiring to source -1 and source-2 (Refer drawings at Volume-II, ).
DG SET
Diesel Generator set of stationary type having a net electrical out put of 160KVA capacity at specified site conditions with all its accessories for installation at 400 kV substation
HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
400 kV Double Tension String assembly with double anchoring points with 25 Nos. antifog type disc insulator per string with all hardware accessories including corona ring, turn buckle, arcing horn and tension clamp set suitable for Twin / quadruple Moose ACSR bundle with 450 mm sub-conductor spacing. (WITH/WITHOUT TURN BUCKLE)
400 kV Single Suspension string insulator assembly with 25 Nos. anti fog type disc insulators with all hardware accessories including corona ring with dropper / through type clamp set for Twin / quadruple Moose ACSR with 450 mm sub-conductor spacing.(WITH/WITHOUT TURN BUCKLE)
245 kV single suspension string insulator assembly with 15 Nos. anti fog type disc insulators with all hardware accessories including corona ring, arching horn and suitable for through / drop clamp set for single / Twin Tarantulla bundle with 300mm sub conductor spacing.(Through/Drop type)
245 kV double tension string assembly with single anchoring points with 15 Nos. anti fog type disc per string with all hardware accessories, including corona ring, turn buckle, arching horn and tension clamp set suitable for single / Twin Tarantulla bundle with 300mm sub conductor spacing.(WITH/WITHOUT TURN BUCKLE)
a) 400 kV Bus Post Insulator stacks with corona ring other than those not included with individual equipment.
b) 245 kV Bus Post Insulators other than those not included with individual equipment.
c) 72.5 kV Outdoor Post Insulators other than those not included with individual equipment.
400 kV Corona bellow / sphere for 4” IPS Al. tube
a) 400 kV clamps and connectors other than those not included with individual equipment.
b) 245 kV Clamps and Connectors other than those not included with individual equipment.
c) 72.5 kV Clamps & Connectors other than those not included with individual equipment.
d) All type clamp and connectors for earthwire and GS flat
a) 400 kV Spacers(All types)(Rigid/ Flexiable)
a) 245 kV Spacers(All types)(Rigid/ Flexiable)
Earthwire tension clamps with D. Shackle assembly and earth bond
EARTHING MATERIAL
(a) 40 mm dia MS Rod
(b) 40 mm dia 3000 mm long MS rod (earth electrodes) with/without test links, RCC pits, C.I .cover hinged at C.I. frame alongwith all associated civil works
(c) 40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
IPS Tube
a) 4” IPS (EH) Al. Tube (OD. 114.2 mm, Thickness-8.51 mm)
b) 3” IPS (EH) Al. Tube (OD. 73.03mm Thickness 7.01mm)
a) Welding sleeves for 4” IPS Al. tube
b) Welding sleeves for 3” IPS Al. tube
Bay Marshalling kiosks
a) For 400 kV
b) For 220 kV
Cables (FRLS)
(a)1.1 KV grade PVC insulated armoured control cables – Cu
(b) 1.1 kV grade XLPE / PVC insulated armoured Al. conductor power cable
Straight through joints for 1.1 kV XLPE / PVC power cables as required
Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
Crimping type cable lugs (Tinned copper) of size of cable as required.
PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
Hume pipes for road crossing (NP-4 class). (Sizes shall be recommended by the bidder)
Pressure die cast AL (LM6) Nylon 6 made trefoil clamp for recommended cables
MS Angle Flat and ISMC channel (All size)
Conductor
ACSR Moose conductor
AAC Tarantulla conductor
10.98mm dia GS earth wire
72.5 kV, 50 Amp. single phase horn gap fuse unit (Three phase)
Heat shrinkable tube / tape
52 KV XLPE Power Cable with all accessories
Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
IllUMINATION SYSTEM :
Switchyard Flood Lighting
Flood Light Luminaries
Energy Efficent flood light complete in all respect
Distribution pillars
Cable Trays
PVC Wires
Mobile Flood Light Tower
CONTROL ROOM BUILDING AND STREET LIGHTING
Lighting transformers
Steel tubular poles with PVC wire JB , MCB, piller box complete cableling , panels etc complete in all respect
Elergy Efficent outdoor lights complete in all respect
Any other items ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
FIRE FIGHTING SYSTEM ( AS PER TECHNICAL SPECIFICATION)
Mulsifyre System
Diesel Engine driven pump set of 410 M3/hr capacity 70 M Head
(a) Diesel engine pump complete with accessories
(b) Foot valve with strainer 300 mm
(c) Stop valve 250 mm
(d) CIDF suction pipe 300 mm
(e) Fittings
(f) Diesel Engine Controller with VRLA Maintenance free Battery, SMPS charger complete
Electric Motor driven pump set of 410 M3/hr capacity 70 M Head
(a) Pump & motor complete with starter
(b) Foot valve with strainer 300 mm
(c) Stop valve 250 mm
(d) CIDF suction pipe 300 mm
(e) Fittings
Air Vessel size 300 mm dia 1500 mm long
Set of interconnecting pipes, stop valves for interconnecting in pump house building
(a) 250 mm dia Gate valve
(b) 250 mm dia Steel pipe
Mulsifyre Strainer
Automatic starter, Diesel Engine starting panel
Compressor with driving motor
G.I. piping with fittings
(a) G.I. pipe 25 mm dia
(b) Fittings for 25 mm dia pipe
M.S. pipes suitable for overgrond and under ground as per relevant BIS
(a) 250 mm dia pipe.
(b) Fittings for 250 mm dia pipe
(c) 200 mm dia pipe.
(d) Fitting for 200 mm dia pipe
(e) 150 mm dia pipe.
(f) Fittings for 150 mm dia pipe
(g) 100 mm dia pipe.
(h) Fittings for 100 mm dia pipe.
Set of Deluge valve stop valves, supports projectors, detectors with pipe, alarm motor and gang for the mulsifyre protection of shunt reactors.
(a) Mulsifyre projectors
(b) Quartzoid bulb Detectors
(c) 150 mm dia Deluge valve
(d) 250 mm dia Drain valve
(e) 150 mm dia GI pipe
(f) 100 mm dia GI Pipe
(g) 80 mm dia GI Pipe
(h) 50 mm dia GI Pipe
(i) Alarm Motor & Gonge
(j) D.A. Switches
Alarm & 32 section Annunciation panel for complete installation
LT distribution Panel suitable for 3 ½ x 300 sq. mm. incoming & 6 Nos. 3 ½ x185 / 95 Sqmm for 3 Phase outgoing feeders of capacity meeting the requirement of each motor
Set of Deluge valve stop valves, supports projectors, detectors with pipe, alarm motor and gang for the mulsifyre protection of shunt reactors.
Power Cables & Control Cables
(a) 3 ½ x 300 Sqmm FRLS Cable
(b) 3 ½ x 185 Sqmm FRLS Cable
(c) 3 ½ x 95 Sqmm FRLS Cable
(d) 3x30 sq. mm. FRLS cable
(e) Control cable (Copper)
(f) Earthing
Any other specified item for completion of Hydrant system ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Note :- BOQ shown above is indicate only. It shall be finalized at the time of detail engineering as per the specification / requirement
Hydrant System
Electric Motor driven pump set of 410 M3/hr capacity 70 M Head
Electric pump motor & starter complete
Foot valve with strainer
Stop valve & size
CIDF suction pipe & size
Fittings
Pump & infeed piping with automatic priming arrangement
Jockey pump & starter complete set
GI suction pipe & size
Air vessel of 300 mmdia 1.5 metre long
Set of pipes & valves
Check valve & size
Gate valve & size
Steel pipe 7 size
Elbow & size
Electric Control Panel including switchgear & wiring for manual and automatic start / stop of pumps
Ring main with pipes and fittings
150mm dia CITJ pipe / MS pipe
Fittings of 150mm dia pipe
100 mm dia CITJ pipe / MS pipe
Fittings of 100mm dia pipe
Hydrant Female Oblique type with stand pipe
Single headed stand pipe
Double Headed stand pipe
Gun metal landing valve
150mm dia Isolator valves
63mm dia 15M long hose pipe
Hose cabinets
Branch pipe & jets
Fog type Nozzle
Note :- BOQ shown above is indicate only. It shall be finalized at the time of detail engineering as per the specification / requirement
FIRE DETECTION AND ALARM SYSTEM
Micro-processor based Main fire detection control panel wired for suitable number of zones complete with control unit P.S. system, built in a battery and battery charger
Addressable Photo Electronic light scattered smoke detectors
Addressable Photo Electronic light scattered smoke detectors with duct caging
Addressable lonization chamber smoke detector
Linear Heat sensor cable
Heat Detector
Electronic Hooters
FRLS Control cables
2x1.5 sq.mm
10x1.5 sq.mm
NOTE :- Quantities of each item shall be finalized during approval of detailed engineering for respective substations.
AIR-CONDITIONING AND VENTILATION SYSTEM WHICH SHALL INCLUDE FOLLOWING
Design, supply, installation, testing and commissioning of Air conditioning & ventilation system for the control room building for following rooms alongwith the necessary spares for satisfactory operation for 5 (five) years.
i) Control Room and OLTE / SAS Panel Room
ii SE / XEN Room
iii) Battery Room
iv) Rest Rooms etc.
Design, supply, installation, testing and commissioning of Air conditioning & ventilation system for all kiosks of bay level units in switchyard as per clause No. 4.3 of Section-II Vol-II (Air conditioning)alongwith the necessary spares for satisfactory operation for 5 (five) years.
STRUCTURES : Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
LATTICE STRUCTURE
Lignting Mast 24 m Height
Tower (400 kV) MKD TC
Tower (400 kV) MKD TH
Tower (400 kV) MKD TI
Tower (400 kV) MKD TJ
Tower (400 kV) MKD TM
Tower (400 kV) MKD TK
Tower (400 kV) MKD TG
Girder (400 kV) MKD G1
Girder (400 kV) MKD G2
220 kV tower type AT4
220 kV tower type AT8 (A6 With Peak)
220 kV tower type AT6 (Without Peak)
220 kV tower type AT1
220 kV Beam type AB1 / AB2
400 kV C.T. Support Structure
220 kV C.T. Support Structure
Pipe structures
400 kV CVT
220 kV CVT
400 kV Surge Arrestor
220 kV Surge Arrestor
400 kV Isolator
220 kV Isolator
400 kV Wave Trap
220kV Wave Trap
400 kV BPI
220 kV BPI
72.5 kV Isolator
42kV, 52 class Lightning arresters
36kV, 52 class EMVT (3 phase)
72.5 kV Horn gap fuse (3 phase)
72.5 kV Post insulators
Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification. (2) Details of Tower structures & girders / beams available in Vol.II, Part-24 of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
Desktop Computer
Laser Printer
Filter Machine
Truck Mounted filter Machine (10 KL)
Solar panel system complete 100 KW
Solar panel system complete 100 KW with all necessary T&P. Cable, Meter, Structure etc.
ESHS Cost Schedule
Resources allocated to ESHS management
Drafting and updating the ESHS documentation, reporting, inspections
Implementation of the Health and Safety Plan: Meetings, health care centre, medical check ups, emergencies and evacuations, safety protective equipment, hygiene
Accommodation, drinking water, meals and transportation of staff(*) (*) : The Bidder shall detail the financial conditions of the supply of accommodation, meals and transport to its staff:
i) Accommodation
ii) Meals
iii) Transport
Training and local recruitment management costs
Protection of adjacent areas, biodiversity, prevention of erosion and wastewater management
Traffic, noise and atmospheric emissions management, land take
Waste and hazardous products management
Vegetation clearing and site rehabilitation
Filter Machine
Truck Mounted filter Machine (12 KL)
TRAINING CHARGES :- Training for substation automation system (For the courses as per scope of the specification).
Computer System Hardware
Computer System Software
Application Software
HANDHOLDING CHARGES
Lumpsum Charges for Handholding for 12 months from the date of Taking Over Certificate.
Any Other item required for successful completion of work
Description of Work / Item(s)
Amount
CIVIL WORKS
GEO TECHNICAL INVESTIGATION
Soil Investigation of substation / switchyard area as per technical specification.
FOUNDATIONS :
LATTICE / PIPE STRUCTURE
Lignting Mast 24 m Height
Tower (400 kV) MKD TC
Tower (400 kV) MKD TH
Tower (400 kV) MKD TI
Tower (400 kV) MKD TJ
Tower (400 kV) MKD TM
Tower (400 kV) MKD TK
Tower (400 kV) MKD TG
220 kV tower type AT4
220 kV tower type AT8 (A6 With Peak)
220 kV tower type AT6 (Without Peak)
220 kV tower type AT1
220 kV Beam type AB1 / AB2
400 kV C.T. Support Structure
220 kV C.T. Support Structure
220 kV C.T. Support Structure(metering)
400kV Circuit Breaker
220kV Circuit Breaker
Pipe structures
400 kV CVT
220 kV CVT
220 kV CVT(metering)
400 kV Surge Arrestor
220 kV Surge Arrestor
400 kV Isolator
220 kV Isolator
400 kV Wave Trap
220kV Wave Trap
400 kV BPI
220 kV BPI
72.5 kV Isolator
42kV, 52 class Lightning arresters
36kV, 52 class EMVT (3 phase)
72.5 kV Horn gap fuse (3 phase)
72.5 kV Post insulators
Marshalling Kiosk
Steel Tubular Poles
FOUNDATION FOR 500 MVA, 400/220/33 kV TRANSFORMER:-
FOUNDATION FOR 125 MVAR, 400 KV Bus Reactor:-
FOUNDATION FOR 50 MVAR, 400 KV Line Reactor:-
FOUNDATION FOR 25 MVAR, 220 KV Bus Reactor:-
Civil works for MS Tank including Excavation, Laying of 75 mm PCC, Constructing brick wall jacket around the tank, laying of 200 mm RCC raft, leveling and alignment of MS Tank, backfilling with excavated sand, Top leveling by laying of PCC, as per site requirement and Technical specifications (complete job). As per specification for 25 MVAR, 220 kV Bus Reactor
FOUNDATION FOR 33/0.415 kV, 800 kVA, LT three phase station transformer
FOUNDATION FOR 33/0.415 kV, 630 kVA, LT three phase station transformer
FOUNDATION / PLATEFORM FOR DG SET
CABLE TRENCH
Design, engineering and construction of R.C.C. cable trenches for required depths precast R.C.C. covers, water stops, brick works wherever required including the supply of labour, material, cement, reinforcement steel, steel angles, flats and providing P.C.C.(1:4:8) below cable trenches as per technical specification and approved drawings
Section B
Section C
Section D
Construction of RCC sump having capacity 10000 Liters with provision of automatic dewatering mud pump with disposal arrangement upto outside RVPN premises as directed by Engineeer In-charge with provision of a stand by pump.
CABLE TRENCH CROSSING
Design, engineering, construction including supply of labour, material, cement, reinforcement steel, form work etc. and all associated works for construction of cable trench crossings as per technical specification and approved drawings
Section B crossing road
Section C crossing road
TRENCHES for directly buried cables
ANTI WEED TREATMENT AND BASE LAYER OF PCC
Providing and supplying all labour material including borrowed / removal of earth for maintaining the FGL, equipments etc., soil sterilization / antiweed treatment including excavation, mixing / injecting chemicals to achieve the guaranteed effectiveness of treatment at least up to one year, rolling dressing, compacting the excavated earth within substation areas as per technical specification 100mm thick PCC (1:3:6) with 20 / 40mm graded aggregate as per technical specification.
Providing and supplying all labour, material including borrowed / removal of earth for maintaining the FGL, equipments etc., soil sterilization / antiweed treatment including excavation, mixing / injecting chemicals to achieve the guaranteed effectiveness of treatment at least up to one years, rolling dressing, compacting the excavated earth beyond the area of switchyard i.e. considered for future scope / work, laying of 150mm Crusher dust (residue of coarse aggregate) / Quarry Rubbish / Murram / any locally available Non cohesive material having anti weeding property as per technical specification.
JELLY SPREADING
a) After laying cement concrete (1:4:8) / brick edging in required slope / grade, 100mm thick layer of granite/basalt/trap jelly of 20mm size shall be spread over the entire switchyard area as per drawing and directions of engineer incharge of the work. The 20 mm nominal size shall pass 100% through IS. Sieve designation 40 mm and nothing through 16.00 mm IS Sieve. The whole switchyard area (excluding buildings pathway road, drainages, cable trenches, equipments/ structures plinths etc.) shall be covered with jelly spreading. The jelly used shall be free from dirt, organic materials and flakes.
b) Barricades shall be provided to confine Jelly Spreading which include construction of solid concrete block masonry in CM (1:6) with cement concrete solid blocks of proportion (1:5:3) crushing strength not less than 50 Kg. per Sq.cm / 40x40x20 cms. Size (l, b, h) conforming to IS 32185-196) including necessary curing etc. complete. The concrete block shall be 100 mm above gravel top. The exposed surface of barricades shall be plastered with 12 mm thick in CM (1:6) & two coat of water proof cement paint.
ROAD WORK
Design and construction of roads and walkways/shoulders within sub-station or outside the station as per specification, layout, sectional detail drawing and directions of Engineer-in-charge of work etc. complete in all respect.
a) 5.0 Mtr. Wide Road
a) 3.75 Mtr. Wide Road
STORM DRAINAGE SYSTEM
Design, construction if storm water drainage scheme including road, culverts, crossing of drains with cable trenches, sump pits etc. as per specification including outlet sump pit with provision of low head high discharge automatic pump.
FIRE WALL
Design, engineering, supply of labour, material including all associated works for construction of fire protection wall as per technical specification.
RAIN WATER HARVESTING
This is a lump sum item. The contractor shall be required to complete the work in all respect as per drawings furnished by the bidder and approved by the owner. All the items including excavation, miscellaneous steel, RCC, reinforcement , bore well, brick work, filling of boulders, gravel, sand, pipes etc. shall be deemed to be included in this lump sum rate.
CONTROL ROOM BUILDING
Construction of control room building as per drawing and specification including internal electricafication with Energy Efficient Light , Tube light fixtures etc, 15 lit storage geyser earthing, sanitary system including septic tank, soakage pit and rain water harvesting system as per drawing approved by owner/GWD etc., water supply system including making connection with distribution system, false ceiling (In Hall and PLCC room) fans,water cooler of cooling capacity 80 lit/hour and storage capacity of 120 lit, RO system withpurification capacity of 25 lit/hour and duty cycle of 170-250 lit/day with PVC tank of 200 lit capacity, internal cable trenches covered with 6 mm thick MS chequred plates, plinth protection works with chequred tiles etc.
BAY LEVEL KIOSK BUILDING (S) : Design & construction as per drawing and specification
400kV level
220kV level
FIRE FIGHTING PUMP HOUSE BUILDING
Design, Engineering and construction of fire fighting pump house including pump foundation, cable trench, water reservior etc.
WATER SUPPLY :-Supply and installation of water supply system with construction of GLR, subersible cable, fire fighting pump room including pump foundationn, required electrifcations cables from control room and panels, providing and laying GI pipe line from from GLR to control room, yard, guard room, for plantation etc including making connection , landscaping & plantation as per specification approved drawings and directions of engineer incharge
SEWERAGE SYSTEM :- Providing internal & external sewerage system for the control room building, septic tank etc. in the S/S as per Technical Specification
Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casing pipes as per IS:2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe : Work also includes Supplying and installation of submersible pumping motor pump sets I.S.I. Marked (IS : 8034-1989 ) and one stand bye pump of approved make like K.S.B., KIRLOSKAR, Calama etc. or equivalent, making connection suitable for T.W.. The job includes supplying and welding of flanges on G.I. riser pipes, pipe line of required dia up to GLR, Required cables from controm to panel and submersible pump, installation of complete fitting and accessories, with riser pipes, jointing of electrical cables and other connections making switch board electrical connections, panels etc as per disign and specifcation , all labour for testing of submersible pump set and supply of water to water mains, complete in all respect as diredted by engineer incharge. . Note: Tubewell shall be constructed as per fisibility report received from hydrogeologist/ collector
Providing and fixing cow catcher made of R.S. joist angles, channels MS round bars, MS flats etc including cutting welding and fabrication with priming coat of red oxide (as per design). The work includes construction of RR stone masonry wall of required section up to 90 cm below cow catcher, RCC bed plate of 20 cm thickness,cement plaster, PCC 1:4::8 in 15 cm thickness etc. complete as per approved design and specification. length of cow catcher should cover the entry gate and wicket gate with pillars
OTHER CIVIL WORKS
Security room
Vehicle parking shed (Four wheeler / two wheeler)
Store Shed with open platform
Retaining Wall for FG Level-1
Retaining Wall for FG Level-2(if required)
Any other specified work (If amount Quoted, list of items alongwith quantity be indicated in technical offer)
Description of Work / Item(s)
Amount
MAIN MATERIAL/ ITEMS
245 kV, 2000 Amp., 50 kA rupturing capacity circuit Breaker suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
Terminal Connectors for above item
Current Transformer
1000/1-1-1-1-1 Amp. 50 kA, 245 kV single phase multi core current transformers (Live Tank Type only)
Terminal Connectors for above item
Capacitive Voltage Transformer
245 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 220/0.11 kV and three secondary windings.
Terminal Connectors for above item
Isolator
245 kV 2000 Amp., 50 kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic without earth blade complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp., 50 kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp. , 50 kA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp., 50 kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic for tandem operation complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
Surge Arresters
Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 198 kV lightning arresters suitable for connection between phase and ground on 3 phase 245 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
Terminal Connectors for above item
Wave Trap
220 kV, 0.5 mH / 3150 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end.
CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
220 kV Control and relay Panel for Feeder
PLCC EQIPMENTS
4 Channel, Digital PLCC Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
Digital Protection coupler microprocessor based suitable for Four commands.
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
Any other item bidder may require to complete the PLCC system as per the specification requirement (if amount quoted, list of items , list of items alongwith quantity be indicated in technical offer)
FOTE TERMINAL EQUIPMENTS
Fully wired cabinet with base 19” equipment rack (incl. front cover, cable tray, common cards) with fan unit and control, synchronization, Alarm, dual Power supply input cables
Central Processing Card – CPU
Power supply unit – 48 VDC 85 W
OLTE – 4 Port STM-1 (155 Mbps Card) along with SFPs
Optical Amplifier / Booster equipment (comprising of wave length translator, Wavelength Converter, Booster Amplifier; 21 dBm, Pre Amplifier and Raman Amplifier + Software) for main as well as protected parts
OFC Patch Cords (Set of 48 nos.)
8 Port 2w/4w E&M interface Card
4 port Data Interface Card (Programmable)
4 Port Data interface Card (Programmable) for remote end (to be located at nearest SLDC / Sub-LDC)
Ethernet over SDH transport card (with four 10/100 base, one 100Base – FX and one 1000 Base-LX/SX front interfaces)
4 command integrated Tele-protection Card
Engineering Order Wire Phone
Optical Fibre Distribution Panel (for 48 fibre) with spleing and patch parul
HDPE Duct Pipe for OPGW
HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
Single Tension hardware for single Zebra (Bolted type)
Single Suspension hardware for single Zebra (Bolted type)
Disc Insulator 120 KN
Disc Insulator 70 KN
T-Clamps (Bolted Type) for Earth wire
PI Clamps for zebra
PG Clamps (Bolted Type) for Zebra to Zebra
T Clamps for Zebra to Zebra
PG Clamps for Earthwire
a) 245 kV Bus Post Insulators other than those not included with individual equipment.
Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
M.S. Round 28 mm dia
M.S. Flat 50x12 mm
M.S. Channel 100x 50x6 mm
Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
Marshalling Kiosk
b) For 220 kV
Cables (FRLS)
18 core x 2.5 sq mm
12 core x 2.5 sq mm
4 core x 2.5 sq mm
4 core x 4 sq mm
Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
Crimping type cable lugs (Tinned copper) of size of cable as required.
PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
ACSR Zebra conductor
GS earth wire
Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
IllUMINATION SYSTEM :
Switchyard Flood Lighting
Flood Light Luminaries
Energy Efficent flood light complete in all respect
Distribution pillars
STRUCTURES : Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
LATTICE STRUCTURE
22OKV.AT1 STRUCTURE
22OKV.AB1 BEAM
220 kV C.T. Support Structure
220 kV CVT
220 kV Surge Arrestor
220 kV Isolator
220 kV Isolator(tendum)
220kV Wave Trap
220 kV BPI
Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification. (2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
Any Other item required for successful completion of work
Description of Work / Item(s)
Amount
Service+ETC
245 kV, 2000 Amp., 50 kA rupturing capacity circuit Breaker suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
Terminal Connectors for above item
Current Transformer
1000/1-1-1-1-1 Amp. 50 kA, 245 kV single phase multi core current transformers (Live Tank Type only)
Terminal Connectors for above item
Capacitive Voltage Transformer
245 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 220/0.11 kV and three secondary windings.
Terminal Connectors for above item
Isolator
245 kV 2000 Amp., 50 kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic without earth blade complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp., 50 kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp. , 50 kA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
245 kV 2000 Amp., 50 kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic for tandem operation complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
Surge Arresters
Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 198 kV lightning arresters suitable for connection between phase and ground on 3 phase 245 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
Terminal Connectors for above item
Wave Trap
220 kV, 0.5 mH / 3150 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end.
CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
220 kV Control and relay Panel for Feeder
PLCC EQIPMENTS
4 Channel, Digital PLCC Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
Digital Protection coupler microprocessor based suitable for Four commands.
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
Any other item bidder may require to complete the PLCC system as per the specification requirement (if amount quoted, list of items , list of items alongwith quantity be indicated in technical offer)
FOTE TERMINAL EQUIPMENTS
Fully wired cabinet with base 19” equipment rack (incl. front cover, cable tray, common cards) with fan unit and control, synchronization, Alarm, dual Power supply input cables
Central Processing Card – CPU
Power supply unit – 48 VDC 85 W
OLTE – 4 Port STM-1 (155 Mbps Card) along with SFPs
Optical Amplifier / Booster equipment (comprising of wave length translator, Wavelength Converter, Booster Amplifier; 21 dBm, Pre Amplifier and Raman Amplifier + Software) for main as well as protected parts
OFC Patch Cords (Set of 48 nos.)
8 Port 2w/4w E&M interface Card
4 port Data Interface Card (Programmable)
4 Port Data interface Card (Programmable) for remote end (to be located at nearest SLDC / Sub-LDC)
Ethernet over SDH transport card (with four 10/100 base, one 100Base – FX and one 1000 Base-LX/SX front interfaces)
4 command integrated Tele-protection Card
Engineering Order Wire Phone
Optical Fibre Distribution Panel (for 48 fibre) with spleing and patch parul
HDPE Duct Pipe for OPGW
HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
Single Tension hardware for single Zebra (Bolted type)
Single Suspension hardware for single Zebra (Bolted type)
Disc Insulator 120 KN
Disc Insulator 70 KN
T-Clamps (Bolted Type) for Earth wire
PI Clamps for zebra
PG Clamps (Bolted Type) for Zebra to Zebra
T Clamps for Zebra to Zebra
PG Clamps for Earthwire
a) 245 kV Bus Post Insulators other than those not included with individual equipment.
Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
M.S. Round 28 mm dia
M.S. Flat 50x12 mm
M.S. Channel 100x 50x6 mm
Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
Marshalling Kiosk
b) For 220 kV
Cables (FRLS)
18 core x 2.5 sq mm
12 core x 2.5 sq mm
4 core x 2.5 sq mm
4 core x 4 sq mm
Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
Crimping type cable lugs (Tinned copper) of size of cable as required.
PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
ACSR Zebra conductor
GS earth wire
Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
IllUMINATION SYSTEM :
Switchyard Flood Lighting
Flood Light Luminaries
Energy Efficent flood light complete in all respect
Distribution pillars
STRUCTURES : Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
LATTICE STRUCTURE
22OKV.AT1 STRUCTURE
22OKV.AB1 BEAM
220 kV C.T. Support Structure
220 kV CVT
220 kV Surge Arrestor
220 kV Isolator
220 kV Isolator(tendum)
220kV Wave Trap
220 kV BPI
Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification. (2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
ESHS Cost Schedule
Resources allocated to ESHS management
Drafting and updating the ESHS documentation, reporting, inspections
Implementation of the Health and Safety Plan: Meetings, health care centre, medical check ups, emergencies and evacuations, safety protective equipment, hygiene
Accommodation, drinking water, meals and transportation of staff(*) (*) : The Bidder shall detail the financial conditions of the supply of accommodation, meals and transport to its staff:
i) Accommodation
ii) Meals
iii) Transport
Training and local recruitment management costs
Protection of adjacent areas, biodiversity, prevention of erosion and wastewater management
Traffic, noise and atmospheric emissions management, land take
Waste and hazardous products management
Vegetation clearing and site rehabilitation
Any Other item required for successful completion of work
Description of Work / Item(s)
Amount
CIVIL WORKS
FOUNDATIONS :
LATTICE / PIPE STRUCTURE
220 kV tower type AT1
220 kV C.T. Support Structure
220kV Circuit Breaker
220 kV CVT
220 kV Surge Arrestor
220 kV Isolator
220 kV Isolator (tendum)
220kV Wave Trap
220 kV BPI
Marshalling Kiosk
CABLE TRENCH
Section C
CABLE TRENCH CROSSING
Design, engineering, construction including supply of labour, material, cement, reinforcement steel, form work etc. and all associated works for construction of cable trench crossings as per technical specification and approved drawings
Section C crossing road
ANTI WEED TREATMENT AND BASE LAYER OF PCC
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
JELLY SPREADING (Gravelling)
Providing and laying 100mm thick layer of granite/basalt/trap jelly(gravel) of 40mm single size shall be spread over the entire switchyard area as per drawing and directions of engineer incharge of the work. The whole switchyard area (excluding buildings pathway road, drainages, cable trenches, equipments/ structures plinths etc.) shall be covered with jelly spreading. The jelly used shall be free from dirt, organic materials and flakes.
Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete for 300 mm dia internal dia pipe including Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design and Excavating trenches of required width for pipes cables etc. including excavation for sockets, depth up to required depth including taking out the excavated materials, refilling the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, with all lead and lifts in all types of soil, rocks etc complete in all respect.
Any other specified work (If amount Quoted, list of items alongwith quantity be indicated in technical offer)
Description of Work / Item(s)
Amount
MAIN MATERIAL/ ITEMS
145 kV, 1250 Amp. 40 kA rupturing capacity circuit breaker complete with mounting structures, foundation bolts, nuts and first filling of SF-6 gas plus 20% spare gas including accessories and auxiliaries
Terminal Connectors for above item
Current Transformer
500/1-1-1 Amp. 145 kV single phase multi core current transformers. (Live Tank Type only)
Terminal Connectors for above item
Capacitive Voltage Transformer
145 kV single phase 4400 pF CVT suitable for carrier coupling voltage ratio 132/0.11 Kv (3 Core)
Terminal Connectors for above item
Isolator
145 kV 1250 Amp. triple pole, gang operated Horizontal Double break type, outdoor, Isolator metallic without earth blade complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
145 kV 1250 Amp. triple pole, gang operated Horizontal Double break type, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
Surge Arresters
Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 120 kV lightning arresters suitable for connection between phase and ground on 3 phase 145 kV neutral grounded system complete with insulating base, surge counter and current meter, and all accessories as per specification.
Terminal Connectors for above item
Wave Trap
132 kV, 0.2 mH / 1000 A Wave traps with tuning unit protection device, terminals clamps and accessories etc. Including remote end,
CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
132 kV Feeder C&R Panel for feeder (J-II) 1A,110V DC
PLCC EQIPMENTS
4 Channel, Digital PLCC Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
Digital Protection coupler microprocessor based suitable for Four commands.
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
Any other item bidder may require to complete the PLCC system as per the specification requirement (if amount quoted, list of items , list of items alongwith quantity be indicated in technical offer)
FOTE TERMINAL EQUIPMENTS
Fully wired cabinet with base 19” equipment rack (incl. front cover, cable tray, common cards) with fan unit and control, synchronization, Alarm, dual Power supply input cables
Central Processing Card – CPU
Power supply unit – 48 VDC 85 W
OLTE – 4 Port STM-1 (155 Mbps Card) along with SFPs
OFC Patch Cords (Set of 48 nos.)
8 Port 2w/4w E&M interface Card
4 port Data Interface Card (Programmable)
4 Port Data interface Card (Programmable) for remote end (to be located at nearest SLDC / Sub-LDC)
Ethernet over SDH transport card (with four 10/100 base, one 100Base – FX and one 1000 Base-LX/SX front interfaces)
4 command integrated Tele-protection Card
Engineering Order Wire Phone
Optical Fibre Distribution Panel (for 48 fibre) with spleing and patch parul
HDPE Duct Pipe for OPGW
HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
Single Tension hardware for single Panther (Bolted type)
Single Suspension hardware for single Panther (Bolted type)
Disc Insulator 120 KN
Disc Insulator 70 KN
T CLAMP (Z to Z)
T CLAMP (Z to P)
T CLAMP (P to P)
PG CLAMP(Z to Z)
PG CLAMP(Z to P)
PG CLAMP(P to P)
132 kV Outdoor Post Insulators other than those not included with individual equipment.
Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
M.S. Round 28 mm dia
M.S. Flat 50x10 mm
M.S. Channel 100x 50x6 mm
Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
Marshalling Kiosk
For 132 kV (200 Way Stud type)
Cables (FRLS)
18 core x 2.5 sq mm
12 core x 2.5 sq mm
4 core x 2.5 sq mm
4 core x 4 sq mm
Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
Crimping type cable lugs (Tinned copper) of size of cable as required.
PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
ACSR Zebra conductor
ACSR Panther conductor
GS earth wire
Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
IllUMINATION SYSTEM :
Switchyard Flood Lighting
Flood Light Luminaries
Energy Efficent flood light complete in all respect
Distribution pillars
STRUCTURES : Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
LATTICE STRUCTURE
132kV C.T. Support Structure
132 kV CVT
132kV Surge Arrestor
132 kV Isolator
132 kV BPI
Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification. (2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
Any Other item required for successful completion of work
Description of Work / Item(s)
Amount
Service + ETC
145 kV, 1250 Amp. 40 kA rupturing capacity circuit breaker complete with mounting structures, foundation bolts, nuts and first filling of SF-6 gas plus 20% spare gas including accessories and auxiliaries
Terminal Connectors for above item
Current Transformer
500/1-1-1 Amp. 145 kV single phase multi core current transformers. (Live Tank Type only)
Terminal Connectors for above item
Capacitive Voltage Transformer
145 kV single phase 4400 pF CVT suitable for carrier coupling voltage ratio 132/0.11 Kv (3 Core)
Terminal Connectors for above item
Isolator
145 kV 1250 Amp. triple pole, gang operated Horizontal Double break type, outdoor, Isolator metallic without earth blade complete with all accessories.
Terminal Connectors for above item
Post insulators for above item
145 kV 1250 Amp. triple pole, gang operated Horizontal Double break type, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
Terminal Connectors for above item
Post insulators for above item
Surge Arresters
Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 120 kV lightning arresters suitable for connection between phase and ground on 3 phase 145 kV neutral grounded system complete with insulating base, surge counter and current meter, and all accessories as per specification.
Terminal Connectors for above item
Wave Trap
132 kV, 0.2 mH / 1000 A Wave traps with tuning unit protection device, terminals clamps and accessories etc. Including remote end,
CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
132 kV Feeder C&R Panel for feeder (J-II) 1A,110V DC
PLCC EQIPMENTS
4 Channel, Digital PLCC Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
Digital Protection coupler microprocessor based suitable for Four commands.
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
Any other item bidder may require to complete the PLCC system as per the specification requirement (if amount quoted, list of items , list of items alongwith quantity be indicated in technical offer)
FOTE TERMINAL EQUIPMENTS
Fully wired cabinet with base 19” equipment rack (incl. front cover, cable tray, common cards) with fan unit and control, synchronization, Alarm, dual Power supply input cables
Central Processing Card – CPU
Power supply unit – 48 VDC 85 W
OLTE – 4 Port STM-1 (155 Mbps Card) along with SFPs
OFC Patch Cords (Set of 48 nos.)
8 Port 2w/4w E&M interface Card
4 port Data Interface Card (Programmable)
4 Port Data interface Card (Programmable) for remote end (to be located at nearest SLDC / Sub-LDC)
Ethernet over SDH transport card (with four 10/100 base, one 100Base – FX and one 1000 Base-LX/SX front interfaces)
4 command integrated Tele-protection Card
Engineering Order Wire Phone
Optical Fibre Distribution Panel (for 48 fibre) with spleing and patch parul
HDPE Duct Pipe for OPGW
HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
Single Tension hardware for single Panther (Bolted type)
Single Suspension hardware for single Panther (Bolted type)
Disc Insulator 120 KN
Disc Insulator 70 KN
T CLAMP (Z to Z)
T CLAMP (Z to P)
T CLAMP (P to P)
PG CLAMP(Z to Z)
PG CLAMP(Z to P)
PG CLAMP(P to P)
132 kV Outdoor Post Insulators other than those not included with individual equipment.
Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
M.S. Round 28 mm dia
M.S. Flat 50x10 mm
M.S. Channel 100x 50x6 mm
Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
Marshalling Kiosk
For 132 kV (200 Way Stud type)
Cables (FRLS)
18 core x 2.5 sq mm
12 core x 2.5 sq mm
4 core x 2.5 sq mm
4 core x 4 sq mm
Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
Crimping type cable lugs (Tinned copper) of size of cable as required.
PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
ACSR Zebra conductor
ACSR Panther conductor
GS earth wire
Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
IllUMINATION SYSTEM :
Switchyard Flood Lighting
Flood Light Luminaries
Energy Efficent flood light complete in all respect
Distribution pillars
STRUCTURES : Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
LATTICE STRUCTURE
132kV C.T. Support Structure
132 kV CVT
132kV Surge Arrestor
132 kV Isolator
132 kV BPI
Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification. (2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
ESHS Cost Schedule
Resources allocated to ESHS management
Drafting and updating the ESHS documentation, reporting, inspections
Implementation of the Health and Safety Plan: Meetings, health care centre, medical check ups, emergencies and evacuations, safety protective equipment, hygiene
Accommodation, drinking water, meals and transportation of staff(*) (*) : The Bidder shall detail the financial conditions of the supply of accommodation, meals and transport to its staff:
i) Accommodation
ii) Meals
iii) Transport
Training and local recruitment management costs
Protection of adjacent areas, biodiversity, prevention of erosion and wastewater management
Traffic, noise and atmospheric emissions management, land take
Waste and hazardous products management
Vegetation clearing and site rehabilitation
Any Other item required for successful completion of work
Description of Work / Item(s)
Amount
CIVIL WORKS
FOUNDATIONS :
LATTICE / PIPE STRUCTURE
132kV C.T. Support Structure
132 kV CVT
132kV Surge Arrestor
132 kV Isolator
132 kV BPI
132 kV Circuit Breaker
Marshalling Kiosk
CABLE TRENCH
Section C
CABLE TRENCH CROSSING
Design, engineering, construction including supply of labour, material, cement, reinforcement steel, form work etc. and all associated works for construction of cable trench crossings as per technical specification and approved drawings
Section C crossing road
ANTI WEED TREATMENT AND BASE LAYER OF PCC
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
JELLY SPREADING (Gravelling)
Providing and laying 100mm thick layer of granite/basalt/trap jelly(gravel) of 40mm single size shall be spread over the entire switchyard area as per drawing and directions of engineer incharge of the work. The whole switchyard area (excluding buildings pathway road, drainages, cable trenches, equipments/ structures plinths etc.) shall be covered with jelly spreading. The jelly used shall be free from dirt, organic materials and flakes.
Supply & Fixing Barricades to confine Jelly (gravel), which include Supply and fixing cement concrete solid blocks of size 30x15x30 cms (l, b, h) jointed with CM 1:4, made from precast M-20 concrete and laid over 100 mm thick base of PCC 1:4:8 including necessary curing etc. complete. The top of concrete block shall be 100 mm above gravel top with provision of suatable openings for drainage of rain water. The exposed surface of barricades shall be applied with two coat of water proof cement paint.
Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete for 300 mm dia internal dia pipe including Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design and Excavating trenches of required width for pipes cables etc. including excavation for sockets, depth up to required depth including taking out the excavated materials, refilling the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, with all lead and lifts in all types of soil, rocks etc complete in all respect.
Any other specified work (If amount Quoted, list of items alongwith quantity be indicated in technical offer)
Kanohar Electricals Limited (BID ID -3053919)
Kanohar Electricals Limited (BID ID -3053919)
AMARA RAJA INFRA PRIVATE LIMITED (BID ID -3054323)
Kanohar Electricals Limited (BID ID -3053919)
AMARA RAJA INFRA PRIVATE LIMITED (BID ID -3054323)
AMARA RAJA INFRA PRIVATE LIMITED (BID ID -3054323)
Kanohar Electricals Limited (BID ID -3053919)
AMARA RAJA INFRA PRIVATE LIMITED (BID ID -3054323)
AMARA RAJA INFRA PRIVATE LIMITED (BID ID -3054323)
Kanohar Electricals Limited (BID ID -3053919)
Kanohar Electricals Limited (BID ID -3053919)
Kanohar Electricals Limited (BID ID -3053919)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid