MANAGING DIRECTOR
Head Office, Koyambedu, Chennai-107
Improvements to the existing godown roofing by replacing the A.C Sheet roofing with Galvalume sheet in TNCSC godown campus at Naickanoor Village in Vaniyampadi Taluk in Thirupathur District.
2026_TCSC_699146_1
6/CED6/ 020738 /2026
Open Tender
Civil Works
Lump-sum
90 days
VANIYAMBADI
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹17,100
28 Aug 2026
28 Aug 2026
11 Sept 2026
28 Aug 2026
11 Sept 2026
28 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Dismantling and removing AC sheet roofing without roof timbers and clearing away and carefully stacking materials useful for re-use and as directed by the departmental officers. | - | M2 | - | - |
| 1.02 | Dismantling Brick / stone masonry in cement mortar walls under 3m height for any thickness of wall and clearing away and carefully stacking materials useful for re-use as directed by the departmental officers. | - | M3 | - | - |
| 1.03 | Supplying and laying of High profile colour galvalume sheet (as per ISI Standard) with combination 55A1:43 4Zn:1:6SI of TCT bent type 0.47mm thick not less than 150 GSM and standard width of 1.06m with yield strength of 550 MPA made from high tensile/ CR sheets of approved quality for roofing with necessary fixing arrangements like 65m and long hexagonal head screws with EPDM rubber seal etc., complete, complying with standard specification and as directed by the departmental officer. (Test certificate for quality should be furnished on receipt of material at site) | - | M2 | - | - |
| 1.04 | BRICK WORK in cement mortor 1:6(one cement, six sand) using best quality Country bricks of size 8” ¾”x4 ¼ x 2 ¾ “ for walls including cost of scaffolding curing, finishing etc., complete complying with standard specification and as directed by the departmental officers.
In foundation and basement. | - | M3 | - | - |
| 1.05 | PLASTERING with cement mortor 1:5 (one cement and five sand) 12mm thick including mortar plasticizer at 200ML per 50kg of cement used cost of scaffolding, finishing, curing etc., complete complying with standard specification and as directed by the departmental officers. | - | M2 | - | - |
| 1.06 | Providing FORM WORK for centering the soffits of all reinforcement concrete work including strutting to the required (3 metre) height with mild steel sheets of size 90cm x60cm 10gauge stiffened with welded mild steel angles of size 25mm x 25mm x 3mm laid with country wood joist of average of size 10cm x 6.50cm at about 90cm centers with casuarinas props of 13cm dia at 75cm centre to centre with all nails coir, wedges complete and removing the form work after necessary curing period as directed by the corporation officers. The rates should inclusive of cutting, bending, welding charges of M.S.sheets; M.S. angles etc complete complying with standard specification and as directed.
Binder wall. | - | M2 | - | - |
| 1.07 | Providing and laying in position, Standardised Concrete Mix M20 Grade in accordance with IS:456-200 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/M3 and mazimum water cement ratio of 0.55, including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improvement workability without impairing strength and durability with about (5 Cu.m) 7730 Kg of 20mm machine crushed stone jelly and with about (3.3 Cum)5156 kg of 0-12mm machine crushed stone jelly and with about (4.7 Cum) 7670 kg of sand, but excluding cost of reinforcement gril and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, cutting etc., and Providing fixtures like fan clams in the RCC floor/ roof slabs wherever necessary without claiming extra etc., complete complying with standard specification and as directed the departmental officers. The coarse and five aggregates to be used should comply with the requirements of 15 Standards. (No separate payment will be made by the Department for the excess usage of materials. | - | M3 | - | - |
| 1.08 | Supplying, fabricating and placing in position MS/RTS grills for reinforcement for all R.C.C.works including cost of steel, labour for straightening, bending, cranking, tying grills with 18 gauge galvanized binding wire and placing grills in position complete complying with standard specification and as directed. | - | QTL | - | - |
| 1.09 | Supplying and laying of High profile colour galvalume sheet ridges (as per ISI Standard) 55A1:43 4Zn:1:6SI of TCT bent type 0.47 mm thick not less than 150 GSM and standard width of 1.06m with yield strength of 550 MPA made from high tensile/ CR sheets of approved quality for roofing with necessary fixing arrangements like 65m abd long hexagonal head screws with EPDM rubber seal etc., complete, complying with standard specification and as directed by the departmental officer. (Test certificate for quality should be furnished on receipt of material at site) | - | RM | - | - |
| 1.1 | Supplying and fixing corrugated Poly Carbonate sheet of size 3mx1.06m of 3mm thick on the roof in-between the colour coated Galvalume sheets for proper lighting with necessary G.I screws and EPDM rubber washers, including cost of loading, unloading and transportion charges etc., Complying with standard specification and as directed by the departmental officers. | - | M2 | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
BOQ_840490.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .