| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹10.6 LAccepted-AOC | 1st | Accepted-AOC Lower Rate | |
| 2 | 2nd₹11.1 L+₹50,547.62 (4.76%)Rejected-Finance MANSA | BATHINDA | PUNJAB | 151302 | 2nd | Rejected-Finance Higher Rate |
Tender Value
Refer Docs
EMD Value
₹22,815
Closing Date
15 Jun 2020, 5:00 pmClosed
Executive Engineer
EXECUTIVE ENGINEER WATER SUPPLY AND SANITATION DIVISION NO 1 MANSA VILLAGE JAWAHRKE
Improvement of Rural water suplly scheme for village Behniwal in Block Jhunir Distt Mansa Repair of S AND S Tank Pump Chamber OHSR Filter beds and Replacement of Filter media of Filter beds Making water connection to house hold Repair
2020_WB_48355_1
MANSA-DIV-1/2020-21/001
Open Tender
Civil Works
Item Rate
90 days
Mansa
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
TIA
₹22,815
2 Sept 2020
5 Jun 2020
16 Jun 2020
5 Jun 2020
15 Jun 2020
5 Jun 2020
Amount
Carriage of Surkhi, Sand, Bajri, Ballast, Stone, Boulders, Kankar,and Building Rubbish
Filter media Lead 320 KM
Up to 40 km
41 km to 60 km
61 km to 150 km
151 km to 320 km
Scraping
Cement Plaster
Cement Concrete floor 40mm thick 1:2:4 with stone ballast.using concrete mixer volumetric type.
Conglomerate floor 50mm thick cement concrete rate 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand filling.
12.5 mm thick cement plaster 1:2
20mm thick cement plaster 1:4 in two coats work
Cement rendering on plaster 1mm thick
White washing (Three coat)
Hollock wood, doors, shutter, windows, shutter including hinges, screws, chocks, cheats, stops, cords etc. complete fixed in position )
Panelled,glazed or glazed and panelled(Double Leaf)
35 mm thick
Steel work fixed independently without connection plates,including cutting hoisting and fixing in position
Tees,angels and channels
Providing & fixing C.I./DI flanged end.,stem of ss(AIS 1410)and Bronze(Gun Metal ) working part sluice valve ISI marked 14846 -2000 .including jointing testing and cost of Nut Bolt and insertion sheet ,all carriage complete(with the approval of engineer- in-charge)
Class PN-1 as per ISI
Providing and placing in horizontal layers filtering media screaned washed and cleaned as described below
Top Layer :- Fine sand screaned cleened and washed and graded (effective size 0.2 to 0.4 mm with uni formity coefficient 2.00 to 3.00) from pathankot or other approved source
Providing & fixing 560mm, 500mm and 450mm internal Diametre circular or 455 mm x 610mm clear inside opening rectangular cast iron manhole cover and frame ISI marked as per IS12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines and levels in 1:2 cement sand mortar over manholes including cement concrete copping (1:2:4)around the frame etc.Dia of steel for lifting hook is 16mm.
560mm i/d Medium duty
Supplying and fixing 200 mm i/d Galvanized iron sheet floating arm 5.20 mtr long including sluice valve, survivel bend, floating drum, extended rod with hand wheel brackets and guides complete in all respects as per Public Health standard.
Supplying and fixing steel ladder for outside DOM Complete in all respect
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.
Labour for making 3 nos holes and one no cut incase of angle iron pickets
Providing and fixing barbed wire fencing 3 ply rating with angle iron picts with MS clips including labour for stretching of barbed wire and cost of clips
Providing fixing control pannel (7.5 BHP)including switch/MCB 16 Amp.TP, L&T Make pole contactor,Trlay 6-10 Amp,LED indicator, Volt Meter ,AMP Meter Shunt Capastor,Pannel Accessories Labor of fitting panel BOX complete in all respects
Providing fixing control pannel (17.5 BHP) including switch/MCB 16 Amp.TP, L&T Make pole contactor,Trlay 6-10 Amp,LED indicator, Volt Meter ,AMP Meter Shunt Capastor,Pannel Accessories Labor of fitting panel BOX complete in all respects
Taking out and washing filter media and placing the same after washing, cleaning in filter beds
Second Layer
Third Layer
Fourth Layer
Fifth Layer
Providing house hold connection incuding laying, jointing, fixing testing below ground level MDPE pipe and above of ground level GI pipes (as approved by Engineer-In-Charge), including cost of excavation, Refilling, CI bib cock as per IS:210 with stainless steel, spindle, 15mm i/d GI pipe 2.50 Mtr. and 15 mm i/d MDPE pipe 2 meter (length on average basis) 3" i/d UPVC clamp, ISI marked G.M. ferruleas per IS:2692 connection of 15mm I/D ferrule medium, specials such as tees, bends, sockets, elbow, nipples (100 mm % 150mm) Union Copplings, GI hooks etc.cutting threading making hole in wall and testing in treanches in the ground all material should be of approved make (to the approval of Engineer-in-charge) complete in all respect including cost of carriage. (Ref. CSR item Nos. 28.1,28.36,28.34 B,30.65 B)
on old pipe line
Repair of existing House Hold connection Providing and laying, jointing, fixing, testing GI Pipe lines including cost of Specials such as tees, bends, sockets, elbow etc. cutting, threading and testing in trenches, ISI Marked G.M. ferrule 15 mm i/d as per IS:2692, drilling and tapping cost iron pipe lines of all diameters and screwing in ferrule,GI Nipple including excavation complete in all respect
Credit for old Floating arms
Credit for old 100 mm i/d Sluice valves
Credit for old 150 mm i/d Sluice valves
DEEPAK SINGLA CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .