| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹24.0 L+₹1.1 L (4.77%)Rejected-Finance CHOLADHARA JORAHAT 785001 ASSAM | JORHAT | ASSAM | 785001 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹25.3 L+₹2.4 L (10.5%)Rejected-Finance C O DR UMASHANKAR SHARMA RANGIYA TINIALI NEAR RAIL GATE POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹25.9 L+₹3.1 L (13.3%)Rejected-Finance A 306 SAISHA RESIDENCY PLOT NO 99 SECTOR 35 KAMOTHE RAIGAD MAHARASHTRA 410209 UDYAM MH 27 0136235 | RAIGAD | MAHARASHTRA | 410209 | L4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L5₹26.9 L+₹4.0 L (17.6%)Rejected-Finance B 1 16 MILAN GARDEN SABHAPUR EXTENSION NEAR BHIKAM SINGH TUBE WELL NEW DELHI 110094 | NORTH EAST | DELHI | 110094 | L5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
5 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE RANGIA
GE Rangia C/O 99 APO Rangia
REPAIR/REPLACEMENT OF LT ELECTRIC POLE, LT OVERHEAD LINE AND CONNECTED WORKS AT RANGIA AND CHANGSARI MILITARY STATION UNDER GE RANGIA
2022_MES_556917_1
8617/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RANGIA AND CHANGSARI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE RANGIA
₹52,000
Yes
26 Nov 2022
10 Oct 2022
7 Nov 2022
10 Oct 2022
5 Nov 2022
24 Oct 2022
Amount
Dismantling LT over head ACSR conductor of any size including separating, serviceable conductor and kept in safe custody for re-use in the work and removing unserviceable conductor from the site complete all as specified and as directed by Engineer-in-charge.
S&F aluminum conductor steel reinforced (ACSR) on over head LT electric line with stretching and tensioning the same with required span sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2mm dia complete all as specified and as directed by Engineer-in-charge.
Restringing only of old serviceable ACSR conductor obtained from serial item no. 01 above including binding complete all as specified and as directed by Engineer-in-charge.
Dismantling of cross arms fixed on Steel tubular poles carefully including separating and getting aside, serviceable cross arms for re-use in the work and removing unserviceable cross arms from site complete all as specified and as directed by Engineer-in-charge.
S&F cross arms made out of mild steel channel or angle section of reqd size and shape including clamp back plate with bolts, nuts and washers drilled for insulator bolts welding bending cold or hot in any shape or size as directed and painted with two coats of aluminium paint over a coat of red oxide primer after necessary preparation of surfaces complete all as specified and as directed by Engineer-in-charge.
Fixing only old serviceable cross arms obtained from Sch `A’ serial Item No. 4 here-in-before with providing new bolts, nuts and washers as required including painting with one coat of aluminium paint after preparation of old surfacecomplete all as specified and as directed by Engineer-in-charge.
Dismantling of LT insulators of any type and size from position and removing unserviceable insulators from site complete all as specified and as directed by Engineer-in-charge.
S&F pin type insulator porcelain vitreous, white, brown or green insulator including one galvanized mild steel spindle two galvanized iron washer and one galvanized iron nut 100mm height 65mm dia for 1100 volts grade complete all as specified and as directed by Engineer-in-charge.
Fixing only old serviceable pin type insulator dismantled under item No. 07 of the above.
S&F shackle type porcelain vitreous white, brown or green insulator of size 75mm height, 90mm dia (maximum) including mild steel straps of section 31mmx3mm, washers, 12mm dia insulator bolt and nut suitable for working pressure 1100 volts grade complete all as specified and as directed by Engineer-in-charge.
Fixing only old serviceable shackle type insulator dismentaled under serial Item No. 07 of the above.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete including excavation of earth work as required and removing the same from site complete all as specified and as directed by Engineer-in-charge.
S&F stay assembly complete with all accessories and stay clamps all as shown in electrical plate No. 1 of SSR Part I with using stay rod of 16 mm dia., 1.8 m long and stay plate galvanised steel of size 23 cm x 23 cm x 6 mm thick complete all as specified and as directed by Engineer-in-charge. Note - Loop type insulator, stay clamps, excavation and concrete measured and paid separately.
S&F galvanized stay wire (stay strand) of size 7 / 3.15 mm with properly tightening the same complete all as specified and as directed by Engineer-in-charge.
S&F small size loop type insulator vitreous porcelain white, brown or green large size with overall dimensions 65 x 90mm and clearance of hole 16mm complete all as specified and as directed by Engineer-in-charge.
Dismantling of old unserviceable bending/broken steel tubular pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation of earth work as required and removing the same from site complete all as specified and as directed by Engineer-in-charge. Note- Dismantling of cross arms and insulators fixed on pole shall be measured and paid separately.
Supply and erection of steel tubular swaged poles 9.0 metre long, type 410 SP-31 in true verticle position complete with cast iron base plate, final taper plug, bolts, nuts and screws, pole cap, etc. confirming to IS-2713 of 1980 including painting with two coats of black bituminious paint throughout internally and externally upto the planting depth and the remaining portion of exterior surface shall be painted with two coats of aluminum paint over a coat of red oxide primer after necessary preparation of surfaces and numbering to be done in black synthetic enamel paint complete all as specified and as directed by Engineer-in-charge.
M&L for preparing of old painted surface of steel tubular electric pole 9 mtr long (effective painted length from top of foundation concrete to top of pole) including struts cross arms clamp, etc fitted on pole and applied one coat of aluminum paint after properly cleaned with sandpaper/wire brushes and including making alternate white and black strips 30 cms height (05 Nos strips) numbering of the poles by 2" height letters complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft/loose soil, complete all as specified and as directed by Engineer-in-charge.
Removing excavated materials (soils) not exc. 50.00 m and deposited where directed at a level not exc. 1.50 M above the starting point in soil, complete all as specified and as directed by Engineer-in-charge.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed by Engineer-in-charge. Note - Only punned thickness shall be measured and paid.
Supply & laying of GI pipe 40 mm bore light grade for protection of UG cable complete all as specified and as directed by Engineer-in-charge.
Supply & laying of GI pipe 50 mm bore light grade for protection of UG cable complete all as specified and as directed by Engineer-in-charge.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
Supply, fixing, testing and commissioning of 185 Sqmm, 3.5 Core XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100Volt grade on walls/floor/trenches with fixing acessories including taking down old unserviceable XLPE cable, brick bats or pre-cast cable cover & GI pipe used for cable protection complete all as specified and as directed by Engineer-in-charge. Note - Earthwork, sand cushioning, bricks, GI pipe, etc. shall be measured and paid separately.
All as per serial item no. 26 above but cable of size 120 Sqmm 3.5 core.
All as per serial item no. 26 above but cable of size 50 Sqmm 3.5 core.
All as per serial item no. 26 above but cable of size 35 Sqmm 3.5 core.
Cutting of road for laying of GI pipe/Cable upto 0.60 mtr deep and making good the disturbed surface to match with the existing finish complete all as specified and as directed by Engineer-in-charge.
Cutting and trimming of tree branches, bushes n.exc 3 m girth all along LT overhead lines/guard wire and removing branches out of defence land complete all as specified and as directed by Engineer-in-charge. Note:- One metre lenght comprising of 6 feeder of 2/4 conductors each shall be measured and paid as one unit.
S&F PVC line separator of 10 mm dia fixed on LT over head line of 4 span including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F PVC line separator of 10 mm dia fixed on LT over head line of 3 span including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F PVC line separator of 10 mm dia fixed on LT over head line of 2 span including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F 1100 Volts grade heavy duty cable PVC insulated stranded 10 Sqmm aluminium conductor served with inner sheathing of PVC cape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 m apart including 4 mm dia suspension wire one twin core cable flat or circular including taking out old unserviceable cable complete all as specified and as directed by Engineer-in-charge.
S&F 1100 Volts grade heavy duty cable PVC insulated stranded 16 Sqmm aluminium conductor served with inner sheathing of PVC cape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 m apart including 4 mm dia suspension wire one twin core cable flat or circular including taking out old unserviceable cable complete all as specified and as directed by Engineer-in-charge.
S&F cable jointing kit for 1100V (earthed) grade cable Straight joint type complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 95-150 Sqmm including taking down the old unserviceable one, complete all as specified and as directed by Engineer-in Charge.
S&F cable jointing kit for 1100V (earthed) grade cable Straight joint type complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 240-300 Sqmm including taking down the old unserviceable one, complete all as specified and as directed by Engineer-in Charge.
M&L for earthing complete incl necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip of size 25 x 4mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanised iron 15 mm dia. light grade pipe and watering pipe shall be 20 mm of medium grade pipe with pre-cast RCC cover, charcoal/salt funnel etc. including taking down the old unserviceable one, complete all as specified and as directed by Engineer-in Charge. NOTE : The conctrete pit shall be PCC 1:3:6, type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No. 3 of MES SSR Part-1. (ii) Item includes the cost of 7.5 m GI pipe for protection of earth wire. (iii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pipt itself and the extra cost of additional length of watering pipe, bends , elbows etc. shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length galvanised earth strip .
All as per serial item no. 39 above but using galvanised iron strip 32×6mm as earthing lead.
S&F in repair power factor controller relay 1CT IPFC CS 1001-108-90V/550 Vzc 144x144 in existing APFC panel L&T insulated including necessary connection and taking down old unserviceable one, complete all as per specified and as directed by Engineer-in- charge.
S&F in repair MCCB 4 Pole, 415 Volt, 63 Amp with breaking capacity 16 KA, including extended terminal & suitable size of cablelugs complete all as directed & specified by Engineer -in-Charge.
S&F in repair MCCB 4 Pole, 415 Volt, 100 Amp with breaking capacity 16 KA, including extended terminal & suitable size of cablelugs complete all as directed & specified by Engineer -in-Charge.
S&F in repair MCCB 4 Pole, 415 Volt, 125 Amp with breaking capacity 16 KA, including extended terminal & suitable size of cablelugs complete all as directed & specified by Engineer -in-Charge.
S&F in repair MCCB 4 Pole, 415 Volt, 160 Amp with breaking capacity 36 KA, including extended terminal & suitable size of cablelugs complete all as directed & specified by Engineer -in-Charge.
S&F in repair MCCB 4 Pole, 415 Volt, 200 Amp with breaking capacity 36 KA, including extended terminal & suitable size of cablelugs complete all as directed & specified by Engineer -in-Charge.
S&F in repair MCCB 4 Pole, 415 Volt, 250 Amp with breaking capacity 36 KA, including extended terminal & suitable size of cablelugs complete all as directed & specified by Engineer -in-Charge.
S&F in repair MCCB 4 Pole, 415 Volt, 400 Amp with breaking capacity 36 KA, including extended terminal & suitable size of cablelugs complete all as directed & specified by Engineer -in-Charge.
S&F of street light thermoplastic cable junction box of size 200 x 150 x 90 mm IP 66/67, weather proof for outdoor installation with TPN terminal and MCB SP 6 amps suitable for cable entry upto 4 core 16 sqmm complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
Technolinks
M/S S.S. Construction
R C TRADING COMPANY
M/S K D TURAIHA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .