| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-Finance | L1 | Accepted-Finance Qualified | |
| 2 | L2₹25.6 L+₹100 (<0.01%)Accepted-Finance | L2 | Accepted-Finance Qualified | |
| 3 | L2₹25.6 L+₹100 (<0.01%)Accepted-Finance | L2 | Accepted-Finance Qualified | |
| 4 | L2₹25.6 L+₹100 (<0.01%)Accepted-Finance | L2 | Accepted-Finance Qualified | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to non compliance of Tecjnical specification |
| Sl No | Description | Qty | Unit | M/S MUZAFFAR AHMAD NAIK L2 | M/S KHAN ELECTRICAL ENTERPRISES L2 | M/S HILAL ENTERPRISES L2 | M/s NEW DAR ELECTRICALS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, Testing and Commissioning of 3-phase 25 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate | 1 | Nos | 1,04,800 ₹1,04,800 Lowest | 1,05,000 ₹1,05,000 | 1,05,000 ₹1,05,000 | 1,05,000 ₹1,05,000 |
| 2.00 | Supply, installation, Testing and Commissioning of, 3-phase 63 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate | 1 | Nos | 2,00,150 ₹2,00,150 | 1,99,950 ₹1,99,950 Lowest | 1,99,950 ₹1,99,950 Lowest | 1,99,950 ₹1,99,950 Lowest |
| 3.00 | Supply, installation, Testing and Commissioning of, 3-phase 100 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate | 1 | Nos | 2,35,999 ₹2,35,999 Lowest | 2,35,999 ₹2,35,999 Lowest | 2,35,999 ₹2,35,999 Lowest | 2,35,999 ₹2,35,999 Lowest |
| 4.00 | Supply, installation, Testing and Commissioning of, 3-phase 200 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate | 1 | Nos | 3,99,950 ₹3,99,950 Lowest | 3,99,950 ₹3,99,950 Lowest | 3,99,950 ₹3,99,950 Lowest | 3,99,950 ₹3,99,950 Lowest |
| 5.00 | Supply, installation, Testing and Commissioning of, 3-phase 250 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate | 1 | Nos | 5,99,000 ₹5,99,000 Lowest | 5,99,999 ₹5,99,999 | 5,99,999 ₹5,99,999 | 5,99,999 ₹5,99,999 |
| 6.00 | SITC of 11 Mtr long ST Poles 410, SP-56 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders. | 1 | Nos | 30,999 ₹30,999 | 30,000 ₹30,000 Lowest | 30,000 ₹30,000 Lowest | 30,000 ₹30,000 Lowest |
| 7.00 | SITC of 9 Mtr long ST Poles 410, SP-33 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders. | 1 | Nos | 21,400 ₹21,400 | 21,500 ₹21,500 | 21,500 ₹21,500 | 20,900 ₹20,900 Lowest |
| 8.00 | SITC of 8 Mtr long ST Poles 410, SP-15 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders. | 1 | Nos | 17,000 ₹17,000 | 16,900 ₹16,900 Lowest | 16,900 ₹16,900 Lowest | 17,400 ₹17,400 |
| 9.00 | SITC of 8 Mtr long PCC Poles including manual, mechanical carriage, excavation of pole pits with inscription of permenent marking on each pole "Name of scheme-2019-20/xx" (xxx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place | 1 | Nos | 5,450 ₹5,450 Lowest | 5,500 ₹5,500 | 5,500 ₹5,500 | 5,500 ₹5,500 |
| 10.00 | Providing & fixing of pole earthing as per REC standard as per J-1 (spiral earthing) drawing | 1 | Nos | 1,000 ₹1,000 | 950 ₹950 Lowest | 950 ₹950 Lowest | 950 ₹950 Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
18 Aug 2025, 11:00 amClosed
Executive Engineer
ED Awantipora
Stage contract for Carrying out various electrical maintenance works including SITC, ITC of various Line materials and Distribution Substations and dismantling of existing deteriorated out lived electrical infrastructure for the year 2025-26 under th
2025_PDD_282741_1
EDA 17 of 25-26 Dated 29-07-25
Open Tender
Electrical and Maintenance Works
Lump-sum
300 days
Awantipora
Please refer to SBD
2 documents required · 2 mandatory
₹1,000
Yes
Executive Engineer, ED Awantipora
₹60,000
Yes
29 Sept 2025
29 Jul 2025
18 Aug 2025
29 Jul 2025
18 Aug 2025
30 Jul 2025
30 Jul 2025 - 30 Jul 2025
Amount
Supply, installation, Testing and Commissioning of 3-phase 25 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate
Supply, installation, Testing and Commissioning of, 3-phase 63 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate
Supply, installation, Testing and Commissioning of, 3-phase 100 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate
Supply, installation, Testing and Commissioning of, 3-phase 200 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate
Supply, installation, Testing and Commissioning of, 3-phase 250 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate
SITC of 11 Mtr long ST Poles 410, SP-56 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders.
SITC of 9 Mtr long ST Poles 410, SP-33 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders.
SITC of 8 Mtr long ST Poles 410, SP-15 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders.
SITC of 8 Mtr long PCC Poles including manual, mechanical carriage, excavation of pole pits with inscription of permenent marking on each pole "Name of scheme-2019-20/xx" (xxx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place
Providing & fixing of pole earthing as per REC standard as per J-1 (spiral earthing) drawing
Supply,Fixing of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mm
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Providing, errection, testing & commissioning of channel cross arms, V-Cross arms, Sub-station channels & Angle Iron Braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of Galvanized Iron of different sizes (REC Standard) & to be fixed with GI Nuts & Bolts and washers.
Providing, errection, testing & commissioning of channel cross arms, V-Cross arms, Sub-station channels & Angle Iron Braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of Mild Steel of different sizes (REC Standard) & to be fixed with GI Nuts & Bolts and washers.
Providing & and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN)
Providing & fixing of 11 kV, G.O AB Switch , 3-phase, 200A (09 insulator post type) with arragement for pad locks & operating rod . The operating rod should be G.I Pipe (B-class) of 25 mm dia of requisite length.
Providing & fixing of 11 kV Horn, Gap Fuse 3-phase 100A
Providing & fixing of 11KV Link set 3-phase, 200 A (station type)
SITC of 11KV Isolator Double Break, 3-pole, 630 Amps, Horizontal Mounting Type , with earth switch
Providing & fixing Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type
Providing & fixing of LT Fuse set OF SUITABLE CAPACITY FOR 63KVA,100KVA,200KVA (as per tender drawing attached)
Providing & fixing of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN)
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 400 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 300 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 120 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 95 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
SITC of 35 mm² AB (HT) Cable (3x35+1x70 insulated) mm² XLPE (11 kV, 3C + Earth)
SITC of 50 mm² AB (HT) Cable (3x50 + 1x70 insulated )mm² XLPE (11 kV, 3C + Earth)
SITC of 70 mm² AB (HT) Cable (3 x 70 + 1x95 insulated )mm² XLPE (11 kV, 3C + Earth)
SITC of 120 mm² AB (HT) Cable (3x120 + 1x95 insulated)mm² XLPE (11 kV, 3C + Earth)
SITC of 35 mm² AB (LT) Cable ( 3 x 35 + 1 x 16 + 1 x 25 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
ITC of 35 mm² AB (LT) Cable ( 3 x 35 + 1 x 16 + 1 x 25 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
SITC of 50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 insulated)mm² XLPE (1.1kV, 3+1 C, Al)
ITC of 50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 insulated)mm² XLPE (1.1kV, 3+1 C, Al)
SITC of 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
ITC of 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
SITC of 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
ITC of 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
Providing, fixing , testing & commissioning of cable kits ( heat shrinkable) 35 sq.mm upto 120 sq.mm 3 Phase
Providing & fixing of Suspension/Tension clamps with eye hooks assembly
Providing & fixing of IPC's
Providing and fixing of Anticlimbing devices on poles of GI barbed wire type devices). At-least 3.5 kgs GI barbed wire(12 SWG)
Providing and fixing of Danger Plates on poles with clamps and writing in English and Regional Language
Providing & fixing of Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per REC standard.
Providing, laying of Cement bottoming 1:2:4 mix as per Standards 0.66 cum/pole ( 11 Mtr Pole )
Providing, laying of Cement bottoming 1:2:4 mix as per REC standards 0.48 cum/pole including muffing 20 cm above ground level, plaster and curing of concrete.
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.40 cum per pole for ( 8 Mtr)
Providing & fixing of bi-metallic clamps for fixing of LT cable with distribution transformers having capacity upto 100 kVA
Providing & fixing of bi-metallic clamps for fixing of LT cable with distribution transformers having capacity of 25 KVA & above
Providing & fixing of 300 mm sq Aluminum Thimbles for cable terminations
Providing & fixing of 185 mm sq Aluminum Thimbles for cable terminations
Providing & fixing of 120 mm sq Aluminum Thimbles for cable terminations
Providing & fixing of 95 mm sq Aluminum Thimbles for cable terminations
Providing and and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 for neutral earthing and 25X3 mm for 2 transformer body earth, two no. pole earth, 1 no. LA Earth and 1 no. GO handle earth as per REC approved construction standards with F5, F10 & J2 drawings issued by REC as reference. Each electrode to be connected through double GI strips to be fixed on baby insulators. The termination should be bolted and not welded.
SITC of LT Distribution Box for 25 kVA DTR with 40 Amp MCCB 3P 16 kA for incomer & 25 Amp MCCB 3P 16 kA/10 kA 1 No. each (=2No.) for Outgoing Circuits .
SITC of LT Distribution Box for 63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits
SITC of LT Distribution Box for 100 kVA DTR with 160 MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits
SITC of LT Distribution Box for 200 kVA DTR with 315 Amp MCCB Circuits 3P 16 kA 3 No.s
SITC of LT Distribution Box for 250 kVA DTR with 400 Amp MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 1 No. and 160 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits
Providing and fixing of Shackle Insulators (Porcealin) ( 16 KN) with LT U Clamps complete
Providing & and fixing of 11 kV Pin Insulators (porcealin) with G.I. Pins ( 5 KN)
Providing and fixing of Shackle Insulators ( 16 KN) with Mukhi Clamp of GI flat iron (50*6)mm to be fixed without drilling/punching of poles on ST poles.
Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.1 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices
Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.05 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices
Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.0.3 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices
Loading, Transportation, Installation, Testing and Commissioning of Single Phase Energy Meter 5-30 Amp/ 10-60 Amp, DLMS Complaint of accuracy class 1.0 The job includes installation/fixing of meters on poles with painted (1 coat Redoxide and 02 coats of Al Paint) MS Flat/iron/clamp of sizes 25*3 mm alongwith GI Nuts & Bolts)
Supply, Installation, Testing and Commissioning of 16 mm2 PVC service cable armoured 2 Core 3 mtr per consumer
Loading, Transportation, Errection,testing & commissioning, Carriage and Delivery at Site of 11 Mtr long ST Poles SP-56 including excavation of pole pits, refilling the pit with soil, boulders.
Loading, Transportation, Errection,testing & commissioning ,Carriage and Delivery at Site of 9 Mtr long ST Poles SP-33 including excavation of pole pits, refilling the pit with soil, boulders.
Loading, Transportation, Errection,testing & commissioning, Carriage and Delivery at Site of 8 Mtr long ST Poles SP-15 including excavation of pole pits, refilling the pit with soil, boulders.
Loading, Transportation, Errection, testing & commissioning, Carriage and Delivery at Site of 8 Mtr long PCC Poles including excavation of pole pits, refilling the pit with soil, boulders
Providing & fixing of 11 kV Disc Insulators (porcealin) type with G.I fittings( 45 KN)
Loading, Transportation, Installation, Testing, Commissioning of 25 kVA Distribution Transformer including mechanical/manual carriage upto site of installation and fixing of all fittings and jumpers
Loading, Transportation, Installation, Testing, Commissioning of 63/100 kVA Distribution Transformer including mechanical/manual carriage upto site of installation and fixing of all fittings and jumpers
Loading, Transportation, Installation, Testing, Commissioning of 200/250/400 kVA Distribution Transformer including mechanical/manual carriage upto site of installation and fixing of all fittings and jumpers
Loading, Transportation, Laying, stringing, tensioning and binding of conductor ACSR 0.1 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site.
Loading, Transportation, Laying, stringing, tensioning and binding of conductor ACSR 0.05 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site.
Loading, Transportation, Laying, stringing, tensioning and binding of conductor ACSR 0.03 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site.
Errection, testing & commissioning of channel cross arm, V-Cross arms, Sub-station channels & Angle Iron Braces, transformer beltings etc to be fabricated out of Mild Steel of different sizes & to be fixed with GI Nuts & Bolts and washers.
Dismentling of 11 Mtr long ST Poles including carriage to divisional stores,
Dismentling of of 9 Mtr long ST Poles including carriage to divisional stores,
Dismentling of of 8 Mtr long ST Poles including carriage to divisional stores,
Dismentling of of PCC Poles including carriage to divisional stores without damaging / breaking the pole. If the pole gets damaged no payment will be made.
Dismentling of of wooden Poles including carriage to divisional stores,
Repositioning of 11 mt ST tilted poles
Repositioning of 9 mt ST tilted poles
Repositioning of 8 mt ST tilted poles
Repositioning of PCC tilted poles
Repositioning of tilted wooden poles
Dismantling of conductor ACSR 0.1 including hardware fittings and returning the dismantled material to stores.
Dismantling of conductor ACSR 0.05 including hardware fittings and returning the dismantled material to stores.
Dismantling of conductor ACSR 0.03 including hardware fittings and returning the dismantled material to stores.
Re-stringing, tensioning and binding of conductor ACSR 0.1 including fixing of hardware fittings and jointing as per standard practices
Re-stringing, tensioning and binding of conductor ACSR 0.05 including fixing of hardware fittings and jointing as per standard practices
Re-stringing, tensioning and binding of conductor ACSR 0.03 including fixing of hardware fittings and jointing as per standard practices
Branch cutting
Opening of connections /lifting from bed, Loading of damaged Distribution Transformer of Capacities 25/63/100 KVA & Reinstallation of same after Repairs
Opening of connections /lifting from bed, Loading of damaged Distribution Transformer of Capacities 250 KVA & Reinstallation of same after Repairs
Dismantalling ,Dragging Loading ,unloading of ST 9 mtr long Poles and transportation and re errection of the same at new sites
Dismantalling ,Dragging Loading ,unloading of ST 8 mtr long Poles and transportation and re errection of the same at new sites
Dismantalling,Dragging & reinstallation of old 250 KVA Transformer
Dismantalling,Dragging & reinstallation of old 63/100 KVA Transformer
Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection
M/S MUZAFFAR AHMAD NAIK (BID ID -2429811)
M/S KHAN ELECTRICAL ENTERPRISES (BID ID -2444198)
M/S HILAL ENTERPRISES (BID ID -2444557)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .