Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹27.8 L+₹1.1 L (4.06%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹30.3 L+₹3.6 L (13.3%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹30.3 L+₹3.6 L (13.4%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹37.4 L+₹10.7 L (40.0%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
1 May 2021, 6:00 pmClosed
ARJUN PATRO IDSE
GE U ELECTRIC SUPPLY DELHI CANTT
REPAIR REPLACEMENT OF DAMAGED LT CABLE BUS BAR CHAMBER POLE BOX POLE PAINTING EARTHING AND CONNECTED ITEMS AT CVD PIRU VIHAR DIPAC HQ TG VIKRAM BATRA LINE CMP LINE CHITRAL LINE BASANTAR LINE EME UNIT LINE KABUL LINE BAIRD PLACE KOTWALI LIN
2021_MES_431707_1
GE ELECT/D-15/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹99,000
Yes
7 Jun 2021
5 Apr 2021
3 May 2021
6 Apr 2021
1 May 2021
19 Apr 2021
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil) for laying of cables or GI pipe and getting out including levelling of bottom suface to required level complete all as specified and directed NOTE:- Excavation & Earthwork shall be carried out on ground manually.
All as per Serial item No '1' here in before but hard/dense soil.
All as per Serial item No 1 here in before but depth exceeding 1.5 mtr and not exceeding 3.00 mtr.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables and in substation ducts for cushioning of cables etc, complete all as specified. (Measurement should be after punning down)
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sq cm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Laying only old using old bricks obtained under srl item No'1' here in before.
Returning filling in,. including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed
Material & labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate . in mass concrete and filling complete for foundation of pad of pole all as specified & directed by Enge-in- Charge
Material & labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate . in mass concrete and filling complete for foundation of Panel & Transformer yeard, pole/stay/ of pole all as specified & directed by Enge-in- Charge
Material & labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping for replacement of new pole and breaking old existing coping and like including weather slightly rounded or chamfered angles and throaty and necessary form work complete for pole ,all as specified and directed by Engr-in-charge.
Demolition of path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Material and labour for Cement Concrete type B-2 mix, 1:2:4 (40mm graded aggregate) 150mm thick, finishing the top surfaces fair and even complete all as specified and as directed.
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends all specified and directed
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified of size 100 mm dia.
All as per item No 15 here in before but of size 80 mm dia
All as per item No 15 here in before but of size 50 mm dia
All as per item No 15 here in before but of size 40 mm dia
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098, Part-II marked, laid in trenches/ duct/ under road/ footpath/ etc complete all as specified and directed. Cables of the following size 16 Sqmm 4 core. Locatio :- CVD parameter, Baird place, Offr Enclave etc
All as per srl item No 19 here-in-before but of size 25 Sqmm 4 core Location:- CVD M/Gate, Guard Post No-1, Kabul Line, Vikram Batra Vihar etc
All as per srl item No 19 here-in-before but of size 35 Sqmm 4 core Location:- CMP Qtr, Baird Place, GE (N) etc
All as per srl item No 19 here-in-before but of size 50 Sq mm 3.5 core. Location:- Kabul Line , Kotwali line etc
All as per srl item No 19 here-in-before but of size 70 Sq mm 3.5 core. Location:- S/F Qtr, kabul line etc
All as per srl item No 19 here-in-before but of size 95 Sqmm 3.5 core Location:- GE (E), CEDZ mess etc
All as per srl item No 19 here-in-before but of size 120 Sqmm 3.5 core Location:- CVD, Vikram Vatra Vihar, Kabul line etc
All as per srl item No 19 here-in-before but of size 185 Sqmm 3.5 core Location:- CVD, Basatar Line , kabul line etc
All as per srl item No 19 here-in-before but of size 240 Sqmm 3.5 core Location:- Vikram Batra Vihar, baird place, Kabul Line, SF Qtr etc
All as per srl item No 19 here-in-before but of size 300 Sqmm 3.5 core Location:- CVD etc
Dismantling the over head ACSR of street light from PCC pole of any size.
Supply, laying, jointing, testing and commissioning in replacment of over head conductor of any size 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors,IS-7098, Part-II marked, laid in trenches complete all as specified and directed. Cables of the following size 16 Sqmm 4 core. Note:- for item No 19 to 28, 30:- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately. Location :- Kabul Line area, CVD Area
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :- 25 to 50 Sqmm x 3.5 core/ 4 core
All as per item No 31 here in before but size 70 to 150 Sqmm x 3.5 core
All as per item No 31 here in before size 185 to 240 Sqmm x 3.5 core
Supply and Installation of LT CT operated Trivector Meter in replacement with the following specifications: Meter Type: LT 3 Phase 4 Wire Electronic Tri vector Meter, Standard: IS 13779:1999 / CBIP 88, Accuracy: Class 1.0, Voltage and Current rating: (i) Reference Voltage - 415V for LT Meter, (ii) Basic Current (Ib) - 5 A, Maximum continuous current (Imax) - 10 A, Rated Frequency (variation) - 50Hz (±5%), Power consumption: (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency, (ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature, Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height Display in the event of Power Failure: Internal battery back-up for LCD display, Communication port: (i) Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is provided (ii) RS 485 for DLMS protocol, Energy recording - Unidirectional, Instantaneous parameters (30 Min) - Each Phase Current, Each Phase Voltage, Each Phase Power, Each Phase Power Factor, Each Phase Reactive Power, Power, Power Factor, Apparent Power, Reactive Power, Frequency, Load survey (30 Min) parameters - Energy, Apparent Energy, Daily Survey: Cumulative Energy, Cumulative Apparent Energy.
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Material and Labour for disconnecting burnt end or burnt portion of cable, removing the cable from loop with and including necessary excavation & earth work, relaying and re-connecting the cable by removing burnt portion of cable and preparing fresh terminals including fixing of new lugs for 50 Sqmm 3½ / 4 to 400 Sqmm of LT cable at Poles/Main switch etc complete all as specified and directed.
Dismantling the existing unserviceable (damaged/broken) PCC electric pole of any type and size, from ground after necessary excavation & breaking of concrete foundation & encasing the pole including making good the disturbed surfaces complete all as specified and directed.
Supplying & Erecting Steel Tubular Pole 410 SP-31 (9 metres long) complete with cast iron base plate all as specified in IS 2713 of 1980 (Part I & II) including painting of Poles with one coat of red oxide primer and one coat of aluminum paint before fixing and one coat of aluminum paint after fixing. The complete embedded portion shall be painted with two coats of black bituminus paint. (Note:- The necessary earth work and PCC work will be measured and paid separately under respective items.) Location:- Piru Vihar, Vikram Batra Vihar, Baird Place, Kabul Line, Offr Enclave
Preparation of old painted surfaces of LT PCC poles for cross arms, MS strap, nuts, bolts, washers, cable protection pipe wherever provided etc and painting with one coat of aluminium paint and painting of bottom area of pole upto 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and directed. Location :- CVD
Supply & fixing in replacement KIOSK Box weather proof made up of one piece mounted on SMC base and door pole mounted hinged door of size 333 x233x 120 mm outside and 300 x 200 x105 mm inside dimension comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 6 Amp fuse grip with base for controlling the steet light fitting and FL clamps 30x4mm with necessary MS nuts bolts and washers and including applying two coasts of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface and including embassing/painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as directed. Location :- CVD, Piru Vihar, Vikram Batra Line, Kabul Line area
Earthing complete in replacement with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (Earth pit not less than 3.5 meter deep below ground level) with top edge of plate not less than 2.5 meter below normal ground level, connected with and including galvanised iron earth strip 32 X 6mm by means of nuts, bolts, check nuts and washers of galvanised iron or steel and provisions of charcoal dust and common salt packed all around the earth plate and testing on completion complete all as specified, directed and shown in Electrical Plate number 3 of MES SSR Part-I NOTES : The quoted rates shall be deemed to include the cost of (a) Excavation and earth work in any type of Soil. (b) PCC pit in cement concrete 1:3:6 mix, type B-1, Pre cast RCC cover with suitable handle, 40 mm thick in RCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/Sq metre. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc (d) 40 mm nominal bore medium grade GI protection pipe 7.50 m long for protection of earthing lead (e) Requisite quantity of common salt and charcoal in alternate layers completely packed as directed. (f) Testing of earthing on completion. Location :- kabul Line Area, CVD area
Supplying and fixing in replacement, galvanised iron strip 32 X 6 mm burried in ground for additional earthing lead beyond 7.5 meter if required.
Supplying and fixing (in replacement) factory made and tested, Bus bar chamber, outdoor pedestal type, suitable for LT 415 volts 3 phase 4 wire, 50 Hz , AC supply system, having duly insulated four Nos aluminum bus bars, of rating 600 Amps , installed on epoxy / SMC type insulator The panel shall be dust and vermin proof, IP-65 Protection class and made of 3.15 mm CRCA MS sheet and 40x40x5mm thick angle iron base frame work, suitable for connection of two nos LT cable of size 3.5 core 300 Sqmm, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement of minimum size 65cm x 65cm x 40cm ( boxsize excluding legs) and mounted on angle iron pedstal 45 cms above groungd level all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc incl necessary PCC work for foundation as directed. Location:- Baird Place, Kabul Line area
Supplying and fixing in replacement of old street light fitting any type, LED street light fittings, 60 Watt, IP-65 complete complete all as specified and as directed. Location:- Piru Vihar, Vikram Batra Vihar, Baird Place, Kabul Line, Offr Enclave
Material and labour for carrying out balance distribution of load on LT Lines by checking the existing load on the feeder (3 phase,4wire system) and accordingly shifting & connecting service cables to another phase conductor in accordance with balancing of Electric load. submit feeder wise report for before load balancing and after load balancing including maintenance of LT panel i.e. titening of all nuts, bolts, washers, cleaning of LT panel dust etc complete all as specified and directed by Engr-in-Charge.
Taking down existing worn out/old/broken ACSR conductors of any size and length at any position from LT poles and supply, fixing and stretching new ACSR conductors of any size and type for over head LT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and directed by Engr in charge. Location :- CVD
Taking down existing worn out/rusted GI earth wire, cradles, guards of any size and shape at any position from LT poles and Pre stressed concrete poles 9 meters long and stretching new GI earth wire 8 SWG (4 mm dia) on LT poles for continuous earth wire/guards and cradles (hexagonal/rectangular) including 1.6 mm GI binding wire etc complete all as specified and directed by Engr in charge.
Supply and fixing in renewal of 3 pole power contactor ML-6 Cat No SS90921 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor complete all as directed.
Supply and fixing in renewal of 3 pole power contactor MNX-110 Cat No CS94137 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor complete all as directed.
Supply and fixing in renewal of Analog Time switch Cat No J648B1, 240 Volt AC , 50 Hz , mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable time switch complete all as directed.
Supply drawing, connecting and testing in replacement 3 core, 1.0 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable of size 16 Sqmm flat complete all as specified ad directed.
All as per Sr item No 52 here in before but of size 10 Sqmm.
All as per Sr item No 52 here in before but of size 6 Sqmm.
Preparation of old painted surfaces of Steel tubular LT poles, any height including cross arms, MS strap, nuts, bolts, washers, cable protection pipe wherever provided etc and painting of complete poles with one coat of aluminium paint from 2.1 m above ground level to top of pole including cross arms and protection pipe and painting of bottom area of pole upto 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and directed. Location:- Piru Vihar, DIPAC, Baird Place, kabul Line area, CVD Area
Disconnecting LT connection, junction box ,taking down steel tubular Pole ,9 metres long carefully by excavation, after demolition of PCC and Material & labour for shifting of to another place as directed complete with cast iron base plate all as specified . (Note :- The above quoted rate is included for T & P , man power etc. The necessary earth work and PCC work will be measured and paid separately under respective items.) Location :- Piru Vihar, Baird Place
Material and labour in replacement for ATS 4 pole of capacity 315 Amps including enclosure & controller complete including fixing arrangement i.e suitable size of MS flat, nuts, bolts, washer, fixing of LT cables of any size with suitable size of lugs all as specified and directed. Location :- kabul Line area
Supply and fixing OFF load change over switch in replacement of capacity 315 Amps, four pole, 415 volts, AC, 50 Hz.
Supply and fixing OFF load change over switch in replacement of capacity 160 Amps, four pole, 415 volts, AC, 50 Hz.
M&L for boring of holes of size 100 mm dia, under road/pavement/hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe 100m dia complete all as specified and directed.
Supply & fixing Street light bracket suitable for PCC/ Steel Pole made to shape out of GI pipe 40 mm bore light grade, 1.5 mtr length and fixed in replacement with MS Calmps of size flat MS iron 50 mm x 6 mm , nuts, bolts and washers on pole complete.
Supply & fixing in replacement SS enclosure in-built neutral link, incl MCCB of cap 125 Amp 4 pole, 25 KA complete all as specified and directed.
Supply & fixing in replacement SS enclosure in-built neutral link, incl MCCB of cap 250 Amp 3 pole, 36 KA complete all as specified and directed.
Prunning/trimming the branches of trees if any along LT overhead line/ street light pole, 3 mtr on all side below/above/sides of LT overhead line and removing the same upto 150 mtr away each span not exceeding 50 mtr complete all as specified and directed by Engineer-in-Charge (The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required).
Stringing/stretching incl jointing in situ of different sizes of ACSR or GI earth continuity conductors with/ without guarding wires on LT electric poles at different locations all as ordered manually or by mechanical means to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete as ordered :-
ACSR of different size e.g Squirrel, weasel, ferret, etc.
GI Earth continuity/Guarding wire 4 mm /3.15 mm dia.
Material & labour providing shackle type insulator LT 1100 volt grade porcelain vitreous white or brown including insulator bolts, nuts 12 mm dia, 75 mm height and 90 mm dia of insulator complete all as specified and directed by Engineer-in-Charge.
Disconnecting LT cables and M & L for shifting of LT Panel of any size/capacity and reinstall with all connections, necessary foundation to another site all as specified and directed by Engr In charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
MV Engineers And Contractors
mayur enterprises
Vijay Electricals
Buddham Builders
Rajindera Enterprises
Ridhi engineers and builders
SANJEEV ENTERPRISES
DS CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .