| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 702 7 FLOOR PANCHWATI PLAZA KUTCHERY ROAD RANCHI JHARKHAND 834001 | Admitted-Finance |
| 2 | Admitted-Finance 202 SHRILOK COMPLEX H B ROAD THARPAKHNA RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical NON RESPONSIVE |
| 4 | Rejected-Technical 4TH FLOOR SWETANJALI NIWAS HANUMAN MANDIR MARG KRISHNA PURI CHUTIA RANCHI JHARKHAND 834001 | RANCHI | RANCHI | JHARKHAND | 834001 | Rejected-Technical NON RESPONSIVE |
| 5 | Rejected-Technical | Rejected-Technical NON RESPONSIVE |
Tender Value
Refer Docs
EMD Value
₹14.3 L
Closing Date
30 Mar 2021, 5:00 pmClosed
Nodal Officer
e Procurement Cell,BCD,Jharkhand,Ranchi
Proposed Construction of CM Annexee Block at Project Bhawan Campus Dhurwa Ranchi
2021_BCD_48398_1
BCD/Special Works Division/04/2020-21
Open Tender
Civil Works - Buildings
365 days
Project Bhawan
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
EE,BCD,Special Works Division,Ranchi
₹14.3 L
14 Jun 2021
5 Mar 2021
1 Apr 2021
5 Mar 2021
30 Mar 2021
5 Mar 2021
Amount
EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
EXTRA FOR EARTH WORK IN hard soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Providing coarse clean SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing P.C.C. M-15 with nominal mix of (1:2:4) in FOUNDATION and plinth with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing taxes and royalty all complete as per building specification and direction of E/I.
Providing R.C.C. M-20 with nominal mix of (1:1.5:3) in FOUNDATION and plinth with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in COLUMN with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of Engineer Incharge.
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in BEAM with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of Engineer Incharge.
Providing R.C.C. M-20 with normal mix of 1:1.5:3 in ROOF SLAB with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in LINTEL BAND with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all comple as per building specificationand direction of E/I.
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in LINTEL with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all comple as per building specificationand direction of E/I.
Providing R.C.C M-200 with nominal mix(1:1.5:3) in stair case with approved quality of stone chips 20 mm to 6 mm size graded and clean course sand of FM 2.5 to 3 including screening, shuttering, mixing cement concrete in concrete mixer and placing in position , vibrating, striking, curing (but excluding the cost of reinforcement)royalty and taxes all complete job as per building specification and direction of E/I.
Providing 63 mm thick R.C.C. M-20 with nominal mix of 1:1.5:3 in CHAJJA with approved quality of stone chips 20 mm to 6 mm size graded 20 mm to 10 mm, 10 mm to 6 mm stone chips by volume(2:1) and clean coarse sand of F.M. 2.5 to 3 including making drip course mix in concrete in mixer, placing in position screening, vibrating, striking, and providing 6 mm cement plaster (1:4) in ceiling and sides of Chajja with making drip course curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of Engineer Incharge.
Providing 35 mm thick precast R.C.C. M- 20 with nominal mix of (1:1.5:3) shelves with approved quality of stone chips 12mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 with 1.5 mm cement punning at top and side and 6mm cement plaster (1:4) at bottom including screening , curing and placing the slab in position(but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I.
Providing 25 mm thick DAMP PROOF COURSE with cement concrete M-20 with nominal mix 1:1.5:3 with approved quality of stone ships of 20 mm to 6 mm (20mm to 10 mm : 10 mm to 6 mm stone chips 2:1) size graded and clean coarse sand of F.M. 2.5 to 3 including screening, mixing cement concrete in mixer with 5% Cico or any other approved water proofing compound and placing in position, striking, curing taxes and royalty and complete as per building specification and direction of E/I.
Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). as per building specification and direction of E/I
Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 12 mm thick water proof CEMENT PLASTER (1:6)on outside wall with clean coarse sand of F.M.1.5 and 5% cico/ waterproofing compound as specfied including cost of screening, curing making grooves with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I. (Cost of cico/ waterproofing compound will be paid separately)
Providing tuck pointing [1:3] in cement on brick work clean coarse sand of F.M 1.5 FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. as per building specification and direction of E/I
no. of bag per m3 = 28.80 bag
Providing 12mm cement plaster(1:3) with clean course sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm cement plaster(1:3) with clean course sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing Tor steel reinforcement of bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (ONLY VALID FOR SAIL & TATA STEEL, JSPL, ELECTRO STEEL LTD. AND VIZAG STEEL)
TOR 8 & 10 MMDIA. @ 45% of total steel qty.
TOR 12 -32 MM DIA. @ 55% of total steel qty.
Providing & fixing FAN HOOK of 16 mm dia M.S. bar, 1 M long bent to required size and shape, placed in position and fluid in the R.C.C. slab-beam at the time of casting all complete as per building specification and direction of E/I. (where material is no)
Supplying, fitting & fixing 250 x 20 x 6 mm L-type M.S. clamp properly fishtailed including making holes and setting the same in 375 x 125 x 75 mm cement concrete block (1:2:4) with cost of all layout and materials and taxes as per building specification and direction of E/I.
Making 20x6 mm grooves in plaster surface over walls trully horizontal or vertical as specified at regular intervals at all heights including cleaning finishing , scaffolding and curing with all leads and lifts of water all complete as per buildinng specification and direction of E/I.
Extra for R.C.C. work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
Extra for PLASTER ON OUTER SIDE work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
Providing and fixinging 20 mm thick mirror polished, machine cut for kitchen platform and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 (1cement :4 coarse sand) laid and jointed with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. as per building specification and direction of E/I
Extra for providing edge moulding to Granite stone counters, vanities etc. over above including machine polishing to edge to give high gloss finish etc. complete as per design approved by Architects / E/I.
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match themarble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Providing and laying DOUBLE CHARGE VITRIFIED FLOOR TILES in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08% and confirming to IS : 15622/ ISO 13006, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.30 kg per sqm including grouting the joints with white cement and matching pigments etc. complete. as per building specification and direction of E/I. SIZE OF TILE 600MMX600MM
Providing 25mm thick first class patent stone flooring ( 1:2:4 ) with stone chips, in two layers, bottom layer 19mm thick ( 1:2:4 ) with 12mm to 6mm, size graded stone chips and top layer 6mm thick ( 1:2 ) with 6mm down stone chips in panels, including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm cement plaster(1:3) with clean course sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. Approved Brand - Johnson/ Equivalent. as per building specification and direction of E/I
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : as per building specification and direction of E/I
Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and1.8 cm thick fixed in Urinal Partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement :2 coarse sand : 4 stone chips)as per direction of E/I and finished smooth. Granite Stone of Approved Shade
Supplying, fitting and fixing good quality well dressed and well seasoned sal wood work in chaukhat in doors window ,sky light, fanlight and celevitial window opening including wedge over clmps all including application of two coats of wood preservative of approved quality on the surface , building walls and lintel all complete as per building specification and direction of El.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. as per building specification and direction of E/I
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Approved Brand - Green Panel/ Century/ Green Ply.
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): as per building specification and direction of E/I. Rectangular or square
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : as per building specification and direction of E/I
Particle Board 12 mm thick
Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
Extra for providing lipping with 2nd class teak wood battens 25mm minimum depth on all edges of shutters (over all area of door shutter to be measured). as per building specification and direction of E/I
Providing and fixing stainless steel finish Brass hanging floor door stoppers ISI marked anodized (anodic coating not less than grade Ac 10 as per I.S. 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. (Approved Brand - DORSET, code - DSHT) as per building specification and direction of E/I
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately).
Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): as per building specification and direction of E/I
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.
The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. as per building specification and direction of E/I
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring (APPROVED BRAND) type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. as per building specification and direction of E/I
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.
1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”
2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.”
3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml”
4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm”
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site as per building specification and direction of E/I
6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” as per building specification and direction of E/I
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass (loee glass) of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. as per building specification and direction of E/I
Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roof terraces etc. consisting of following operations.
Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS : 2645 over the RCC slab including cleaning the surface before treatment.
Laying cement concrete using broken bricks/brick bats 25 mm to 100 mm size with 50% of cement mortar of mix 1:5 ( 1 cement : 5 coarse sand ) admixed with proprietary water proofing compund conforming to IS :2645 over 20 mm thick layer of cement mortar 1:5 (1 cement : 5 coarse sand ) admixed with proprietary water proofing compund conforming to IS :2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs
After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS: 2645.
Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand ) admixed with proprietary water proofing compund conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300X300 mm square.
The whole terrace so finished shall be flooded with water for minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the E/I.
With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. as per building specification and direction of E/I
(WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing 12mm cement plaster(1:3) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5 mm th. cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Providing applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth copmlete . as per building specification and direction of E/I
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. as per building specification and direction of E/I
Two coats
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. as per building specification and direction of E/I
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: as per building specification and direction of E/I
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete. as per building specification and direction of E/I
Finishing walls with textured exterior paint of required shade : as per building specification and direction of E/I
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm
Providing Primer one coat of read lead paint of approved make over new STEEL SURFACE preparing the surface after cleaning, removing rust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners, etc.)
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.
The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7),(Approved Brand- Armstrong/ Equivalent)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long,
the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recomme-nded jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm. as per building specification and direction of E/I
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. as per building specification and direction of E/I
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Making Soak Pit 2.5 m diameter 3.0 meter deep with 45x45cm dry briick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standerd design . as per building specification and direction of E/I. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
DT: Basic rates for 125/115 mm dia Drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH ring Machine all complete including supplying all meterial, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of engineer-in-charge. (Basic rates)
(i) Drilling up to 30 mtr. Depth below G.L. in Rural Area
Supplying, assembling, lowering and fixing in vertical position in borewell unplasticized PVC medium well screen (RMS) pipes with ribs, confirming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of engineer-in-charge.
100 mm nominal size dia. -
Supplying,filling, spreading and levelling stone boulders of of size range 5cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.
Supplying,filling, spreading and levelling gravels of size range, 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in the required thickness, for all leads and lifts, all complete as per direction of E/I.
Supplying fitting and fixing Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm (2'-0"x2'-0"*2) in position as per specification and direction of E/I.
CARRAIGE OF MATERIALS
COARSE SAND
STONE CHIPS
BRICKS
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast iron P or S trap, 10 litre low level white P.V.C. Flushing cistern with munally controlled device (handle lever) conforming to IS:7231 Parryware/ Hindware with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. as per building specification and direction of E/I
White Vitreous China Orissa pattern W C pan of size 580 X 440 mm with integral type foot rest.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled devicde (handle lever), conforming to IS:7231, parryware/Hindware/with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. as per building specification and direction of E/I
W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing C.P. brass bib cock of approved conforming to IS 8931 as per building specification and direction of E/I
15mm nominal bore (Approved Make- Jaquar/ Equivalent) C.P. fittings
Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 690gms. as per building specification and direction of E/I
15mm nominal bore (Approved Make- Jaquar/ Equivalent) C.P. fittings
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. as per building specification and direction of E/I
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: as per building specification and direction of E/I
White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china flat back half stall urinal of 580X380X350mm with white PVC automatic flushing cistern, parryware/Hindware with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass with waste fitting as per IS : 2566 P.V.C. trap with outlet grating and other couplings in C.P. brass including parenting of fitting and cutting and making good the walls and floors wherever required. as per building specification and direction of E/I
Single half stall urinals without 5 litre P.V.C. auotmatic flushing cistern, (Approved Make- Jaquar/ Equivalent)
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. as per building specification and direction of E/I
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. as per building specification and direction of E/I
Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 810gms. as per building specification and direction of E/I
15mm nominal bore (Approved Make- Jaquar/ Equivalent) C.P. fittings
Providing and fixing C.P. brass angle valve for basin mixer, gyser & others points of approved quality conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings. as per building specification and direction of E/I 15 mm nominal bore (Approved Make- Jaquar/ Equivalent)
Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. as per building specification and direction of E/I
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end ) as per building specification and direction of E/I
32MM nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. as per building specification and direction of E/I
25mm nominal bore
Providing and fixing 100mm dia. Steel Jali of approved quality. as per building specification and direction of E/I
Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required: as per building specification and direction of E/I
kitchen sink without drain board 610x510mm bowel depth 200mm
Providing and fixing C.P Sink cock with swinging casted spout with concealed fitting arrangements. as per building specification and direction of E/I
Providing and fixing unplasticised P.V.C. connection pipe with c.p. nuts collar and bush of approved qualityand colour. as per building specification and direction of E/I
15 mm nominal bore with 45 cm length.
Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete. as per building specification and direction of E/I
Flexible Pipe 32 mm dia
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (ITEM FOR RAIN WATER, SOIL, WASTE & VENT PIPES) as per building specification and direction of E/I
75 mm dia
110 mm dia
Providing & fixing on wall face unplasticised -P.V.C. moulde fittings / accessories for unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . as per building specification and direction of E/I
Coupler - 110 MM
Single pushfit Coupler -110 MM
Single tee with door- 110X110X110 MM
Single tee without door- 110X110X110 MM
Bend 87.5° -110 MM
SHOE- 110 MM
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I.(Approved Brand - ASTRAL/ SUPREME)
Concealed work including cutting chases and making good the wall etc..
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL/ SUPREME) Internal work - Exposed on wall
25mm dia.mm nominal outer dia Pipes
32 mm dia.mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. as per building specification and direction of E/I
150 MM dia R.C.C. pipe
250 MM dia R.C.C. pipe
Constructing brick masonary chamber for Underground C. I. Inspection Chamber and bend with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. Cover with frame (light duty) 455X610 mm internal dimensions, total weight of cover with frame to be not less than 38 KG. (weight of cover 23 kg. and weight of frame 15 kg) RCC top slab with 1:1.5:3 mix (1 cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 mix (1 cement:5 coarse sand :10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm th. with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: as per building specification and direction of E/I
Inside dimensions 455X610X mm and 45 mm deep for single pipe line. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Point wiring in PVC conduit, with modular type switch- Wiring for light point/fan point/exhaust fan point /call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit with moduler type switch,moduler plate,suitable size GI box etc. as required . as per building specification and direction of E/I. GROUP-C
Twin Control Point Wiring in PVC Conduit, with Modular Type Switch- Wiring for twin control light point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way moduler type switch,moduler plate,suitable size GI box etc. as required . as per building specification and direction of E/I
Power Plug Wiring in PVC Conduit (2X4 sq. mm)- Wiring for light/power plug with 2 x 4 sqmm. FR PVC insulated, copper conductor single core cable in surface / recessed PVC conduit along with 1 no 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required. as per building specification and direction of E/I
Circuit / Submain wiring in PVC conduit- Wiring for Circuit / submain wiring along with earth wire with the following size of PVC insulated, copper conductor single core cable in surface / recessed PVC conduit as required: as per building specification and direction of E/I
2x1.5 sq.mm.+1x 1.5 sq mm earth wire (for switch board )
2x2.5 sq.mm.+1x 2.5 sq. mm earth wire (for switch board )
4 x 6.0 sq.mm+2x6.0 sq.mm.earth wire (Sub-Mains)
4 x 10 sq.mm +2x10 sq.mm. earth wire (Sub-Mains)
4 x 16 sq. mm +2x16 sq.mm. earth wire (Sub-Mains)
Supplying and fixing light plug point with modular type accessories - Supplying and fixing suitable size GI box with moduler plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. moduler type switch, connections painting etc. as required. (For light plugs). as per building specification and direction of E/I
Supplying and fixing power plug point with piano type accessories- Supplying and fixing suitable size GI box with moduler plate cover in the front on surface or in recess including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps. moduler type switch, connections painting etc. as required. (For power plugs). as per building specification and direction of E/I
Supplying and fixing 'C' Series MCB- Supplying and fixing following 240 volts 'C' Series miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. as per building specification and direction of E/I
6/32 amps,single pole
6/32 amps.TPN
40 amps.TPN
50/63 amps. TPN
Supplying and fixing modular type switch/ socket-Supplying and fixing following moduler type switch / socket on the existing moduler plate & switch box including connection but excluding moduler plate etc. as required. as per building specification and direction of E/I
5/6 amps, one way switch
5/6 amps, 3 pin socket outlet
Supplying and fixing modular type electronic fan regulator- Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc, as required. as per building specification and direction of E/I
Supplying and fixing moduler type blanking plate- Supplying and fixing moduler blanking plate on the existing modular plate and switch box excluding modular plat as required. as per building specification and direction of E/I
Supplying and fixing Dingdong call bell- Supplying and fixing Dingdong call bell suitable for D.C/A.C single phase, 230 volts, complete as required. as per building specification and direction of E/I
Supplying and fixing T.P. MCB DB- Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts,on surface /recess, complete with tinned copper bushbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (but without MCB/RCCB/ISOLATOR) as per building specification and direction of E/I
4 way(4+12)double door HORIZONTAL TYPE
6 way (4+18)double door HORIZONTAL TYPE
8 way (4+24)double door HORIZONTAL TYPE
Supplying and drawing UTP 4 pair CAT 6 LAN cable in the existing surfface/recessed steel / pvc conduit as required. as per building specification and direction of E/I
1 run of cable
2 run of cable
3 run of cable
Wiring in existing conduit- Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel /PVC conduit as required. as per building specification and direction of E/I
2x1.5 sq mm
Supplying and fixing PVC Conduit- Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required .as per building specification and direction of E/I
20 mm PVC coduit.
25 mm PVC coduit.
GI Earth pipe eletrode with salt / charcoal- Earthing with GI earth pipe 4.5 m long 40 mm dia. including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc, with charcoal and salt as required. as per building specification and direction of E/I
Copper Earth Plate Electrode- Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. (but without charcoal or coke and salt) as per building specification and direction of E/I
Salt / Charcoal for plate earth electrode- Extra for using charcoal and salt for GI/Copper Plate earth electrode as required. as per building specification and direction of E/I
Providing and fixing 25mm X 5mm GI earth strip in surface / recess- Providing and fixing 25mm x 5mm GI strip on surface or in recess for connection etc as required. as per building specification and direction of E/I
MV Cable Laying up to 400 sq. mm in ground- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade. of size exceeding 120 sq mm but not exceeding 400 sq mm Direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. as per building specification and direction of E/I
Supplying and Making Cable Route Marker with cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size ) of size 60 cm. X 60cm. at the bottom and 50mm x 50mm at the top with a thikness of 10cm. including inscription duly engraved as required. as per building specification and direction of E/I
Supply of ISI marked (IS : 7098 Pt-I) aluminium conductor XLPE Insulated armoured, served, sheathed cable 1100 volts grade. (Skytone, Rallison, CCI, Gloster make) as per building specification and direction of E/I
150 sq mm, 3.5 core
70 sq mm, 3.5 core
MAIN DISTRIBUTION BOARDS / L.T. PANEL.
LT PANEL (NORMAL SUPPLY) :25 KA) -INCOMING (1- sets G.F) each with following:
200 Amp, MCCB FP -2 no, Ammeter, ASS, CTs, Voltmeter, VSS, Fuses, Frequency Meter, 2 Sets of Phase Indicating Lights with fuses & following accessories: - 1 set,200A changover FP (ON-LOAD)-1nos.
BUS BARS
1 sets of 300 Amp, 415V, 3 phase, 50 Hz TPN copper bus bars.
OUTGOING
a)6 Nos of 40 Amp TPN MCB,
b)6 Nos of 63 Amp TPN MCB,
c)01 Nos of 125 Amp FP MCCB,
LT Panel (Normal) as above
200amps, 35 ka, fixed thermal setting
40 amps.TPN
50/63 amps. TPN
200amps, 4 pole
VOLT METER (0-500 volt) -3 phase class 0.5
AMP mtr. (0- 500 amp) -3 phase class 0.5
1.5 sq.mm ISI Marked, FR Ms PVC Insulated, single core copper counductor cable.
6.0 sq.mm ISI Marked, FR Ms PVC Insulated, single core copper counductor cable.
10 sq.mm ISI Marked, FR Ms PVC Insulated, single core copper counductor cable.
25sq.mm ISI Marked, FR Ms PVC Insulated, single core copper counductor cable.
LT PANEL (NORMAL SUPPLY) :25 KA) -INCOMING (1- sets F.F) each with following:
160 Amp, MCCB FP -01no, Ammeter, ASS, CTs, Voltmeter, VSS, Fuses, 1 Sets of Phase Indicating Lights with fuses & following accessories: - as per building specification and direction of E/I
BUS BARS
1 sets of 200 Amp, 415V, 3 phase, 50 Hz TPN copper bus bars.
OUTGOING
a)7 Nos of 40 Amp TPN MCB,
b)7Nos of 63 Amp TPN MCB,
LT Panel (Normal) as above
160amps, 16 ka, fixed thermal setting
1x28watt T5 Tube light fitting as per building specification and direction of E/I (Make - Havells/ Philips/ Bajaj)
Recess Mounting LED Round Down Light (18/20w) Make - Havells/ Philips/ Bajaj. as per building specification and direction of E/I
Decorative Ceiling fans, 1200mm dia sweep. as per building specification and direction of E/I Make - Havells/ Philips/ Bajaj.
9'' (230mm) Metal Exaust Fan. as per building specification and direction of E/I . Make - Havells/ Philips/ Bajaj.
12'' (300mm) Metal Exaust Fan. as per building specification and direction of E/I . Make - Havells/ Philips/ Bajaj.
ITC fluorescent fitting directly on surface- Installation, testing and commissioning of prewired, fluorescent fittings, compact fluorescent fitting of all types complete with all accessories and tubes etc. directly on ceiling / wall, including connections with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc as required as per building specification and direction of E/I
ITC Ceiling fan- Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required. as per building specification and direction of E/I
ITC Exhaust fan up to 450mm. sweep- Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required. as per building specification and direction of E/I
Erection on incandescent light fitting- Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto 2 GLS amps per fitting ,complete with all accessories including connection etc as required. as per building specification and direction of E/I
Supplying, installation, testing and commissioning ofbelectric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered (900 lpm at 35 m Head) as per building specification and direction of E/I
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required as per building specification and direction of E/I :
80 mm diameter
100 mm diameter
150 mm diameter
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : as per building specification and direction of E/I
80 mm diameter
100 mm diameter
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. as required. as per building specification and direction of E/I
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required as required or as directed by engineer incharge. Make:Tata/Nezone/Jindal
150 mm diameter
100 mm diameter
80 mm diameter
65 mm diameter
50 mm diameter
40 mm diameter
25 mm diameter
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : as per building specification and direction of E/I
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.. as per building specification and direction of E/I. 40 m
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :. as per building specification and direction of E/I. Gun Metal
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : as per building specification and direction of E/I. Gun metal
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :. Make:Safex/Atasee/Tyco as per building specification and direction of E/I. Concealed sprinkler
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPTfemale thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.. as per building specification and direction of E/I. 1500mm
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :. as per building specification and direction of E/I. 4 way - 150 mm dia M.S. Pipe
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.. as per building specification and direction of E/IMake:Tyco/Honeywell/Seimens/Bosch
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.. as per building specification and direction of E/I Make:Tyco/Honeywell/Seimens/ Qutak/ Bosch
Supplying, installation, testing & commissioning of addressable manual call point complete as required.. as per building specification and direction of E/I Make:Tyco/Honeywell/Seimens/Qutak/Bosch
PART - II NON - SCHEDULED ITEMS ONLY
Providing & ejecting Chemical emulsion for pre-constructional ANTI TERMITE TREATMENT and creating a chemical barrier under a alround the column pits, wall trenches, basement excavation, top surface of plinth filling junction of wall and floor along the external perimeter of building expansion joints, surrounding of pipes and conducts tic. complete(plinth area of the building at ground floor only shall be measured) with Chlorpyrifos 20% EC as per building specification and direction of E/I. (4 stages treatment)
Providing and laying SPECIAL TYPE OF VITRIFIED FLOOR TILES NEXION TILES, PULPIS GRIGIO (FULL LAPATO/ LAPATO MATT) (thickness to be specified by manufacturer), in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.30 kg per sqm including grouting the joints with white cement and matching pigments etc. complete. as per building specification and direction of E/I SIZE OF TILE- 600MMX1200MM
Providing and laying SPECIAL TYPE OF VITRIFIED FLOOR TILES NEXION TILES, BIANCO LASA (LAPATO MATT) (thickness to be specified by manufacturer), in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.30 kg per sqm including grouting the joints with white cement and matching pigments etc. complete. SIZE OF TILE- 600MMX1200MM
Providing and laying SPECIAL TYPE OF VITRIFIED FLOOR TILES, NEXION TILES, ONICE PERSIANO FULL LAPATO/ LAPATO MATT) (thickness to be specified by manufacturer), in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.30 kg per sqm including grouting the joints with white cement and matching pigments etc. complete. SIZE OF TILE- 600MMX1200MM
Providing and laying SPECIAL TYPE OF VITRIFIED FLOOR TILES, NEXION TILES, RUNA BEIGE (thickness to be specified by manufacturer), in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.30 kg per sqm including grouting the joints with white cement and matching pigments etc. complete. as per building specification and direction of E/I SIZE OF TILE- 800MMX1600MM
Providing and Fixing 8.3mm th. Laminated AC 4 Grade wooden flooring over existing floor including all profile, etc. all complete.as per building specification and direction of E/I make (green panel/ estiontesa)
Providing and fixing 4mm th. natural teakwood (Mahogany/ equivalent) veneer including pasting on board with Fevicol/ equivalent including all taxes complete. Approved brand - Green panel naturemax/ Equivalent. as per building specification and direction of E/I
Providing and fixing bright finished brass 100 mm mortise latch with one dead bolt (Coin & knob) and a pair of lever handles of approved quality with necessary screws etc. complete. as per building specification and direction of E/I (Make - DORSET/ DORMA)
(Approved Brand - DORSET, code for 70mm cyllinder CL 208 & Handle - HLBAAPT)
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. as per building specification and direction of E/I
(Approved Brand - DORMA / DORSET, code for 70mm cyllinder CL 207 & Handle - HLBAAPT)
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with Pelmet arm (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. as per building specification and direction of E/I (Approved Brand - DORMA / DORSET, code - DC80EXTWP)
IN DOORS
Providing and fixing top and bottom Patch for frameless toughened glass door shutter including all screws, etc. all complete. as per building specification and direction of E/I APPROVED BRAND - DORMA / DORSET, CODE - DPF 320, 321& 322
Providing and fixing lock with cylinder for frameless toughened glass door shutter including all screws, etc. all complete. as per building specification and direction of E/I APPROVED BRAND - DORMA / DORSET, CODE - DPF 325
Providing and fixing Door Handle for frameless toughened glass door shutter including all screws, etc. all complete. as per building specification and direction of E/I APPROVED BRAND -DORMA/ DORSET, CODE - SH36PSS
Providing water proofing treatment in Retaining wall, Basement floor slab O. H. Tank with following application including all materials, labours, taxes complete, as per follwing applications. -
After the release of shuttering, repair all bug or pin hole with polymer modified mortar on the exterior surface of underground retaining wall.
Make a 20X20 groove along with the construction joint and seal the same with polymer modified mortar , specially the starter joint of the retaining wall.
Prior to apply Sika Top Seal 107 the surface should be made SSD
Apply first coat of Sika Top Seal 107 over prepared surface. Coating should be continued over the projected portion of the rft and also 300mm above from the G.L allow the coated surface air cure for at least 4 hrs
Before application of 2nd coat , surface should be wet again with the help of sprinkling water Apply second coat of Sika Top Seal 107 over the executed first coat
The coating shall be covered with 12 mm thick plaster added with waterproofing admixture Plastocrete Super 0.2% by weigh of cement with a cement – sand (1:4)
Drill hole up to half of the depth of the concrete and fix nozzles of 12 mm dia GI / NBMS nozzle 1m c/c in a grid pattern in the interior surface of retaining wall with the help of quick setting compound Sika 2. as per building specification and direction of E/I
(WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Mellamine polishing with spray :
Two or more coats on new works including a coat of wood filler as per building specification and direction of E/I
Providimg and fixing 10 mm th. Toughened glass with all fittings and fixtures over 16G and 304 Grade stainless steel railing and 40mm sq. Balusters, all complete, As per detail drawing and design. as per building specification and direction of E/I
Providing and fixing Zebra Blind (VISTA LEVELLOR) over window opening including all fittings and labour, complete job. As per building specification and direction of E/I
Providing and fixing of Vinyl Wall paper on wall with with proper adhessive with all taxes etc. Complete. as per building specification and direction of E/I(Make - D'décor/ Nilaya (Asian Paints) As per building specification and direction of E/I
Providing 3 mm th.Stonelam tile (Beia series) cladding over wall with chemical pasting including all taxes all complete job. As per building specification and direction of E/I
Providing and Fixing Armstrong Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm or as required by the Architect/ approving engineer, made of a Moisture Resistant fibre board with minimum 595 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 13mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.59. The panels shall be mounted on special aluminium splines (keel) using clips provided by Armstrong and approved As per building specification and direction of E/I
INSTALLATION: Install wooden battens (provided by others) of section 50x50mm or as approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to centre. Screw the aluminium extruded keel for channelled woodworks provided by Armstrong over the lowest and second wooden batten at an on-centre distance of 600mm. Install the Skirting (provided by others) of width 50mm or more as required by the Architect/ Engineer-in-Charge and insert the tongue end of the panel in the skirting. Place the inside clip on the groove end of the panel along the Al keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. Finish off the edges using wooden moulding of matching colour (provided by others). Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure.
Providing Armstrong Optra accoustical wall panelling/ fabric wrapped.
Providing and supplying Armstrong ‘Optra Acoustical Wall Paneling’ with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A as per ASTM E-84, fabric with an option of colors – Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut & Shell as per the choice of the Architect of size 600X600 mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel impalers supplied by M/s Armstrong Industries India Pvt. Ltd and construction adhesives as per the instructions laid down by the manufacturer.
INSTALLATION: 4nos. Armstrong wall panel Impalers of shall be fixed to the wall surface using self-tapping screws. Silica based construction adhesive to be dabbed on to the projecting elements (spikes) of the impalers. Armstrong Optra wall panels shall be pierced through the spikes of the impalers ensuring the line and level of the panels are maintained. Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure. As per building specification and direction of E/I
Providing & Fixing of Armstrong Wooden finished Suspended Ceiling System with Woodworks Microlook edge tiles with Armstrong 15mm Silhouette B/R exposed grid. The Tile in RG3003 (RG3) perforations with approved laminate (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut) finish would have an NRC of 0.42, Humidity Resistance (RH) of 70% in module size of 600mm x 600mm x 18mm and density of 725 Kgs/M3. The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/M2. Silhouette, Main Runners & Cross Tees to have mitred ends & “birds mouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 120 grams per M2 & passed through 500 hrs of Salt test.
INSTALLATION: To comprise main runner spaced at 1200mm centers securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centers. As per building specification and direction of E/I
METALWORKS ALUMINIUM 600mm X 1200mm (MICRO LOOK) EDGE TILES WITH ARMSTRONG XL 15 mm SILHOUETTE EXPOSED GRID” SYSTEM Providing & Fixing of Armstrong ALUMINUM Lay in Plain metal ceiling consisting of 600x1200mm Lay in tiles in 0.7 mm thick Aluminum post coated to Global white color to be laid on Armstrong grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm & 600 mm Cross Tees. The tiles would have Fire Performance of Class A2-s1.d0 as per EN13501 standard in module size of 600 X 1200mm, suitable for Green Building application, with Recycled content of 50%. The Tile & Grid system used together should carry a 10 year warrantee. The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm and a load carrying capacity of minimum 15.68 Kgs/M2. Silhouette, Main Runners & Cross Tees to have mitred ends & “birds mouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 120 grams per M2 & passed through 500 hrs of Salt test.
INSTALLATION: To comprise main runner spaced at 1200mm centers securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centers. as per building specification and direction of E/I
OPTRA WHITE 600X1200MM MICROLOOK WITH SILHOUETTE PROFILE GRIDS Providing & Fixing of Armstrong Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles With Armstrong 15mmExposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ≥85%, , Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 1200 x 20mm , suitable for Green Building application, with Recycled content of 66% GW & 74% RW. The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm. Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions and a load carrying capacity of 14.29Kgs/M2 with a minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make
INSTALLATION:To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres. Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure. As per building specification and direction of E/I
Providing & fixing of 6 mm thick Exterior Grade High Pressure Laminates of Royale Touche make, complete fabrication with 63.5 mm x 38 mm x 1.8 mm thick colour anodized aluminium extruded section vertical member fixing on the wall structure by M.S. bracket (duly fastening) & nuts, bolts. Laminates fixing of Main frame structure with colour Rivets & other necessary hardware as per approved drawing & colour shades details as here under: The Rattes are inclusive of all scaffolding. as per building specification and direction of E/I (Approved Brand - Century/ Royale Touch/ Timex).
Structural Specification with fittings:
Vertical Member : 63.5 mm X 38 mm X 1.8 mm/ 38 mmx38 mm X 1.8 mm
Bracket (M.S.) : 50 mm X 50 mm X 5 mm
Fasteners : Fisher / Hilti / Anchor etc
Nuts & Bolts : 10 mm X 125 mm
High Pressure Laminates : 6 mm thick Royale Touche make
Screw & other necessary
Hardware fittings : As per standard specification. as per building specification and direction of E/I
Providing and fixing of Skylight- pyramid with structural steel – RHS 150 x100x5mm thick , steel base plates – 12mm thick with primer, Welfast- M10x100, PU paint , aluminum flat 50 x 5mm thick , 3M SGT tape, self tape screw with 13.52 mm milky pvb laminated ( 6mm Clear Reflective + 1.52 PVB + 6mm clear ) glass all complete. as per building specification and direction of E/I
Providing and fixing white vitreous china extended wall mounting water closet of approved size, shape and design including concealed flushing cistern with follwing fittings, all compete with accessories, screws, etc. as per building specification and direction of E/I
Wall Hung WC with UF soft close slim seat cover, Hinges, as per building specification and direction of E/I Accessories set - CAT. NO. - JAQUAR, KUS-WHT- 35953BIUFSM (Make - JAQUAR / KOHLER)
Single piece slim concealed cistern with wall mounting frame, installation kit and P-type drain pipe as per building specification and direction of E/I connection set (without flush control plate. CAT. NO. - JAQUAR, JSA - WHT-2400 WP (Make - JAQUAR / KOHLER)
Control Plate Kubix. CAT. NO. - JAQUAR, JCP-CHR-352415 (Make - JAQUAR / KOHLER)
Pair of Rack Bolt for W.C. CAT. NO. - JAQUAR, ZPS-SNS- RB07
Providing and fixing C.P Soap Dish of with concealed fittings, complete job. as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
CAT. NO. - JAQUAR, AQN - 1300
Providing and fixing Soap Dispenser with with glass bottle. as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
CAT. NO. - JAQUAR, AKP - 35735P
Providing and fixing Wash basin with all accessories, 15mm C.P. pillar cock 32mm C.P brass waste of cutting and making good the wtherever require all complete. as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
TABLE TOP BASIN - CAT. NO. - JAQUAR, KUS - WHT - 35935, SIZE - 565X420X140M
SINGLE LEVER BASIN MIXER WITHOUT POPUP WASTE WITH 450 MM LONG BRADED HOSES
BOTTLE TRAP - CAT. NO. - JAQUAR, ALD - 769L - 300X190
WASTE COUPLING - CAT. NO. - JAQUAR, ALD - 709
Providing and fixing follwing items for shower with all concealed fittings including cutting and making good the wall, all complete. as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
4 WAY DIVERTER, Concealed Body for single Lever Diverter 40mm cartridge with button assembly, cartridge sleeve (button on top) But without exposed part - CAT. NO. - JAQUAR, ALD-065. as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
SINGLE LEVER EXPOSED PARTS kit of Diverter consisting of operating lever, wall flange (with seals) & button only - CAT. NO. - JAQUAR, KUP- 35065 PM as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
OVERHEAD SHOWER 200X200mm Square shape single flow (ABS Body chrome plated with gray face plate with Rubit cleaning system - CAT. NO. - JAQUAR, OHS - 35497. as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
SHOWER ARM casted 600x25x25mm square shape wall mounted showers with ss flange - CAT. NO. - JAQUAR, SHA - 455L600. as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
BATH SPOUT with wall flange - CAT. NO. - JAQUAR, SPJ - 35429PM as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
Providing and fixing 6 mm th. beveled edge mirror of superior glass (of approved quality, Modiguard/ equivalent) over 12mm thick of plyboard of isi brand (green/ equivalent) complete with with C.P. brass screws and washers complete. as per building specification and direction of E/I
Nahani Trap
Multitrap
Providing and fixing C.P. brass Health Faucet with 8mm dia. 1.20m long flexible tube & wall hook. as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
Hand Shower - CAT. NO. - JAQUAR, ALD - 573
Providing and fixing C.P. Towel Rack 24" long as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
Towel Rail - CAT. NO. - JAQUAR, AKP - 35781PS.
Providing and fixing C.P. Towel Ring as per building specification and direction of E/I (Make - JAQUAR / KOHLER)
Towel Rail - CAT. NO. - JAQUAR, AQN - 7721
Supply and Fixing of following sockets including box of required size, grid face plate complete:
1 No x RJ45 Jack Outlet with box & face plate
INDICATOR LAMP
200/5 CT Coil
CRCA ENCLOSURE 16SWG
Panel commissioning / testing Charge
INDICATOR LAMP
CRCA ENCLOSURE 16SWG
Panel commissioning / testing Charge
Providing and fixing of primium type schandelier Light fitting with remote control (as per architect / consultant advice )complete Set (for Entrance Hall) as per building specification and direction of E/I
Supplying and fixing 10W LED Bulkhead light (make-BAJAJ / JAQUAR-code-LBLK01X0XC complete set.(for boundary wall) as per building specification and direction of E/I
Supplying & fitting of LED strip light with driver(Havells . AZURE LED STRIP -18W 3000K) as per building specification and direction of E/I (Make - Havells/ Philips/ Bajaj.)
Supplying of 7w COB fittings( Phillips COB Pro)complete set. as per building specification and direction of E/I (Make - Havells/ Philips/ Bajaj.)
Supplying of 10.5w Hue smart LED downlight fittings( Phillips Garnea )complete set. as per building specification and direction of E/I (Make - Havells/ Philips/ Bajaj.)
Supplying and fixing of Hue smart dimmer switch suitable to operate opto 12 hue light, wireless connection,range 20 mtr. as per building specification and direction of E/I
Providing and fixing of primium type LED wall Light fitting (as per architect / consultant advice )complete Set as per building specification and direction of E/I
Fabrication, Supplying, Installation, Testing & Commissioning of electrical control panel of cubical construction, wall mounted type, fabricated out of 2mm. thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection, and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respects, suitable for operation on 415 V, 3 phase 50 HZ AC supply with enclosure protection class IP 42. as per building specification and direction of E/I
Supply and fixing of PVC sheathed following conductor 1.1 KV grade armoured Cable of following sizes including making end termination with compression gland & bimetalic lugs, and support etc.complete as required as per building specification and direction of E/I
3 × 10 sq.mm.(aluminium)
Pressure Gauge Assemble with Gate/Ball Valve
Air release Valve
Providing and fixing 25 mm nominal gun metal gate valve class I with CI wheel of approved quality with union (Screwed end) as per building specification and direction of E/I
Supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick M.S. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect. as per building specification and direction of E/I
Providing , fixing Dry Chemical Powder (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 20oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (4 Kg Capacity) as per building specification and direction of E/I
Carbon Di-oxide Type , Gas Confirming to IS ‘15222’ , Cylinder Confirming to ‘IS 7285’ & PESO approved ,Controllable Discharge Mechanism, Discharge Hose & Horn As per ‘IS 15683’ & ‘IS 2878’ ISI mark Fire Extinguishers (Wheel Type or Squeeze Grip Type). Operating Temperature :- (-)20oC to (+)55oC Suitable for ‘B’ ‘C’ Class of FIRE (3 Kg Capacity) as per building specification and direction of E/I
Providing , fixing Modular type Fire Extinguishers for electrical rooms (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 10oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (5 Kg Capacity) as per building specification and direction of E/I
Providing and laying 19mm dia PVC conduit complete with required junction boxes in recessed / surface system PVC insulated copper conductor cable of 2x1.5 sq.mm. in existing conduit as required. Make:Polycab/Mescab as per building specification and direction of E/I
Supplying, Installation, Testing and Commissioning of 15 KVA Solar Power Plant with 15 KVA/240V solar offgrid invertor and 150 Ah 12V Solar Tubular Battery 20 Nos, Single Phase 15 Kva/ 240V Solar Invertor, MPPT based charge controller inbuilt, 44 Nos. Solar panel of 335 watt mounting over M.S. structure, Lightening Arrestor, Earthing Rod with accessories (complete setup of approved standard make) MC4 Connector, ACDB, DCDB, Cables to connect all batteries, solar and inverter etc. including all required accessories and fittings all complete job including warranty on site 25 years on Solar Panel, 5 years warranty on Battery & 2 years warranty on solar inverter. (Make for Battery, Solar panel and Inverter – UTL/ Equivalent), Approved Manufacturer – Sunson/ Fourth Partner. as per building specification and direction of E/I
Providing and Installing, Testing & Commissioning of 10 Passenger automatic Machine room less (MRL) Lift - 1no., including one year free maintenance which will be start from handing over the lift, all taxes and all complete as per following detail specifications. APPROVED BRAND - OTIS / SCHINDLER As per building specification and direction of E/I
PRODUCT- GeN2-Nova MRL
DETAILS - GeN2-Nova_MRL-1MPS
CAPACITY (kgs) - 680 Kg, 10 persons.
SPEED (mps) - 1 mps
RISE (m) - 4.5 m
STOPS-2 Stops With (all opening on the same side)
CONTROLLER TYPE- ACD3-MRL
DRIVE - VF Regenerative (Closed Loop)
POWER SUPPLY - 400/415 Volts (3 Phase AC)
OPERATION - Full collective operation
CAR GROUP - One car (simplex)
MACHINE - PM Gearless (Located in shaft on top of guide rails)
TRACTION MEDIA - Flat Coated Steel Belt
CAR FINISH- • Rear Mid Panel = Stainless Steel #4(Hairline) • Rear Corner Panels = Stainless Steel #4(Hairline) • Side Mid Panels = Stainless Steel #4(Hairline) • Side Corner Panels = Stainless Steel #4(Hairline) • Front Panels = Stainless Steel #4(Hairline)
FALSE CEILING TYPE- CD-41
FLASE CEILING FINISH-Stainless Steel #4(Hairline)
VENTILLATION - Cross flow fan
HAND RAILS - Stainless Steel Mirror Finish Handrails on rear car panels
FLOORING - GRANITE provided by customer . ( 20mm recess by OTIS)
CAR DOOR FINISH - Stainless Steel #4(Hairline) with vision panel
LANDING DOORS FINISH - Stainless Steel #4(Hairline) with vision panel
PIT DEPTH - 1350
OVERHEAD - 5000
HOISTWAY DIMENSIONS (W x D – mm) - 1800 mm W x 1950 mm D
CAR DIMENSIONS (W x D x H - mm) - 1100 mm W x 1600 mm D x 2200 mm H
CAR & HOISTWAY DOOR TYPE- Central opening (CO) doors
DOOR OPENING (W x H - mm) - 800 mm W x 2000 mm H
DOOR OPERATOR - DC Door Operator
COP - COP for stops <= 12 (950mm) in Stainless Steel #4(Hairline)
CAR POSITION INDICATOR - Monochrome LCD-Blue Background & White font Dot matrix (LED) Scrolling Display
HALL FIXTURES - O2000 Pan Type Fixture
HALL FIXTURE FACE PLATE - Stainless Steel #4(Hairline)
HALL BUTTON ARRANGEMENT - . LCD Monochrome type
STANDARD FEATURES - Anti-nuisance Car Call Protection Independent Service (for Duplex only) Overload Device Nudging Emergency Firemen’s Service Emergency Car Light Unit Infrared Curtain Door Protection Door Time Protection Emergency Alarm Button Extra Door Time of Lobby & Parking Door Open/Close Button Manual Rescue Operation Belt Inspection Drive Auto Fan Cut Off
OPTIONS INCLUDED - Automatic Rescue operation
Providing and fixing of 2" Screen Filter having fine mess including the bypass assembly including taxes and freight.as per building specification and direction of E/I
Providing and fixing of Self Priming Recirculating high capacity pump of CI Body and Steel Shaft & Impeller, 1.5 HP / single phase. (1 Working and 1 Standby.) Including taxes and freight. as per building specification and direction of E/I
Providing and fixing of ABS multiflow water diffuser nozzle 2" including taxes and freight. as per building specification and direction of E/I
Providing and fixing of 10 Kg/Cm² uPVC Pipes (ASTRAL/ SUPREME) and Fittings (Bend/Tee/Reducer Bush/End Caps/Solvent) including all required accessories (Pressure Gauge/Bypass Assembly), pump & backwash headers, valves, butterfly valves, non return valves, air release valves, pressure release valve, etc including taxes and freight. as per building specification and direction of E/I
Providing and fixing of SS316 LED Light 9W/24V Warm White, including taxes and freight. as per building specification and direction of E/I
Providing and fixing of transformers including taxes and freight. as per building specification and direction of E/I
Providing and fixing of Junction Box including taxes and freight. as per building specification and direction of E/I
Providing and fixing of electrical wire 2 core including taxes and freight. as per building specification and direction of E/I
Providing and fixing of Control Panel for pumps & lights unit complete in all respect including taxes and freight. as per building specification and direction of E/I
Providing and Application of Waterproofing of entire vertical wall and balancing tank area using 2 component acrylic coating in 2 coats @ 500 gms/sqm/coat after proper brushing, crack treatment, fixing weep & bore packing using cement mortar with latex and injection grouting with 40 PSI injection pump, cement & non shrink admixture in required ration. Pre and post waterproofing curing to did as per the manufacturer guidelines, including wastage, taxes and freight. As per building specification and direction of E/I
Providing and application of GRC brick rock Pattern undulated surface tiles using cement mortar for the elevation of the trickling water wall including wastage, taxes and freight. as per building specification and direction of E/I
Providing and application of 4x4 cm porcelain mosaic tiles using tile adhesive for the water body/balancing tank including wastage, taxes and freight. As per building specification and direction of E/I
Providing and application of natural vertical green wall system consists of light weight organic growth media, planting modules, drip irrigation system, hanging aluminum strips, acclimatized plants of different indoor verities on both sides of the trickling water wall, approx 10% extra buffer modules for maintenance, etc including taxes and transportation. as per building specification and direction of E/I
Providing and application of iron framework for natural vertical green wall system including priming & painting, taxes and transportation. as per building specification and direction of E/I
Providing and fixing of border work using Natural Pine 125mm wide x 18 mm thick planks around the green wall edges complete with fittings and accessories including wastage, taxes and freight. As per building specification and direction of E/I
1. Suppying, Installing, Testing and Commissioning of Network Video Recorder 32 CHANNEL DS7732NI -K4 HIKVISION, LOCATION - SECURITY CONTROL ROOM As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of NVR 16 CHANNEL DS7716NI -K4 HIKVISION LOCATION OF DEVICE -SECURITY CONTROL. As per building specification and direction of E/I ROOM
Suppying, Installing, Testing and Commissioning of IP VF BULLET 1L/4MP WDR CAMERA H.265+ IP-CCTV VF(make-Hikvision)-internet protocol vari-focal Camera Location -G. Fir-coridoors ,lobbies,entrance,halls,varandas,etc As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of IP VF DOME 1L/4MP WDR CAMERA H.265+HIK MAKE-HIKVISION,IP-VARIFOCAL DOME CAMERA As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of POE 24 PORT SWITCH DS3E0526P-E/M HIKV POE -power on ethernet ,location -suitable places /security As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of POE 16 PORT NETWORK GBYTE SWITCH HIKVI As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of IP NETWORK 5” IRPTZ /4MP/25XH.265+HIKV As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of IP NETWORK 4” IRPTZ /4MP/25XH.265+HIKV As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of HDD 6TB SATA SEAGATE SV SEAHAWK Location -control room nvr for storage SV-HDD-Surveillance hard disk drive ,capacity -6tb, Seagate As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of HDD 4TB SATA SEAGATE SV SEAHAWK As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of PTZ MOUNTING BRACKET WITH ACCESSORIES As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of MONITOR SMART FHD RESOLUTION CCTV 32” Location -security control room, resolution 1080p, display monitor As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of CAT6 NETWORK CABLE 305M POLYCAB/DLINK As per building specification and direction of E/I
SUPPLY & CABLE LAYING WITH CAT6 IP -CCTV PER MTR As per building specification and direction of E/I
Suppying, Installing, Testing and Commissioning of 9 U RACK WALL MOUNT D-LINK As per building specification and direction of E/I
5 KLD BURRIED STP WITH TERTIARY TREATMENT PLANT (TTP) BASED ON SEQUENTIAL BATCH REACTOR (SBR) PROCESS WITH FOLLOWING ITEMS WITH APPROVED DETAIL DWG. ALL COMPLETE A s per building specification and direction of E/I
Supply, installation, testing & commissioning of Bar Sceen, MOC- MSEP - To arrest the flotables from entering into the bio logical reactors. As per building specification and direction of E/I. (2 NO.)
Supply, Installation , testing & commisioning of Rotary type twin Lobe Air blower; provided for aeration inside reaction tank, for lifting the sewage from Buffer tank to reaction tank, reaction tank to CCT & lifting of sludge from reaction tank to primary tank. Make and specification of Blowers is as follows:- Make- Akash/AIRVAC/equiv., Capacity- 20 m3/hr @ 4000 mmwc As per building specification and direction of E/I. (2 NO.)
Supply, installation, testing and commissioning of Fine Bubble EPDM PTFE Coated Disc Diffuser Disc-350 EPDM (12’’- OD ) with all pipe fittings & valves. As per building specification and direction of E/I. (1 NO. COMPLETE SET)
Supply, installation, testing and commissioning of Hypo Dosing Pump with a operating capacity of 0-6 LPH @ 4.0 Kg/cm2., MAKE - E-Dose/Equiv. As per building specification and direction of E/I. (1 No. )
Supplying, installing, testing & commissioning of Hypo Dosing Tank with 100 Litres capacity HDPE tank with inlet / outlet connection, piping & valves. As per building specification and direction of E/I. (1 No. )
Supply, installation, testing and commissioning of MSFRP Tanks consisting of Pretreatment Tank,Buffer Tank & Reactor Tank for the STP Tank 1: 2 m Dia X 2.6 m LOS As per building specification and direction of E/I . (1 NO. COMPLETE SET)
Supplying, installing, testing & commissioning of Chlorine Contact Tank with 2 KL capacity HDPE tank with inlet / outlet connection, piping & valves. As per building specification and direction of E/I. (1 No. )
Supply, installation, testing & commissioning of Filter Feed Pump having CI casing and CI Impeller for feeding the water from chlorine contact/filter feed tank to tertiary tratment plant . Pumps shall have following duty: (Make: Kirloskar, CNP/Equivalent) appropriate flow. Flow- 0.75-1 m3/hr@30mwc (1 Working + 1 Standby) As per building specification and direction of E/I. (2 No. )
Dual Media Filter (Dia - 200 mm FRP Vessels)consisting of Anthracite, Sand, Pebbles & Gravels for removing total suspended solid and polishing of the treated water. As per building specification and direction of E/I. (1 No. )
Activated Carbon Filter (Dia - 200 mm FRP Vessels) consisting of Activated Carbon for removing odour,colour and polishing of the treated water. As per building specification and direction of E/I. (1 No. )
Supply Installation Testing and Commissioning of PVC Modules for Air Lift Technology for the purpose of Feeding, Decanting and Desludging of the sewage/sludge MOC: PVC As per building specification and direction of E/I. (1 Lot. )
Providing and laying of Interconnecting pipes and valves for sewage and sludge line of the entire system within battery limit as per requirement. MOC- upvc/cpvc As per building specification and direction of E/I. (1 No. )
Providing and laying of Interconnecting Puddle pipes and Flanges, as required for inter connection of the reactors, Drain lines and over flow.MOC- MSEP/Cpvc As per building specification and direction of E/I. (1 No. )
Non Compartmentalized and Non Drawout type Control Panel with PLC. Supply, installation, testing and commissioning of PLC Based Control Panel along with Solenoid Valves, cable, cable trays etc per reqiurement & Technical Specification.As per building specification and direction of E/I(1 NO. COMPLETE SET)
Supplying and fixing Modular kitchen of size 8’-10” X16’-10” in 1st floor, as per approved drawing with the following details including all materials & fittings, all complete job. As per building specification and direction of E/I
Materials :-
Carcass – 19 mm th. prelam land board ( Greenlam / Loft)
Door Shutter – 19 mm th. marine ply (Green/ Loft) with 2-0 mm th. acrylic sheet on both side/ MR TUFF laminate glossy finish
Hardware & handles – Sizes & design as per approved design, make – Sleek / Haffle/ Graff.
Glass door/ glass shelf – 8 mm th clear glass
Cabinet size (No. of cabinet = 23 nos approx.. & Area of shutter = 105 Sq,ft approx).
Base cabinet – 560 mm (D) x 720 mm (H) as per design
Top Cabinet – 350 mm (D) x 600 mm (H)
HOB – with all fillings – 80 cm, virgo / Equivalent
Chimney – 90 cm, Zinnia/ Equivalent
EQUIPMENTS :
Variable Refrigerant Flow System
SUPPLYING, INSTALLATION TESTING AND COMMISSNIG of Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by multiple scroll compressor controlled by individual inverter complete with indoor and outdoor units with individual wired and wireless/wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, internal control cabling and fittings etc. as per details given in specifications and having following items. The out door units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply. (Approved Brand - Hitachi/ Mitsubishi)
Outdoor Unit
40 HP ( 24+16) HP for TFA
Indoor Units
SUPPLYING, INSTALLATION TESTING AND COMMISSNIG of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities as per specifications and drawings . Indoor unit should Have VET technology to make more energy efficient. (Approved Brand - Hitachi/ Mitsubishi)
The units shall be suitable for 230V±6%, or 415V±10%, 50 Hz. supply & complete with electrical controls & panels. The cost of indoor unit shall include the cost of wire with plug top (assuming wire (3X2.5Sqmm) length of 8 to 10 Meters as per drawing). As per building specification and direction of E/I
Ductable type Indoor Unit
2.0 HP (530 CFM)
2.5 HP (800 CFM)
3.0 HP (1000 CFM)
4.0 HP (1200 CFM)
5.0 HP (1600 CFM)
8.0 HP (3000 CFM)
10.0 HP (3400 CFM)
20.0 HP (6400 CFM)
TFA Type Indoor Unit
8.0 HP (1000 CFM)
Total Heat Exchanger
1500 CMH @ 165 pascal Static with Duct Mouth of (400 mm x 320 mm )x 2
Supply, Installation, testing and commissioning of Imported Control Systems & Y-Joints :
Corded Remote controller. (For Ducted Unit) LCD Type Touch PAD
Y-Joints & Headers for IDUs
Installation of Master Remote Control panel including all necessary control wiring. It shall be connected to all indoor/outdoor units. Master Remote Control Panel shall be one touch screen type and suitable for 41 Nos of Indoor Unit. (Approved Brand - Hitachi/ Mitsubishi) As per building specification and direction of E/I
INSTALLATION & LOW SIDE WORKS
Installation, testing and commissioning of Variable Refrigerant Flow System
Outdoor Units
Installation, testing and commissioning of the above VRF outdoor units with R410A refrigerant, controls, electricals, necessary accessories of following capacities. (Approved Brand - Hitachi/ Mitsubishi) As per building specification and direction of E/I
40 HP ( 24+16) HP for TFA
Installation, testing and commissioning of the above VRF Indoor units:
Installation, testing and commissioning of the above VRF indoor units with refrigerant, controls, electricals, necessary accessories etc of following capacities. (Approved Brand - Hitachi/ Mitsubishi) As per building specification and direction of E/I
Ductable type Indoor Unit
2.0 HP (530 CFM)
2.5 HP (800 CFM)
3.0 HP (1000 CFM)
4.0 HP (1200 CFM)
5.0 HP (1600 CFM)
8.0 HP (3000 CFM)
10.0 HP (3400 CFM)
20.0 HP (6400 CFM)
TFA Type Indoor Unit
8.0 HP (1000 CFM)
Total Heat Exchanger
1500 CMH @ 165 pascal Static with Duct Mouth of (400 mm x 320 mm )x 2
REFRIGERANT PIPING:
Supply, Installation and testing of interconnect refrigerant copper piping with fitting duly insulated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification. All copper tubes shall be coated with transparent anti corrosive primer before insulation. All copper tubes shall be supported with suitable clamping & support etc. Covered Cable tray should be used for exposed refrigerant copper piping and tightened with self threaded screw. Make - RAJCO , MANDEV , NIPPON , MEHTA As per building specification and direction of E/I
54.0mm outer dia with 32 mm thick insulation.
50.8 mm outer dia with 32 mm thick insulation.
44.5mm outer dia with 19 mm thick insulation.
41.3mm outer dia with 19 mm thick insulation.
38.1 mm outer dia with 19 mm thick insulation.
34.9 mm outer dia with 19 mm thick insulation.
31.8 mm outer dia with 19 mm thick insulation.
28.6mm outer dia with 19 mm thick insulation.
25.4 mm outer dia with 19 mm thick insulation.
22.2mm outer dia with 13 mm thick insulation.
19.1mm outer dia with 13 mm thick insulation.
15.9mm outer dia with 13 mm thick insulation.
12.7mm outer dia with 13 mm thick insulation.
9.5mm outer dia with 13 mm thick insulation.
6.35mm outer dia with 13 mm thick insulation.
DRAIN PIPES OF INDOOR UNITS:
Supplying, laying, fixing, testing & commissioning of composite UPVC pipes Density not less than 10kg/m3 complete with insulation (9mm) and all necessary fittings such as elbows, tees, reducers U-trap, supports, clamps etc. as per specification & drawings. As per building specification and direction of E/I
32 mm dia
25 mm dia
Transmission & Control Wiring
Providing & fixing of control cum trans-mission wiring of copper (communication cable) between indoor and out door unit in 25 mm MS Conduit. AC Contractor shall include the cost of chiselling & finishing the wall / ceiling . As per building specification and direction of E/I
2C x 1.5 Sq mm (Unarmoured)
Supply and charging of Refrigerant R410A, (Approved Brand - Hitachi/ Mitsubishi) As per building specification and direction of E/I
Supply and fixing of VI pad for VRF Outdoor, (Approved Brand - Hitachi/ Mitsubishi)
DUCTING:
G.I. sheet ducting with 120 GSM GI sheet with TDF flanges, accessories like anchor fasteners, black painted MS angles/ rods for supporting, bracing & frames rubber gaskets, galvanised hardware, rivets, vanes, radius collars, rubber pad below each support etc. as per article SHEET METAL WORK. All ducts will be subjected to light test by insertion of light inside the duct in sections after erection but PRIOR TO INSULATION. Ducts with major leaks will be brought down for rectification. All minor leaks will be sealed with mastic sealant. As per building specification and direction of E/I
22 G - 1.0 mm minimum thickness
24 G - 0.8 mm minimum thickness
LINEAR GRILLES and DIFFUSSER:
Supply, installation, testing and balancing of extruded powder coated aluminium linear grills as per approved shop drawings & approved samples. As per building specification and direction of E/I
Supply Slot Diffusser type Grilles with Volume control damper. As per building specification and direction of E/I
Return Slot Diffusser type Grilles without VCD
Powder coated Aluminium Swirl diffusser with four way adjustable deflection with VCD for supply air as per article SHEET METAL WORK (Antlsmudge type diffuser) As per building specification and direction of E/I
Powder coated Aluminium Swirl diffusser with four way adjustable deflection without VCD for supply air as per article SHEET METAL WORK (Antlsmudge type diffuser) As per building specification and direction of E/I
Supply & Installation of Low Leakage GI sheet construction duct dampers 16G GI blade (100 mm wide), 16G GI frame (120 mm wide), chrome plated spindles self lubricating bushes, blade linkages fully enclosed, handle operation with status indicator. (Dampers of Gear and pinion type to be provided). As per building specification and direction of E/I
Supply and Installation of Fresh Air intake Louver with Bird Screen in extruded aluminium construction alongwith suitable volume control damper As per building specification and direction of E/I
ACOUSTIC LINING :
Acoustic insulation 240 kg / m3 density with Armasound/eqvt class 'O' microban open cell Nitrile Rubber-15 mm thick as per specification As per building specification and direction of E/I
15 mm thick acoustic lining
NITRILE RUBBER INSULATION:
THERMAL INSULATION OF DUCTS with Closed Cell Elastomeric Nitrile Insulation (class' O' fire rared) applied with water based Adhesive (Pidilite- AC Duct King or equal) -for internal ducts As per building specification and direction of E/I
15 mm thick nitrile rubber insulation.
Underdeck insulation material shall be with 19 mm Closed Cell Elastomeric Nitrile Insulation (class' O' fire rared) applied with water based Adhesive & 2 " Wide ECO-Tape on joints (Pidilite- AC Duct King or equal) As per building specification and direction of E/I
Supply and Fixing of plenum box
Supply, installation, testing, commissioning, and handing over of a central air cleaning system with high filtration efficiency on PM2.5 combined with a high kill rate on airborne infectious diseases using Ultraviolet Germicidal Irradiation. The system shall be designed for providing protection from airborne infection and maintaining Indoor Air Quality in AHU unit with the following features and technical specifications. It should be a Monobloc structured interconnectable units to form array of air cleaners specifically designed for integration in Return Air path, to centrally capture and kill germs and to improve indoor air quality. The unit shall include activated carbon filtration and UV-C light that together eliminate harmful gases and airborne microbes, including bacteria, fungi, and viruses. The multistage filter should be enclosed inside powder coated steel casing/ Galvanized steel cabinet and should be self contained. It should have a low pressure drop of 0.25" wg @ 2.5 m/s. The system shall meet EUROVENT ePM 1.0 80% requirement and ASHRAE guideline for UV-C application for airborne infection inactivation. The unit shall be Intertek ETL, UL 867, CSA C22 No. 187, and CE certified for safety and quality. The system shall be tested on E. coli (ATCC 15597) in accordance with the standard ASTM E2149 with a kill rate of 99% in less than 15 minutes. The system shall be designed in accordance with Chapter 62 Ultraviolet Air and Surface Treatment, 2019 ASHRAE Handbook. The system shall be ANSI/ASHRAE 52.2 2017 tested with at least a MERV 15 rating and an ISO 16890 ePM 1.0 90% rating by an accredited lab. The system must not emit Ozone, and maximum exposure concentration of ozone should not exceed 0.01 ppm. (Approved Brand - Hitachi/ Mitsubishi)
Central Control Air Quality monitor system for all Indoors to View and control As per building specification and direction of E/I
Supply, installation, testing & commissioning Electrical Starter Panel for all VRF outdoor units, Power Supply in all Indoors and Ventilation Equipment containing Wires, Switch Boards, MCB etc. As per building specification and direction of E/I
VENTILATION
IN LINE EXHAUST FAN (CIRCULAR) For Exhaust having a capacity of Following cfm complete with speed regulator, OFF timer (I.e. fan to switch off 30 min. after putting off the switch) complete with mounting arrangement. As per building specification and direction of E/I
100 CFM 12 MMWG 220/v Phase Toilet Circular- For Air Exhaust
150 CFM 12 MMWG 220/v Phase Toilet Circular- For Air Exhaust
450 CFM 15 MMWG 220/v Phase Toilet Circular- For Air Exhaust
AIR DISTRIBUTION
Supply ,fabrication and erection of GI sheet metal ducting with all necessary turning vanes, distribution grids, felt insertion / gasket for joints nut bolts , duct support, hangers etc. As per the workshop drawings As per building specification and direction of E/I
24 Gauge Duct
SUPPLY & FIXING OF CANVAS CONNECTION DOUBLE TYPE ZERO LEAKAGE FIRE RESISTED AND INSTALLATION CHARGES OF FAN As per building specification and direction of E/I
Both side Fan Canvas
GRILL & Diffuser - ALL POWDER COATED
Supply Slot Diffusser type Grilles with Volume control damper. As per building specification and direction of E/I
Inclined Green Wall Includes: A. MS Frame Structure with Paint &Installation. B. High Quality Polymer Fiber Frames. C. Plants D. Soil Mix E. Drip Irrigation with Timer F. Installation G. Double sided Green Wall H. Dimension: 32*4.5*2 ft = 288 sq.ft. per wall, Total No of Inclined wall 6 nos. With all complete job. as per approved dwg. design As per building specification and direction of E/I
Green Wall Near Green Lawn Includes: A. AS Frame Structure with Paint &Installation. B. High Quality Polymer Fiber Frames. C. Plants D. Soil Mix E. Drip Irrigation with Timer F. Installation G. Dimension: 16.8*25 ft = 420 sq.ftWith all complete job. as per approved dwg. design As per building specification and direction of E/I
Artificial Grass: A. 35mm Artificial Grass Carpet B. Fixing and Installation. C. Dimension: 29.5 * 24 ft = 708 sq.ft With all complete job. as per approved dwg. design As per building specification and direction of E/I
Drip Irrigation Near Trees on Terrace: A. 2 no of Timer B. 16 mm and 8mm Piped with all required fitting. C. Installation With all complete job. as per approved dwg. design As per building specification and direction of E/I
Drip Irrigation on Terrace Down Slab A. Total Length 308 running ft. B. 2 no of Timer C. 16 mm and 8mm Piped with all required fitting. D. Installation With all complete job. as per approved dwg. design As per building specification and direction of E/I
Drip Irrigation Near Green Lawn: A. Timer B. All Pipes work With Fitting C. Sprinkler D. Installation. With all complete job. as per approved dwg. design As per building specification and direction of E/I
Add 12 % GST
Add 1% Labour Cess
M/S RAM KRIPAL SINGH CONSTRUCTION PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid