Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹22.7 L+₹7.7 L (50.9%)Rejected-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L2 | Rejected-Finance Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Jan 2020, 6:00 pmClosed
GE KAPURTHALA
GARRISON ENGINEER KAPURTHALA
Repair/Replacement of External water supply and pumping sets at Mil Stn Kapurthala under GE Kapurthala
2019_MES_309709_1
GE KPT-65/2019-20
Open Tender
Civil Works
Item Rate
300 days
KAPURTHALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE KAPURTHALA
₹90,000
Yes
12 Mar 2020
27 Dec 2019
17 Jan 2020
27 Dec 2019
15 Jan 2020
2 Jan 2020
Amount
M & L for disconnecting electric connection and pipe connection and taking out submersible pump & motor of capacity 25 to 30 HP from bore well and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same guage and weight to existing including replacement of , Motor bush, thrust plate coupling complete with key and alignment of motor stater's slote reassembnling the motor with pump and lowering it into bore well making it functional and testing complete all as specified.
All as per item 1 above here in before but capacity 35 to 40 HP
All as per item 1 above here in before but capacity 35 to 40 HP of turbine motor pump including replacerment of ball bearings..
All as per item No 1 above but for sewage pump motor capacity 10 HP including replacement of ball bearings and alignment of motor starter stator..
All as per item No 1 here in before but for sewage pump motor of capacity 5 HP including replacement of ball bearings and alignment of motor starter and slote.. .
Repair / replacment of unserviceable part of submersible pump capacity 25 to 30 HP such as gun metal bush impeller assembly remetaling/turning to shaft, locking key and MS nuts & bolts of existing size and reassembling the pump with motor and making it functional all as specified.
All as per item No 6 here in before but for submersible pump for capacity 35 HP to 40 HP.
All as per item No 6 here in before but for sewage submersible pump for capacity 05 HP to 10 HP.
All as per item No 6 here in before but turbine pump of capacity 35 to 40 HP
Supply and fixing in replacement I diaphgram metering chemical dosing pump 3 phase 400/415 volt 4 pole 50 Hz 60 watt including PVC pipe of suitable size and PVC double walled container of capacity 100 Ltrs and including DOL Starter 60 watt complate all as specified and directed. Make : L&T/Siemen/Havells
Supply & Fixing Submersible pump set, Electric driven having dischage 1000 LPM at 84 mtr head including suitable capacity of electric motor not less than 30 HP suitable for operation of 415 volts 50 C/S AC supply
Supply & Fixing PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 10 sqmm in replacement of old U/S cable Make : Rallison / Plaza/Fenolax.
Supply & Fixing PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 16 sqmm in replacement of old U/S cable Make : Rallison / Plaza/Fenolax.
M & L for replacement of mechanical seal of non clog submersible sewage motor pumping set of capacity 10 HP Modle - 4NSC10C4A/ KRTO 100-260/74. Make :- MBH pumps as under:-
Mechanical seal (upper ) carbon / chromium steel
Mechanical seal (lower ) silicon
M & L for replacement of mechanical seal of non clog submersible sewage motor pumping set of capacity 5 HP. Modle - 4NSC10C4A/ KRTO 100-260/74. Make :- MBH pumps as under:-
Mechanical seal (upper ) carbon / chromium steel
Mechanical seal (lower ) silicon
Supply and fix in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 20 mm bore complete all as specified.
All as per item ser No 16 above here in before but 25 mm bore
All as per item ser No 16 above here in before but 40 mm bore
All as per item ser No 16 above here in before but 50 mm bore
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipe complete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed by Engineer-in-Charge.
Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
S&F GI coloumn pipe 100mm dia heavy duty 'C' class with flanged ends drill 3 meter including joining to exising main pipe line complete all as specified and directed (the cost of nuts bolts washers packing materials and pressure gauge shall be deemed to include in unit rate quoted by the contracror.
Taking down GI pipe 20 mm bore medium grade and fitting and supply and fixing GI tubing medium grade 20 mm bore in any length with all fitting laid in trench and connecting up with water supply main complete all as specified and directed (Excavation and earthwork shall be measured and paid for separetely under approprite item)
All as per item ser No 24 above here in before but 25 mm bore
All as per item ser No 24 above here in before but 40 mm bore
All as per item ser No 24 above here in before but 50 mm bore
Taking down old unserviceable GI/CI pipe 80 mm bore and supply, laying, jointing and testing new cast iron pipe 80 mm bore centrifugally cast class LA confirming to IS - 1536 spigot and socketed ends in any length laid in trenches complete all as specified and directed. (Note : excavation, earth work, CI fitting and new run lead joint shall be measured and paid for separetely under appropriate item of Sch 'A')
All as per item No 28 above here in before but 100 mm bore
All as per item No 28 above here in before but DI (K-7)100 mm bore
All as per item No 28 above here in before but 150 mm bore
All as per item No 28 above here in before but DI (K-7)150 mm bore
Supply and fixing in replacement cast iron fitting such as bends, tapers, (any type, radius and angle) tapers any type, (straight, bend, increasing,decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs tee pieces, single branch for spigot and socket and flanged pipe up to 150 mm bore complete all as specified and directed.
Supply and fixing in replacement cast pipe 150 mm bore centrifugally cast class 'A' flanged both end in any length complete all as specified and directed.
Supply and fixing in replacement cast pipe 100 mm bore centrifugally cast class 'A' flanged both end in any length complete all as specified and directed.
M&L for lead joint suitable for CI pipe 80 mm bore complete all as specified and directed.
M&L for lead joint suitable for CI pipe 100 mm bore complete all as specified and directed.
M&L for lead joint suitable for CI pipe 150 mm bore complete all as specified and directed.
Supply and fixing in replacment cast iron sluice valve 80 mm bore with flanged ends, ISI mark with Gun metal spindle, CI gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S sluice valve complete all as specified
All as per srl item No 41 here in before but 100 mm dia.
All as per ser item No 41 above here in before but 150 mm bore
M &L for earth work in trenches / pit and bailing out water to rectfying leaking joint of CI pipe spigot and socket type 80 mm bore including pouring extra lead chieseling and levelling the excavated material after rectifying the leakage complete all as specified.
All as per item ser No 42 above here in before but 100 mm bore
All as per item ser No 42 above here in before but 150 mm bore
S& F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure type ML-2 FASD 3 phase 440 volt 50 Hz of capacity 35 HP. Make : L&T/SIEMEN/Havells
M & L for replacment existing cast iron double air release valve of size 80 mm bore replacment of worn out bolts, nuts gaskets if any complete all as specified and directed.
Supply, install, testing and commissioning of Star Delta starter panel capacity 35 HP panel size 80cm x 60cm x 40cm enclosures cubical weather and vermin proof totally enclosed made out of 2mm thick CRCA sheet machine pressed of suitble size to operate on 3 Phase 4 wire system 415 Volts, 50 HZ double door with front openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom Gland plate with sufficient numbers of circular cable entery holes, including PCC work, prewired complete duly powder coated with comprising of the following:-
Repair to existing valve pits of internal dimensions 90cm x 90 cm x 90 cm making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in CM 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.(a) M&L for brick work using sub class 'B' (old size bricks) in CM 1:4 (b) M&L for rendering 15 mm thick in CM 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface.
M & L for cleaning & flushing of RCC overhead reservoir of capacity 100000 gallons at 60 feet staging removing of silt and sludge to a distance not exceeding 50 Mtr from GL etc deposited inside the tank cleaning entire internal surface of tank with bleaching powder and flushing with water complete all as specified and marking Dt of cleaning with enamelled paint as directed.
All as per item No 49 here in before but Capacity 75000 gallon at 60 feet staging
All as per item No49 here in before but Capacity 50000 gallon at 60 feet staging
Supply and fixing non clog submersible pump set suitable to handle raw sewage water having discharge 930 Lpm at ahead fo 15 mtr (as per manufactures design ) along with 10 HP, 3 phase 415 V,50 Hz 1500 RPM suction and delivery complete all as specified and directed. Make : Kirlosker/Crompton/KSB
Sweeping / cleaning and taking out sludge in consolidated position from underground sumps including cleaning of internal walls, surfaces and floor thoroughly to make it free from dirt by scrubbing and washing accumulated materials with water, including cleaning of suction lines inside wet sump and removing from site to outside Army Area complete all as directed by Engr -in - charge. Note :- Work is in full condition, there the contractor is required to take necessary safety precautions and arrange safety mask, hand gloves etc at his own expense. The under ground sumps have depths varying from 6 to 15 Mtr and are located in different pockets of New Cantt and old cantt areas in Army area Kapurthala. Quoted rate is deemed to be inclusive of the above aspect.
Attending complaints by deploying sufficient labour (Skilled and helpers) for repair to leakage/blockage of wall/underground water carrying GI/CI/DI pipes of sizes ,20mm to 200 mm bore of any description at any location including necessary excavation & earth work, cutting existing pipe lines, dewatering etc complete all as specified. NOTE:- (i) Complaint shall be notified to contractor on telephone, therefore it is mandatory for the contractor to mention his ‘Mobile Number’ while quoting the tender. (ii) Complaint shall be notified to contractor at any time between 0600 hrs to 2000 hrs and the same shall be immediately attended and defects rectified within six hrs from notification of complaint to the contractor. (iii) Confirmation of attendance & rectification of complaint shall be given in writing by the contractor and same shall be recorded in the ‘Register’ maintained for the purpose. The ‘Register’ shall be produced to this office along with RAR/Final Bill. (iv) In case the contractor fails to attend complaints within stipulated time (i.e. 6 hrs), a penalty shall be imposed @ Rs 300/- per complaint. (iv) Rates quoted by the contractor shall be deemed included the cost of necessary T& P required. (v) Pipes and cost of jointing shall be measured and paid separately under respective items.
Supply and fixing On load change over switch front handle operated 400 Amp open execution Four pole 415 volt. equivelent make Standard/L&T/Indo Asian
.M&L for replacement on load change over rotery type 4 pole 415 volt 200 AmpMake :Standard/L&T/Indoasian
All as per ser item No 56 here in - before but 100 Amp
S&F in replacement MCCB 350 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 200 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 160 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
Supply only Calcium based granuler disinfect suitable for treatment drinking water in 45 kg plastic drum complete all as specified and directed Make: Rayal Seema/Aquafit
J K AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .