| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Being LOwest | |
| 2 | L2₹13.4 L+₹90,966 (7.26%)Rejected-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance BEING other than Lowest | |
| 3 | L3₹13.4 L+₹92,077 (7.35%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance BEING other than Lowest | |
| 4 | L4₹13.6 L+₹1.0 L (8.20%)Rejected-Finance | L4 | Rejected-Finance BEING other than Lowest | |
| 5 | L5₹13.7 L+₹1.1 L (9.05%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L5 | Rejected-Finance BEING other than Lowest |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
24 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
PROVISION OF POWER SUPPLY FOR PRE FABRICATED CABINS FOR POST GRADUATE TRAINEES AT INHS ASVINI UNDER AGE (I) ASVINI COLABA MUMBAI
2021_MES_445865_1
8087/CWE(NW)/MUMBAI
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE (I) Asvini
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE (I) Asvini
₹29,000
Yes
9 Aug 2021
26 May 2021
26 Jun 2021
26 May 2021
24 Jun 2021
12 Jun 2021
26 May 2021 - 11 Jun 2021
60 days
Amount
Material and labour for Earthing complete with galvanized iron earth plate electrode 600 x600x6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.6 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts check nuts galvanized iron or steel all as shown in Electrical plate No. 3 of MES sch pt I testing on completion with & incl. 15 mm bore light grade GI protection pipe 7.5 mtr long for earth lead, PCC (1:3:6) pit with pre cast RCC (1:2:4) cover watering arrangement with funnel, wire mesh 20 mm bore light grade GI pipe, common salt & char coal fixing necessary excavation earth work complete all as specified and as directed by Engr- In-Charge.
Supply and Fixing TPN DB-VTPN, DPX3 MCCB DBs 4 Way, (DPX3 160+12) suitable for flush mounting and surface mounting, conforming to IP 54 - IK 09 with prefitted masking sheet with 250 Amp copper bus bar for each phase, complete with 2 Neutral bar and 2 Earthing bar and cable ties for cable management, provision for DPX3 upto 160 MCCB as incomer and SP/TP MCBs as outgoing as per IEC 61439-3, connection complete and making good the disturbed surfaces complete all as specified and as directed by Engr- In-Charge.Make:- Legrand cat part No. 507750 or Equivalent Havells/L&T/ C&S Electric Ltd/ABB.
Supply and Fixing MCB SPN DB 8 Way, (8) suitable for flush mounting and surface mounting, conforming to IP 43 - IK 09 with acrylic door with 100 Amp copper bus bar for each phase, complete with din rail, Neutral and Earthing bar connection complete and making good the disturbed surfaces complete all as specified and as directed by Engr- In-Charge.Make:- Legrand cat part No. 507621 or Equivalent Havells/L&T /C&S Electric Ltd/ABB.
Supply and Fixing DX3 MCB SPN, 240 Volt, 16 to 63 Amp, 10 KA, IP 20 Protected terminals, complete all as specified and as directed by Engr- In-Charge.Make:- Legrand cat part No. 408620 or Equivalent Havells/L&T /C&S Electric Ltd/ABB.
Supply and Fixing DX3 MCB SP, 240 Volt, 6 to 40 Amp, 10 KA, IP 20 Protected terminals, Complete all as specified and as directed. Make:- Legrand cat part No. 408596 or Equivalent Havells/L&T /C&S Electric Ltd/ABB.
Material and labour for MCCB 4 Pole, 415 V, Thermal magnetic adjustable type, 160 Amps with breaking capacity 25 KA, complete all as specified and directed. Make:- Legrand cat part No. 420057 or Equivalent Havells/L&T /C&S Electric Ltd/ABB.
Material and labour for Sub main wiring with two single core (Red and Block Colour) PVC insulated unsheathed FRLS copper conductor 1100 volt grade multistandard of size 6.0 sqmm and incl drawn through PVC casing capping 25x12mm/32x12mm including accesssories (ISI marks), one run of single core (Green colour) PVC insulated unsheathed FRLS copper conductor 1100 volt grade multistandard of size 6.0 sqmm for earth continuity wire and connected of common earth dolly. Note:- One run of PVC casing capping 25x12mm/32x12mm, two run of 6.0 sq mm copper conductor & One run of 6.0 sq mm copper conductoris measured as one unit.
Supply , installation ,fabrication, testing and commissioning of LT Panel board, Factory made cubical type, Outdoor type, floor mounted, factory made out of 40mm x 40mm x 4mm angle iron frame and 3.15 mm inner CRCA steel sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including suitable rated aluminium bus bar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of 630 amps rated aluminium bus bar for neutral complete with the following accessories incl Cable Gland & PCC Foundation and Coping complete all as specified and as directed by Engr- In-Charge.
Supply & laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 300 sqmm x 3.5 core laid in trenches, passing through pipes, fixed on walls including connecting properly by means of thimbles complete all as specified and as directed. Make : Finolex/Havells/Polycab.
Supply & laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 70 sqmm x 3.5 core laid in trenches, passing through pipes, fixed on walls including connecting properly by means of thimbles complete all as specified and as directed by Engr- In-Charge. Make : Finolex/Havells/Polycab.
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out complete all as specified and as directed by Engr- In-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and as directed by Engr- In-Charge.
Removing excavated material from the site of work to outside MD land complete all as specified and as directed by Engr- In-Charge.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and complete all as specified and as directed by Engr- In-Charge. Note :- Only compacted thickness of sand will be measured and paid .
Supply, laying un-reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150 mmx 40 mm complete all as specified and as directed by Engr- In-Charge.
Cutting existing road surfaces or hard standing 0.45 mtr depth (22 thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces complete all as specified and as directed by Engr- In-Charge.
Material and labour for PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) for road/Hard standing cutting complete all as specified and as directed by Engr- In-Charge.
Material and labour for GI pipe ,light grade 50mm dia for road crossing of cable for cable protection or above ground surface complete all as specified and as directed by Engr- In-Charge.
Material and labour for GI pipe ,light grade 80mm dia for road crossing of cable for cable protection or above ground surface complete all as specified and as directed by Engr- In-Charge.
Supply and Fixing in Single phase LCD Energy meter 240 volts of accuracy class 1.0 temper proof energy meter of rating 10 to 60 Amps, including fixing arrangements i.e wooden board, fastner net and bolts, input/output connections, meter seal with SWG wire etc, complete all as specified and as directed by Engr- In-Charge. Make: HPL, Model No. SPPB1520110E1 or as approved by GE.
GANGAJAL
Shree Ayyappa Engineering
M/s R J TRADING CO
M/S. Niksun Electro-Infra Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .