Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC 114 4 3 HAZRA ROAD KOLKATA 700026 | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹7.4 L+₹26,470 (3.72%)Rejected-Finance 90 E BECHARAM CHATTERJEE ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹7.4 L+₹29,390 (4.13%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L3 | Rejected-Finance 3rd lowest bidder |
Tender Value
Refer Docs
EMD Value
₹14,960
Closing Date
30 Jan 2019, 12:00 pmClosed
EE_I, South Kol. Health El. Division, P.W.Dte
75 D H Road Kidderpore Kol_20
E.I work for installation of Computer board for online establishment at different areas of Academic Building and SITC of On line UPS system at Server room of Ronald Ross Building in the Campus of IPGMER_SSKM Hospital Kolkata.
2019_WBPWD_204885_1
WBPWD/SKHED/Q54/18-19
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
2 documents required · 2 mandatory
₹14,960
O/o, EE, South Kol. Health El. Division, P.W.Dte
8 Feb 2021
3 Jan 2019
1 Feb 2019
3 Jan 2019
30 Jan 2019
12 Jan 2019
11 Jan 2019
Amount
S&F Double Door 2+10 Way SPN MCB BDB comprising with 1 No. 250V. 63 A. DPMCB Isolator and 10 nos. 250 V. 6 - 16 A. SP MCB as outgoing, complete with DIN Channel, Neutral Bar, Earth Bar and other accessories & connection with suitable size of Cu. wire with proper socketing incl. necsy.earthing attachment. (Make-Legrand / Schneider/ABB)
S&F 16 SWG M.S. box of following sizes with 3 mm. thick bkt top cover and earthing attachment incl. making connection as per GS:-
8" x 10" x 2½" 1 No. 250 V. 6-pin 16A plug socket with 1 No. 16A piano key switch & 3 Nos. 5-pin 6A plug socket with 3 Nos. 5A piano key switch and 1 no. Indicating Lamp (Make-Anchor).
8" x 6" x 2½" M.S. Board with 1 No. 250 V. 6-pin 16A plug socket with 1 No. 16A piano key switch & 1 No. 5-pin 6A plug socket with 1 Nos. 6A piano key switch (Make-Anchor).
S/D following sizes PVC insulated Cu wire (Finolex/Havells/RR Kable-FRLS) in PVC rigid conduit pipe (Precision -M) as follows incl. making connections :-
2 x 2.5 & 1x 1.5 mm² for Computer Board.
2 x 6 & 1 x 4 mm² in 20mm from PBDB to SPN DB
2 x 10 mm² in 20mm from Copper plate earthing to Server Room.
Finishing the end of following sizes copper wire end / PVC cable/Al. with dowells solderless socket by crimping method as pre GS as follows :-
2 x 2.5 & 1 x 1.5 mm² cu. wire
2 x 6 & 1 x 4 mm² cu. Wire
S&F of Copper Earth Bus Bar (38 x 6 ) mm incl. 8 nos holes with nuts, bolts & washer etc to be fixed on wall as per direction of EIC.
S&F 440V., MCB type 40A 4 pole changeover switch in 6 way SS enclosure complete with all accessories to be fixed on wall all with earthing attachment. (Make :-L&T/Legrand/Schneider) (For 10 KVA UPS).
S&F 240V., MCB type 63A 2 pole changeover switch in 4 way SS enclosure complete with all accessories to be fixed on wall all with earthing attachment. (Make :-L&T/Schneider/HPL) (For 10 KVA UPS).
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter(inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode. [For Server Room at 3rd floor of Ronald Ross Building).
SITC of 10 KVA Modular Type 3 phase IN & 3 Phase out, Isolation Transformer with 30 Min backup. (Make - Numric/APC/Emerson/Switching AVO)
Topology, IGBT BASED DSP CONTROLED
Input Voltage: 415 VAC, 335 to 475 VAC
Input Frequency: 50 Hz, 47 to 53 Hz
Input PF: > 0.9
Output Voltage: 415 VAC +/- 1%
Output Frequency: 50 Hz +/- 0.1% in Free running & +/- 4% in Sync
Isolation Transformer: Provided Inbuilt / external
Power Factor: 0.9 Lag
Crest Factor: 3:1
Waveform: Sinusoidal
THD: < 3% on linear load & < 5% on non-linear load
Overload: 110% for 10 minutes, 125% for 4 minutes, 150% for 60 msec
Transient Response : For 0 - 50% & 50% - 100% load change voltage remains within +/- 5%
Ripple: < 2%
Inverter Efficiency: > 93%
Minimum VAH - 10080 VAH Battery Make: Exide, Amar Raja Quanta (SMF)
Battary Cabinet: With powder coated MS rack with Netguard for ventilation & battery interlink cables (Minimum FR grade)
Protections: Input & Output Over / Under Voltage, Single Phasing DC - High / Under Voltage, Battery Charging Over Current, Output Overload / Short Circuit / Over Temp., UPS auto ON on Mains recovery
Audio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter Trip
Metering: LCD display for Input & Output - Voltage, Current & Frequency, Battery - Voltage & Current
Indications: Mains - On / Fail / High / Low / Single Phasing DC - On / High, Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over Current
Switchgear: MCB / MCCB for Input, Battery, Output & Manual Bypass Switch
Communication: RS 232
Monitoring Software: UPS Monitoring Software on Windows XP Platform
Static Switch: Provided with changeover < 5 msec in sync & < 20msec in non-sync
Certification : ISO 9001&14001,ISO 18001
SIMPSON AND FERRIS PVT LTD
GHANASHYAM ELECTRIC STORES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .