| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹32.8 L+₹62,612 (1.95%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹35.4 L+₹3.3 L (10.2%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹36.6 L+₹4.5 L (13.8%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L4 | Rejected-Finance L4 | |
| 5 | L5₹36.9 L+₹4.7 L (14.6%)Rejected-Finance 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | L5 | Rejected-Finance L1 |
Tender Value
₹37.1 L
EMD Value
₹74,160
Closing Date
12 Nov 2024, 6:00 pmClosed
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
PROVN OF 400 KVA TRANSFORMER WITH CONNECTED INFRA FOR CARDIAC CATH LAB PROJECT OF MH JAIPUR UNDER ZONE II AREA AT JAIPUR MILITARY STATION
2024_MES_679230_1
CWE/JPR/82418/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAIPUR
AS PER NIT
7 documents required · 7 mandatory
₹500
GE JAIPUR
₹74,160
Yes
16 Jan 2025
11 Oct 2024
14 Nov 2024
11 Oct 2024
12 Nov 2024
28 Oct 2024
11 Oct 2024 - 26 Oct 2024
Amount
Supply, installation, testing and commissioning of copper wound transformer outdoor type complete with OEM standard fittings & accessories of connected 3 Phase, 4 wire,50 Hz with off load tappings on HT side to vary secondary voltage within limit, continunuously rating factory assembled fully wired on base frame to give an output of, confirming to standerd as IS:1180 (Part-I) : 2014, Level -02 of following technical perticulars:- (a) Rating of Transformer : 400KVA (b) Type of Cooling : ONAN (Oil Natural Air Natural) (c) Rated Voltage at on load (HV/LV(in KV) : 11/0.433 (d) Connection(HV/LV) & Victor Grup : Delta/Star,Dyn11 (e) Insulation Level HV/LV (in kv) : Impulse 75K, Power frequency 1min-28KV (HT Side), 3KV (LT Side) (f) Type of Tape changer: Off circuit/On circuit : Off Circuit Tap changer (g) Tap range Number of step, Step size & Location : +5% to -10% @ 2.5% on HV Side (h) Temperature rise of top oil/winding (ºC) : 40/45 Degree, EEL-2 (j) Losses @ 50% load (in Kw) : 1.150 Max (k) Losses @ 100% load (in Kw) : 3.330 Max
(l) % impedance volts at 75 ºC, rated current & frequency : 4.5% +/- 10% as per IEC 60076 (m) Presentage efficiency @ UPF : As per IS 1180 Amend 04 Level-02 (i) 100% load (ii) 75% load (iii ) 50% load (n) Presentage regulaton at full load at UPF 0.8 lagging PF : As per IS 1180 (Amend 04) Level 2 (o) Altitude : Up to 1000 Mtr above sea level. (p) Termination HV/LV : HV (Cable Box), LV (Cable Box)/180deg. (r) Transformer oil:- (i) New miniral insulating oil (Properties as per IS 335) (ii) Oil shall be filled and tested for breakdown voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum. (iii ) Dial thermometer, Accuuency class 1.5 similar to EN:13190 range (-30 to 80ºC). (s) Note: Before dispatch the transformer shall be tested for routine test in the presence of Rep of Accepting Officer.
Supply, laying or fixing on wall through proper clamping or passing through pipe, testing and commissioning cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 150 Sqmm.
Supplying, laying or fixing on wall through proper clamping or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable all as following:- (Make - Havells / Polycab / Finolex / Universal as approved) (a) 500 sqmm 3.5 core
(b) 400 sqmm 3.5 core
(c ) 240 sqmm 3.5 core
Supply and fix cable jointing kit for 11 KV (HT) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm.
Supply and fix cable jointing kit for 1.1 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3.5core XLPE armoured aluminium conductor cable of size 500 Sqmm. (a) 400 to 500 sqmm 3.5 core
Supply and fix cable jointing kit for 1.1 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3.5core XLPE armoured aluminium conductor cable of size 500 Sqmm. (b) 240 sqmm 3.5 core
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil complete all as specified and directed
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed
M&L for sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying including gently punning around cable complete all as specified in SSR Part-I and directed.
M&L for cable cover HVP type of size 300mmx180mmx40mm laid in trenches flat with width equal to length of cover for cable protection laid across the cable complete all as specified and directed.
S&F galvanised mild steel tubes "light grade " of 80 mm bore (ISI marked) with all fitting( ISI marked) and fixed to walls and ceilings or laid in floors/ trenches and under road, complete all as specified and directed.
All as per Item No:15 as above but 100 mm size.
Supply and fixing in replacement danger notice plate of size 25x20cm made out of MS sheet 1.6 mm thick, vitreous enameled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts on LT poles complete all as directed by Engineer-in-Charge.
M&L for foundation of transformer /plinth of using bricks well burnt sub class 'B' with PCC type B2 1:3:6 ,suitable size for transformer up to 500 mm extended from base plate of unit including base plate, anchor Bolt/hole all as required foundation depth 750 mm and hight from ground/plane to min 1800 mm and neccesaary arrangments must be included to withstand against vibration and self weight of transformer and plinth,piller and wall all as specified and directed.
M& L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness ,M-40 Grade ,with grey cement complete all as specified and directed
M & L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, gusset plates, riveting, as necessary attached with existing fancing of installation etc. not exceeding 10 kg each brackets, conforming to Fe-290 Gde-E-165 incl painting with two coats of synthetic enamel paint over a one coat of red oxide primer for mounting of water tank and similar work complete all as specified and directed.
M&L for chain link fancing MS galvanised steel fencing, any size or type 4 mm dia wire class of fencing including straining and fixing to wood, concrete or steel posts or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, including line wires, any mesh, any type of standards, rails, straining bolts, etc. including provision of binding wire to coverd the installation complete etc. as specified as directed.
M & L for fabrication, installation, testing & commissioning of factory made CPRI approved outdoor cubical type made out of 3.0 mm thick CRCA sheet suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system with short circuit with stand capacity 35 MVA for 1 second, IP 54 protection, fabricated in compartmentalized design totally enclosed, dust, weather & vermin proof, having TPN copper bus bars of rating 1.5 times that of controlling MCCB supported on 'F' class SMC insulators, bottom base channel of MS section not less than 75 mm x 40 mm x 5 mm thick, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size copper bus bars and control wiring with minimum 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates including digital multi functional meter to measure voltage, current, PF & frequency and mounted on by making suitable PCC foundation, necessary inter connection including following controls :-
M & L for fabrication of CPRI approved LT panel board outdoor type with single door made out of 3.15 mm thick MS sheet, dust, vermin and water proof duly supported on 25 x 25 x 4 mm angle iron frame, having locking arrangement at front and opening arrangement from front & rear both duly fitted with 400 Amp rated aluminium busbar 4 strip with 2 Nos compression cable glands upto 240 sqmm 3.5 core for entry & exit of cables, powder coated with two coats and having minimun clearance of 450 mm above ground level complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.25mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI strip of size 32x6mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 40mm bore GI pipe medium grade for protection of GI strip upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr, all as specified ans shown in Electrical plate No. 3 of SSR Part-1, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion complete. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
PRAJAPATI E and S ENGG CO (BID ID -3163565)
SHREE BHAGWATI ENTERPRISES (BID ID -3163545)
Rasam Engg Co. (BID ID -3163229)
HUMERS INFRATECH (BID ID -3157117)
MONA GENERATOR SEVICES PVT. LTD. (BID ID -3158304)
Shiv Enterprises (BID ID -3163197)
Electromech Engineers (BID ID -3157598)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .